Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heart Lung Circ ; 31(12): 1677-1684, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36089464

RESUMO

AIM: The Occlutech duct occluder (ODO) with a novel design has been available for closure of patent ductus arteriosus (PDA) since 2011. Available data on initial experience with the ODO have shown that operators continue to choose device sizes based on their experience with conventional duct occluders (CDO). This study postulated that occlusion of the pulmonary arterial (PA) end of the ductus should achieve satisfactory PDA closure without additional complications. Accordingly, the size of the ODO was chosen such that the larger PA diameter in the new design exceeded the PA end of the ductus by 2-3 mm and 2-4 mm for normotensive and hypertensive ducts, respectively. It sought to examine the feasibility and safety of such an approach, and compared ODO and CDO devices with respect to device sizes deployed, to ascertain if the newer design had any advantages. METHODS: This prospective study enrolled 105 infants, children and a few adults with various duct morphologies and PA pressures for ductal closure using the ODO from 2018-2020. The control group consisted of 105 ducts closed with CDO. A comparison of the two groups with respect to duct diameter and implanted device sizes was performed using appropriate statistical software. RESULTS: The study found that 40% of the ducts had moderate-to-severe pulmonary hypertension. Most ducts measured between 3-4 mm in both groups. The mean weight of the subjects in both groups was 12 kg. Although there was no change in the way that duct occluders were chosen in both groups (2-3 mm over the pulmonary artery diameter), ODO could be significantly downsized in most ducts measuring between 2.5-6.4 mm in diameter (p<0.05). CONCLUSIONS: This study found successful closure of relatively larger PDA in infants and children using smaller ODO compared with CDO, without embolisation or aortic narrowing. It also demonstrated that a different device size selection technique may be safely employed with the ODO.


Assuntos
Permeabilidade do Canal Arterial , Dispositivo para Oclusão Septal , Criança , Lactente , Adulto , Humanos , Resultado do Tratamento , Estudos Prospectivos , Cateterismo Cardíaco/métodos , Desenho de Prótese , Permeabilidade do Canal Arterial/cirurgia
2.
Asian Cardiovasc Thorac Ann ; 30(5): 589-592, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34171970

RESUMO

Ventricular septal defects are increasingly being closed by transcatheter technique, with lesser morbidity and shorter hospital stay compared to open heart surgery. We report a case of embolization of a duct occluder deployed in a posterior muscular septal defect. The rare site of embolization necessitated an unusual approach for retrieval prior to subsequent closure using a double-disc device.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Comunicação Interventricular , Dispositivo para Oclusão Septal , Artéria Axilar/diagnóstico por imagem , Artéria Axilar/cirurgia , Cateterismo Cardíaco , Comunicação Interventricular/cirurgia , Humanos , Resultado do Tratamento
3.
Ann Pediatr Cardiol ; 14(4): 550-553, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35527767

RESUMO

Anomalies of systemic venous connections are extremely rare. We describe the case of an asymptomatic 29-year-old woman who was found to have systemic desaturation in the peripartum period and referred to us for suspected cyanotic heart disease. She was diagnosed to have hemianomalous systemic venous connection of the inferior vena cava (IVC) into the left atrium (LA). Transesophageal echocardiogram with contrast diagnosed anomalous connection of the IVC to the LA, further confirmed by computed tomography and conventional angiography. The patient underwent successful surgical correction with an uneventful postoperative course.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...