Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Indian J Urol ; 37(4): 355-356, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34759529

RESUMO

Ileal conduit is usually created for urinary diversion after radical cystectomy. The complications of ileal conduit are mainly metabolic. The management of ileal conduit bleeding is challenging, especially in non-cirrhotic patients. We report a patient with gross haematuria from an ileal conduit where super selective arterial embolization was successfully performed after all conservative measures failed.

2.
Indian J Urol ; 35(4): 301-302, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31619871

RESUMO

Synchronous presentation of genitourinary tract malignancies is common, and more so for carcinoma prostate and carcinoma urinary bladder. Each of the carcinomas is treated as per their stage at presentation. Here, we report a case of metastatic carcinoma prostate with penile implant presenting with bladder lesion managed by transurethral resection of bladder tumor (TURBT) through perineal urethrostomy.

3.
Biomater Sci ; 6(6): 1580-1591, 2018 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-29708242

RESUMO

Glaucoma is a chronic disease, which is currently treated using frequent high dose applications of an eye drop solution; this method is tedious, and most of patients are non-compliant to it. Contact lenses are emerging as a convenient option to sustain the release of ophthalmic drugs. However, the incorporation of a drug/formulation changes the optical and physical properties of contact lenses. Contact lens users have also reported pink eye syndrome; this makes contact lenses unsuitable to be accepted as a medical device. The objective of the present study was to design novel timolol and hyaluronic acid (comfort agent)-loaded semi-circular ring-implanted contact lenses that could uphold the release at therapeutic rates without compromising the critical lens properties. The drug-loaded rings were individually implanted within the periphery of the contact lenses using modified cast-moulding technology. Atomic force microscopy showed an average roughness of 12.38 nm for the implanted lens that was significantly lower as compared to that of the Freshlook contact lenses (116.27 nm). A major amount of timolol was leached (from 46.47 to 58.79%) during the monomer extraction and moist sterilization (autoclave) steps; therefore, the lenses were sterilized by radiation and packaged under dry conditions (dehydrated). The in vitro release data showed sustained release of timolol and hyaluronic acid up to 96 h. The in vivo drug release study on rabbit eyes showed the presence of timolol in tear fluid up to 72 h. The in vivo pharmacodynamics studies showed a reduction in IOP till 144 h with a low drug loading (154 µg) as compared to the case of a single instillation eye drop solution (250 µg). This study has demonstrated the successful application of implantation technology to co-deliver timolol and hyaluronic acid from contact lenses for an extended period of time to treat glaucoma.


Assuntos
Anti-Hipertensivos/administração & dosagem , Lentes de Contato , Sistemas de Liberação de Medicamentos/instrumentação , Glaucoma/tratamento farmacológico , Ácido Hialurônico/administração & dosagem , Timolol/administração & dosagem , Animais , Anti-Hipertensivos/farmacocinética , Liberação Controlada de Fármacos , Desenho de Equipamento , Ácido Hialurônico/farmacocinética , Ácido Hialurônico/uso terapêutico , Coelhos , Timolol/farmacocinética , Timolol/uso terapêutico
4.
Acta Biomater ; 53: 211-221, 2017 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-28131945

RESUMO

Contact lenses are widely used for ophthalmic drug delivery, but incorporation of drug or formulation in the contact lenses affects its optical and physical property. In the present study, we have designed a novel hyaluronic acid (HA)-laden ring implant contact lenses (modified cast moulding method), to circumvent the changes in critical lens property. The objective was to improve the ocular residence time of HA, by providing sustained ocular HA delivery through implant contact lenses for the treatment of dry eye syndrome. Optimization of HA-implant was carried out using 32 factorial design by tailoring the amount of cross linker and thickness of implant, to achieve sustained HA release with constraint on effective ion diffusivity. The in vivo pharmacokinetic study in rabbit tear fluid showed sustained HA release up to 15days, by fabricating implant (80µgHA loading) with 78.4µm thickness (total thickness of lens=100µm) using 0.925% of cross linker, with effective ion diffusivity>1.5×10-6mm2/min. In vivo efficacy study in benzalkonium chloride induced dry eye syndrome rabbits showed faster healing with implant contact lenses in comparison to positive control group. The study demonstrated the promising potential of implantation technology to deliver hyaluronic acid without compromising optical and physical properties of contact lens. STATEMENT OF SIGNIFICANCE: The limitation of contact lenses to be used as therapeutic device for controlled drug delivery is focused in this study. Incorporation of drug or formulation in the biomaterial affects the optical and physical property of contact lenses. The significance of project was to design a novel hyaluronic acid-laden ring implant contact lenses, to by-pass the changes in critical property of biomaterial.


Assuntos
Lentes de Contato Hidrofílicas , Sistemas de Liberação de Medicamentos/métodos , Síndromes do Olho Seco/tratamento farmacológico , Ácido Hialurônico/administração & dosagem , Animais , Compostos de Benzalcônio/toxicidade , Materiais Biocompatíveis , Modelos Animais de Doenças , Implantes de Medicamento , Síndromes do Olho Seco/induzido quimicamente , Síndromes do Olho Seco/metabolismo , Feminino , Humanos , Ácido Hialurônico/farmacocinética , Técnicas In Vitro , Masculino , Teste de Materiais , Coelhos , Lágrimas/efeitos dos fármacos , Lágrimas/metabolismo
5.
J Contemp Dent Pract ; 15(2): 161-4, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-25095836

RESUMO

Whenever a hand or a rotary instrument is used to eliminate tooth tissue, the mineralized matrix shatters rather then being uniformly sheared, producing considerably quantities of cutting debris. Much of the debris made up of very small particles of mineralized collagen matrix over the surface of dentin is known as smear layer. The clinical outcome of dental restorations is dependent upon the surface preparations, smear layer formation and hybrid layer which which provides a stable adhesion. Different surface morphology is produced by use of different burs. The thickness of the smear layer is affected by various factors as type of the bur, use of water spray and speed of rotation. Bonding is enhanced when smear layer is completely removed or modifed. The purpose of this in vitro study is to evaluate the effect of different burs on the topography of the smear layer formation and thickness on dentinal surface.


Assuntos
Dentina/ultraestrutura , Camada de Esfregaço/ultraestrutura , Preparo do Dente/instrumentação , Compostos Inorgânicos de Carbono/química , Colágeno/ultraestrutura , Colagem Dentária , Diamante/química , Desenho de Equipamento , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Rotação , Compostos de Silício/química , Irrigação Terapêutica/métodos , Compostos de Tungstênio/química , Água/química
6.
Clin Pract ; 2(1): e26, 2012 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-24765425

RESUMO

An awareness and understanding of the presence of an additional root and unusual root canal morphology is essential as it determines the successful outcome of endodontic treatment. A thorough knowledge of basic root canal anatomy and its variation is necessary for successful completion of endodontic treatment. This report points to the importance of looking for additional roots and canals with the help of operating microscope. Finding additional roots and canals would enable clinician to successfully treat a case that would otherwise not be successful.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...