1.
IEEE Trans Biomed Eng ; 59(10): 2737-43, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22996723

RESUMO

The association between anisotropic magnetoresistive (AMR) sensor and AC biosusceptometry (ACB) to evaluate gastrointestinal motility is presented. The AMR-ACB system was successfully characterized in a bench-top study, and in vivo results were compared with those obtained by means of simultaneous manometry. Both AMR-ACB and manometry techniques presented high temporal cross correlation between the two periodicals signals . The contraction frequencies using AMR-ACB were 73.9 ± 7.6 mHz and using manometry were 73.8 ± 7.9 mHz during the baseline . The amplitude of contraction using AMR-ACB was 396 ± 108 µT·s and using manometry were 540 ± 198 mmHg·s during the baseline. The amplitudes of signals for AMR-ACB and manometric recordings were similarly increased to 86.4% and 89.3% by neostigmine, and also decreased to 27.2% and 21.4% by hyoscine butylbromide in all animals, respectively. The AMR-ACB array is nonexpensive, portable, and has high-spatiotemporal resolution to provide helpful information about gastrointestinal tract.


Assuntos
Motilidade Gastrointestinal/fisiologia , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Processamento de Sinais Assistido por Computador , Animais , Anisotropia , Cães , Campos Eletromagnéticos , Desenho de Equipamento , Manometria/instrumentação , Manometria/métodos , Modelos Teóricos
2.
Artigo em Inglês | MEDLINE | ID: mdl-21096717

RESUMO

The alternate current biosusceptometry (ACB) is a biomagnetic technique used to study some physiological parameters associated with gastrointestinal (GI) tract. For this purpose it applies an AC magnetic field and measures the response originating from magnetic marks or tracers. This paper presents an equipment based on the ACB which uses anisotropic magnetoresistive (AMR) sensors and an inexpensive electronic support. The ACB-AMR developed consists of a square array of 6×6 sensors arranged in a first-order gradiometer configuration with one reference sensor. The equipment was applied to capture magnetic images of different phantoms and to acquire gastric contraction activity of healthy rats. The results show a reasonable sensitivity and spatial-temporal resolution, so that it may be applied for imaging of phantoms and signal acquisition of the GI tract of small animals.


Assuntos
Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Trato Gastrointestinal , Magnetismo/instrumentação , Magnetismo/métodos , Animais , Imagens de Fantasmas , Ratos
3.
Artigo em Inglês | MEDLINE | ID: mdl-18002430

RESUMO

A novel instrumentation using anisotropic magnetoresistive (AMR) sensors associated with magnetic coils excitation was developed to evaluate gastrointestinal tract motility parameters. The susceptometer has four sensors that were used to measure the gastric activity contractions (GAC) in anaesthetized dogs, its performance was evaluated by manometry with good results.


Assuntos
Motilidade Gastrointestinal , Algoritmos , Animais , Anisotropia , Técnicas Biossensoriais , Digestão , Cães , Condutividade Elétrica , Desenho de Equipamento , Feminino , Esvaziamento Gástrico , Magnetismo , Manometria/instrumentação , Manometria/métodos , Radiação Ionizante
4.
Artigo em Inglês | MEDLINE | ID: mdl-18002613

RESUMO

Anisotropic Magnetoresistive (AMR) sensors shows a new possibility to detect magnetic fields produced by magnetic particles present in the gastrointestinal (GI) tract. A system that uses excitation and detection of magnetic field was developed using AMR sensor. A magnetic flux concentrator was also studied to increase the sensitivity of AMR in this work.


Assuntos
Trato Gastrointestinal , Magnetismo , Imagens de Fantasmas
5.
Pharm Res ; 23(8): 1809-16, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16858651

RESUMO

PURPOSE: To employ the AC Biosusceptometry (ACB) technique to evaluate in vitro and in vivo characteristics of enteric coated magnetic hydroxypropyl methylcellulose (HPMC) capsules and to image the disintegration process. MATERIALS AND METHODS: HPMC capsules filled with ferrite (MnFe2O4) and coated with Eudragit were evaluated using USP XXII method and administered to fasted volunteers. Single and multisensor ACB systems were used to characterize the gastrointestinal (GI) motility and to determine gastric residence time (GRT), small intestinal transit time (SITT) and orocaecal transit time (OCTT). Mean disintegration time (t50) was quantified from 50% increase of pixels in the imaging area. RESULTS: In vitro and in vivo performance of the magnetic HPMC capsules as well as the disintegration process were monitored using ACB systems. The mean disintegration time (t50) calculated for in vitro was 25+/-5 min and for in vivo was 13+/-5 min. In vivo also were determined mean values for GRT (55+/-19 min), SITT (185+/-82 min) and OCTT (240+/-88 min). CONCLUSIONS: AC Biosusceptometry is a non-invasive technique originally proposed to monitoring pharmaceutical dosage forms orally administered and to image the disintegration process.


Assuntos
Compostos Férricos/química , Trato Gastrointestinal/fisiologia , Metilcelulose/análogos & derivados , Adulto , Cápsulas , Ceco/fisiologia , Excipientes , Feminino , Compostos Férricos/administração & dosagem , Motilidade Gastrointestinal/fisiologia , Trânsito Gastrointestinal/fisiologia , Humanos , Concentração de Íons de Hidrogênio , Derivados da Hipromelose , Valva Ileocecal/fisiologia , Intestino Delgado/fisiologia , Magnetismo , Masculino , Metilcelulose/química , Ácidos Polimetacrílicos , Solubilidade , Comprimidos com Revestimento Entérico
SELEÇÃO DE REFERÊNCIAS