1.
J Neural Eng ; 15(6): 066003, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30124202

RESUMO

OBJECTIVE: Stereotactic frame systems are the gold-standard for stereotactic surgeries, such as implantation of deep brain stimulation (DBS) devices for treatment of medically resistant neurologic and psychiatric disorders. However, frame-based systems require that the patient is awake with a stereotactic frame affixed to their head for the duration of the surgical planning and implantation of the DBS electrodes. While frameless systems are increasingly available, a reusable re-attachable frame system provides unique benefits. As such, we created a novel reusable MRI-compatible stereotactic frame system that maintains clinical accuracy through the detachment and reattachment of its stereotactic devices used for MRI-guided neuronavigation. APPROACH: We designed a reusable arc-centered frame system that includes MRI-compatible anchoring skull screws for detachment and re-attachment of its stereotactic devices. We validated the stability and accuracy of our system through phantom, in vivo mock-human porcine DBS-model and human cadaver testing. MAIN RESULTS: Phantom testing achieved a root mean square error (RMSE) of 0.94 ± 0.23 mm between the ground truth and the frame-targeted coordinates; and achieved an RMSE of 1.11 ± 0.40 mm and 1.33 ± 0.38 mm between the ground truth and the CT- and MRI-targeted coordinates, respectively. In vivo and cadaver testing achieved a combined 3D Euclidean localization error of 1.85 ± 0.36 mm (p < 0.03) between the pre-operative MRI-guided placement and the post-operative CT-guided confirmation of the DBS electrode. SIGNIFICANCE: Our system demonstrated consistent clinical accuracy that is comparable to conventional frame and frameless stereotactic systems. Our frame system is the first to demonstrate accurate relocation of stereotactic frame devices during in vivo MRI-guided DBS surgical procedures. As such, this reusable and re-attachable MRI-compatible system is expected to enable more complex, chronic neuromodulation experiments, and lead to a clinically available re-attachable frame that is expected to decrease patient discomfort and costs of DBS surgery.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Neuronavegação/instrumentação , Técnicas Estereotáxicas/instrumentação , Animais , Parafusos Ósseos , Cadáver , Estimulação Encefálica Profunda , Reutilização de Equipamento , Humanos , Imageamento por Ressonância Magnética/métodos , Neuronavegação/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Cirurgia Assistida por Computador/instrumentação , Suínos , Tomografia Computadorizada por Raios X
2.
Front Hum Neurosci ; 10: 102, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27014033

RESUMO

Deep brain stimulation (DBS), a surgical technique to treat certain neurologic and psychiatric conditions, relies on pre-determined stimulation parameters in an open-loop configuration. The major advancement in DBS devices is a closed-loop system that uses neurophysiologic feedback to dynamically adjust stimulation frequency and amplitude. Stimulation-driven neurochemical release can be measured by fast-scan cyclic voltammetry (FSCV), but existing FSCV electrodes rely on carbon fiber, which degrades quickly during use and is therefore unsuitable for chronic neurochemical recording. To address this issue, we developed durable, synthetic boron-doped diamond-based electrodes capable of measuring neurochemical release in humans. Compared to carbon fiber electrodes, they were more than two orders-of-magnitude more physically-robust and demonstrated longevity in vitro without deterioration. Applied for the first time in humans, diamond electrode recordings from thalamic targets in patients (n = 4) undergoing DBS for tremor produced signals consistent with adenosine release at a sensitivity comparable to carbon fiber electrodes. (Clinical trials # NCT01705301).

3.
Neuroimage ; 105: 181-8, 2015 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-25451479

RESUMO

Thalamic deep brain stimulation (DBS) is an FDA-approved neurosurgical treatment for medication-refractory essential tremor. Its therapeutic benefit is highly dependent upon stimulation frequency and voltage parameters. We investigated these stimulation parameter-dependent effects on neural network activation by performing functional magnetic resonance imaging (fMRI) during DBS of the ventral lateral (VL) thalamus and comparing the blood oxygenation level-dependent (BOLD) signals induced by multiple stimulation parameter combinations in a within-subject study of swine. Low (10 Hz) and high (130 Hz) frequency stimulation was applied at 3, 5, and 7 V in the VL thalamus of normal swine (n = 5). We found that stimulation frequency and voltage combinations differentially modulated the brain network activity in the sensorimotor cortex, the basal ganglia, and the cerebellum in a parameter-dependent manner. Notably, in the motor cortex, high frequency stimulation generated a negative BOLD response, while low frequency stimulation increased the positive BOLD response. These frequency-dependent differential effects suggest that the VL thalamus is an exemplary target for investigating functional network connectivity associated with therapeutic DBS.


Assuntos
Estimulação Encefálica Profunda , Córtex Motor/fisiologia , Vias Neurais/fisiologia , Núcleos Ventrais do Tálamo/fisiologia , Animais , Gânglios da Base/fisiologia , Imageamento por Ressonância Magnética , Masculino , Córtex Sensório-Motor/fisiologia , Suínos
4.
J Neurosurg ; 119(6): 1556-65, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24116724

RESUMO

OBJECT: Conventional deep brain stimulation (DBS) devices continue to rely on an open-loop system in which stimulation is independent of functional neural feedback. The authors previously proposed that as the foundation of a DBS "smart" device, a closed-loop system based on neurochemical feedback, may have the potential to improve therapeutic outcomes. Alterations in neurochemical release are thought to be linked to the clinical benefit of DBS, and fast-scan cyclic voltammetry (FSCV) has been shown to be effective for recording these evoked neurochemical changes. However, the combination of FSCV with conventional DBS devices interferes with the recording and identification of the evoked analytes. To integrate neurochemical recording with neurostimulation, the authors developed the Mayo Investigational Neuromodulation Control System (MINCS), a novel, wirelessly controlled stimulation device designed to interface with FSCV performed by their previously described Wireless Instantaneous Neurochemical Concentration Sensing System (WINCS). METHODS: To test the functionality of these integrated devices, various frequencies of electrical stimulation were applied by MINCS to the medial forebrain bundle of the anesthetized rat, and striatal dopamine release was recorded by WINCS. The parameters for FSCV in the present study consisted of a pyramidal voltage waveform applied to the carbon-fiber microelectrode every 100 msec, ramping between -0.4 V and +1.5 V with respect to an Ag/AgCl reference electrode at a scan rate of either 400 V/sec or 1000 V/sec. The carbon-fiber microelectrode was held at the baseline potential of -0.4 V between scans. RESULTS: By using MINCS in conjunction with WINCS coordinated through an optic fiber, the authors interleaved intervals of electrical stimulation with FSCV scans and thus obtained artifact-free wireless FSCV recordings. Electrical stimulation of the medial forebrain bundle in the anesthetized rat by MINCS elicited striatal dopamine release that was time-locked to stimulation and increased progressively with stimulation frequency. CONCLUSIONS: Here, the authors report a series of proof-of-principle tests in the rat brain demonstrating MINCS to be a reliable and flexible stimulation device that, when used in conjunction with WINCS, performs wirelessly controlled stimulation concurrent with artifact-free neurochemical recording. These findings suggest that the integration of neurochemical recording with neurostimulation may be a useful first step toward the development of a closed-loop DBS system for human application.


Assuntos
Estimulação Encefálica Profunda/instrumentação , Equipamentos e Provisões/normas , Retroalimentação Fisiológica/fisiologia , Neurotransmissores/fisiologia , Animais , Técnicas Biossensoriais/normas , Corpo Estriado/metabolismo , Estimulação Encefálica Profunda/métodos , Estimulação Encefálica Profunda/normas , Dopamina/metabolismo , Técnicas Eletroquímicas/normas , Desenho de Equipamento/normas , Masculino , Feixe Prosencefálico Mediano/fisiologia , Microeletrodos/estatística & dados numéricos , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...