Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioinformation ; 20(4): 349-352, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38854772

RESUMO

The differences in the effects of orthodontic treatment on airway and craniocervical posture in patients with OSA (obstructive sleep apnea) having skeletal class II high-angle malocclusion is of interest. Hence, 48 individuals with OSA and skeletal class II high-angle malocclusion were chosen from among all patients in need of orthodontic therapy. Every patients had CBCT (cone beam computed tomography) taken both before and after receiving orthodontic therapy. All parameters were assessed on the lateral cephalogram from CBCT in order to assess the indices of craniocervical posture, hyoid position, skeletal and dental conditions. Parameters of upper airway (position of hyoid) showed statistically significant increase in values after orthodontic treatments. Thus, there was increase in values of dimensions of upper airway, post orthodontic treatment. Hence, orthodontic therapy help improve the upper airway morphology and craniocervical posture in patients of OSA with hyperdivergent skeletal class II malocclusion.

2.
J Pharm Bioallied Sci ; 16(Suppl 1): S314-S316, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595473

RESUMO

Introduction: Numerous manufacturers have improved bracket retention systems as a result of the frequent bond failure that occurs during orthodontic treatment. One of the elements affecting the adhesive's bond strength is the bracket retention mechanism. Objectives: This study's objective was to assess how various bracket base retention characters affected shear bond strength. Materials and Methods: Four distinct base features for brackets were evaluated. The basic design was examined using a scanning electron microscope. On the Universal testing equipment, brackets were glued to human teeth and then released. Results: The findings indicate that the polymer-coated base's overall mean SBS, which had a mean value of 21.64 ± 4.14 MPa, was considerably greater than that of the other brackets (P 0.05). The foil meshpad, photochemically etched base, and laser-structured base had mean SBS values of 15.12 ± 5.75 MPa, 16.86 ± 3.76 MPa, and 19.32 ± 4.23MPa, respectively. Conclusions: Following laser-structured base and photochemically etched base brackets in terms of shear bond strength were polymer-coated base brackets. The shear bond strength was the lowest in the plain foil mesh pads.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...