Int J Radiat Oncol Biol Phys ; 119(3): 946-956, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38300188

RESUMO

PURPOSE: A first of its kind experimental verification of dose-averaged linear energy transfer (LETd) optimized treatment plans for proton therapy has been carried out using a silicon-on-insulator microdosimeter at the Massachusetts General Hospital (MGH), Boston, USA. METHODS AND MATERIALS: Three clinical treatment plans of a typical ependymoma structure set were designed using the standard clinical approach, the proposed protocol approach, and a one-field approach. The plans were then reoptimized to reduce the LETd-weighted dose in the brain stem. All six plans were delivered in a solid water phantom and the experimental yD‾ measured. RESULTS: After LETd optimization, a reduction in yD‾ was found within the brain stem by an average of 12%, 19%, and 4% for the clinical, protocol, and one-field plans, respectively, while maintaining adequate coverage of the tumor structure. The experimental LETd-weighted doses were in agreement with the treatment planning system calculations and Monte Carlo simulations and reinforced the improvement of the optimization. CONCLUSIONS: This work demonstrates the first experimental verification of the clinical implementation of LETd optimization for patient treatment with proton therapy.


Assuntos
Neoplasias Encefálicas , Ependimoma , Transferência Linear de Energia , Método de Monte Carlo , Imagens de Fantasmas , Terapia com Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Terapia com Prótons/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/diagnóstico por imagem , Ependimoma/radioterapia , Ependimoma/diagnóstico por imagem , Radiometria/métodos , Radiometria/instrumentação , Tronco Encefálico/diagnóstico por imagem , Silício , Órgãos em Risco/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...