1.
Ideggyogy Sz ; 69(3-4): 133-8, 2016 Mar 30.
Artigo em Húngaro | MEDLINE | ID: mdl-27188006

RESUMO

Experiences acquired in our department with endoscope assisted microsurgical transsphenoidal pituitary surgery encouraged us to expanded the endoscopic approach to skull base lesions. The endoscopic endonasal transsphenoidal approach proved to be less traumatic to the traditional microsurgical approaches, yet very effective. The endoscopic transsphenoidal technique was applied in a patient havin anterior skull base tumor. The patient was a 49-year-old woman with several months history of left visual defect. The magnetic resonance (MR) scans of the skull revealed a midline anterior fossa space-occupying lesion measuring 21 x 16 x 22 mm located on planum sphenoidale, tuberculum sellae and intrasellar. The tumor compressed both optic nerves and optic chiasm. Total resection of the tumor was achieved by use of endoscopic transnasal, transsphenoidal technique. This is the first reported case of an anterior fossa meningeoma being treated by an endoscopic transsphenoidal technique in Hungary.


Assuntos
Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Neuroendoscopia/métodos , Seio Esfenoidal , Feminino , Humanos , Hungria , Pessoa de Meia-Idade , Neuronavegação/instrumentação , Nariz , Sela Túrcica , Seio Esfenoidal/cirurgia , Resultado do Tratamento
2.
J Crit Care Med (Targu Mures) ; 2(1): 30-37, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29967834

RESUMO

Mucosal capnometry involves the monitoring of partial pressure of carbon dioxide (PCO2) in mucous membranes. Different techniques have been developed and applied for this purpose, including sublingual or buccal sensors, or special gastrointestinal tonometric devices. The primary use of these procedures is to detect compensated shock in critically ill patients or patients undergoing major surgery. Compensatory mechanisms, in the early phases of shock, lead to the redistribution of blood flow towards the vital organs, within ostensibly typical macro-haemodynamic parameters. Unfortunately, this may result in microcirculatory disturbances, which can play a pivotal role in the development of organ failure. In such circumstances mucosal capnometry monitoring, at different gastrointestinal sites, can provide a sensitive method for the early diagnosis of shock. The special PCO2 monitoring methods assess the severity of ischaemia and help to define the necessary therapeutic interventions and testing of these monitors have justified their prognostic value. Gastrointestinal mucosal capnometry monitoring also helps in determining the severity of ischaemia and is a useful adjunctive in the diagnosis of occlusive splanchnic arterial diseases. The supplementary functional information increases the diagnostic accuracy of radiological techniques, assists in creating individualized treatment plans, and helps in follow-up the results of interventions. The results of a pilot study focusing on the interrelation of splanchnic perfusion and gastrointestinal function are given and discussed concerning recent advances in mucosal capnometry.

3.
Biomed Res Int ; 2015: 160979, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26543848

RESUMO

The aim of this study was to compare stroke volume (SVI) to cardiac index (CI) guided resuscitation in a bleeding-resuscitation experiment. Twenty six pigs were randomized and bled in both groups till baseline SVI (T bsl) dropped by 50% (T 0), followed by resuscitation with crystalloid solution until initial SVI or CI was reached (T 4). Similar amount of blood was shed but animals received significantly less fluid in the CI-group as in the SVI-group: median = 900 (interquartile range: 850-1780) versus 1965 (1584-2165) mL, p = 0.02, respectively. In the SVI-group all variables returned to their baseline values, but in the CI-group animals remained underresuscitated as indicated by SVI, heart rate (HR) and stroke volume variation (SVV), and central venous oxygen saturation (ScvO2) at T 4 as compared to T bsl: SVI = 23.8 ± 5.9 versus 31.4 ± 4.7 mL, HR: 117 ± 35 versus 89 ± 11/min SVV: 17.4 ± 7.6 versus 11.5 ± 5.3%, and ScvO2: 64.1 ± 11.6 versus 79.2 ± 8.1%, p < 0.05, respectively. Our results indicate that CI-based goal-directed resuscitation may result in residual hypovolaemia, as bleeding caused stress induced tachycardia "normalizes" CI, without restoring adequate SVI. As the SVI-guided approach normalized most hemodynamic variables, we recommend using SVI instead of CI as the primary goal of resuscitation during acute bleeding.


Assuntos
Hipovolemia/fisiopatologia , Hipovolemia/terapia , Ressuscitação/métodos , Taquicardia/etiologia , Animais , Gasometria , Soluções Cristaloides , Hidratação/métodos , Hemodinâmica , Hemorragia , Soluções Isotônicas/química , Oxigênio/química , Distribuição Aleatória , Choque/terapia , Volume Sistólico/fisiologia , Suínos
4.
Biomed Res Int ; 2015: 847152, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26504837

RESUMO

Tissue capnometry may be suitable for the indirect evaluation of regional hypoperfusion. We tested the performance of a new sublingual capillary tonometer in experimental hemorrhage. Thirty-six anesthetized, ventilated mini pigs were divided into sham-operated (n = 9) and shock groups (n = 27). Hemorrhagic shock was induced by reducing mean arterial pressure (MAP) to 40 mmHg for 60 min, after which fluid resuscitation started aiming to increase MAP to 75% of the baseline value (60-180 min). Sublingual carbon-dioxide partial pressure was measured by tonometry, using a specially coiled silicone rubber tube. Mucosal red blood cell velocity (RBCV) and capillary perfusion rate (CPR) were assessed by orthogonal polarization spectral (OPS) imaging. In the 60 min shock phase a significant drop in cardiac index was accompanied by reduction in sublingual RBCV and CPR and significant increase in the sublingual mucosal-to-arterial PCO2 gap (PSLCO2 gap), which significantly improved during the 120 min resuscitation phase. There was significant correlation between PSLCO2 gap and sublingual RBCV (r = -0.65, p < 0.0001), CPR (r = -0.64, p < 0.0001), central venous oxygen saturation (r = -0.50, p < 0.0001), and central venous-to-arterial PCO2 difference (r = 0.62, p < 0.0001). This new sublingual tonometer may be an appropriate tool for the indirect evaluation of circulatory changes in shock.


Assuntos
Manometria/instrumentação , Microcirculação/fisiologia , Monitorização Fisiológica/instrumentação , Choque Hemorrágico/fisiopatologia , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Manometria/métodos , Monitorização Fisiológica/métodos , Soalho Bucal/irrigação sanguínea , Soalho Bucal/fisiologia , Suínos
5.
J Crit Care ; 25(3): 541.e9-15, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20149588

RESUMO

PURPOSE: This study provides practical experiences with a new, simple, balloon-free gastric tonometric probe (probe) and reports the results of simultaneous in vitro and in vivo measurements with a conventional, ballooned gastric air tonometer (catheter) and the new device. MATERIALS AND METHODS: Ten healthy volunteers and 50 anesthetized surgical patients with different American Society of Anesthesiologists (ASA) scores, scheduled for neurologic, orthopedic, trauma, and cardiac operations, were enrolled in the study. The values of 60 in vitro and, in 12 surgical patients, 101 in vivo paired Pco(2) measurements--performed simultaneously with the new tonometric probe and the catheter that was connected to a Tonocap monitor--were compared. The tolerability of the measurement with the new probe was examined, and the results of gastric tonometry and, in surgical cases, the gastric tonometric, end-expiratory, and arterial Pco(2) values were registered. The results were evaluated by analysis of variance test. The data of the in vivo paired measurements were evaluated by Bland-Altman analysis. RESULTS: The use of the probe proved to be well tolerated and easily applicable in the studied cases. The results of 20 measurements obtained in healthy volunteers and those of 520 measurements in the surgical cases correspond to the data obtained with the classical methods published in the medical literature. During in vitro paired measurements, there was a good agreement between the data obtained with the 2 methods; however, in the in vivo studies, the results of measurements performed with the probe were mostly higher. CONCLUSIONS: The differences between the results obtained with the 2 methods might have been caused by the quicker equilibration property of the probe and by the fundamental differences between the 2 methods. The new probe seems to be applicable for routine human measurements.


Assuntos
Manometria/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Dióxido de Carbono/análise , Feminino , Mucosa Gástrica/metabolismo , Humanos , Masculino , Manometria/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS