Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 10(1): 1974, 2020 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-32029797

RESUMO

The finding that drugs and metabolites can be detected from fingerprints is of potential relevance to forensic science and as well as toxicology and clinical testing. However, discriminating between dermal contact and ingestion of drugs has never been verified experimentally. The inability to interpret the result of finding a drug or metabolite in a fingerprint has prevented widespread adoption of fingerprints in drug testing and limits the probative value of detecting drugs in fingermarks. A commonly held belief is that the detection of metabolites of drugs of abuse in fingerprints can be used to confirm a drug has been ingested. However, we show here that cocaine and its primary metabolite, benzoylecgonine, can be detected in fingerprints of non-drug users after contact with cocaine. Additionally, cocaine was found to persist above environmental levels for up to 48 hours after contact. Therefore the detection of cocaine and benzoylecgonine (BZE) in fingermarks can be forensically significant, but do not demonstrate that a person has ingested the substance. In contrast, the data here shows that a drug test from a fingerprint (where hands can be washed prior to donating a sample) CAN distinguish between contact and ingestion of cocaine. If hands were washed prior to giving a fingerprint, BZE was detected only after the administration of cocaine. Therefore BZE can be used to distinguish cocaine contact from cocaine ingestion, provided donors wash their hands prior to sampling. A test based on the detection of BZE in at least one of two donated fingerprint samples has accuracy 95%, sensitivity 90% and specificity of 100% (n = 86).


Assuntos
Cocaína/análogos & derivados , Cocaína/metabolismo , Toxicologia Forense/métodos , Pele/química , Detecção do Abuso de Substâncias/métodos , Cocaína/isolamento & purificação , Transtornos Relacionados ao Uso de Cocaína/diagnóstico , Dermatoglifia , Desinfecção das Mãos , Humanos , Irlanda , Espectrometria de Massas , Sensibilidade e Especificidade , Pele/metabolismo , Fatores de Tempo
2.
Nanotechnology ; 27(28): 285103, 2016 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-27255758

RESUMO

There are many possible biomedical applications for titania nanoparticles (NPs) doped with rare earth elements (REEs), from dose enhancement and diagnostic imaging in radiotherapy, to biosensing. However, there are concerns that the NPs could disintegrate in the body thus releasing toxic REE ions to undesired locations. As a first step, we investigate how accurately the Ti/REE ratio from the NPs can be measured inside human cells. A quantitative analysis of whole, unsectioned, individual human cells was performed using proton microprobe elemental microscopy. This method is unique in being able to quantitatively analyse all the elements in an unsectioned individual cell with micron resolution, while also scanning large fields of view. We compared the Ti/REE signal inside cells to NPs that were outside the cells, non-specifically absorbed onto the polypropylene substrate. We show that the REE signal in individual cells co-localises with the titanium signal, indicating that the NPs have remained intact. Within the uncertainty of the measurement, there is no difference between the Ti/REE ratio inside and outside the cells. Interestingly, we also show that there is considerable variation in the uptake of the NPs from cell-to-cell, by a factor of more than 10. We conclude that the NPs enter the cells and remain intact. The large heterogeneity in NP concentrations from cell-to-cell should be considered if they are to be used therapeutically.


Assuntos
Nanopartículas Metálicas , Humanos , Metais Terras Raras , Titânio
3.
Radiat Environ Biophys ; 52(4): 513-21, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23963461

RESUMO

A "broadbeam" facility is demonstrated for the vertical microbeam at Surrey's Ion Beam Centre, validating the new technique used by Barazzuol et al. (Radiat Res 177:651-662, 2012). Here, droplets with a diameter of about 4 mm of 15,000 mammalian cells in suspension were pipetted onto defined locations on a 42-mm-diameter cell dish with each droplet individually irradiated in "broadbeam" mode with 2 MeV protons and 4 MeV alpha particles and assayed for clonogenicity. This method enables multiple experimental data points to be rapidly collected from the same cell dish. Initially, the Surrey vertical beamline was designed for the targeted irradiation of single cells with single counted ions. Here, the benefits of both targeted single-cell and broadbeam irradiations being available at the same facility are discussed: in particular, high-throughput cell irradiation experiments can be conducted on the same system as time-intensive focused-beam experiments with the added benefits of fluorescent microscopy, cell recognition and time-lapse capabilities. The limitations of the system based on a 2 MV tandem accelerator are also discussed, including the uncertainties associated with particle Poisson counting statistics, spread of linear energy transfer in the nucleus and a timed dose delivery. These uncertainties are calculated with Monte Carlo methods. An analysis of how this uncertainty affects relative biological effect measurements is made and discussed.


Assuntos
Radiobiologia/métodos , Animais , Linhagem Celular , Cricetinae , Cricetulus , Relação Dose-Resposta à Radiação , Transferência Linear de Energia , Método de Monte Carlo , Radiobiologia/instrumentação
4.
Rev Sci Instrum ; 78(8): 085101, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17764349

RESUMO

A simple design for a cesium sputter ion source compatible with vacuum and ion-optical systems as well as with electronics of the commercially available Cameca IMS-4f instrument is reported. This ion source has been tested with the cluster primary ions of Si(n)(-) and Cu(n)(-). Our experiments with surface characterization and depth profiling conducted to date demonstrate improvements of the analytical capabilities of the secondary ion mass spectrometry instrument due to the nonadditive enhancement of secondary ion emission and shorter ion ranges of polyatomic projectiles compared to atomic ones with the same impact energy.


Assuntos
Césio , Desenho Assistido por Computador , Íons Pesados , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...