Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Zhonghua Yi Xue Za Zhi ; 104(23): 2154-2159, 2024 Jun 18.
Artigo em Chinês | MEDLINE | ID: mdl-38871473

RESUMO

Objective: To compare the effects of bronchial intubation and blocker on the outcomes of thoracoscopic surgery in infants and small children. Methods: A total of 387 children, including 210 males and 177 females, aged (17.5±8.3) months, who underwent elective thoracoscopic surgery under general anesthesia in Children's Hospital Affiliated to Capital Institute of Pediatrics from January 2019 to August 2023 were retrospectively analyzed. The children were divided into bronchial intubation group and bronchial blocker group according to the intraoperative single-lung ventilation mode. After matching the age factor using the propensity score matching with nearest neighbor matching method, 258 cases were finally included in the bronchial intubation group, and 129 cases were included in the bronchial blocker group. The primary outcome was the incidence of postoperative pulmonary complications in two groups. The secondary outcomes included the incidence of intraoperative hypoxemia, postoperative oxygenation index, postoperative extubation time, the length of postoperative hospitalization and the total medical expenses during hospitalization between the two groups. Results: The incidence of postoperative pulmonary complications in the bronchial intubation group and bronchial blocker group was 15.5% (40/258) and 12.4% (16/129), the incidence of intraoperative hypoxemia was 20.2% (52/258) and 16.3% (21/129), the postoperative oxygen indexes were 306 (269, 323) and 311 (274, 336) mmHg (1 mmHg=0.133 kPa), the extubation time was (9.2±4.5) and (8.9±4.2) min, the length of postoperative hospitalization was (5.5±0.6) and (5.5±0.5) days and the total medical expenses were (34±6) and (35±6) thousand yuan, with no statistically significant differences between the two groups (all P>0.05). Conclusion: Both bronchial intubation and blocker can be used for one lung ventilation in thoracoscopic surgery for infants and small children, without affecting the postoperative outcomes.


Assuntos
Intubação Intratraqueal , Ventilação Monopulmonar , Complicações Pós-Operatórias , Toracoscopia , Humanos , Masculino , Feminino , Lactente , Estudos Retrospectivos , Complicações Pós-Operatórias/prevenção & controle , Pré-Escolar , Pontuação de Propensão , Brônquios/cirurgia , Anestesia Geral
2.
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi ; 41(10): 854-858, 2023 Oct 20.
Artigo em Chinês | MEDLINE | ID: mdl-37935554

RESUMO

Objective: To establish a method for the rapid determination of the three metabolites of xylene, 2-methylmarmaluronic acid, 3-methylmarmaluronic acid and 4-methylmarmaluronic acid, in urine of occupationally exposed workers by ultra-performance liquid chromatography-high resolution mass spectrometry (UPLC-HRMS) . Methods: In July 2022, urine samples were diluted and extracted with pH=6.86 phosphate cache solution, cleaned up by a MAX solid-phase extraction (SPE) column and separated by an Accucore Ph/Hexyl column (100 mm×2.1 mm, 2.6 µm) with a gradient of 5 mmol/L ammonium formate-0.1% formic acid aqueous solution and methanol as mobile phases. The analysis was carried out in electrospray ionization mode and full mass-data dependent secondary mass spectrometry mode, and quantified by external standard method. The characteristics of each index of this method were analyzed. Results: A good linearity was obtained in the concentration range of 1.0-200.0 µg/L for 2-methylmuramic acid, 3-methylmuramic acid and 4-methylmuramic acid with the correlation coefficients of 0.9979-0.9993. The limits of detection of the method were 0.18-0.24 µg/L. While the spiked recoveries at the three concentrations (1.0 µg/L, 100.0 µg/L, and 180.0 µg/L) were in the range of 83.0%-93.7%, with the relative standard deviations of 2.2%-7.9%. Conclusion: The UPLC-HRMS method is simple, rapid, sensitive and accurate, and is suitable for the simultaneous determination of the three metabolites of xylene in the urine of occupationally exposed workers.


Assuntos
Espectrometria de Massas em Tandem , Xilenos , Humanos , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Extração em Fase Sólida
3.
Opt Lett ; 36(5): 698-700, 2011 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-21368953

RESUMO

In this Letter, we demonstrate a nonlinear-mirror (NLM) mode-locked diode-pumped solid-state Nd:YVO4 laser operating at 1342 nm, in which the NLM comprises a periodically poled LiNbO3 crystal and a dichroic mirror. The self-starting threshold for cw mode locking is 1.5 W, which is significantly lower than that of saturable absorber mode locking. An average power of 1.52 W at 1342 nm is obtained under diode pump power of 10 W at 808 nm, with the slope efficiency being up to 16.8%. The pulse width and the repetition rate of the mode-locked laser output are about 9.5 ps and 101 MHz, respectively.

4.
Scand J Immunol ; 69(6): 508-15, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19439011

RESUMO

Pulmonary SP-D is a defence lectin promoting clearance of viral infections. SP-D is recognized to bind the S protein of SARS-CoV and enhance phagocytosis. Moreover, systemic SP-D is widely used as a biomarker of alveolar integrity. We investigated the relation between plasma SP-D, SARS-type pneumonia and the SARS-specific IgG response. Sixteen patients with SARS, 19 patients with community-acquired pneumonia (CAP) (Streptococcus pneumonia) and 16 healthy control subjects were enrolled in the study. Plasma SP-D and anti-SARS-CoV N protein IgG were measured using ELISA. SP-D was significantly elevated in SARS-type pneumonia [median (95% CI), 453 (379-963) ng/ml versus controls 218 (160-362) ng/ml, P < 0.05] like in patients with CAP. SP-D significantly correlated with anti-SARS-CoV N protein IgG (r(2) = 0.5995, P = 0.02). The possible re-emergence of SARS or SARS-like infections suggests a need for minimal traumatic techniques for following the alveolar compartment, e.g. during testing of antivirals. We suggest that monitoring systemic SP-D may be useful in monitoring the alveolar integrity in SARS-type pneumonia. The significant correlation between plasma SP-D and anti-SARS-CoV-specific antibodies support the role for SP-D in interlinking innate and adaptive immune pathways.


Assuntos
Anticorpos Antivirais/sangue , Imunoglobulina G/sangue , Proteínas do Nucleocapsídeo/imunologia , Proteína D Associada a Surfactante Pulmonar/sangue , Síndrome Respiratória Aguda Grave/imunologia , Adolescente , Adulto , Idoso , Biomarcadores/sangue , Criança , Pré-Escolar , Proteínas do Nucleocapsídeo de Coronavírus , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Proteínas Recombinantes/imunologia , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Coronavírus Relacionado à Síndrome Respiratória Aguda Grave/imunologia
5.
Opt Express ; 16(23): 18616-23, 2008 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-19581947

RESUMO

We have achieved broadband parametric generation by using a quasi-periodically poled LiTaO(3) crystal as frequency converter. Tuning wavelength rang from 0.609 microm to 5.208 microm, which covered three quasi-phase-matching processes, was obtained by means of changing the pump wavelength from 0.530 microm to 1.184 microm. The experiment results are in good agreement with theory. The maximum conversion efficiency is 62% with a 10 Hz-5 ns pump source, at the average pump power of 0.5 mW. Our results exhibit a possible application of quasi-periodic superlattice in laser technology.


Assuntos
Lítio/química , Dispositivos Ópticos , Óxidos/química , Tantálio/química , Transdutores , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...