Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cureus ; 15(4): e38221, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37252500

RESUMO

Introduction The meniscus plays a vital role in maintaining knee stability. It acts as a shock absorber and knee filler. The incidence of meniscal tears is estimated to be 60 per 100,000 people. Due to lack of awareness among patients, only 10% of the meniscus tears were treated through partial or total meniscectomy. Recently, the concept of meniscus preservation surgery has emerged to preserve early degeneration of the knee joint. In the current retrospective study, safety and functional outcomes of arthroscopic meniscal repair surgery using Surestitch All inside implants (Sironix Arthroscopy Solutions, Healthium Medtech Limited, Bengalaru, India) were assessed. Methods Fifty-two patients who underwent arthroscopic meniscal repair surgery between January 2019 to July 2022 at Epic Hospital in Gujarat, India, were enrolled in the study. Retrospective data including demographics, injury details, surgery details, and post-surgery complications were collected from the medical records of the patients. Then, the patients were followed up telephonically to document safety and functional outcomes using patient-reported instruments such as International Knee Documentation Committee (IKDC) score, Single Assessment Numeric Evaluation (SANE) score, Tegner activity level, and Lysholm knee score. Results The recruited patients had the mean age, height, and weight of 37.56 ± 12.52 years, 167.61 ± 7.28 cm, and 75.87 ± 10.7 kgs, respectively. Seventy-one percent of patients were male and 29% were female. Majority of the patients had the routine of doing mild exercise. During pre-surgery representations, medial meniscal tear was observed in majority of patients. The mean length of the tear was 1.32 ± 0.84 cm. In addition, patients were also diagnosed with anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), medial collateral ligament (MCL) tears, and osteochondral defects. Surgeries for meniscal repair were performed using Surestitch All inside implant. In patient-reported outcomes, the mean IKDC, SANE, and Lysholm scores were 81.72 ± 14.23, 94.02 ± 13.79, and 93.32 ± 14.63, respectively. When the mean Tegner scores of pre-injury and post-surgery periods were compared, this resulted in no significant difference (p>0.05) in the activity levels of the patients. Conclusion Based on our findings, arthroscopic meniscal repair with Surestitch All inside meniscal repair implant provides satisfactory and favorable functional outcomes with no remarkable adverse events.

2.
Cureus ; 15(4): e38121, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37252509

RESUMO

Background Rotator cuff tears (RCTs) are the most common cause of shoulder disability. RCT is characterized by progressive wear and tear of the tendon tissue over time. The incidence of cuff tears ranges from 5% to 39%. With increasing advancements in the surgical sector, an upward trend has been observed in repair surgeries where torn tendons are repaired arthroscopically by inserting surgical implants. With this background, this study aimed to assess the safety, efficacy, and functional outcomes after RCT repair using Ceptre® titanium screw anchor implants. Methodology This retrospective, observational, single-center, clinical study was conducted at Epic Hospital in Gujarat, India. Patients who underwent rotator cuff repair surgery between January 2019 and July 2022 were recruited and followed up in December 2022. Baseline characteristics and surgical and post-surgical details were collected from patient medical reports and post-surgery progress data were documented through telephonic follow-up. The functional outcomes and efficacy of the implant were assessed using the American Shoulder and Elbow Surgeons (ASES) form, Shoulder Pain and Disability Index (SPADI) score, Simple Shoulder Test (SST), and Single Assessment Numeric Evaluation (SANE) score. Results The mean age of the recruited patients was 59.74 ± 8.91 years. Among the recruited patients, 64% were females and 36% were males. About 85% of patients had a right shoulder injury and 15% of patients (n = 6/39) had a left shoulder injury. Further, 64% (n = 25/39) of patients had supraspinatus tears, whereas 36% (n = 14) of patients had both supraspinatus and infraspinatus tears. The mean ASES, SPADI, SST, and SANE scores were observed to be 81.43 ± 14.20, 29.41 ± 12.6, 75.41 ± 12.96, and 94.67 ± 7.50, respectively. No adverse events, re-injuries, or re-surgeries were reported by any of the patients during the study period. Conclusions Our findings suggest that arthroscopic rotator cuff repair using Ceptre Knotted Ultra-High-Molecular-Weight Polyethylene Suture Titanium Screw Anchor resulted in favorable functional outcomes. Thus, it could be a considerable implant for a successful surgery.

3.
Clin Biomech (Bristol, Avon) ; 31: 12-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26598806

RESUMO

BACKGROUND: We studied combined effect of change in humeral neck shaft angle and retroversion on shoulder ROM in reverse total shoulder arthroplasty using 3-dimensional simulations. METHODS: Using a 3D model construct based on the CT scans of 3 males and a 3-dimensional analysis program, a humeral component of reverse total shoulder arthroplasty was implanted in 0°, 10°, 20°, 30°,40° retroversion and 135°, 145°, and 155° neck shaft angle. Total horizontal range of motion (sum of horizontal adduction and abduction) at 30° and 60° scaption, adduction in the scapular plane and IR behind the back were measured for various combinations of neck shaft angle and retroversion. FINDINGS: Change in retroversion didn't show any effect on total horizontal range of motion. Total horizontal range of motion at both 30° and 60° scaption, showed maximum values at 135° neck shaft angle and minimum values at 155° neck shaft angle. With any combination of retroversion angles, adduction deficit was maximum at 155° neck shaft angle and no adduction deficit at 135° neck shaft angle. Every 10° decrease in neck shaft angle resulted in an average 10.4° increase in adduction. For every 10° increase in retroversion, there was loss of internal rotation behind the back up to at least one vertebral level. INTERPRETATION: 135° neck shaft angle resulted in maximum total horizontal range of motion both at 30° and 60° scaption regardless of retroversion angles. 135° neck shaft angle also reduced the chances of scapular impingement. Decrease in retroversion angle resulted in more amount of internal rotation behind the back.


Assuntos
Artroplastia de Substituição/métodos , Úmero/cirurgia , Amplitude de Movimento Articular/fisiologia , Escápula/cirurgia , Articulação do Ombro/cirurgia , Adulto , Fenômenos Biomecânicos , Humanos , Úmero/fisiopatologia , Imageamento Tridimensional , Masculino , Escápula/fisiopatologia , Síndrome de Colisão do Ombro/prevenção & controle , Articulação do Ombro/fisiopatologia , Tomografia Computadorizada por Raios X , Adulto Jovem
4.
J Arthroplasty ; 30(8): 1476-81, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25824025

RESUMO

UNLABELLED: Total knee arthroplasty (TKA) can be associated with severe pain in early postoperative period. Adductor canal block may provide optimal analgesia following TKA. However, ideal regimen for administration whether continuous or single shot is yet undefined. We prospectively randomized 90 patients in continuous and single shot adductor canal blockade groups. Postoperative VAS (visual analog scale for pain) score was significantly better at all times in continuous than single shot technique (P<0.001). However, ambulation ability (Timed Up & Go, 10m walk, 30s chair) and early functional recovery (active SLR, ambulation with walker, staircase competency, ambulation distance and maximal flexion at discharge) showed no statistical significant difference. Continuous adductor canal blockade was superior to single shot block in terms of pain control but was similar for early functional recovery. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Amidas/administração & dosagem , Anestésicos Locais/administração & dosagem , Artroplastia do Joelho/reabilitação , Bloqueio Nervoso/métodos , Dor Pós-Operatória/tratamento farmacológico , Idoso , Deambulação Precoce , Feminino , Marcha , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Recuperação de Função Fisiológica , Ropivacaina , Resultado do Tratamento , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...