Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Echocardiography ; 39(12): 1522-1531, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36376263

RESUMO

BACKGROUND: Reference change value (RCV) is used to assess the significance of the difference between two measurements after accounting for pre-analytic, analytic, and within-subject variability. The objective of the current study was to define the RCV for global longitudinal strain (GLS) using different semi-automated software in standard clinical practice. METHODS: Using a test-retest study design, we quantified the median coefficient of variation (CV) for GLS using AutoStrain and Automated Cardiac Motion Quantification (aCMQ) by Philips. Triplane left-ventricular ejection fraction (LVEF) was measured for comparison. Multivariable regression analysis was performed to determine factors influencing test-retest CV including image quality and the presence of segmental wall motion abnormalities (WMA). RCV was reported using a standard formula assuming two standard deviations for repeated measurements; results were also translated into Bayesian probability. Total measurement variation was described in terms of its three different components: pre-analytic (acquisition), analytic (measuring variation), and within-subject (biological) variation. RESULT: Of the 44 individuals who were screened, 41 had adequate quality for strain quantification. The mean age of the cohort was 56.4 ± 16.8 years, 41% female, LVEF was 55.8 ± 9.8% and the median and interquartile range for LV GLS was -17.2 [-19.3 to -14.8]%. Autostrain was more time efficient (80% less analysis time) and had a lower total median CV than aCMQ (CV = 7.4% vs. 17.6%, p < .001). The total CV was higher in patients with WMA (6.4% vs. 13.2%, p = .035). In non-segmental disease, the CV translates to a RCV of 15% (corresponding to a probability of real change of 80%). Assuming a within-subject variability of 4.0%, the component analysis identified that inter-reader variability accounts for 3.7% of the CV, while acquisition variability accounts for 4.0%. CONCLUSION: Using test-retest analysis and CVs, we find that an RCV of 15% for GLS represents an optimistic estimate in routine clinical practice. Based on our results, a higher RCV of 17%-21% is needed in order to provide a high probability of clinically meaningful change in GLS in all comers. The methodology presented here for determining measurement reproducibility and RCVs is easily translatable into clinical practice for any imaging parameter.


Assuntos
Deformação Longitudinal Global , Função Ventricular Esquerda , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Volume Sistólico , Teorema de Bayes , Reprodutibilidade dos Testes
2.
Echocardiography ; 26(7): 759-65, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19558521

RESUMO

BACKGROUND: Responders to cardiac resynchronization therapy (CRT) have greater left ventricular (LV) dyssynchrony than nonresponders prior to CRT. AIM: We conducted this study to see whether the long term responders have more worsening of LV dyssynchrony and LV function on acute interruption of CRT. MATERIALS AND METHODS: We identified 22 responders and 13 nonresponders who received CRT as per standard criteria for 23.73 +/- 7.9 months (median 24.5 months). We assessed the acute change in LV function, mitral regurgitation (MR) and compared LV dyssynchrony in CRT on and off modes. RESULTS: On turning off CRT, there was no significant worsening of LV dyssynchrony in both responders and nonresponders. The dyssynchrony measurements by SPWMD, TDI and 3D echocardiography did not correlate significantly. LVESV increased (p = 0.02) and MR (p = 0.01) worsened in CRT-off mode in responders only without significant change in LVEF or LV dimensions. DISCUSSION AND CONCLUSION: In long-term responders to CRT, there is alteration in the function of remodeled LV with acute interruption of CRT, without significant worsening of LV dyssynchrony. The role of different echocardiographic parameters in the assessment of LV dyssynchrony remains controversial. Even after long-term CRT reversely remodels the LV, the therapy needs to be continued uninterrupted for sustained benefits.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/prevenção & controle , Resultado do Tratamento , Ultrassonografia , Disfunção Ventricular Esquerda/prevenção & controle
3.
Echocardiography ; 25(1): 84-7, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18186784

RESUMO

A novel multiplanar reformatting (MPR) technique in three-dimensional transthoracic echocardiography (3D TTE) was used to precisely localize the prolapsed lateral segment of posterior mitral valve leaflet in a patient symptomatic with mitral valve prolapse (MVP) and moderate mitral regurgitation (MR) before undergoing mitral valve repair surgery. Transesophageal echocardiography was avoided based on the findings of this new technique by 3D TTE. It was noninvasive, quick, reproducible and reliable. Also, it did not need the time-consuming reconstruction of multiple cardiac images. Mitral valve repair surgery was subsequently performed based on the MPR findings and corroborated the findings from the MPR examination.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia , Prolapso da Valva Mitral/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Prolapso da Valva Mitral/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...