Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Int J Radiat Oncol Biol Phys ; 85(1): 271-7, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22541964

RESUMO

PURPOSE: To report the process and initial experience of remote credentialing of three-dimensional (3D) image guided radiation therapy (IGRT) as part of the quality assurance (QA) of submitted data for Radiation Therapy Oncology Group (RTOG) clinical trials; and to identify major issues resulting from this process and analyze the review results on patient positioning shifts. METHODS AND MATERIALS: Image guided radiation therapy datasets including in-room positioning CT scans and daily shifts applied were submitted through the Image Guided Therapy QA Center from institutions for the IGRT credentialing process, as required by various RTOG trials. A centralized virtual environment is established at the RTOG Core Laboratory, containing analysis tools and database infrastructure for remote review by the Physics Principal Investigators of each protocol. The appropriateness of IGRT technique and volumetric image registration accuracy were evaluated. Registration accuracy was verified by repeat registration with a third-party registration software system. With the accumulated review results, registration differences between those obtained by the Physics Principal Investigators and from the institutions were analyzed for different imaging sites, shift directions, and imaging modalities. RESULTS: The remote review process was successfully carried out for 87 3D cases (out of 137 total cases, including 2-dimensional and 3D) during 2010. Frequent errors in submitted IGRT data and challenges in the review of image registration for some special cases were identified. Workarounds for these issues were developed. The average differences of registration results between reviewers and institutions ranged between 2 mm and 3 mm. Large discrepancies in the superior-inferior direction were found for megavoltage CT cases, owing to low spatial resolution in this direction for most megavoltage CT cases. CONCLUSION: This first experience indicated that remote review for 3D IGRT as part of QA for RTOG clinical trials is feasible and effective. The magnitude of registration discrepancy between institution and reviewer was presented, and the major issues were investigated to further improve this remote evaluation process.


Assuntos
Ensaios Clínicos como Assunto/normas , Credenciamento/normas , Imageamento Tridimensional/normas , Revisão por Pares/métodos , Garantia da Qualidade dos Cuidados de Saúde/normas , Radioterapia (Especialidade)/normas , Radioterapia Guiada por Imagem/normas , Estudos de Viabilidade , Humanos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia Guiada por Imagem/métodos , Reprodutibilidade dos Testes , Software
2.
J Phys Chem A ; 116(15): 3940-5, 2012 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-22397677

RESUMO

Understanding the damage of DNA bases from hydrogen abstraction by free OH radicals is of particular importance to understanding the indirect effect of ionizing radiation. Previous studies address the problem with truncated DNA bases as ab initio quantum simulations required to study such electronic-spin-dependent processes are computationally expensive. Here, for the first time, we employ a multiscale and hybrid quantum mechanical-molecular mechanical simulation to study the interaction of OH radicals with a guanine-deoxyribose-phosphate DNA molecular unit in the presence of water, where all of the water molecules and the deoxyribose-phosphate fragment are treated with the simplistic classical molecular mechanical scheme. Our result illustrates that the presence of water strongly alters the hydrogen-abstraction reaction as the hydrogen bonding of OH radicals with water restricts the relative orientation of the OH radicals with respect to the DNA base (here, guanine). This results in an angular anisotropy in the chemical pathway and a lower efficiency in the hydrogen-abstraction mechanisms than previously anticipated for identical systems in vacuum. The method can easily be extended to single- and double-stranded DNA without any appreciable computational cost as these molecular units can be treated in the classical subsystem, as has been demonstrated here.


Assuntos
Guanina/química , Radical Hidroxila/química , Simulação de Dinâmica Molecular , DNA/química , Soluções
3.
Med Phys ; 38(5): 2335-41, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21776767

RESUMO

PURPOSE: Several linacs with integrated kilovoltage (kV) imaging have been developed for delivery of image guided radiation therapy (IGRT). High geometric accuracy and coincidence of kV imaging systems and megavoltage (MV) beam delivery are essential for successful image guidance. A geometric QA tool has been adapted for routine QA for evaluating and characterizing the geometric accuracy of kV and MV cone-beam imaging systems. The purpose of this work is to demonstrate the application of methodology to routine QA across three IGRT-dedicated linac platforms. METHODS: It has been applied to a Varian Trilogy (Varian Medical Systems, Palo Alto, CA), an Elekta SynergyS (Elekta, Stockholm, Sweden), and a Brainlab Vero (Brainlab AG, Feldkirchen, Germany). Both the Trilogy and SynergyS linacs are equipped with a retractable kV x-ray tube and a flat panel detector. The Vero utilizes a rotating, rigid ring structure integrating a MV x-ray head mounted on orthogonal gimbals, an electronic portal imaging device (EPID), two kV x-ray tubes, and two fixed flat panel detectors. This dual kV imaging system provides orthogonal radiographs, CBCT images, and real-time fluoroscopic monitoring. Two QA phantoms were built to suit different field sizes. Projection images of a QA phantom were acquired using MV and kV imaging systems at a series of gantry angles. Software developed for this study was used to analyze the projection images and calculate nine geometric parameters for each projection. The Trilogy was characterized five times over one year, while the SynergyS was characterized four times and the Vero once. Over 6500 individual projections were acquired and analyzed. Quantitative geometric parameters of both MV and kV imaging systems, as well as the isocenter consistency of the imaging systems, were successfully evaluated. RESULTS: A geometric tool has been successfully implemented for calibration and QA of integrated kV and MV across a variety of radiotherapy platforms. X-ray source angle deviations up to 0.8 degrees, and detector center offsets up to 3 mm, were observed for three linacs, with the exception of the Vero, for which a significant center offset of one kV detector (prior to machine commissioning) was observed. In contrast, the gimbal-based MV source positioning of the Vero demonstrated differences between observed and expected source positions of less than 0.2 mm, both with and without gimbal rotation. CONCLUSIONS: This initial application of this geometric QA tool shows promise as a universal, independent tool for quantitative evaluation of geometric accuracies of both MV and integrated kV imaging systems across a range of platforms. It provides nine geometric parameters of any imaging system at every gantry angle as well as the isocenter coincidence of the MV and kV image systems.


Assuntos
Algoritmos , Imageamento Tridimensional/instrumentação , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radioterapia Conformacional/instrumentação , Terapia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração/instrumentação , Integração de Sistemas
4.
Med Phys ; 37(8): 4078-101, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20879569

RESUMO

Task Group 101 of the AAPM has prepared this report for medical physicists, clinicians, and therapists in order to outline the best practice guidelines for the external-beam radiation therapy technique referred to as stereotactic body radiation therapy (SBRT). The task group report includes a review of the literature to identify reported clinical findings and expected outcomes for this treatment modality. Information is provided for establishing a SBRT program, including protocols, equipment, resources, and QA procedures. Additionally, suggestions for developing consistent documentation for prescribing, reporting, and recording SBRT treatment delivery is provided.


Assuntos
Guias de Prática Clínica como Assunto , Radiocirurgia/normas , Estados Unidos
5.
Radiother Oncol ; 96(1): 48-54, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20430460

RESUMO

PURPOSE: To assess the accuracy of current stereotactic body radiation therapy (SBRT) lung treatment planning methodologies on irregular breathing patterns, we have performed a systematic dosimetric evaluation in phantoms by utilizing maximum intensity projection (MIP) and average (AVG) images generated from four dimensional computed tomography (4DCT). METHODS: A custom built programmable lung phantom was used to simulate tumor motions due to various breathing patterns of patients. 4DCT scans were obtained in helical mode, and reconstructed AVG and MIP datasets were imported into the Pinnacle 8.0 h treatment planning system. SBRT plans were generated and executed, and delivered doses were measured by radiochromic film for analysis. RESULTS: For targets moving regularly or irregularly within a small range (7.0+/-1.8 mm, n=6), we observed good agreement between the measured and computed dose distributions. However, for targets moving irregularly with a larger range (20.8+/-2.6 mm, n=4), the measured isodose lines were found to be shifted relative to the planned distribution, resulting in an under-dosing (over 10%) in a portion of the PTV. We further observed that the discrepancy between planned and measured dose distribution is due to the inaccurate representation of irregular target motion in the MIP images generated from 4DCT. CONCLUSIONS: Caution should be used when planning from 4DCT images in the presence of large and irregular target motion. The inaccuracy inherent in 4DCT MIP and AVG images can be mitigated through the application of methodologies to reduce respiratory motion, such as abdominal compression, and through the use of volumetric image guidance (e.g., cone beam CT-CBCT) to assure precise targeting with minimal shifts.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares/cirurgia , Imagens de Fantasmas , Radiocirurgia/métodos , Relação Dose-Resposta à Radiação , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Modelos Biológicos , Interpretação de Imagem Radiográfica Assistida por Computador , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Técnicas de Imagem de Sincronização Respiratória , Sensibilidade e Especificidade
6.
Med Phys ; 37(12): 6116-24, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21302768

RESUMO

PURPOSE: Target tracking using dynamic multileaf collimator (DMLC) is a promising approach for intrafraction motion management in radiation therapy. The purpose of this work is to develop a DMLC tracking algorithm capable of delivering volumetric-modulated arc therapy (VMAT) to the targets that experience two-dimensional (2D) rigid motion in the beam's eye view. METHODS: The problem of VMAT delivery to moving targets is formulated as a control problem with constraints. The relationships between gantry speed, gantry acceleration, MLC leaf-velocity, dose rate, and target motion are derived. An iterative search algorithm is developed to find numerical solutions for efficient delivery of a specific VMAT plan to the moving target using 2D DMLC tracking. The delivery of five VMAT lung plans is simulated. The planned and delivered fluence maps in the target-reference frame are calculated and compared. RESULTS: The simulation demonstrates that the 2D tracking algorithm is capable of delivering the VMAT plan to a moving target fast and accurately without violating the machine constraints and the integrity of the treatment plan. The average delivery time is only 29 s longer than that of no-tracking delivery, 101 versus 72 s, respectively. The fluence maps are normalized to 200 MU and the average root-mean-square error between the desired and the delivered fluence is 2.1 MU, compared to 14.8 MU for no-tracking and 3.6 MU for one-dimensional tracking. CONCLUSIONS: A locally optimal MLC tracking algorithm for VMAT delivery is proposed, aiming at shortest delivery time while maintaining treatment plan invariant. The inconsequential increase of treatment time due to DMLC tracking is clinically desirable, which makes VMAT with DMLC tracking attractive in treating moving tumors.


Assuntos
Algoritmos , Movimento , Radioterapia Assistida por Computador/métodos , Fracionamento da Dose de Radiação , Humanos , Respiração , Software
7.
IEEE Trans Biomed Circuits Syst ; 4(4): 223-31, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23853368

RESUMO

Intensity-modulated radiation therapy (IMRT) requires precise delivery of the prescribed dose of radiation to the target and surrounding tissue. Irradiation of moving body anatomy is possible only if stable, accurate, and reliable information about the moving body structures are provided in real time. This paper presents a magnetic position tracking system for radiation therapy. The proposed system uses only four transmitting coils and an implantable transponder. The four transmitting coils generate a magnetic field which is sensed and measured by a biaxial magnetoresistive sensor in the transponder in the tumor. The transponder transmits the information back to a computer to determine the position of the transponder allowing it to track the tumor in real time. The transmission of the information from the transponder to the computer can be wired or wireless. Measurements using a biaxial sensor agree well with the field strength calculated from the ideal equations. The translation from the measurement data to the 3-D location and orientation requires a numerical technique because the equations are in nonclosed forms. The algorithm of tracking is implemented using MATLAB. Each calculation of the position along the target trajectory takes 30 ms, which makes the proposed system suitable for real-time tracking of the transponder for radiation assessment and delivery. An error of less than 2 mm is achieved in the demonstration.

8.
Nat Rev Clin Oncol ; 7(1): 44-54, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19997074

RESUMO

Stereotactic body radiation therapy (SBRT) involves the delivery of a small number of ultra-high doses of radiation to a target volume using very advanced technology and has emerged as a novel treatment modality for cancer. The role of SBRT is most important at two cancer stages-in early primary cancer and in oligometastatic disease. This modality has been used in the treatment of early-stage non-small-cell lung cancer, prostate cancer, renal-cell carcinoma, and liver cancer, and in the treatment of oligometastases in the lung, liver, and spine. A large body of evidence on the use of SBRT for the treatment of primary and metastatic tumors in various sites has accumulated over the past 10-15 years, and efficacy and safety have been demonstrated. Several prospective clinical trials of SBRT for various sites have been conducted, and several other trials are currently being planned. The results of these clinical trials will better define the role of SBRT in cancer management. This article will review the radiobiologic, technical, and clinical aspects of SBRT.


Assuntos
Neoplasias/cirurgia , Radiocirurgia , Neoplasias Abdominais/cirurgia , Ensaios Clínicos como Assunto , Fracionamento da Dose de Radiação , Relação Dose-Resposta à Radiação , Humanos , Imobilização/instrumentação , Masculino , Neoplasias da Próstata/cirurgia , Lesões por Radiação/etiologia , Radiocirurgia/efeitos adversos , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional , Neoplasias da Coluna Vertebral/cirurgia , Neoplasias Torácicas/cirurgia
9.
Med Phys ; 36(7): 3013-7, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19673200

RESUMO

We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy (IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it possible to search for global minima in a complex landscape of multiple irradiation strategies delivering a given, predetermined intensity map to a target. The optimal strategy was investigated with respect to minimizing the dose delivered to the OAR. The optimization procedure developed relies on variability of all parameters available for control of radiation delivery in modern linear accelerators, including adaptation of leaf trajectories and simultaneous modification of beam dose rate during irradiation. We showed that the optimization algorithms lead to a significant reduction in the dose delivered to OAR in cases where organs at risk move relative to a treatment target.


Assuntos
Algoritmos , Movimento , Radioterapia de Intensidade Modulada/métodos , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica , Risco , Fatores de Tempo
10.
Expert Rev Anticancer Ther ; 9(5): 621-35, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19445579

RESUMO

The standard treatment for metastatic cancer is systemic therapy. However, in a subset of patients with limited extracranial metastases or oligometastases, local ablative therapy in combination with systemic therapy may improve treatment outcomes. Stereotactic body radiation therapy (SBRT) has emerged as a novel approach for local ablation of extracranial oligometastases. There is a good body of experience in the use of SBRT for the treatment of oligometastases in various sites including the lung, the liver and the spine with promising results. This article provides an overview of the use of SBRT in the management of extracranial oligometastases.


Assuntos
Neoplasias Encefálicas/cirurgia , Neoplasias Hepáticas/cirurgia , Neoplasias Pulmonares/cirurgia , Radiocirurgia , Neoplasias da Coluna Vertebral/cirurgia , Neoplasias Encefálicas/patologia , Humanos , Neoplasias Hepáticas/secundário , Neoplasias Pulmonares/secundário , Neoplasias da Coluna Vertebral/secundário
11.
Int J Radiat Oncol Biol Phys ; 75(3): 677-82, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19251380

RESUMO

PURPOSE: The 50-month results of a prospective Phase II trial of stereotactic body radiation therapy (SBRT) in medically inoperable patients are reported. METHODS AND MATERIALS: A total of 70 medically inoperable patients had clinically staged T1 (34 patients) or T2 (36 patients) (< or =7 cm), N0, M0, biopsy-confirmed non-small-cell lung carcinoma (NSCLC) and received SBRT as per our previously published reports. The SBRT treatment dose of 60-66 Gy was prescribed to the 80% isodose volume in three fractions. RESULTS: Median follow-up was 50.2 months (range, 1.4-64.8 months). Kaplan-Meier local control at 3 years was 88.1%. Regional (nodal) and distant recurrence occurred in 6 (8.6%) and 9 (12.9%) patients, respectively. Median survival (MS) was 32.4 months and 3-year overall survival (OS) was 42.7% (95% confidence interval [95% CI], 31.1-54.3%). Cancer-specific survival at 3 years was 81.7% (95% CI, 70.0-93.4%). For patients with T1 tumors, MS was 38.7 months (95% CI, 25.3-50.2) and for T2 tumors MS was 24.5 months (95% CI, 18.5-37.4) (p = 0.194). Tumor volume (< or =5 cc, 5-10 cc, 10-20 cc, >20 cc) did not significantly impact survival: MS was 36.9 months (95% CI, 18.1-42.9), 34.0 (95% CI, 16.9-57.1), 32.8 (95% CI, 21.3-57.8), and 21.4 months (95% CI, 17.8-41.6), respectively (p = 0.712). There was no significant survival difference between patients with peripheral vs. central tumors (MS 33.2 vs. 24.4 months, p = 0.697). Grade 3 to 5 toxicity occurred in 5 of 48 patients with peripheral lung tumors (10.4%) and in 6 of 22 patients (27.3%) with central tumors (Fisher's exact test, p = 0.088). CONCLUSION: Based on our study results, use of SBRT results in high rates of local control in medically inoperable patients with Stage I NSCLC.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/cirurgia , Neoplasias Pulmonares/cirurgia , Radiocirurgia , Carcinoma Pulmonar de Células não Pequenas/mortalidade , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/secundário , Intervalos de Confiança , Seguimentos , Humanos , Neoplasias Pulmonares/mortalidade , Neoplasias Pulmonares/patologia , Estadiamento de Neoplasias , Estudos Prospectivos , Radiocirurgia/efeitos adversos , Dosagem Radioterapêutica , Análise de Sobrevida , Carga Tumoral
12.
Int J Radiat Oncol Biol Phys ; 73(4): 1235-42, 2009 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-19251095

RESUMO

PURPOSE: Using a retrospective analysis of treatment plans submitted from multiple institutions accruing patients to the Radiation Therapy Oncology Group (RTOG) 0236 non-small-cell stereotactic body radiotherapy protocol, the present study determined the dose prescription and critical structure constraints for future stereotactic body radiotherapy lung protocols that mandate density-corrected dose calculations. METHOD AND MATERIALS: A subset of 20 patients from four institutions participating in the RTOG 0236 protocol and using superposition/convolution algorithms were compared. The RTOG 0236 protocol required a prescription dose of 60 Gy delivered in three fractions to cover 95% of the planning target volume. Additional requirements were specified for target dose heterogeneity and the dose to normal tissue/structures. The protocol required each site to plan the patient's treatment using unit density, and another plan with the same monitor units and applying density corrections was also submitted. These plans were compared to determine the dose differences. Two-sided, paired Student's t tests were used to evaluate these differences. RESULTS: With heterogeneity corrections applied, the planning target volume receiving >/=60 Gy decreased, on average, 10.1% (standard error, 2.7%) from 95% (p = .001). The maximal dose to any point >/=2 cm away from the planning target volume increased from 35.2 Gy (standard error, 1.7) to 38.5 Gy (standard error, 2.2). CONCLUSION: Statistically significant dose differences were found with the heterogeneity corrections. The information provided in the present study is being used to design future heterogeneity-corrected RTOG stereotactic body radiotherapy lung protocols to match the true dose delivered for RTOG 0236.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/cirurgia , Fracionamento da Dose de Radiação , Neoplasias Pulmonares/cirurgia , Radiocirurgia , Algoritmos , Carcinoma Pulmonar de Células não Pequenas/patologia , Humanos , Neoplasias Pulmonares/patologia , Dose Máxima Tolerável , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional/métodos , Estudos Retrospectivos , Carga Tumoral
13.
Int J Radiat Oncol Biol Phys ; 73(2): 618-25, 2009 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-19147026

RESUMO

PURPOSE: For the treatment of patients with lung cancer, internal target volume frequently is determined by using maximum intensity projection (MIP) images generated by means of four-dimensional computed tomography (4D-CT). To check the accuracy of MIPs for various target motions, especially for targets moving irregularly, we performed phantom studies using a programmable dynamic lung phantom. METHODS AND MATERIALS: A custom-built programmable lung phantom was used to simulate irregular target motions along the superior-inferior direction. After scanning in helical mode using 4D-CT, reconstructed phase and MIP images were imported into the Pinnacle 8.0 treatment planning system for image analysis. RESULTS: For all regular periodic target motions with constant amplitude and period, the measured MIP target span along the superior-inferior direction was accurate within 2-3 mm of the real target motion span. For irregular target motions with varying amplitudes and periods, the measured MIP target span systematically underrepresented the real range of target motion by more than 1 cm in some cases. The difference between measured MIP target span and real target span decreased as the target moved faster. We associate these discrepancies with the fact that current reconstruction algorithms of commercial 4D-CT are based on phase binning. CONCLUSIONS: According to our phantom measurements, MIP accurately reflects the range of target motion for regular target motion. However, it generally underestimates the range of target motion when the motion is irregular in amplitude and periodicity. Clinical internal target volume determination using MIP requires caution, especially when there is breathing irregularity.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Movimento , Imagens de Fantasmas , Tomografia Computadorizada Espiral/métodos , Neoplasias Pulmonares/cirurgia , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador/métodos , Respiração , Carga Tumoral
14.
Expert Rev Anticancer Ther ; 8(12): 1939-51, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19046114

RESUMO

Stereotactic body radiation therapy (SBRT) represents a novel treatment modality for cancer and has been used to treat various types of primary cancer with curative intent. Data on the use of SBRT for various primary sites are emerging. While the largest body of data is concerned with early-stage lung cancer, there is also a fair amount of experience in the treatment of nonpulmonary primary sites with SBRT. This article will provide an overview of radiobiologic, technical and clinical aspects of the use of this emerging treatment modality for various nonpulmonary primary tumors.


Assuntos
Neoplasias/radioterapia , Humanos , Radiocirurgia
15.
Med Phys ; 35(11): 4837-48, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19070217

RESUMO

Derivation of formulas relating leaf speeds and beam dose rates for delivering planned intensity profiles to static and moving targets in dynamic multileaf collimator (DMLC) intensity modulated radiation therapy (IMRT) is presented. The analysis of equations determining algorithms for DMLC IMRT delivery under a variable beam dose rate reveals a multitude of possible delivery strategies for a given intensity map and for any given target motion patterns. From among all equivalent delivery strategies for DMLC IMRT treatments specific subclasses of strategies can be selected to provide deliveries that are particularly suitable for clinical applications providing existing delivery devices are used. Special attention is devoted to the subclass of beam dose rate variable DMLC delivery strategies to moving body anatomy that generalize existing techniques of such deliveries in Varian DMLC irradiation methodology to static body anatomy. Few examples of deliveries from this subclass of DMLC IMRT irradiations are investigated to illustrate the principle and show practical benefits of proposed techniques.


Assuntos
Movimento , Doses de Radiação , Radioterapia de Intensidade Modulada/métodos , Humanos , Dosagem Radioterapêutica
16.
Med Phys ; 35(9): 3875-88, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18841838

RESUMO

An MLC control algorithm for delivering intensity modulated radiation therapy (IMRT) to targets that are undergoing two-dimensional (2D) rigid motion in the beam's eye view (BEV) is presented. The goal of this method is to deliver 3D-derived fluence maps over a moving patient anatomy. Target motion measured prior to delivery is first used to design a set of planned dynamic-MLC (DMLC) sliding-window leaf trajectories. During actual delivery, the algorithm relies on real-time feedback to compensate for target motion that does not agree with the motion measured during planning. The methodology is based on an existing one-dimensional (ID) algorithm that uses on-the-fly intensity calculations to appropriately adjust the DMLC leaf trajectories in real-time during exposure delivery [McMahon et al., Med. Phys. 34, 3211-3223 (2007)]. To extend the 1D algorithm's application to 2D target motion, a real-time leaf-pair shifting mechanism has been developed. Target motion that is orthogonal to leaf travel is tracked by appropriately shifting the positions of all MLC leaves. The performance of the tracking algorithm was tested for a single beam of a fractionated IMRT treatment, using a clinically derived intensity profile and a 2D target trajectory based on measured patient data. Comparisons were made between 2D tracking, 1D tracking, and no tracking. The impact of the tracking lag time and the frequency of real-time imaging were investigated. A study of the dependence of the algorithm's performance on the level of agreement between the motion measured during planning and delivery was also included. Results demonstrated that tracking both components of the 2D motion (i.e., parallel and orthogonal to leaf travel) results in delivered fluence profiles that are superior to those that track the component of motion that is parallel to leaf travel alone. Tracking lag time effects may lead to relatively large intensity delivery errors compared to the other sources of error investigated. However, the algorithm presented is robust in the sense that it does not rely on a high level of agreement between the target motion measured during treatment planning and delivery.


Assuntos
Algoritmos , Movimento (Física) , Simulação por Computador , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Radioterapia de Intensidade Modulada
17.
Med Phys ; 35(8): 3765-78, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18777936

RESUMO

The goal of this article is to present the algorithm for DMLC leaf control capable of delivering IMRT to tumors that experience motion in two dimensions in the beams eye view (BEV) plane. The generic, two-dimensional (2D) motion of the projection of the rigid target on BEV plane can be divided into two components. The first component describes the motion of the projection of the target along the x axis (parallel to the MLC leaf motions) and the other describes the motion of the target projection on the y axis (perpendicular to the leaf motion direction). First, time optimal leaf trajectories are calculated independently for each leaf pair of the MLC assembly to compensate the x-axis component of the 2D motion of the target on the BEV. These leaf trajectories are then synchronized following the mid time (MT) synchronization procedure. To compensate for the y-axis component of the motion of the target projection on the BEV plane, the procedure of "switching" leaf pair trajectories in the upward (or downward) direction is executed when the target's BEV projection moves upward (or downward) from its equilibrium position along the y axis. When the intensity function is a 2D histogram, the error between the intended and delivered intensity in 2D DMLC IMRT delivery will depend on the shape of the intensity map and on the MLC physical constraint (leaf width and maximum admissible leaf speed). The MT synchronization of leaf trajectories decreases the impact of above constraints on the error in 2D DMLC IMRT intensity map delivery. The proof is provided, that if hardware constraints in the 2D DMLC IMRT delivery strategy are removed, the errors between planned and delivered 2D intensity maps are entirely eliminated. Examples of 2D DMLC IMRT delivery to rigid targets moving along elliptical orbits on BEV planes are calculated and analyzed for 20 clinical fluence maps. The comparisons between the intensity delivered without motion correction, with motion correction along x axis only, and with motion correction for full 2D motion of the target are calculated and quantitatively evaluated. The fluence maps were normalized to 100 MU and the rms difference between the desired and delivered fluence was 12 MU for no motion compensation, 11.18 MU for 1D compensation, and 4.73 MU for 2D motion compensations. The advantage of correcting for full 2D motion of target projected on the BEV plane is demonstrated.


Assuntos
Algoritmos , Olho , Movimento (Física) , Radioterapia de Intensidade Modulada/métodos , Artefatos , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/instrumentação , Fatores de Tempo
18.
Technol Cancer Res Treat ; 7(3): 197-206, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18473491

RESUMO

A new stereotactic frame system was designed at Indiana University to utilize the precision motion control of newer accelerator couches and treat obese patients previously untreatable in other frame systems during stereotactic body radiation therapy (SBRT). The repositioning accuracy and target reproducibility of this frame was evaluated in the treatment of both lung and liver tumors. The external coordinate system on the new frame was validated using a phantom system. Translational motions were carried out using couch motors. Five patients were treated with SBRT and twenty-three verification CT scans were acquired. The displacement of the gross tumor volume (GTV) and adjacent vertebral body between the original CT scan and the verification CT scans was determined. The mean setup accuracy for the patient study was less than 5 mm. Mean displacement of the GTV was 3.0 mm (0.0-6.0 mm) in the lateral (x) direction, 4.1 mm (0.0-8.9 mm) in the superior-inferior (y) direction, and 2.6 mm (0.0-10.0 mm) in the cranio-caudal (z) direction. Comparison of vertebral body position showed mean displacement of 2.4 mm (0.0 to 8.0 mm), 1.9 mm (0.0 mm to 2.0 mm), and 0.9 mm (0.0 to 5.0 mm) for the same shift directions. Repositioning could be accurately carried out from an initial reference position using the treatment couch controllers. Adequate set-up accuracy using a frame system capable of accommodating wide girth patients was achieved and was comparable to other published studies for narrower frames. With these results, a 5 mm expansion for PTV margins remains the standard for our institution.


Assuntos
Imobilização/instrumentação , Neoplasias Hepáticas/cirurgia , Neoplasias Pulmonares/cirurgia , Radiocirurgia/instrumentação , Humanos , Obesidade , Imagens de Fantasmas , Radiocirurgia/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
19.
Int J Radiat Oncol Biol Phys ; 70(5): 1571-8, 2008 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-18374231

RESUMO

PURPOSE: To investigate the effectiveness of different abdominal compression levels on tumor and organ motion during stereotactic body radiotherapy of lower lobe lung and liver tumors using four-dimensional (4D)-CT scan analysis. METHODS AND MATERIALS: Three 4D-CT scans were acquired for 10 patients first using with no compression and then compared with two different levels of abdominal compression. The position of the tumor and various organs were defined at the peak inspiratory and expiratory phases and compared to determine the maximum motion. RESULTS: Mean (+/-SD) medium compression force (MC) and high compression force (HC) were 47.6 +/- 16.0 N and 90.7 +/- 27.1 N, respectively. Mean overall tumor motion was 13.6 mm (2sigma [2 sigma] 11.5-15.6), 8.3 mm (2sigma 6.0-10.5), and 7.2 mm (2sigma 5.4-9.0) for no compression, MC, and HC, respectively. A significant difference in the control of both superior-inferior (SI) and overall motion of tumors was seen with the application of MC and HC when compared with no compression (p < 0.0001 for both). High compression force improved SI and overall tumor motion compared with MC, but this was only significant for SI motion (p = 0.04 and p = 0.06). Significant control of organ motion was only seen in the pancreas (p = 0.01). CONCLUSIONS: Four-dimensional CT shows significant control of both lower lobe lung and liver tumors using abdominal compression. High levels of compression improve SI tumor motion when compared with MC.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Movimento , Tomografia Computadorizada por Raios X/métodos , Diafragma/diagnóstico por imagem , Expiração , Humanos , Inalação , Neoplasias Hepáticas/cirurgia , Neoplasias Pulmonares/cirurgia , Pressão , Radiocirurgia
20.
Int J Radiat Oncol Biol Phys ; 70(3): 847-52, 2008 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-18262098

RESUMO

PURPOSE: Overprediction of the potency and toxicity of high-dose ablative radiotherapy such as stereotactic body radiotherapy (SBRT) by the linear quadratic (LQ) model led to many clinicians' hesitating to adopt this efficacious and well-tolerated therapeutic option. The aim of this study was to offer an alternative method of analyzing the effect of SBRT by constructing a universal survival curve (USC) that provides superior approximation of the experimentally measured survival curves in the ablative, high-dose range without losing the strengths of the LQ model around the shoulder. METHODS AND MATERIALS: The USC was constructed by hybridizing two classic radiobiologic models: the LQ model and the multitarget model. We have assumed that the LQ model gives a good description for conventionally fractionated radiotherapy (CFRT) for the dose to the shoulder. For ablative doses beyond the shoulder, the survival curve is better described as a straight line as predicted by the multitarget model. The USC smoothly interpolates from a parabola predicted by the LQ model to the terminal asymptote of the multitarget model in the high-dose region. From the USC, we derived two equivalence functions, the biologically effective dose and the single fraction equivalent dose for both CFRT and SBRT. RESULTS: The validity of the USC was tested by using previously published parameters of the LQ and multitarget models for non-small-cell lung cancer cell lines. A comparison of the goodness-of-fit of the LQ and USC models was made to a high-dose survival curve of the H460 non-small-cell lung cancer cell line. CONCLUSION: The USC can be used to compare the dose fractionation schemes of both CFRT and SBRT. The USC provides an empirically and a clinically well-justified rationale for SBRT while preserving the strengths of the LQ model for CFRT.


Assuntos
Modelos Lineares , Modelos Biológicos , Radiocirurgia , Eficiência Biológica Relativa , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Linhagem Celular Tumoral , Sobrevivência Celular , Dano ao DNA , Reparo do DNA , Fracionamento da Dose de Radiação , Humanos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Radiobiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...