Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Prosthodont ; 32(9): 854-860, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36651602

RESUMO

PURPOSE: The use of porcelain laminate veneers (PLVs) is a minimally invasive technique that is often used in restorative dentistry due to esthetic considerations. The aim of this study was to evaluate PLVs according to the Fédération Dentaire Internationale (FDI) World Dental Federation clinical criteria. MATERIALS AND METHODS: This clinical study included 11 patients (7 female and 4 male) who had been admitted to the Usak University Faculty of Dentistry between February 2019 and February 2021. Before taking part in the study, patients were informed about alternative treatment procedure options. A total of 30 PLVs were fabricated and cemented, and patients were evaluated according to the FDI criteria (with a follow-up after 2 years). RESULTS: Restorations were evaluated by two trained researchers. During the follow-up evaluation, no fractures or cracks were observed in any restoration. Further, 73% (n = 22) of the PLVs had perfect marginal adaptation and only 27% (n = 8) had small marginal fractures that could be removed by polishing. Moreover, 57% (n = 17) of the PLVs were evaluated as a good color match (no difference in shade and/or translucency), whereas 33% (n = 13) had only minor deviations. In periodontal examinations, 23% (n = 7) of the PLVs had no plaque, inflammation, or pockets, whereas 77% (n = 23) had minor plaque inflammation and no pocket development. CONCLUSIONS: As there were no fractures, fails, or need for removal of the restorations after 2 years, PLVs showed clinically satisfactory performance. The performance of PLVs can be considered highly favorable due to the minimally invasive and periodontally-compatible nature, with a good color match when carefully planned.


Assuntos
Porcelana Dentária , Facetas Dentárias , Humanos , Masculino , Feminino , Estética Dentária , Odontologia , Inflamação
2.
Microsc Res Tech ; 84(9): 2166-2175, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33931911

RESUMO

The purpose of this study was to elucidate the origin of initiation of hybrid layer biodegradation. Ninety caries-free human third molars were divided into three surface groups: enamel, dentin, and NaOCl-treated dentin. (n = 30/group) Each group was divided into three subgroups (n = 10/group) of luting resin materials with etch-and-rinse; self-etch and self-adhesive systems. Resin composite blocks and sticks were fabricated and adhered onto dentin and enamel surfaces. The bond strength values were evaluated with micro shear test and statistical analysis were made. On the other hand, teeth were sectioned with a slow-speed saw into multiple beams. After thermocycling, samples were kept in 50% silver nitrate solution. Samples were analyzed with SEM in back-scattered mode. According to the micro-shear bond tests, higher bond strength values were observed in etch-and-rinse system. Bond strength values in self-adhesive and etch-and-rinse groups were significantly higher than self-etch groups in dentin surface and dentin surface treatment with NaOCl. Back-scattered scanning electron microscope results showed that, different degradation mechanism was observed. The present study indicates that, due to the acid etching in dentin, collagen biodegradation was observed within the hybrid layer. On the enamel surfaces, resin degradation was related with resin monomers in adhesive systems.


Assuntos
Colagem Dentária , Adesivos Dentinários , Resinas Compostas , Dentina , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Fatores de Iniciação de Peptídeos , Cimentos de Resina , Estresse Mecânico , Propriedades de Superfície
3.
J Prosthodont ; 28(3): 315-320, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30667169

RESUMO

PURPOSE: To compare the marginal and internal fit of cobalt-chromium (Co-Cr) alloy copings fabricated by with lost wax technique (LW), computer-aided design and computer-aided manufacturing (CAD/CAM), and direct metal laser sintering (DMLS). MATERIALS AND METHODS: Thirty-six tissue level, straight titanium abutments were screwed onto implant replicas. All specimens were embedded in acrylic resin and randomly divided into 3 subgroups according to the fabrication of metal coping: LW, CAD/CAM, and DMLS. In total, 36 (n = 12/group) Co-Cr implant-supported metal copings were prepared. Marginal, intermarginal, axial, and occlusal fits of each coping were measured using the silicone replica technique. The data were evaluated statistically using one-way ANOVA and Bonferioni post-hoc test (α = 0.05). RESULTS: The CAD/CAM group showed significantly lower marginal fit than the LW group and DMLS groups (p < 0.001). The marginal fit of the LW group was not significantly different from the DMLS group (p = 0.721). No significant difference found among the fabrication methods in terms of intermarginal fit (p = 0.913). The CAD/CAM group showed lower axial fit than the LW group (p = 0.026), but there was no statistical difference between the DMLS group and the LW (p = 0.999) and CAD/CAM groups (p = 0.247). No significant differences found among the fabrication methods in terms of occlusal fit (p = 0.158). CONCLUSIONS: The LW and DMLS groups showed better marginal fit compared to the CAD/CAM group; however, the CAD/CAM group was better than the LW group in terms of axial fit. All fabrication methods demonstrated similar intermarginal and occlusal fit.


Assuntos
Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Adaptação Psicológica , Ligas de Cromo , Desenho Assistido por Computador , Coroas
4.
J Prosthodont ; 25(7): 563-569, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26502082

RESUMO

PURPOSE: To investigate the effect of resin cement color on the post-cementation shade of thin laminate veneers milled from multilayered glass ceramic blocks for each layer. MATERIALS AND METHODS: Thin slices (N = 180) with two thicknesses (A: 8 × 8×0.55 mm and B: 8×8×0.8 mm; n = 90/group) were obtained from multilayered glass ceramic blocks using a diamond saw. Resin die specimens were prepared (8 × 8 × 4 mm) (n = 180) and divided into two resin cement colors (D: -3. L: +3) and one control group (C: translucent). Each slice was luted to the composite specimens using a dual-curing resin cement under a constant load of 250 g and light-polymerized for 120 seconds. Specimens were placed on a white background and CIELab values for each layer of the blank slices (incisal [In], body [Bo], and cervical [Ce]) were recorded using a dental contact spectrophotometer. The values were calculated as ΔE, and the data were statistically analyzed (one-way ANOVA, Shapiro-Wilk). RESULTS: Mean ΔE values for A and B were significant (p < 0.05) for In (A: 6.2 ± 1.1; B: 6.6 ± 1.2), Bo (A: 5.1 ± 2.6; B: 3.9 ± 1), and Ce (A: 5.3 ± 2.7; B: 3.8 ± 1.2). Mean ΔE values for In for D and L for A and B groups were significantly higher (6.3 ± 1.2; 6.6 ± 1.2) than Bo and Ce for D (4.4 ± 2.4; 4.6 ± 2.6) and L (4.6 ± 1.4; 4.5 ± 1.7) groups (p < 0.05), respectively. Mean differences between Bo and Ce for A and B groups were insignificant (p ≥ 0.05), while for In the differences were significant. Mean differences between Bo and Ce for A (5.1 ± 2.6; 5.3 ± 2.7) and for B (3.9 ± 1; 3.5 ± 1.2) groups were insignificant (p ≥ 0.05), while for In the differences were significant (6.2 ± 1.1 for A and 6.6 ± 1.2 for B). CONCLUSION: The color changes for body and cervical regions of multilayered ceramic veneers were not affected by resin color or ceramic thickness, but the incisal area was affected. The translucency of each layer in ceramic veneer fabricated with multilayered blanks should be considered for clinical situations.


Assuntos
Facetas Dentárias , Cimentos de Resina , Cimentação , Cor , Desenho Assistido por Computador , Porcelana Dentária , Humanos , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA