Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 97(21): 212001, 2006 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-17155738

RESUMO

The mean square polarizability radii of the proton have been measured for the first time in a virtual-Compton-scattering experiment performed at the MIT-Bates out-of-plane scattering facility. Response functions and polarizabilities obtained from a dispersion analysis of the data at Q2 = 0.057 GeV2/c2 are in agreement with O(p3) heavy baryon chiral perturbation theory. The data support the dominance of mesonic effects in the polarizabilities.

2.
Phys Rev Lett ; 94(2): 022003, 2005 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-15698166

RESUMO

We report new precise H(e,e(')p)pi(0) measurements at the Delta(1232) resonance at Q(2)=0.127 (GeV/c)(2) obtained at the MIT-Bates out-of-plane scattering facility which are particularly sensitive to the transverse electric amplitude (E2) of the gamma(*)N-->Delta transition. The new data have been analyzed together with those of earlier measurements to yield precise quadrupole to dipole amplitude ratios: Re(E(3/2)(1+)/M(3/2)(1+))=(-2.3+/-0.3(stat+syst)+/-0.6(model))% and Re(S(3/2)(1+)/M(3/2)(1+))=(-6.1+/-0.2(stat+syst)+/-0.5(model))% for M(3/2)(1+)=(41.4+/-0.3(stat+syst)+/-0.4(model))(10(-3)/m(pi(+))). The derived amplitudes give credence to the conjecture of deformation in hadrons favoring, at low Q2, the dominance of mesonic effects.

3.
Appl Radiat Isot ; 58(4): 501-8, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12672631

RESUMO

The results of studies conducted with a small field of view tomographic gamma camera based on a Position Sensitive Photomultiplier Tube are reported. The system has been used for the evaluation of radiopharmaceuticals in small animals. Phantom studies have shown a spatial resolution of 2mm in planar and 2-3mm in tomographic imaging. Imaging studies in mice have been carried out both in 2D and 3D. Conventional radiopharmaceuticals have been used and the results have been compared with images from a clinically used system.


Assuntos
Bombesina/farmacocinética , Neoplasias Experimentais/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética , Tecnécio/farmacocinética , Algoritmos , Animais , Câmaras gama , Processamento de Imagem Assistida por Computador/instrumentação , Rim/diagnóstico por imagem , Camundongos , Camundongos Nus , Cintilografia , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador/instrumentação , Tecnécio/química
4.
Comput Med Imaging Graph ; 27(4): 307-13, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12631516

RESUMO

This paper investigates the possibility of developing a SPECT system that combines the high spatial resolution of position sensitive photomultiplier tubes (PSPMTs) with the excellent performance of iterative reconstruction algorithms. A small field of view (FOV) camera based on a PSPMT and a pixelized scintillation crystal made of CsI(Tl) have been used for the acquisition of the projections. With the use of maximum likelihood expectation maximization (ML-EM) and ordered subsets expectation maximization (OSEM) slices of the object are obtained while three-dimensional (3D) reconstruction of the object is carried out using a modified marching cubes (MMC) algorithm. The spatial resolution of tomographic images obtained with the system was 2-3mm. The spatial resolution of a conventional system that uses filtered backprojection (FBP) for slices reconstruction was more than 9 mm.


Assuntos
Algoritmos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Câmaras gama , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
5.
Phys Rev Lett ; 87(17): 172301, 2001 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-11690266

RESUMO

Measurements of the (2)H((-->)e,e(')p)n reaction were performed with the out-of-plane magnetic spectrometers (OOPS) at the MIT-Bates Linear Accelerator. The longitudinal-transverse, f(LT) and f(')(LT), and the transverse-transverse, f(TT), interference responses at a missing momentum of 210 MeV/c were simultaneously extracted in the dip region at Q2 = 0.15 (GeV/c)(2). In comparison to models of deuteron electrodisintegration, the data clearly reveal strong effects of relativity and final-state interactions and the importance of two-body meson-exchange currents and isobar configurations. We demonstrate that such effects can be disentangled by extracting these responses using the novel out-of-plane technique.

6.
Phys Rev Lett ; 86(14): 2963-6, 2001 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-11290083

RESUMO

High-precision 1H(e,e'p)pi(0) measurements at Q2 = 0.126 (GeV/c)2 are reported, which allow the determination of quadrupole amplitudes in the gamma*N-->Delta transition; they simultaneously test the reliability of electroproduction models. The derived quadrupole-to-dipole ( I = 3/2) amplitude ratios, R(SM) = (-6.5+/-0.2(stat+sys)+/-2.5(mod))% and R(EM) = (-2.1+/-0.2(stat+sys)+/-2.0(mod))%, are dominated by model error. Previous R(SM) and R(EM) results should be reconsidered after the model uncertainties associated with the method of their extraction are taken into account.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...