Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
J Robot Surg ; 18(1): 120, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38492073

RESUMO

Robotic-assisted TKA (RATKA) is a rapidly emerging technique that has been shown to improve precision and accuracy in implant alignment in TKA. Robotic-assisted TKA (RATKA) uses computer software to create a three-dimensional model of the patient's knee. Different types of preoperative imaging, including radiographs and CT scans, are used to create these models, each with varying levels of radiation exposure. This study aims to determine the radiation dose associated with each type of imaging used in RATKA, to inform patients of the potential risks. A retrospective search of our clinical radiology and arthroplasty database was conducted to identify 140 knees. The patients were divided into three groups based on the type of preoperative imaging they received: (1) CT image-based MAKO Protocol, (2) Antero-posterior long leg alignment films (LLAF), (3) standard AP, lateral, and skyline knee radiographs. The dose of CT imaging technique for each knee was measured using the dose-length product (DLP) with units of mGycm2, whereas the measurement for XRAY images was with the dose area product (DAP) with units of Gycm2. The mean radiation dose for patients in the CT (MAKO protocol) image-based group was 1135 mGy.cm2. The mean radiation dose for patients in the LLAF group was 3081 Gycm2. The mean radiation dose for patients undergoing knee AP/lateral and skyline radiographs was the lowest of the groups, averaging 4.43 Gycm2. Through an ANOVA and post hoc analysis, the results between groups was statistically significant. In this study, we found a significant difference in radiation exposure between standard knee radiographs, LLAF and CT imaging. Nonetheless, the radiation dose for all groups is still within acceptable safety limits.


Assuntos
Artroplastia do Joelho , Exposição à Radiação , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Retrospectivos , Exposição à Radiação/prevenção & controle
2.
Knee ; 48: 1-7, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38461736

RESUMO

INTRODUCTION: There is growing interest in the use of robotic TKA to improve accuracy of component positioning in Total Knee Arthroplasty (TKA). The aim of this study was to investigate the accuracy of implant component position using the ROSA® knee system with specific reference to Joint Line Height, Patella Height and Posterior Condylar Offset (PCO). METHODS: This was a retrospective review of a prospectively-maintained database of the initial 100 consecutive TKAs performed by a high volume surgeon using the ROSA® knee system. Both the image-based and imageless workflow were used and two prosthesis types were implanted. To determine the accuracy of component positioning, the immediate post-operative radiograph was reviewed and compared with the immediate pre-operative radiograph with regards to Joint Line Height, Patella Height and Posterior Condylar Offset. RESULTS: 100 consecutive patients undergoing TKA using the ROSA system were included; mean age 70 years (range 49-95 years). Mean change in joint line height was 0.2 mm, patella height (Insall-Salvati ratio) 0.01 and posterior condylar offset 0.02 mm; there was no statistically significant difference between the pre and post-operative values. No difference was demonstrated between image-based or imageless workflows, or between implant design (Persona versus Vanguard) regarding joint line height, patella height and PCO. CONCLUSION: This study validates the use of the ROSA® knee system in accurately restoring Joint Line Height, Patella Height and Posterior Condylar Offset in TKA surgery. No significant differences were found between imageless and image-based groups, or between implant designs (Persona versus Vanguard).


Assuntos
Artroplastia do Joelho , Patela , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/instrumentação , Idoso , Feminino , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Patela/cirurgia , Patela/diagnóstico por imagem , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Articulação do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem
3.
J Robot Surg ; 18(1): 2, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38175317

RESUMO

BACKGROUND: The rise of robotics in orthopaedic training, driven by the demand for better training outcomes and patient care, presents specific challenges for junior trainees due to its novelty and steep learning curve. This paper explores how orthopaedic trainees perceive and adopt robotic-assisted lower limb arthroplasty. METHODS: The study utilised the UTUAT model questionnaire as the primary data collection tool, employing targeted questions on a five-point Likert scale to efficiently gather responses from a large number of participants. Data analysis was conducted using partial least squares (PLS), a well-established method in previous technology acceptance research. RESULT: The findings indicate a favourable attitude amongst trainees towards adopting robotic technology in orthopaedic training. They acknowledge the potential advantages of improved surgical precision and patient outcomes through roboticassisted procedures. Social factors, including the views of peers and mentors, notably influence trainees' decision-making. However, the availability of resources and expert mentors did not appear to have a significant impact on trainees' intention to use robotic technology. CONCLUSION: The study contributes to the understanding of factors influencing trainees' interest in robotic surgery and emphasises the importance of creating a supportive environment for its adoption.


Assuntos
Ortopedia , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Artroplastia , Extremidade Inferior , Inquéritos e Questionários
4.
J Robot Surg ; 18(1): 33, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38231299

RESUMO

There is increasing adoption of robotic surgical technology in Total Knee Arthroplasty. The ROSA® knee system can be used in either image-based mode (using pre-operative calibrated radiographs) or imageless modes (using intra-operative bony registration). The Mako knee system is an image-based system (using a pre-operative CT scan). This study aimed to compare surgical accuracy between the ROSA and Mako systems with specific reference to joint line height, patella height, posterior condylar offset and tibial slope. This was a retrospective review of a prospectively collected data of the initial 50 consecutive ROSA TKAs and the initial 50 consecutive Mako TKAs performed by two high-volume surgeons. To determine the accuracy of component positioning, the immediate post-operative radiograph was reviewed and compared with the immediate pre-operative radiograph with regards to joint line height (JLH), patella height (PH), tibial slope (TS) and posterior condylar offset (PCO). Mean difference between pre- and post-operative radiographs using the ROSA knee system of joint line height was 0.47 mm (SD 0.95) posterior condylar offset 0.16 mm (SD 0.76), tibial slope 0.9 degrees (SD 1.6) and patella height 0.01 (SD 0.05). Mean difference using the MAKO knee system of joint line height was 0.26 (SD 1.08), posterior condylar offset -0.26 mm (SD 0.78), tibial slope 1.8 degrees and patella height 0.03. No significant difference was demonstrated between the accuracy of component positioning of the ROSA or MAKO knee systems. Our study is the first study to compare the accuracy of the ROSA and MAKO knee systems in total knee arthroplasty. Both systems are highly accurate in restoring native posterior condylar offset, joint line height, tibial slope and patella height in TKA with no significant difference demonstrated between the two groups.


Assuntos
Artroplastia do Joelho , Procedimentos Cirúrgicos Robóticos , Robótica , Rosa , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Tíbia
5.
Bone Joint Res ; 12(9): 571-579, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37727965

RESUMO

Aims: The aim of this study was to identify the optimal lip position for total hip arthroplasties (THAs) using a lipped liner. There is a lack of consensus on the optimal position, with substantial variability in surgeon practice. Methods: A model of a THA was developed using a 20° lipped liner. Kinematic analyses included a physiological range of motion (ROM) analysis and a provocative dislocation manoeuvre analysis. ROM prior to impingement was calculated and, in impingement scenarios, the travel distance prior to dislocation was assessed. The combinations analyzed included nine cup positions (inclination 30-40-50°, anteversion 5-15-25°), three stem positions (anteversion 0-15-30°), and five lip orientations (right hip 7 to 11 o'clock). Results: The position of the lip changes the ROM prior to impingement, with certain combinations leading to impingement within the physiological ROM. Inferior lip positions (7 to 8 o'clock) performed best with cup inclinations of 30° and 40°. Superior lip positions performed best with cup inclination of 50°. When impingement occurs in the plane of the lip, the lip increases the travel distance prior to dislocation. Inferior lip positions led to the largest increase in jump distance in a posterior dislocation provocation manoeuvre. Conclusion: The lip orientation that provides optimal physiological ROM depends on the orientation of the cup and stem. For a THA with stem anteversion 15°, cup inclination 40°, and cup anteversion 15°, the optimal lip position was posterior-inferior (8 o'clock). Maximizing jump distance prior to dislocation while preventing impingement in the opposite direction is possible with appropriate lip positioning.

6.
Bone Joint J ; 103-B(9): 1479-1487, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34465151

RESUMO

AIMS: The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs). METHODS: We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression. RESULTS: A total of 213,146 THAs were included in the analysis. Overall, 2,997 revisions were recorded, 1,569 in THAs with a flat liner and 1,428 in THAs using an asymmetric liner. Flat liner THAs had a higher risk of revision for any reason than asymmetric liner THAs when implanted through a Hardinge/anterolateral approach (hazard ratio (HR) 1.169, 95% confidence interval (CI) 1.022 to 1.337) and through a posterior approach (HR 1.122, 95% CI 1.108 to 1.346). There was no increased risk of revision for aseptic loosening when asymmetric liners were used for any surgical approach. A separate analysis of the three most frequently used crosslinked polyethylene liners was in agreement with this finding. When analyzing THAs with flat liners only, THAs implanted through a Hardinge/anterolateral approach were associated with a reduced risk of revision for instability compared to posterior approach THAs (HR 0.561 (95% CI 0.446 to 0.706)). When analyzing THAs with an asymmetric liner, there was no significant difference in the risk of revision for instability between the two approaches (HR 0.838 (95% CI 0.633 to 1.110)). CONCLUSION: For THAs implanted through the posterior approach, the use of asymmetric liners reduces the risk of revision for instability and revision for any reason. In THAs implanted through a Hardinge/anterolateral approach, the use of an asymmetric liner was associated with a reduced risk of revision. The effect on revision for instability was less pronounced than in the posterior approach. Cite this article: Bone Joint J 2021;103-B(9):1479-1487.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Polietileno/química , Desenho de Prótese , Reoperação/estatística & dados numéricos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Sistema de Registros
7.
Artigo em Inglês | MEDLINE | ID: mdl-34337286

RESUMO

Computer-assisted total hip arthroplasty (THA) is known to improve implantation precision, but clinical data demonstrating an improvement in survivorship and patient-reported outcome measures (PROMs) are lacking. Our aim was to compare the risk of revision, PROMs, and patient satisfaction between cohorts who underwent THA with and without the use of computer guidance. METHODS: We used the data set and linked PROM data of the National Joint Registry of England, Wales, Northern Ireland and the Isle of Man. Our sample included THAs performed for osteoarthritis using cementless acetabular components from a single manufacturer (cementless and hybrid THAs). An additional analysis was performed limiting the sample size to cementless-only THAs. The primary end point was revision (any component) for any reason. Kaplan-Meier survivorship analysis and an adjusted Cox proportional-hazards model were used. RESULTS: There were 41,683 non-computer-guided and 871 (2%) computer-guided cases included in our analysis of the cementless and hybrid group. There were 943 revisions in the non-computer-guided group and 7 in the computer-guided group. The cumulative revision rate at 10 years was 3.88% (95% confidence interval [CI]: 3.59% to 4.18%) for the non-computer-guided group and 1.06% (95% CI: 0.45% to 2.76%) for the computer-guided group. The Cox proportional-hazards model yielded a hazard ratio of 0.45 (95% CI: 0.21 to 0.96; p = 0.038). In the analysis of the cementless-only group, the cumulative revision rate at 10 years was 3.99% (95% CI: 3.62% to 4.38%) and 1.20% (95% CI: 0.52% to 3.12%) for the 2 groups, respectively. The Cox proportional-hazards model yielded a hazard ratio of 0.47 (95% CI: 0.22 to 1.01; p = 0.053). There was no significant difference in the 6-month Oxford Hip Score, the EuroQol-5 Dimension (EQ-5D) and EQ-VAS (Visual Analogue Scale) scores, and patient-reported success rates. Patient satisfaction (single-item satisfaction outcome measure) was higher in the computer-guided group, but this finding was limited by a reduced number of responses. CONCLUSIONS: In our analysis, the use of computer-guided surgery was associated with a lower rate of revision at mean follow-up of 5.6 years. This finding was upheld when the sample was restricted to cementless-only THAs. Causality cannot be inferred in view of the observational nature of the study, and additional studies are recommended to validate these findings. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

8.
J Clin Orthop Trauma ; 15: 60-64, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33717918

RESUMO

AIMS: Metaphyseal cones and sleeves are components used in revision knee arthroplasty to ensure load transfer, encourage bone on-growth and prevent stress shielding. Additive manufacturing of titanium alloy implants is a novel technique with limited clinical outcome reports in the literature. The aim of this study was to determine radiographic evidence of osseointegration and early results of a single manufacturer porous titanium metaphyseal components in the proximal tibia. METHODS: We retrospectively reviewed the prospectively collected database of two institutions. Patients who underwent revision knee arthroplasty using porous titanium components by a single manufacturer were identified. Immediate post-operative and latest follow-up radiographs were independently analysed by 2 reviewers to determine metaphyseal bone contact and level of osseointegration in relevant Knee Society Radiographic Evaluation and Scoring System zones. RESULTS: 22 patients (15 males; 7 females) with a mean age of 71 (49-92) years were included. The mean follow-up period was 14 months (2-44 months). Cones were used in 16 patients and sleeves in 6. Interobserver reliability assessment showed substantial agreement (weighted Kappa 0.71, (95% CI: 0.60, 0.81). There was significant correlation between the bone contact in the immediate postop radiograph and osseointegration at final follow-up (kendall's tau-b: 0.698, p < 0.001). Infection free prosthetic joint survival was 20/22 at final follow-up. CONCLUSION: Porous titanium metaphyseal components produced with additive manufacturing provided excellent osseointegration and no early clinical failures. Partial or complete contact of the cone with native bone in the immediate postoperative radiograph resulted in osseointegration in all cases.

9.
Cartilage ; 12(2): 226-236, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-30525942

RESUMO

OBJECTIVE: The study aims were to determine whether BST-CarGel, a chitosan scaffold for cartilage repair, can be mixed with bone marrow aspirate concentrate (BMAC) to create a cell seeded implant with comparative properties to standard BST-CarGel mixed with blood. DESIGN: Whole blood and bone marrow were harvested from 12 patients who underwent cartilage repair surgery using BMAC after informed consent. A validated in vitro testing model was used to assess the following 6 conditions: (1) BST-CarGel mixed with whole blood (CG-WB), (2) BST-CarGel mixed with bone marrow (CG-BM), (3) BST-CarGel mixed with bone marrow concentrate (CG-BMAC), (4) whole blood (WB), (5) bone marrow (BM), and (6) bone marrow concentrate and batroxobin (BMAC-BTX). Cell retention and viability within the BST-CarGel/BMAC clots were investigated. RESULTS: In our study, BM and BMAC (processed using the Harvest, SmartPrep2 system and reactivated with batroxibin) when combined with BST-CarGel produced a product that had similar clot contraction, macroscopic properties, and histological appearance to standard BSTCarGel mixed with blood. Mononucleated cells from the BMAC were retained within the scaffold and remained viable until clot dissolution in vitro. CONCLUSIONS: By combining BST-CarGel with BMAC in the manner described, bone marrow-derived mononucleated cells can be retained within the chondral defect potentially negating the need for microfracture. Further in vivo work is required to confirm these potential benefits and determine if this combination will result in more durable cartilage repair and improved clinical outcomes.


Assuntos
Materiais Biocompatíveis/uso terapêutico , Medula Óssea , Cartilagem Articular/cirurgia , Quitosana/uso terapêutico , Desenho de Prótese/métodos , Artroplastia Subcondral/métodos , Doenças das Cartilagens/cirurgia , Técnicas de Cultura de Células , Estudos de Viabilidade , Fraturas de Estresse/cirurgia , Humanos , Técnicas In Vitro , Alicerces Teciduais , Resultado do Tratamento
10.
Bone Joint Res ; 9(9): 563-571, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33005395

RESUMO

AIMS: To investigate the effect of polyethylene manufacturing characteristics and irradiation dose on the survival of cemented and reverse hybrid total hip arthroplasties (THAs). METHODS: In this registry study, data from the National Joint Registry of England, Wales, Northern Ireland and the Isle of Man (NJR) were linked with manufacturing data supplied by manufacturers. The primary endpoint was revision of any component. Cox proportional hazard regression was a primary analytic approach adjusting for competing risk of death, patient characteristics, head composition, and stem fixation. RESULTS: A total of 290,770 primary THAs were successfully linked with manufacturing characteristics. Overall 4,708 revisions were analyzed, 1,260 of which were due to aseptic loosening. Total radiation dose was identified as a risk factor and included in the Cox model. For statistical modelling of aseptic loosening, THAs were grouped into three categories: G1 (no radiation); G2 ( > 0 to < 5 Mrad); and G3 ( ≥ 5 Mrad). G1 had the worst survivorship. The Cox regression hazard ratio for revision due to aseptic loosening for G2 was 0.7 (95% confidence interval (CI) 0.58 to 0.83), and for G3 0.4 (95% CI 0.30 to 0.53). Male sex and uncemented stem fixation were associated with higher risk of revision and ceramic heads with lower risk. CONCLUSION: Polyethylene irradiation was associated with reduced risk of revision for aseptic loosening. Radiation doses of ≥ 5 Mrad were associated with a further reduction in risk.Cite this article: Bone Joint Res 2020;9(9):563-571.

11.
JB JS Open Access ; 5(2): e0075, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33123668

RESUMO

BACKGROUND: Modern bearing surface options have increased implant survivorship after total hip arthroplasty (THA). We utilized data from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) to analyze implant survivorship after THAs with uncemented acetabular components with different bearing combinations. METHODS: Polyethylene (PE) manufacturing properties supplied by the manufacturers were used to subdivide the NJR data set into cross-linked PE (XLPE) and conventional PE groups. Overall and cause-specific revisions for various bearing combinations were analyzed using Kaplan-Meier and multivariate Cox proportional hazard regression survival analyses. RESULTS: Of 420,339 primary THAs, 8,025 were revised during an average follow-up period of 4.4 years (maximum, 13.3 years). In the Cox regression model with metal on conventional PE as the reference, the lowest risk of revision for any reason was for ceramicized metal on XLPE (hazard ratio [HR] = 0.58, 95% confidence interval [CI] = 0.48, 0.71), followed by ceramic on XLPE (HR = 0.66, 95% CI = 0.60, 0.72), ceramic on PE (HR = 0.74, 95% CI = 0.66, 0.82), ceramic on ceramic (HR = 0.77, 95% CI = 0.72, 0.82), and metal on XLPE (HR = 0.81, 95% CI = 0.76, 0.87). A similar pattern was observed when patients under the age of 55 years were analyzed independently. Younger age, male sex, and cementless stem fixation were associated with a higher risk of revision. CONCLUSIONS: In a fully adjusted model, ceramicized metal on XLPE and ceramic on XLPE were associated with the lowest risk of revision for any reason. This finding was sustained when patients under the age of 55 years were analyzed independently. On the basis of the NJR data set, use of XLPE markedly reduces the risk of revision. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

12.
Bone Joint J ; 102-B(3): 400, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32114821
13.
Bone Joint J ; 102-B(1): 90-101, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31888362

RESUMO

AIMS: The aim of this study was to identify the effect of the manufacturing characteristics of polyethylene acetabular liners on the survival of cementless and hybrid total hip arthroplasty (THA). METHODS: Prospective cohort study using linked National Joint Registry (NJR) and manufacturer data. The primary endpoint was revision for aseptic loosening. Cox proportional hazard regression was the primary analytical approach. Manufacturing variables included resin type, crosslinking radiation dose, terminal sterilization method, terminal sterilization radiation dose, stabilization treatment, total radiation dose, packaging, and face asymmetry. Total radiation dose was further divided into G1 (no radiation), G2 (> 0 Mrad to < 5 Mrad), G3 (≥ 5 Mrad to < 10 Mrad), and G4 (≥ 10 Mrad). RESULTS: A total of 5,329 THAs were revised, 1,290 of which were due to aseptic loosening. Total radiation dose, face asymmetry, and stabilization treatments were found to significantly affect implant survival. G1 had the highest revision risk for any reason and for aseptic loosening and G3 and G4 the lowest. Compared with G1, the adjusted hazard ratio for G2 was 0.74 (95% confidence interval (CI) 0.64 to 0.86), G3 was 0.36 (95% CI 0.30 to 0.43), and G4 was 0.38 (95% CI 0.31 to 0.47). The cumulative incidence of revision for aseptic loosening at 12 years was 0.52 and 0.54 per 100 THAs for G3 and G4, respectively, compared with 1.95 per 100 THAs in G1. Asymmetrical liners had a lower revision risk due to aseptic loosening and reasons other than aseptic loosening compared with symmetric (flat) liners. In G3 and G4, stabilization with vitamin E and heating above melting point performed best. CONCLUSION: Polyethylene liners with a total radiation dose of ≥ 5 Mrad, an asymmetrical liner face, and stabilization with heating above the melting point demonstrate best survival. Cite this article: Bone Joint J 2020;102-B(1):90-101.


Assuntos
Artroplastia de Quadril/normas , Prótese de Quadril/normas , Polietileno , Adulto , Idoso , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/estatística & dados numéricos , Tecnologia Biomédica , Feminino , Prótese de Quadril/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese/normas , Desenho de Prótese/estatística & dados numéricos , Falha de Prótese , Reoperação/estatística & dados numéricos , Fatores de Risco
14.
Arthroscopy ; 36(3): 648-657, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31784365

RESUMO

PURPOSE: To investigate the effect of delayed application of leukocyte-rich platelet-rich plasma (PRP) on rotator cuff repair results as assessed by outcome scores and imaging at one year. METHODS: Patients with a symptomatic rotator cuff tear awaiting arthroscopic repair were approached to take part in the study. Final eligibility for the study was confirmed at the time of surgery. A total of 97 patients were randomized to an ultrasound guided injection of leukocyte-rich PRP or normal saline between 10 and 14 days postsurgery. A total of 87 patients completed clinical evaluation and underwent magnetic resonance imaging imaging at 1 year. Outcome scores included the American Shoulder and Elbow Score, Constant score, Western Ontario Rotator Cuff Index, and the Disabilities of the Arm, Shoulder and Hand Score. Structural integrity of the repair was assessed according to the Sugaya grading. Muscle fatty infiltration was assessed on magnetic resonance imaging using the Goutallier classification. RESULTS: At 1 year postsurgery, there was no significant difference between the treatment groups on any of the patient-reported outcome measures or Constant score. On postoperative imaging analysis, there was no difference in the retear rates (Sugaya 4 and 5) between the groups (21% in control group vs 15.3% in PRP group). Fatty infiltration on postoperative imaging was found to be significantly higher in the normal saline group compared with the PRP group (Kendall's tau-b P = .032). CONCLUSIONS: The delayed application of PRP postrotator cuff repair did not improve function as measured by patient-reported outcome measures and Constant score at 1 year postoperatively. LEVEL OF EVIDENCE: Level II, prospective randomized therapeutic trial.


Assuntos
Artroscopia , Leucócitos , Plasma Rico em Plaquetas , Lesões do Manguito Rotador/cirurgia , Adulto , Idoso , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Período Pós-Operatório , Estudos Prospectivos , Tempo para o Tratamento
15.
J Pediatr Orthop ; 39(6): e472-e477, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30702640

RESUMO

AIMS: Our study aims to review the outcomes of conservative and interventional management of simple bone cysts (SBC) in the humerus. METHODS: We retrospectively reviewed our center's prospectively collected database. All patients with a diagnosis of a humeral SBC and a minimum of 1-year follow-up or complete healing and discharge within the first year were included. Cyst radiographic measurements were collected for all patients with available radiographs. A successful outcome included fully or partially healed cysts with persistent and recurrent cysts marked as unsuccessful. RESULTS: In total, 91 patients were included in the study. Within the observational group, 44 patients (95.7%) achieved a successful outcome versus 38 patients (84.4%) in the interventional group. The 15/61 (25%) patients who were treated with observation at presentation required intervention at a later stage. The 9/30 (30%) of patients who had intervention at presentation required further additional intervention. Seven patients (11%) presenting with a fracture through a SBC went on to complete consolidation of the cystic lesion following the injury at a mean of 92.9 days (maximum, 176 d). CONCLUSIONS: We observed similar outcomes with conservative and interventional management in our retrospective series. We recommend observational management when a radiologic diagnosis is possible with intervention reserved for cases of diagnostic uncertainty and intrusive symptoms. LEVEL OF EVIDENCE: Level III-a retrospective case comparison study.


Assuntos
Cistos Ósseos/terapia , Fraturas do Úmero/terapia , Úmero/patologia , Adolescente , Adulto , Cistos Ósseos/diagnóstico por imagem , Estudos de Casos e Controles , Criança , Feminino , Humanos , Masculino , Radiografia/métodos , Estudos Retrospectivos , Conduta Expectante , Adulto Jovem
16.
Knee ; 25(5): 866-873, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30207280

RESUMO

BACKGROUND: We report the first results of a new low-profile titanium locking plate for fixation of opening wedge high tibial osteotomy (OWHTO). Short spacer plates have been associated with a high hardware complication rate, whilst fixed angle locking plates have been associated with a high incidence of soft tissue irritation. This plate aims to achieve stable fixation whilst maintaining a low profile, allowing space for combined procedures. METHODS: All patients undergoing OWHTO with the Activmotion plate were retrospectively reviewed. Patients were allowed to progress to full weight bearing after two weeks. Radiographic assessment included the medial proximal tibial angle (MPTA) and posterior tibial slope at six weeks and then three monthly until union. All complications were recorded. RESULTS: Thirty-seven patients with 40 OWHTOs were included in the study. The mean MPTA increased from 85.2 preoperatively to 91.9 postop. Tibial slope changed from 5.2 to 4.2°. The correction was sustained until union with no loss of correction in the MPTA (median change 0.0, 95% CI for median (-0.25, 0.4)) or tibial slope (mean increase 0.32, 95% CI (-0.02, 0.67)). CONCLUSIONS: In this pilot study the Activmotion plate raised no safety concerns with regard to implant related adverse events or loss of initial correction. Early rehabilitation with immediate partial weight bearing was possible and all cases proceeded to osteotomy union with the exception of one case that needed to undergo bone grafting with implant retention. Premature removal of the implant was necessary in four cases due to symptomatic hardware irritation.


Assuntos
Placas Ósseas , Osteoartrite do Joelho/cirurgia , Osteotomia/métodos , Radiografia/métodos , Tíbia/cirurgia , Adulto , Idoso , Transplante Ósseo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico , Osteoartrite do Joelho/fisiopatologia , Projetos Piloto , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Suporte de Carga , Adulto Jovem
17.
Knee ; 25(5): 959-965, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29891210

RESUMO

Malunited tibial plateau fractures are a surgical challenge. We report a case of a malunion following a Schatzker V tibial plateau fracture with a biplanar deformity of the medial hemi-plateau. This was treated with an intra-articular osteotomy and biplanar restoration of the medial hemi-plateau using patient-specific guides and 3-dimensional planning based on computed tomography (CT) images. The mechanical axis was paradoxically preserved and the lateral compartment showed evidence of overload and degeneration secondary to a malunited tibial spine bone block providing varus/valgus constraint. This was arthroscopically resected at the same sitting. The tibial plateau was restored to the desirable height with a vast improvement in function and pain levels.


Assuntos
Artroscopia/métodos , Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas Mal-Unidas/cirurgia , Articulação do Joelho/cirurgia , Osteotomia/métodos , Fraturas da Tíbia/cirurgia , Fraturas Mal-Unidas/diagnóstico , Humanos , Imageamento Tridimensional , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Tíbia/diagnóstico por imagem , Tíbia/lesões , Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
18.
J Arthroplasty ; 31(8): 1849-56, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26989031

RESUMO

BACKGROUND: Lack of fracture movement could be a potential cause of periprosthetic femoral fracture (PFF) fixation failures. This study aimed to test whether the use of distal far cortical locking screws reduces the overall stiffness of PFF fixations and allows an increase in fracture movement compared to standard locking screws while retaining the overall strength of the PFF fixations. METHODS: Twelve laboratory models of Vancouver type B1 PFFs were developed. In all specimens, the proximal screw fixations were similar, whereas in 6 specimens, distal locking screws were used, and in the other six specimens, far cortical locking screws. The overall stiffness, fracture movement, and pattern of strain distribution on the plate were measured in stable and unstable fractures under anatomic 1-legged stance. Specimens with unstable fracture were loaded to failure. RESULTS: No statistical difference was found between the stiffness and fracture movement of the two groups in stable fractures. In the unstable fractures, the overall stiffness and fracture movement of the locking group was significantly higher and lower than the far cortical group, respectively. Maximum principal strain on the plate was consistently lower in the far cortical group, and there was no significant difference between the failure loads of the 2 groups. CONCLUSION: The results indicate that far cortical locking screws can reduce the overall effective stiffness of the locking plates and increase the fracture movement while maintaining the overall strength of the PFF fixation construct. However, in unstable fractures, alternative fixation methods, for example, long stem revision might be a better option.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Periprotéticas/cirurgia , Desenho de Prótese , Fenômenos Biomecânicos , Fêmur , Humanos , Modelos Teóricos , Falha de Prótese , Estresse Mecânico
19.
J Orthop Surg (Hong Kong) ; 23(3): 379-82, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26715723

RESUMO

PURPOSE: To review outcome of 44 children who underwent conservative or surgical treatment for spondylolysis or spondylolisthesis. METHODS: Records of 25 male and 19 female children aged 5 to 14 (mean, 10.2) years who underwent conservative (n=39) or surgical (n=5) treatment for spondylolysis (n=19) or spondylolisthesis (n=25) were reviewed. Conservative treatment involved application of a thoracolumbosacral orthotic brace for all day except bedtime until symptoms resolved and then physiotherapy including exercises to strengthen the abdominal and back muscles and stretching exercises of the hamstrings and hip flexors. Surgery (instrumented posterolateral fusion [n=4] or Wiltse posterolateral fusion [n=1]) with allografts was indicated in patients with refractory pain (n=2) or nerve root irritation (n=1) and in patients with iatrogenic spondylolisthesis (n=2), followed by application of the brace for 3 months and then physiotherapy. Outcome was assessed using the Seitsalo scoring system. RESULTS: The mean follow-up period was 6.5 (range, 3-10) years. No patient developed any postoperative complication. Outcome was excellent in 35 patients, good in 8, and fair in one. All 5 patients who underwent posterolateral fusion for refractory spondylolisthesis achieved good outcome. In 11 patients with spondylolysis, the pars defect healed. None of the spondylolysis progressed to spondylolisthesis. All displacements remained stable, without any progression. CONCLUSION: Conservative treatment is effective for most patients with spondylolysis or spondylolisthesis. Instrumented posterolateral fusion is indicated in patients with persistent symptoms and for iatrogenic cases.


Assuntos
Terapia por Exercício/métodos , Fusão Vertebral/métodos , Espondilolistese/terapia , Espondilólise/terapia , Adolescente , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
20.
Comput Aided Surg ; 20(1): 7-13, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26290417

RESUMO

Optimal component alignment in total knee arthroplasty has been associated with better functional outcome as well as improved implant longevity. The ability to align components optimally during minimally invasive (MIS) total knee replacement (TKR) has been a cause of concern. Computer navigation is a useful aid in achieving the desired alignment although it is limited by the error during the manual registration of landmarks. Our study aims to compare the registration process error between a standard and a MIS surgical approach. We hypothesized that performing the registration error via an MIS approach would increase the registration process error. Five fresh frozen lower limbs were routinely prepared and draped. The registration process was performed through an MIS approach. This was then extended to the standard approach and the registration was performed again. Two surgeons performed the registration process five times with each approach. Performing the registration process through the MIS approach was not associated with higher error compared to the standard approach in the alignment parameters of interest. This rejects our hypothesis. Image-free navigated MIS TKR does not appear to carry higher risk of component malalignment due to the registration process error. Navigation can be used during MIS TKR to improve alignment without reduced accuracy due to the approach.


Assuntos
Artroplastia do Joelho/métodos , Erros Médicos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Cirurgia Assistida por Computador/métodos , Cadáver , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...