J Prosthet Dent ; 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38184396

RESUMO

STATEMENT OF PROBLEM: Reasons associated with the failure of facial prosthesis are of major concern and may be associated with deterioration of both elastomeric materials and magnetic attachments. However, the extent of deterioration of these components is unclear. PURPOSE: The purpose of this in vitro study was to evaluate selected retrieved facial prostheses and provide information regarding the electrochemical characterization of the recovered magnetic attachments. MATERIAL AND METHODS: Five facial prostheses (RP1, RP2, RP3, RP4, RP5) fabricated at the University of Texas, M.D. Anderson Cancer Center were retrieved following clinical use. The intaglio and external surfaces of the prostheses along with the incorporated magnetic attachments were photographed. The areas with the detected failures on the retrieved prostheses, as well as the recovered magnetic attachments, were evaluated under a reflected light stereomicroscope at ×16 nominal magnification and photographed with a digital camera. Five magnetic attachments recovered from the prostheses (retrieved group RT) were evaluated for degradation of their corrosion resistance after electrochemical testing in artificial sweat solution and were compared with 5 unused magnetic attachments (control group, CT). To identify the elemental composition of the intact magnet surface, 1 specimen from the control group was investigated by X-ray energy dispersive spectroscopy (EDS). Means and standard deviations of the open circuit potential (EOCP), the zero-circuit potential (Ecorr), and Icorr were calculated and statistically analyzed by a t test (α=.05 for all tests). RESULTS: The main reasons of failure were discoloration, degradation and rupture of the silicone elastomer, marginal misfit, and delamination of the polyurethane sheet. Additional findings were tarnish and discoloration of the magnetic attachments accompanied by considerable smear build-up. EDS results verified the Ni plating of tested magnets. Electrochemical testing revealed that retrieved magnets showed significantly lower OCP (P<.001) and Ecorr (P<.001) but similar Icorr (P=0.083) while the pseudopassivity region of unused magnets vanished in the retrieved group, denoting a degradation of electrochemical properties after clinical use. CONCLUSIONS: In vivo aging exerts extended degradation on the elastomer part of facial prostheses as well as deterioration of their surface integrity and electrochemical properties.

2.
Dent Mater ; 38(11): 1721-1727, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36123188

RESUMO

OBJECTIVES: Three-dimensional (3D) printing technology is a promising technique for fabricating custom orthodontic metallic appliances. Aim of this study was to assess the effect of intraoral aging on the mechanical / electrochemical properties of 3D-printed orthodontic metallic appliances. METHODS: Twelve molar orthodontic distalization appliances 3D-printed from cobalt chromium (Co-Cr) alloy were retrieved after intraoral use and twenty blocks fabricated under similar conditions were used as control. The samples' microstructural / elemental composition assessment was assessed with SEM/EDS, while their mechanical properties (modulus of elasticity [EIT], Martens hardness [HM] and the elastic index [ηIT]) were measured by instrumented indentation testing. Finally, the samples' electrochemical features were assessed with a potentiostat-connected cell arrangement in terms of open circuit potential (OCP), corrosion potential (Ez), current density (I300) and breaking potential (Epit). Results were analyzed by t-test / Mann-Whitney test (α = 0.05). RESULTS: The used Co-Cr alloy was found to have a highly homogenous structure with no significant differences between retrieved and new specimens in HM (4037.7 ± 215.6 vs 4090.9 ± 259.8 N/mm2), EIT (120.0 ± 13.2 vs 123.8 ± 12.9 GPa), or nIT (28.4 ± 2.6 vs 28.6 ± 2.9 %) (P > 0.05 in all instances). Metallic surfaces retained the same oxidation tendency and oxide dissolution rate in passive region in both groups (P > 0.05 for OCP, Ez, and I300). However, intraorally-aged specimens had a significantly lower breakdown potential due to degraded protection efficacy of surface oxide (P = 0.003 for Epit). SIGNIFICANCE: The tested 3D-printed Co-Cr orthodontic appliances present clinically-acceptable mechanical properties that remained unaffected by intraoral ageing, which however degraded the protection of surface oxide against pitting corrosion.


Assuntos
Ligas de Cromo , Aparelhos Ortodônticos , Cromo , Cobalto , Corrosão , Teste de Materiais/métodos , Óxidos , Impressão Tridimensional , Propriedades de Superfície
3.
Sensors (Basel) ; 20(18)2020 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-32933037

RESUMO

Flunitrazepam is an extremely potent benzodiazepine sedative which is associated with "drug-facilitated sexual assault" when administered within an alcoholic drink. This work describes a simple electrochemical method for on-site rapid detection of flunitrazepam in untreated spirits (whiskey, vodka and gin) using a single-use screen-printed sensor (featuring graphite working and auxiliary electrodes and an Ag/AgCl reference electrode) in a dry reagent format. Analysis was performed by placing a drop of sample on the sensor, which was previously coated with dry KCl, and recording selected reduction/oxidation peaks of the target compound in a cyclic voltammetry scan. The limit of quantification of flunitrazepam was at the sub-mg L-1 range. The between-sensor % relative standard deviation of the analytically useful reduction peak in a solution containing 11.4 mg L-1 flunitrazepam was 9.8% (n = 5). Quantification was performed using calibration curves constructed from pooled samples spiked with flunitrazepam with relative errors <15%. The main advantages of the methodology are that it involves no sample pretreatment (such as deoxygenation, extraction or reagent(s) addition) and requires only drop-sized volumes of the sample, thus facilitating rapid on-site screening using portable equipment.


Assuntos
Flunitrazepam , Preparações Farmacêuticas , Técnicas Eletroquímicas , Eletrodos , Indicadores e Reagentes , Estupro