Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Abdom Radiol (NY) ; 45(1): 203-210, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31482380

RESUMO

PURPOSE: To explore the utility of two different fat quantification methods in the liver and pancreas and to test the accuracy of multi-echo Dixon as a single sequence in detecting early stage of fat deposition. METHODS: 58 healthy potential liver donors underwent abdominal 3T MRI, prospectively. Single-voxel MR Spectroscopy (MRS), dual-echo Dixon, and multi-echo Dixon were performed. Two independent readers obtained proton density fat fraction (PDFF) of the liver and pancreas by placing ROIs on the 2 Dixon sequences. Correlation between the two PDFF measurements was assessed in the liver and pancreas. Values in the liver were also compared to those obtained by MRS. RESULTS: PDFF in the liver was 6.3 ± 4.2%, 5.5 ± 3.9%, and 5.1 ± 4.1% by MRS, dual-echo Dixon, and multi-echo Dixon, respectively. Dual-echo Dixon and multi-echo Dixon showed good correlation in PDFF quantification of the liver (r = 0.82, p < 0.0005). Multi-echo Dixon showed a good correlation (r = 0.72, p = 0.0005) between the fat measured in the liver and in the pancreas. To differentiate between normal (PDFF ≤ 6%) and mild fat deposition (PDFF: 6-33%) in the liver, analysis showed sensitivity, specificity, and accuracy of 74%, 81%, and 80% for dual-echo Dixon and 85%, 96%, and 89% for multi-echo Dixon, respectively. Mean PDFF in the pancreas was 7.2 ± 2.8% and 6.7 ± 3.3%, by dual-echo and multi-echo Dixon, respectively. Dual-echo Dixon and multi-echo Dixon showed good correlation in PDFF quantification of the pancreas (r = 0.58, p < 0.0005). CONCLUSION: Multi-echo Dixon in liver has high accuracy in distinguishing between subjects with normal liver fat and those with mildly elevated liver fat. Multi-echo Dixon can be used to screen for early fat deposition in the liver and pancreas.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Achados Incidentais , Fígado/diagnóstico por imagem , Doadores Vivos/estatística & dados numéricos , Imageamento por Ressonância Magnética/métodos , Pâncreas/diagnóstico por imagem , Adulto , Estudos de Coortes , Feminino , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...