Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Soc Mass Spectrom ; 21(4): 635-45, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20097575

RESUMO

Nuclear receptors, such as the retinoic acid receptor (RAR) or the 9-cis retinoic acid receptor (RXR), interact not only with their ligands but also with other types of receptors and with DNA. Here, two complementary mass spectrometry (MS) methods were used to study the interactions between retinoic receptors (RXR/RAR) and DNA: non-denaturing nano-electrospray (nanoESI MS), and high-mass matrix-assisted laser desorption ionization (MALDI MS) combined with chemical cross-linking. The RAR x RXR heterodimer was studied in the presence of a specific DNA sequence (DR5), and a specific RAR x RXR x DNA complex was detected with both MS techniques. RAR by itself showed no significant homodimerization. A complex between RAR and the double stranded DR5 was detected with nanoESI. After cross-linking, high-mass MALDI mass spectra showed that the RAR binds the single stranded DR5, and the RAR dimer binds both single and double stranded DR5. Moreover, the MALDI mass spectrum shows a larger RAR dimer signal in the presence of DNA. These results suggest that a gene-regulatory site on DNA can induce quaternary structural changes in a transcription factor such as RAR.


Assuntos
DNA/química , Nanotecnologia/métodos , Receptores do Ácido Retinoico/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Sítios de Ligação , DNA/análise , Ligação Proteica , Receptores do Ácido Retinoico/análise
2.
Toxicol In Vitro ; 23(4): 704-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19233257

RESUMO

High-mass matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) combined with chemical cross-linking has the ability to monitor the ligand-dependent dimerization of the human estrogen receptor alpha ligand binding domain (hERalpha LBD) in solution. Because only ER ligands enhance the homodimer abundance, we evaluated the ability of this label-free approach for identifying endocrine disrupting compounds (EDCs) in a high-throughput manner. This was achieved by combining an automated liquid handler with an automated MS acquisition procedure, which allowed a five-fold gain in operator time compared to a fully manual approach. To detect ligand binding with enough confidence, the receptor has to be incubated with at least a 10 microM concentration of the test compound. Based on the increase of the measured homodimer intensity, eight compounds with a relative binding affinity (RBA, relative to the natural hormone estradiol) >7% were identified as ER ligands among the 28 chemicals tested. Two other compounds, quercetin and 4-tert-amylphenol, were also identified as ER ligands, although their RBAs have been reported to be only 0.01% and 0.000055%, respectively. This suggests that these two ligands have a higher affinity for hERalpha LBD than reported in the literature. The high-mass MALDI approach thus allows identifying high affinity EDCs in an efficient way.


Assuntos
Disruptores Endócrinos/farmacologia , Receptor alfa de Estrogênio/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Sítios de Ligação , Dimerização , Receptor alfa de Estrogênio/metabolismo , Humanos , Ligantes
3.
Anal Biochem ; 375(1): 35-45, 2008 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-18078803

RESUMO

The interaction between the bovine prion protein (bPrP) and a monoclonal antibody, 1E5, was studied with high-mass matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) and surface plasmon resonance (SPR). In the case of MS a cross-linking stabilization was used prior to the analysis, whereas for SPR the antibody was immobilized and bPrP was injected. We compared the determination of parameters such as the epitope, the kinetics and binding strength, and the capacity of the antigen to bind two different antibodies. The two methods are highly complementary. SPR measurements require a lower amount of sample but are more time-consuming due to all of the necessary side steps (e.g., immobilization, regeneration). High-mass MALDI MS needs a higher overall amount of sample and cannot give direct access to the kinetic constants, but the analysis is faster and easier compared with SPR.


Assuntos
Anticorpos Monoclonais/imunologia , Reações Antígeno-Anticorpo/imunologia , Príons/imunologia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Ressonância de Plasmônio de Superfície/métodos , Sequência de Aminoácidos , Animais , Bovinos , Mapeamento de Epitopos , Cinética , Dados de Sequência Molecular , Príons/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...