1.
J Electrocardiol ; 40(3): 288-91, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17276450

RESUMO

A comparison was performed between the points measured using the Selvester QRS scoring system in 60 electrocardiograms (ECGs) displayed in both a standard format as well as a 4-fold magnified (quad-plot) format. Fifty criteria (a maximum possibility of 31 points) were evaluated in each ECG. The data indicate that in 50% of the ECGs, an identical number of points were measured. However, there was a single point difference in 31%, 2 points in 15%, and more than 2 points in 4%. The differences were primarily because of points scored on the quad-plot but not on the standard ECG. Thus, a systematic underestimation of infarct size may occur when the Selvester QRS score is measured manually from a standard ECG.


Assuntos
Algoritmos , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Infarto do Miocárdio/diagnóstico , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Electrocardiol ; 39(2): 162-8, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16580413

RESUMO

Although the Selvester Scoring System for estimating the size of myocardial infarction from the standard 12-lead electrocardiogram (ECG) has potential clinical value, it has found limited application because of the difficulties in making precise and reproducible measurements. The objective of this study was to develop software to automate the Selvester Scoring System, thus allowing wider application of the technique. The study was carried out using a training set consisting of ECG data recorded from 705 individuals with and without previous myocardial infarction. Algorithms for the 50 criteria in the Selvester Scoring System were iteratively improved by comparison of scores obtained by 2 experienced cardiologist investigators with those generated by the program. The final version was evaluated in a test set consisting of 60 ECGs by comparing scores derived by cardiologist investigator with those obtained by the program. The disagreements occurred only in 1.1% of the score comparisons and in 1.6% of the specific measurements. In all cases in which a disagreement occurred, it resulted from very small differences in measurements. These results indicate that the algorithm for automated application of the Selvester Scoring System is adequate for both clinical and research applications.


Assuntos
Eletrocardiografia , Infarto do Miocárdio/patologia , Processamento de Sinais Assistido por Computador , Algoritmos , Automação , Feminino , Humanos , Masculino , Análise de Regressão , Design de Software , Validação de Programas de Computador