Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Expert Opin Drug Deliv ; 17(10): 1485-1498, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32700596

RESUMO

OBJECTIVES: User experience was compared between a new pre-fillable 2.25 mL glass syringe equipped with an ultra-thin-wall (UTW) 8 mm staked needle and a marketed BD Neopak™ syringe equipped with a special-thin-wall (STW) 12.7 mm staked needle. METHODS: Participants simulated subcutaneous injections with both syringes alone (formative Human Factors study) and in combination with a needlestick-prevention device (validation Human Factors study). RESULTS: Usability results of both studies showed higher success rates for delivering the full dose of 2 mL viscous solution (30 cP) with the 8mmUTW syringe than with the 12.7mmSTW one (63% vs. 42% in the formative study). The use of the 8mmUTW syringe demonstrated also better ease of use and acceptance results and 72% of formative study participants preferred this new syringe over the current one when delivering the viscous solution. Using a shorter needle also showed a benefit in decreasing the injection-related anxiety. Besides, in the case of a non-recommended injection technique, the calculated risk of accidental intramuscular injection is reduced by 2 to 13 times with the 8mmUTW syringe. CONCLUSION: Altogether, the results obtained demonstrated an improvement of the user experience with this new syringe compared to the current one in the manual delivery of 2 mL viscous solutions.


Assuntos
Agulhas , Seringas , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Injeções Intramusculares , Injeções Subcutâneas , Masculino , Pessoa de Meia-Idade , Viscosidade
2.
PLoS One ; 10(7): e0134048, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26208168

RESUMO

Infectious murine models greatly benefit from optical imaging using bioluminescent bacteria to non-invasively and repeatedly follow in vivo bacterial infection. In this context, one of the most critical parameters is the bioluminescence sensitivity to reliably detect the smallest number of bacteria. Another critical point is the anesthetic approaches that have been demonstrated to impact the bioluminescence flux emission in studies with luciferase-transfected tumor cells. However, this impact has never been assessed on bacteria bioluminescent models. To this end, we investigated the effects of four anesthesia protocols on the bioluminescence flux in a central venous catheter murine model (SKH1-hr(hr) mice) infected by a bioluminescent S. aureus Xen36 strain. Bioluminescence imaging was performed on mice anesthetized by either ketamine/xylazine (with or without oxygen supplementation), or isoflurane carried with air or oxygen. Total flux emission was determined in vivo daily for 3 days and ex vivo at the end of the study together with a CFU counting of the biofilm in the catheter. Bioluminescence flux differences appear between the different anesthetic protocols. Using a ketamine/xylazine anesthesia (with air), bacteria detection was impossible since the bioluminescence signal remains in the background signal. Mice anesthetized with isoflurane and oxygen led to a signal significantly higher to the background all along the kinetics. The use of isoflurane in air presents a bioluminescence signal similar to the use of ketamine/xylazine with oxygen. These data highlight the importance of oxygen to improve bioluminescence flux by bacteria with isoflurane as well as with ketamine/xylazine anesthetics. As a conclusion, we recommend the use of isoflurane anesthetic with oxygen to increase the bioluminescence sensitivity in this kind of study.


Assuntos
Anestesia/métodos , Anestésicos Dissociativos/farmacologia , Isoflurano/farmacologia , Ketamina/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Xilazina/farmacologia , Animais , Medições Luminescentes , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...