Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 18(9): e0291670, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37725623

RESUMO

The COVID-19 antibody test was developed to investigate the humoral immune response to SARS-CoV-2 infection. In this study, we examined whether S antibody titers measured using the anti-SARS-CoV-2 IgG II Quant assay (S-IgG), a high-throughput test method, reflects the neutralizing capacity acquired after SARS-CoV-2 infection or vaccination. To assess the antibody dynamics and neutralizing potency, we utilized a total of 457 serum samples from 253 individuals: 325 samples from 128 COVID-19 patients including 136 samples from 29 severe/critical cases (Group S), 155 samples from 71 mild/moderate cases (Group M), and 132 samples from 132 health care workers (HCWs) who have received 2 doses of the BNT162b2 vaccinations. The authentic virus neutralization assay, the surrogate virus neutralizing antibody test (sVNT), and the Anti-N SARS-CoV-2 IgG assay (N-IgG) have been performed along with the S-IgG. The S-IgG correlated well with the neutralizing activity detected by the authentic virus neutralization assay (0.8904. of Spearman's rho value, p < 0.0001) and sVNT (0.9206. of Spearman's rho value, p < 0.0001). However, 4 samples (2.3%) of S-IgG and 8 samples (4.5%) of sVNT were inconsistent with negative results for neutralizing activity of the authentic virus neutralization assay. The kinetics of the SARS-CoV-2 neutralizing antibodies and anti-S IgG in severe cases were faster than the mild cases. All the HCWs elicited anti-S IgG titer after the second vaccination. However, the HCWs with history of COVID-19 or positive N-IgG elicited higher anti-S IgG titers than those who did not have it previously. Furthermore, it is difficult to predict the risk of breakthrough infection from anti-S IgG or sVNT antibody titers in HCWs after the second vaccination. Our data shows that the use of anti-S IgG titers as direct quantitative markers of neutralizing capacity is limited. Thus, antibody tests should be carefully interpreted when used as serological markers for diagnosis, treatment, and prophylaxis of COVID-19.


Assuntos
Vacina BNT162 , COVID-19 , Humanos , COVID-19/diagnóstico , COVID-19/prevenção & controle , SARS-CoV-2 , Anticorpos Bloqueadores , Anticorpos Antivirais , Imunoglobulina G
2.
PLoS One ; 18(1): e0279779, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36693058

RESUMO

BACKGROUND: Despite the worldwide campaigns of COVID-19 vaccinations, the pandemic is still a major medical and social problem. The Ortho VITROS SARS-CoV-2 spike-specific quantitative IgG (VITROS S-IgG) assay has been developed to assess neutralizing antibody (NT antibody) against SARS-CoV-2 spike (S) antibodies. However, it has not been evaluated in Japan, where the total cases and death toll are lower than the rest of the world. METHODS: The clinical performance of VITROS S-IgG was evaluated by comparing with the NT antibody levels measured by the surrogate virus neutralizing antibody test (sVNT). A total of 332 serum samples from 188 individuals were used. Of these, 219 samples were from 75 COVID-19 patients: 96 samples from 20 severe/critical cases (Group S), and 123 samples from 55 mild/moderate cases (Group M). The remaining 113 samples were from 113 healthcare workers who had received 2 doses of the BNT162b2 vaccine. RESULTS: VITROS S-IgG showed good correlation with the cPass sVNT assay (Spearman rho = 0.91). Both VITROS S-IgG and cPass sVNT showed significantly higher plateau levels of antibodies in Group S compared to Group M. Regarding the humoral immune responses after BNT162b2 vaccination, individuals who were negative for SARS-CoV-2 nucleocapsid (N)-specific antibodies had statistically lower titers of both S-IgG and sVNT compared to individuals with a history of COVID-19 and individuals who were positive for N-specific antibodies without history of COVID-19. In individuals who were positive for N-specific antibodies, S-IgG and sVNT titers were similar to individuals with a history of COVID-19. CONCLUSIONS: Although the automated quantitative immunoassay VITROS S-IgG showed a reasonable correlation with sVNT antibodies, there is some discrepancy between Vitros S-IgG and cPass sVNT in milder cases. Thus, VITROS S-IgG can be a useful diagnostic tool in assessing the immune responses to vaccination and herd immunity. However, careful analysis is necessary to interpret the results.


Assuntos
Antígenos de Grupos Sanguíneos , COVID-19 , Humanos , Vacina BNT162 , SARS-CoV-2 , Anticorpos Bloqueadores , Anticorpos Antivirais , Imunoglobulina G , Anticorpos Neutralizantes , Teste para COVID-19
3.
Eur Cytokine Netw ; 33(2): 25-36, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36266985

RESUMO

Treatment of severe and critical cases of coronavirus disease 2019 (COVID-19) is still a top priority in public health. Previously, we reported distinct Th1 cytokines related to the pathophysiology of severe COVID-19 condition. In the present study, we investigated the association of Th1 and Th2 cytokine/chemokine endotypes with cell-mediated immunity via multiplex immunophenotyping, single-cell RNA-Seq analysis of peripheral blood mononuclear cells, and analysis of the clinical features of COVID-19 patients. Based on serum cytokine and systemic inflammatory markers, COVID-19 cases were classified into four clusters of increasing (I-IV) severity. Two prominent clusters were of interest and could be used as prognostic reference for a targeted treatment of severe COVID-19 cases. Cluster III reflected severe/critical pathology and was characterized by decreased in CCL17 levels and increase in IL-6, C-reactive protein CXCL9, IL-18, and IL-10 levels. The second cluster (Cluster II) showed mild to moderate pathology and was characterized by predominated CXCL9 and IL-18 levels, levels of IL-6 and CRP were relatively low. Cluster II patients received anti-inflammatory treatment in early-stage, which may have led prevent disease prognosis which is accompanied to IL-6 and CRP induction. In Cluster III, a decrease in the proportion of effector T cells with signs of T cell exhaustion was observed. This study highlights the mechanisms of endotype clustering based on specific inflammatory markers in related the clinical outcome of COVID-19.


Assuntos
COVID-19 , Citocinas , Humanos , Interleucina-10 , Interleucina-18 , Proteína C-Reativa , Interleucina-6 , Leucócitos Mononucleares , Quimiocinas , Biomarcadores
4.
Sci Rep ; 12(1): 14909, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050347

RESUMO

COVID-19 antibody testing has been developed to investigate humoral immune response in SARS-CoV-2 infection. To assess the serological dynamics and neutralizing potency following SARS-CoV-2 infection, we investigated the neutralizing (NT) antibody, anti-spike, and anti-nucleocapsid antibodies responses using a total of 168 samples obtained from 68 SARS-CoV-2 infected patients. Antibodies were measured using an authentic virus neutralization assay, the high-throughput laboratory measurements of the Abbott Alinity quantitative anti-spike receptor-binding domain IgG (S-IgG), semiquantitative anti-spike IgM (S-IgM), and anti-nucleocapsid IgG (N-IgG) assays. The quantitative measurement of S-IgG antibodies was well correlated with the neutralizing activity detected by the neutralization assay (r = 0.8943, p < 0.0001). However, the kinetics of the SARS-CoV-2 NT antibody in severe cases were slower than that of anti-S and anti-N specific antibodies. These findings indicate a limitation of using the S-IgG antibody titer, detected by the chemiluminescent immunoassay, as a direct quantitative marker of neutralizing activity capacity. Antibody testing should be carefully interpreted when utilized as a marker for serological responses to facilitate diagnostic, therapeutic, and prophylactic interventions.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Neutralizantes , Anticorpos Antivirais , Teste para COVID-19 , Humanos , Imunoglobulina G , Imunoglobulina M , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...