Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Environ Radioact ; 208-209: 106047, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31526956

RESUMO

As part of an underground gas migration study, two radioactive noble gases (37Ar and 127Xe) and two stable tracer gases (SF6 and PFDMCH) were injected into a historic nuclear explosion test chimney and allowed to migrate naturally. The purpose of this experiment was to provide a bounding case (natural transport) for the flow of radioactive noble gases following an underground nuclear explosion. To accomplish this, soil gas samples were collected from a series of boreholes and a range of depths from the shallow subsurface (3 m) to deeper levels (~160 m) over a period of eleven months. These samples have provided insights into the development and evolution of the subsurface plume and constrained the relative migration rates of the radioactive and stable gas species in the case when the driving pressure from the cavity is low. Analysis of the samples concluded that the stable tracer SF6 was consistently enriched in the subsurface samples relative to the radiotracer 127Xe, but the ratios of SF6 and 37Ar remained similar throughout the samples.


Assuntos
Gases Nobres/análise , Armas Nucleares , Monitoramento de Radiação , Radioatividade , Explosões , Nevada , Medidas de Segurança
2.
J Environ Radioact ; 178-179: 28-35, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28755564

RESUMO

Pacific Northwest National Laboratory reports on the detection of 39Ar at the location of an underground nuclear explosion on the Nevada Nuclear Security Site. The presence of 39Ar was not anticipated at the outset of the experimental campaign but results from this work demonstrated that it is present, along with 37Ar and 85Kr in the subsurface at the site of an underground nuclear explosion. Our analysis showed that by using state-of-the-art technology optimized for radioargon measurements, it was difficult to distinguish 39Ar from the fission product 85Kr. Proportional counters are currently used for high-sensitivity measurement of 37Ar and 39Ar. Physical and chemical separation processes are used to separate argon from air or soil gas, yielding pure argon with contaminant gases reduced to the parts-per-million level or below. However, even with purification at these levels, the beta decay signature of 85Kr can be mistaken for that of 39Ar, and the presence of either isotope increases the measurement background level for the measurement of 37Ar. Measured values for the 39Ar measured at the site ranged from 36,000 milli- Becquerel/standard-cubic-meter-of-air (mBq/SCM) for shallow bore holes to 997,000 mBq/SCM from the rubble chimney from the underground nuclear explosion.


Assuntos
Argônio/análise , Armas Nucleares , Monitoramento de Radiação , Poluentes Radioativos/análise , Nevada
3.
Appl Radiat Isot ; 126: 168-170, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28236554

RESUMO

The Ultra-Low Background Liquid Scintillation Counter developed by Pacific Northwest National Laboratory will expand the application of liquid scintillation counting by enabling lower detection limits and smaller sample volumes. By reducing the overall count rate of the background environment approximately 2 orders of magnitude below that of commercially available systems, backgrounds on the order of tens of counts per day over an energy range of ~3-3600keV can be realized. Initial test results of the ULB LSC show promising results for ultra-low background detection with liquid scintillation counting.

4.
Appl Radiat Isot ; 126: 243-248, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28236555

RESUMO

This paper describes the generation of 39Ar, via reactor irradiation of potassium carbonate, followed by quantitative analysis (length-compensated proportional counting) to yield two calibration standards that are respectively 50 and 3 times atmospheric background levels. Measurements were performed in Pacific Northwest National Laboratory's shallow underground counting laboratory studying the effect of gas density on beta-transport; these results are compared with simulation. The total expanded uncertainty of the specific activity for the ~50× 39Ar in P10 standard is 3.6% (k=2).

5.
J Environ Radioact ; 155-156: 122-129, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26990077

RESUMO

Simultaneous measurement of tritium and (14)C would provide an added tool for tracing organic compounds through environmental systems and is possible via beta energy spectroscopy of sample-derived methane in internal-source gas proportional counters. Since the mid-1960's atmospheric tritium and (14)C have fallen dramatically as the isotopic injections from aboveground nuclear testing have been diluted into the ocean and biosphere. In this work, the feasibility of simultaneous tritium and (14)C measurements via proportional counters is revisited in light of significant changes in both the atmospheric and biosphere isotopics and the development of new ultra-low-background gas proportional counting capabilities for small samples (roughly 50 cc methane). A Geant4 Monte Carlo model of a Pacific Northwest National Laboratory (PNNL) proportional counter response to tritium and (14)C is used to analyze small samples of two different methane sources to illustrate the range of applicability of contemporary simultaneous measurements and their limitations. Because the two methane sources examined were not sample size limited, we could compare the small-sample measurements performed at PNNL with analysis of larger samples performed at a commercial laboratory. These first results show that the dual-isotope simultaneous measurement is well matched for methane samples that are atmospheric or have an elevated source of tritium (i.e. landfill gas). However, for samples with low/modern tritium isotopics (rainwater), commercial separation and counting is a better fit.


Assuntos
Radioisótopos de Carbono/análise , Metano/análise , Monitoramento de Radiação/métodos , Trítio/análise , Gases/análise , Modelos Teóricos , Instalações de Eliminação de Resíduos , Purificação da Água
6.
Appl Radiat Isot ; 109: 430-434, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26701655

RESUMO

Argon-37 is an environmental signature of an underground nuclear explosion. Producing and quantifying low-level (37)Ar standards is an important step in the development of sensitive field measurement instruments. This paper describes progress at Pacific Northwest National Laboratory in developing a process to generate and quantify low-level (37)Ar standards, which can be used to calibrate sensitive field systems at activities consistent with soil background levels. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.

7.
Appl Radiat Isot ; 105: 209-218, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26334781

RESUMO

Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of low-concentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., ß and α) emitting isotopes with no (or very weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35m-water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the scintillation counter's shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.

8.
Appl Radiat Isot ; 81: 151-5, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23623763

RESUMO

A new ultra-low-background proportional counter was recently developed with an internal volume of 100 cm(3) and has been characterized at pressures from 1-10 atm with P-10 (90% Ar, 10% methane) gas. This design, along with a counting system providing event digitization and passive and active shielding, has been developed to complement a new shallow underground laboratory (30 m water-equivalent). Backgrounds and low-level reference materials have been measured, and system sensitivity for (37)Ar has been calculated.


Assuntos
Argônio/análise , Gases/análise , Laboratórios , Radioisótopos/análise , Contagem de Cintilação/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos
9.
Rev Sci Instrum ; 83(11): 113503, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23206058

RESUMO

Pacific Northwest National Laboratory recently commissioned a new shallow underground laboratory, located at a depth of approximately 30 meters-water-equivalent. This new addition to the small class of radiation measurement laboratories located at modest underground depths houses the latest generation of custom-made, high-efficiency, low-background gamma-ray spectrometers and gas proportional counters. This paper describes the unique capabilities present in the shallow underground laboratory; these include large-scale ultra-pure materials production and a suite of radiation detection systems. Reported data characterize the degree of background reduction achieved through a combination of underground location, graded shielding, and rejection of cosmic-ray events. We conclude by presenting measurement targets and future opportunities.

10.
Appl Radiat Isot ; 60(6): 863-77, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15110352

RESUMO

Radioactive xenon monitoring is one of the main technologies used for the detection of underground nuclear explosions. Precise and reliable measurements of (131m)Xe, (133g)Xe, (133m)Xe, and (135g)Xe are required as part of the International Monitoring System for compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT). For the first time, simultaneous testing of four highly sensitive and automated fieldable radioxenon measurement systems has been performed and compared to established laboratory techniques. In addition to an intercomparison of radioxenon monitoring equipment of different design, this paper also presents a set of more than 2000 measurements of activity concentrations of radioactive xenon made in the city of Freiburg, Germany in 2000. The intercomparison experiment showed, that the results from the newly developed systems agree with each other and the equipment fulfills the fundamental requirements for their use in the verification regime of the CTBT. For 24-h measurements, concentrations as low as 0.1 mBqm(-3) were measured for atmospheric samples ranging in size from 10 to 80 m(3). The (133)Xe activity concentrations detected in the ambient air ranged from below 1 mBqm(-3) to above 100 mBqm(-3).


Assuntos
Poluentes Radioativos do Ar/análise , Monitoramento de Radiação/métodos , Radioisótopos de Xenônio/análise , Cooperação Internacional , Energia Nuclear , Monitoramento de Radiação/instrumentação , Reprodutibilidade dos Testes
11.
J Environ Radioact ; 59(2): 139-51, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11900202

RESUMO

The use of the xenon isotopes for detection of nuclear explosions is of great interest for monitoring compliance with the comprehensive nuclear-test-ban treaty (CTBT). Recently, the automated radioxenon sampler-analyzer (ARSA) was tested at the Institute for Atmospheric Radioactivity (IAR) in Freiburg, Germany to ascertain its use for the CTBT by comparing its results to laboratory-based analyses, determining its detection sensitivity and analyzing its results in light of historical xenon isotope levels and known reactor operations in the area. Xe-133 was detected nearly every day throughout the test at activity concentrations ranging between approximately 0.1 mBq/m3 to as high as 120 mBq/m3. Xe-133m and 135Xe were also detected occasionally during the test at concentrations of less than 1 to a few mBq/m3.


Assuntos
Monitoramento Ambiental , Fidelidade a Diretrizes , Cooperação Internacional , Guerra Nuclear , Política Pública , Valores de Referência , Sensibilidade e Especificidade , Isótopos de Xenônio/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...