Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Nanotechnol ; 19(4): 514-523, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38212522

RESUMO

One of the critical factors determining the performance of neural interfaces is the electrode material used to establish electrical communication with the neural tissue, which needs to meet strict electrical, electrochemical, mechanical, biological and microfabrication compatibility requirements. This work presents a nanoporous graphene-based thin-film technology and its engineering to form flexible neural interfaces. The developed technology allows the fabrication of small microelectrodes (25 µm diameter) while achieving low impedance (∼25 kΩ) and high charge injection (3-5 mC cm-2). In vivo brain recording performance assessed in rodents reveals high-fidelity recordings (signal-to-noise ratio >10 dB for local field potentials), while stimulation performance assessed with an intrafascicular implant demonstrates low current thresholds (<100 µA) and high selectivity (>0.8) for activating subsets of axons within the rat sciatic nerve innervating tibialis anterior and plantar interosseous muscles. Furthermore, the tissue biocompatibility of the devices was validated by chronic epicortical (12 week) and intraneural (8 week) implantation. This work describes a graphene-based thin-film microelectrode technology and demonstrates its potential for high-precision and high-resolution neural interfacing.


Assuntos
Grafite , Nanoporos , Ratos , Animais , Microeletrodos , Próteses e Implantes , Estimulação Elétrica
2.
J Neurosci Methods ; 366: 109427, 2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-34852254

RESUMO

BACKGROUND: Investigating brain dynamics underlying vocal production in animals is a powerful way to inform on the neural bases of human speech. In particular, brain networks underlying vocal production in non-human primates show striking similarities with the human speech production network. However, despite increasing findings also in birds and more recently in rodents, the extent to which the primate vocal cortical network model generalizes to other non-primate mammals remains unclear. Especially, no domestic species has yet been proposed to investigate vocal brain activity using electrophysiological approaches. NEW METHOD: In the present study, we introduce a novel experimental paradigm to identify the cortical dynamics underlying vocal production in behaving minipigs. A key problem to chronically implant cortical probes in pigs is the presence and growth of frontal sinuses extending caudally to the parietal bone and preventing safe access to neural structures with conventional craniotomy in adult animals. RESULTS: Here we first show that implantations of soft ECoG grids can be done safely using conventional craniotomy in minipigs younger than 5 months, a period when sinuses are not yet well developed. Using wireless recordings in behaving animals, we further show activation of the motor and premotor cortex around the onset of vocal production of grunts, the most common vocalization of pigs. CONCLUSION: These results suggest that minipigs, which are very loquacious and social animals, can be a good experimental large animal model to study the cortical bases of vocal production.


Assuntos
Córtex Motor , Vocalização Animal , Animais , Encéfalo/fisiologia , Córtex Motor/fisiologia , Suínos , Porco Miniatura , Vocalização Animal/fisiologia , Vigília
3.
Adv Sci (Weinh) ; 8(9): 2003761, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33977054

RESUMO

Intraoperative electrocorticography (ECoG) captures neural information from the surface of the cerebral cortex during surgeries such as resections for intractable epilepsy and tumors. Current clinical ECoG grids come in evenly spaced, millimeter-sized electrodes embedded in silicone rubber. Their mechanical rigidity and fixed electrode spatial resolution are common shortcomings reported by the surgical teams. Here, advances in soft neurotechnology are leveraged to manufacture conformable subdural, thin-film ECoG grids, and evaluate their suitability for translational research. Soft grids with 0.2 to 10 mm electrode pitch and diameter are embedded in 150 µm silicone membranes. The soft grids are compatible with surgical handling and can be folded to safely interface hidden cerebral surface such as the Sylvian fold in human cadaveric models. It is found that the thin-film conductor grids do not generate diagnostic-impeding imaging artefacts (<1 mm) nor adverse local heating within a standard 3T clinical magnetic resonance imaging scanner. Next, the ability of the soft grids to record subdural neural activity in minipigs acutely and two weeks postimplantation is validated. Taken together, these results suggest a promising future alternative to current stiff electrodes and may enable the future adoption of soft ECoG grids in translational research and ultimately in clinical settings.


Assuntos
Mapeamento Encefálico/métodos , Eletrocorticografia/instrumentação , Eletrocorticografia/métodos , Eletrodos Implantados , Imageamento por Ressonância Magnética/métodos , Pesquisa Translacional Biomédica/métodos , Animais , Mapeamento Encefálico/instrumentação , Cadáver , Desenho de Equipamento , Humanos , Modelos Animais , Nanotecnologia/métodos , Suínos , Porco Miniatura , Pesquisa Translacional Biomédica/instrumentação
4.
J Neural Eng ; 17(5): 056028, 2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-33055383

RESUMO

OBJECTIVE: A current challenge of neurotechnologies is to develop speech brain-computer interfaces aiming at restoring communication in people unable to speak. To achieve a proof of concept of such system, neural activity of patients implanted for clinical reasons can be recorded while they speak. Using such simultaneously recorded audio and neural data, decoders can be built to predict speech features using features extracted from brain signals. A typical neural feature is the spectral power of field potentials in the high-gamma frequency band, which happens to overlap the frequency range of speech acoustic signals, especially the fundamental frequency of the voice. Here, we analyzed human electrocorticographic and intracortical recordings during speech production and perception as well as a rat microelectrocorticographic recording during sound perception. We observed that several datasets, recorded with different recording setups, contained spectrotemporal features highly correlated with those of the sound produced by or delivered to the participants, especially within the high-gamma band and above, strongly suggesting a contamination of electrophysiological recordings by the sound signal. This study investigated the presence of acoustic contamination and its possible source. APPROACH: We developed analysis methods and a statistical criterion to objectively assess the presence or absence of contamination-specific correlations, which we used to screen several datasets from five centers worldwide. MAIN RESULTS: Not all but several datasets, recorded in a variety of conditions, showed significant evidence of acoustic contamination. Three out of five centers were concerned by the phenomenon. In a recording showing high contamination, the use of high-gamma band features dramatically facilitated the performance of linear decoding of acoustic speech features, while such improvement was very limited for another recording showing no significant contamination. Further analysis and in vitro replication suggest that the contamination is caused by the mechanical action of the sound waves onto the cables and connectors along the recording chain, transforming sound vibrations into an undesired electrical noise affecting the biopotential measurements. SIGNIFICANCE: Although this study does not per se question the presence of speech-relevant physiological information in the high-gamma range and above (multiunit activity), it alerts on the fact that acoustic contamination of neural signals should be proofed and eliminated before investigating the cortical dynamics of these processes. To this end, we make available a toolbox implementing the proposed statistical approach to quickly assess the extent of contamination in an electrophysiological recording (https://doi.org/10.5281/zenodo.3929296).


Assuntos
Percepção da Fala , Fala , Estimulação Acústica , Acústica , Animais , Encéfalo , Humanos , Ruído , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...