Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biophotonics ; 17(7): e202300475, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38866730

RESUMO

The study encompasses an investigation of optical, photothermal and biocompatibility properties of a composite consisting of golden cores surrounded by superparamagnetic CoFe2O4 nanoparticles. Accompanied with the experiment, the computational modeling reveals that each adjusted magnetic nanoparticle redshifts the plasmon resonance frequency in gold and nonlinearly increases the extinction cross-section at ~800 nm. The concentration dependent photothermal study demonstrates a temperature increase of 8.2 K and the photothermal conversion efficiency of 51% for the 100 µg/mL aqueous solution of the composite nanoparticles, when subjected to a laser power of 0.5 W at 815 nm. During an in vitro photothermal therapy, a portion of the composite nanoparticles, initially seeded at this concentration, remained associated with the cells after washing. These retained nanoparticles effectively heated the cell culture medium, resulting in a 22% reduction in cell viability after 15 min of the treatment. The composite features a potential in multimodal magneto-plasmonic therapies.


Assuntos
Cobalto , Compostos Férricos , Ouro , Nanocompostos , Terapia Fototérmica , Nanocompostos/química , Cobalto/química , Cobalto/farmacologia , Ouro/química , Ouro/farmacologia , Compostos Férricos/química , Humanos , Sobrevivência Celular/efeitos dos fármacos , Temperatura
2.
Cells ; 11(6)2022 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-35326401

RESUMO

The importance of magnetic micro- and nanoparticles for applications in biomedical technology is widely recognised. Many of these applications, including tissue engineering, cell sorting, biosensors, drug delivery, and lab-on-chip devices, require remote manipulation of magnetic objects. High-gradient magnetic fields generated by micromagnets in the range of 103-105 T/m are sufficient for magnetic forces to overcome other forces caused by viscosity, gravity, and thermal fluctuations. In this paper, various magnetic systems capable of generating magnetic fields with required spatial gradients are analysed. Starting from simple systems of individual magnets and methods of field computation, more advanced magnetic microarrays obtained by lithography patterning of permanent magnets are introduced. More flexible field configurations can be formed with the use of soft magnetic materials magnetised by an external field, which allows control over both temporal and spatial field distributions. As an example, soft magnetic microwires are considered. A very attractive method of field generation is utilising tuneable domain configurations. In this review, we discuss the force requirements and constraints for different areas of application, emphasising the current challenges and how to overcome them.


Assuntos
Magnetismo , Nanopartículas , Separação Celular , Campos Magnéticos , Imãs
3.
Nanomaterials (Basel) ; 11(5)2021 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-34063293

RESUMO

Magnetoimpedance (MI) in Co-based microwires with an amorphous and partially crystalline state was investigated at elevated frequencies (up to several GHz), with particular attention paid to the influence of tensile stress on the MI behavior, which is called stress-MI. Two mechanisms of MI sensitivity related to the DC magnetization re-orientation and AC permeability dispersion were discussed. Remarkable sensitivity of impedance changes with respect to applied tensile stress at GHz frequencies was obtained in partially crystalline wires subjected to current annealing. Increasing the annealing current enhanced the axial easy anisotropy of a magnetoelastic origin, which made it possible to increase the frequency of large stress-MI: for 90mA-annealed wire, the impedance at 2 GHz increased by about 300% when a stress of 450 MPa was applied. Potential applications included sensing elements in stretchable substrates for flexible electronics, wireless sensors, and tunable smart materials. For reliable microwave measurements, an improved SOLT (short-open-load-thru) calibration technique was developed that required specially designed strip cells as wire holders. The method made it possible to precisely measure the impedance characteristics of individual wires, which can be further employed to characterize the microwave scattering at wire inclusions used as composites fillers.

4.
Nanomaterials (Basel) ; 11(2)2021 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-33494339

RESUMO

The tunable magnetic properties of amorphous ferromagnetic glass-coated microwires make them suitable for a wide range of applications. Accurate knowledge of the micromagnetic structure is highly desirable since it affects almost all magnetic properties. To select an appropriate wire-sample for a specific application, a deeper understanding of the magnetization reversal process is required, because it determines the measurable response (such as induced voltage waveform and its spectrum). However, the experimental observation of micromagnetic structure of micro-scale amorphous objects has strict size limitations. In this work we proposed a novel experimental technique for evaluating the microstructural characteristics of glass-coated microwires. The cross-sectional permeability distribution in the sample was obtained from impedance measurements at different frequencies. This distribution enables estimation of the prevailing anisotropy in the local region of the wire cross-section. The results obtained were compared with the findings of magnetostatic measurements and remanent state analysis. The advantages and limitations of the methods were discussed.

5.
Sensors (Basel) ; 20(16)2020 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-32781722

RESUMO

The modern development of nanotechnology requires the discovery of simple approaches that ensure the controlled formation of functional nanostructures with a predetermined morphology. One of the simplest approaches is the self-assembly of nanostructures. The widespread implementation of self-assembly is limited by the complexity of controlled processes in a large volume where, due to the temperature, ion concentration, and other thermodynamics factors, local changes in diffusion-limited processes may occur, leading to unexpected nanostructure growth. The easiest ways to control the diffusion-limited processes are spatial limitation and localized growth of nanostructures in a porous matrix. In this paper, we propose to apply the method of controlled self-assembly of gold nanostructures in a limited pore volume of a silicon oxide matrix with submicron pore sizes. A detailed study of achieved gold nanostructures' morphology, microstructure, and surface composition at different formation stages is carried out to understand the peculiarities of realized nanostructures. Based on the obtained results, a mechanism for the growth of gold nanostructures in a limited volume, which can be used for the controlled formation of nanostructures with a predetermined geometry and composition, has been proposed. The results observed in the present study can be useful for the design of plasmonic-active surfaces for surface-enhanced Raman spectroscopy-based detection of ultra-low concentration of different chemical or biological analytes, where the size of the localized gold nanostructures is comparable with the spot area of the focused laser beam.

6.
Nanoscale ; 12(17): 9769-9775, 2020 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-32324192

RESUMO

We propose a method for achieving THz ultra-broadband coherent absorption using the anti-reflection theory of metamaterials. The metamaterial absorber consists of a periodic array of electric ring resonators with a multilayered structure which form the desired refractive index dispersion and provide continuous anti-reflection over a wide frequency range. The destructive interference mechanism and resonance absorption of the absorber are determined by simulation analysis and numerical simulation. Simulation results show that the absorption bandwidth is almost 8.02 THz (absorption rate >90%) over the entire terahertz band (0.1 THz-10 THz). This design provides an effective and viable method for constructing broadband absorbers for stealth technology and the construction of enhanced transmittance devices.

7.
Sensors (Basel) ; 20(6)2020 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-32168981

RESUMO

The development of magnetic field sensors for biomedical applications primarily focuses on equivalent magnetic noise reduction or overall design improvement in order to make them smaller and cheaper while keeping the required values of a limit of detection. One of the cutting-edge topics today is the use of magnetic field sensors for applications such as magnetocardiography, magnetotomography, magnetomyography, magnetoneurography, or their application in point-of-care devices. This introductory review focuses on modern magnetic field sensors suitable for biomedicine applications from a physical point of view and provides an overview of recent studies in this field. Types of magnetic field sensors include direct current superconducting quantum interference devices, search coil, fluxgate, magnetoelectric, giant magneto-impedance, anisotropic/giant/tunneling magnetoresistance, optically pumped, cavity optomechanical, Hall effect, magnetoelastic, spin wave interferometry, and those based on the behavior of nitrogen-vacancy centers in the atomic lattice of diamond.


Assuntos
Técnicas e Procedimentos Diagnósticos , Magnetometria , Monitorização Fisiológica , Desenho de Equipamento , Humanos , Campos Magnéticos
8.
Materials (Basel) ; 13(4)2020 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-32092960

RESUMO

The magnetoelectric (ME) response in a trilayer structure consisting of magnetostrictive Fe77.5B15Si17.5 amorphous microwires between two piezoelectric PZT (PbZr0.53Ti0.47O3) layers was investigated. Soft magnetic properties of wires make it possible to operate under weak bias magnetic fields below 400 A/m. Enhanced ME voltage coefficients were found when the microwires were excited by ac magnetic field of a frequency of 50-60 kHz, which corresponded to the frequency of electromechanical resonance. The as-prepared microwires were in a glass coat creating a large thermoelastic stress and forming a uniaxial magnetic anisotropy. The effect of glass-coat removal and wire annealing on ME coupling was investigated. The glass coat not only affects the wire magnetic structure but also prevents the interfacial bonding between the electric and magnetic subsystems. However, after its removal, the ME coefficient increased slightly less than 10%. Refining the micromagnetic structure and increasing the magnetostriction by stress release during wire annealing (before or after glass removal) strongly increases the ME response up to 100 mV/(cm×Oe) and reduces the characteristic DC magnetic field down to 240 A/m. Although the achieved ME coefficient is smaller than reported values for multilayered films with layers of PZT and soft magnetic alloys as Metglass, the proposed system is promising considering a small volume proportion of microwires.

9.
Nanomaterials (Basel) ; 10(2)2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32024156

RESUMO

Here, we demonstrate the impact of ferromagnetic layer coating on controlling the magneto-optical response. We found that the transverse magneto-optical Kerr effect (TMOKE) signal and TMOKE hysteresis loops of Ni80Fe20 thin layers coated with a Cr layer show a strong dependence on the thickness of the Cr layer and the incidence angle of the light. The transmission and reflection spectra were measured over a range of incidence angles and with different wavelengths so as to determine the layers' optical parameters and to explain the TMOKE behavior. The generalized magneto-optical and ellipsometry (GMOE) model based on modified Abeles characteristic matrices was used to examine the agreement between the experimental and theoretical results. A comprehensive theoretical and experimental analysis reveals the possibility to create a TMOKE suppression/enhancement coating at specific controllable incidence angles. This has potential for applications in optical microscopy and sensors.

10.
Sensors (Basel) ; 19(23)2019 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-31766419

RESUMO

Amorphous ferromagnetic materials in the form of microwires are of interest for the development of various sensors. This paper analyzes and argues for the use of microwires of two basic compositions of Co71Fe5B11Si10Cr3 and Fe3.9(4.9)Co64.82B10.2Si12Cr9(8)Mo0.08 as stress/strain and temperature sensors, respectively. The following properties make them suitable for innovative applications: miniature dimensions, small coercivity, low anisotropy and magnetostriction, tunable magnetic structure, magnetic anisotropy, and Curie temperature by annealing. For example, these sensors can be used for testing the internal stress/strain condition of polymer composite materials and controlling the temperature of hypothermia treatments. The sensing operation is based on the two fundamental effects: the generation of higher frequency harmonics of the voltage pulse induced during remagnetization in wires demonstrating magnetic bistability, and magnetoimpedance.

11.
Research (Wash D C) ; 2019: 3239879, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31549057

RESUMO

The microwave properties of composites containing Fe-based ferromagnetic microwires and carbon fibres have been investigated as part of a campaign to bring added functionalities into structural composites. A transmission window observed in 1-6 GHz demonstrates double-negative (DNG), i.e., metamaterial characteristics in the composites containing short-cut carbon fibres and a parallel array of microwires; the metamaterial characteristic is due to the ferromagnetic resonance and a plasmonic behaviour, as short carbon fibres are proved to ameliorate DNG properties through enhancing the impedance of the composites. In parallel, magnetically tunable metamaterial features are realised in composites containing continuous carbon fibres and microwires, which can be switched on/off via rotating the electrical excitation direction. Such structural composites integrated with metamaterial features (termed as metacomposites) are potentially useful for active cloaking applications among others.

12.
J Nanosci Nanotechnol ; 12(9): 7491-5, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23035502

RESUMO

We indicate that the Magneto-Impedance sensor using amorphous wires has reached a new stage to view "Super MI sensor technology" based on three main advantageous factors of (i) micro sized head and micro power consumption chip, (ii) ultra-high sensitivity micro magnetic sensor with 1 pico-Tesla resolution at the room temperature without any electromagnetic shielding, and (iii) ultra-quick response magnetic sensor with GHz operation. We summarize systematically the magneto-impedance technology with the basic principle and mechanisms of three advantageous features for constitution of various high performance new sensor devices such as the electronic compass chip for mobile phones and smart phones and portable sensors for the magneto-encephalography, the magneto-spinography, and various bio-cell magnetic measurements. Possibility of new application to MI antenna in magnetic telecommunications is also discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...