Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Clin Med ; 13(12)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38929948

RESUMO

Background: Esophageal self-expandable metal stents (SEMS) are an important endoscopic tool. These stents have now been adapted successfully to manage post-bariatric surgery complications such as anastomotic leaks and strictures. In centers of expertise, this has become the primary standard-of-care treatment given its minimally invasive nature, and that it results in early oral feeding, decreased hospitalization, and overall favorable outcomes. Self-expandable metal stents (SEMS) fractures are a rare complication of unknown etiology. We aimed to investigate possible causes of SEMS fractures and highlight a unique endoscopic approach utilized to manage a fractured and impaled SEMS. Methods: This is a retrospective study of consecutive patients who underwent esophageal SEMS placement between 2015-2021 at a tertiary referral center to identify fractured SEMS. Patient demographics, stent characteristics, and possible etiologies of fractured SEMS were identified. A comprehensive literature review was also conducted to evaluate all prior cases of fractured SEMS and to hypothesize fracture theories. Results: There were seven fractured esophageal SEMS, of which six were used to manage post-bariatric surgery complications. Five SEMS were deployed with their distal ends in the gastric antrum and proximal ends in the distal esophagus. All stents fractured within 9 weeks of deployment. Most stents (5/7) were at least 10 cm in length with fractures commonly occurring in the distal third of the stents (6/7). The wires of a fractured SEMS were embedded within the esophagogastric junction in one case, prompting the use of an overtube that was synchronously advanced while steadily extracting the stent. Discussion: We suggest the following four etiologies of SEMS fractures: anatomical, physiological, mechanical, and chemical. Stent curvature at the stomach incisura can lead to strain- and stress-related fatigue due to mechanical bending with exacerbation from respiratory movements. Physiologic factors (gastric body contractions) can result in repetitive squeezing of the stent, adding to metal fatigue. Intrinsic properties (long length and low axial force) may be contributing factors. Lastly, the stomach acidic environment may cause nitinol-induced chemical weakness. Despite the aforementioned theories, SEMS fracture etiology remains unclear. Until more data become available, it may be advisable to remove these stents within 6 weeks.

2.
Pancreas ; 52(2): e115-e120, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-37523602

RESUMO

OBJECTIVES: The aim of this study was to assess the safety, feasibility, and reproducibility of endoscopic ultrasound shear wave elastography (EUS-SWE) in the pancreas. METHODS: This is a prospective registry of consecutive patients undergoing clinically indicated EUS. Ten readings of SWE velocities (Vs [distance/time, m/s]) were obtained in the head (HOP), body, and tail of pancreas to quantify tissue stiffness. Each Vs score was accompanied by a reliability measurement VsN (%) with VsN >50% considered reliable. Safety was evaluated by perioperative complications rate. Feasibility was determined by technical success of obtaining measurements. Reproducibility was evaluated using intraclass correlation coefficient analysis. RESULTS: Total of 3320 EUS-SWE measurements were performed on 117 patients without perioperative complications. Measurement success rate was 100% across all locations. Reliable measurements were more common in the HOP (953/1120 [85.1%]) followed by body (853/1130 [75.5%]) and tail of pancreas (687/1070 [64.2%]) (P < 0.001). The analysis showed good reproducibility in all locations (intraclass correlation coefficient range, 0.80-0.89). CONCLUSIONS: Endoscopic ultrasound-SWE is safe, has 100% technical success rate, and is highly reproducible when used in the pancreas. Our study suggests that SWE measurements in the HOP offer the highest reliability, likely because of large study area and less respiratory artifact.


Assuntos
Técnicas de Imagem por Elasticidade , Pâncreas , Ultrassonografia de Intervenção , Humanos , Estudos de Viabilidade , Pâncreas/diagnóstico por imagem , Reprodutibilidade dos Testes
3.
J Gastroenterol Hepatol ; 38(4): 584-589, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36582040

RESUMO

BACKGROUND AND AIM: Dedicated studies evaluating the impact of COVID-19 on outcomes of pancreatobiliary IgG4 related disease (IgG4-RD) patients are scarce. Whether COVID-19 infection or vaccination would trigger IgG4-RD exacerbation remains unknown. METHODS: Pancreatobiliary IgG4-RD patients ≥ 18 years old with active follow-up since January 2020 from nine referral centers in Asia, Europe, and North America were included in this multicenter retrospective study. Outcome measures include incidence and severity of COVID-19 infection, IgG4-RD disease activity and treatment status, interruption of indicated IgG4-RD treatment. Prospective data on COVID-19 vaccination status and new COVID-19 infection during the Omicron outbreak were also retrieved in the Hong Kong cohort. RESULTS: Of the 124 pancreatobiliary IgG4-RD patients, 25.0% had active IgG4-RD, 71.0% were on immunosuppressive therapies and 80.6% had ≥ 1 risk factor for severe COVID. In 2020 (pre-vaccination period), two patients (1.6%) had COVID-19 infection (one requiring ICU admission), and 7.2% of patients had interruptions in indicated immunosuppressive treatment for IgG4-RD. Despite a high vaccination rate (85.0%), COVID-19 infection rate has increased to 20.0% during Omicron outbreak in the Hong Kong cohort. A trend towards higher COVID-19 infection rate was noted in the non-fully vaccinated/unvaccinated group (17.6% vs 33.3%, P = 0.376). No IgG4-RD exacerbation following COVID-19 vaccination or infection was observed. CONCLUSION: While a low COVID-19 infection rate with no mortality was observed in pancreatobiliary IgG4-RD patients in the pre-vaccination period of COVID-19, infection rate has increased during the Omicron outbreak despite a high vaccination rate. No IgG4-RD exacerbation after COVID-19 infection or vaccination was observed.


Assuntos
COVID-19 , Doença Relacionada a Imunoglobulina G4 , Humanos , Adolescente , Estudos Retrospectivos , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Estudos Prospectivos , Imunoglobulina G , Vacinação , Hong Kong/epidemiologia
4.
Endosc Int Open ; 10(11): E1481-E1490, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36397866

RESUMO

Background and study aims Acute iatrogenic endoscopic perforations (AIEPs) can have high morbidity and mortality, especially colonic perforations. Knowledge of diagnosis and AIEP management can improve patient care. The aims of this study were to: develop an evidence-based AIEP management algorithm; study its short-term and long-term impact on physician knowledge; and evaluate physician knowledge using hypothetical clinical scenarios. Methods An institutional AIEP management algorithm was created using the most current recommendations from the American Society for Gastrointestinal Endoscopy and the European Society of Gastrointestinal Endoscopy. Input from advanced endoscopists, nurses, and anesthesiologists was also obtained. We assessed change in physician knowledge using a 10-item questionnaire before (pretest), a standardized one-page AIEP educational material and algorithm immediately after (post-test) to test short-term retention, and 6 months later (6-month reassessment) to test long-term retention. With the 6-month reassessment, two clinical scenarios based on real AIEP were presented to evaluate application of knowledge. Results Twenty-eight subjects (8 gastroenterology fellows and 20 practicing gastroenterologists) participated in the assessments. Pretest and immediate post-test accuracies were 75 % and 95 % ( P  < 0.01), respectively. Six-month reassessment accuracies were 83.6 %, significantly worse compared to post-test accuracies ( P  < 0.05), but significantly improved compared to pretest accuracies ( P  < 0.05). Accuracies for clinical scenarios #1 and #2 were 67.5 % and 60.3 %, respectively. Fellows had similar accuracies when compared to practicing gastroenterologists. Conclusions Using standardized methodology and a multidisciplinary approach, an AIEP management algorithm was created to improve patient care and alleviate physician and staff stress. In addition, we showed that a one-page educational document on perforations can significantly improve short-term and long-term physician knowledge, although periodic reeducation is needed.

7.
Gastrointest Endosc ; 96(5): 771-779, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35697128

RESUMO

BACKGROUND AND AIMS: Endoscopic suturing and over-the-scope clips (OTSCs) are used to prevent migration of fully covered self-expandable metal stents (FCSEMSs). Recently, a dedicated OTSC was developed for securing FCSEMSs. Our primary aim was to compare the frequency of stent migration without stent fixation versus fixation with suturing or OTSCs, and out secondary aims were to compare clinical success, procedure duration, and adverse events. METHODS: A retrospective cohort study evaluated the outcome of stent placement throughout the entire GI tract from 2013 to 2021. Stent migration was determined as stent displacement ≥2 cm endoscopically or radiographically. Clinical success was defined as resolution of indication at follow-up. RESULTS: Four hundred thirty-three procedures were performed, 239 (55%) without fixation, 140 (32%) with suturing, and 54 (12%) with OTSCs. Stent migration rates were 62% without fixation, 57% with suturing, and 35% with OTSCs (P = .013). The median time to stent migration was 3 weeks without fixation, 5 weeks with suturing, and 6 weeks with OTSCs (P = .023). The clinical success rate was 43%. The median procedure time for OTSCs was shorter compared with suturing (42 vs 68 minutes, P = .002). Adverse event rates trended toward being lowest with OTSCs at 9% compared with 21% without fixation and 18% with suturing (P > .05). CONCLUSIONS: OTSCs for stent fixation were found to have significantly lower migration rates compared with no fixation and suturing. Moreover, OTSCs were associated with decreased overall procedure time and total costs per procedure while trending to be associated with fewer adverse events.


Assuntos
Stents Metálicos Autoexpansíveis , Técnicas de Sutura , Humanos , Estudos Retrospectivos , Suturas , Stents Metálicos Autoexpansíveis/efeitos adversos , Stents , Esofagoscopia/métodos , Resultado do Tratamento
8.
J Pediatr Gastroenterol Nutr ; 74(1): 20-24, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34347680

RESUMO

OBJECTIVES: Endoscopic mucosal resection (EMR) for removal of large polyps is well established in adults. EMR technique in the pediatric population is less utilized due to lower incidence of large intestinal polyps in pediatric patients and limited EMR training for pediatric gastroenterologists. The aim of this study is to retrospectively review safety and efficacy of pediatric EMR cases at two large, tertiary referral centers with adult and pediatric EMR expertise. METHODS: A retrospective chart review was conducted at Cedars-Sinai Medical Center and Cincinnati Children's Hospital Medical Center from January 2012 to May 2021. Demographic, clinical, technical and follow up data were collected for patients <18 years of age who underwent EMR during the study period. RESULTS: Fifteen pediatric EMR procedures were identified in 11 patients (five male, six female) during the study period. Indication was most frequently rectal bleeding. Polyp size removed ranged from 9 to 60 mm and pathology was consistent with juvenile inflammatory polyps in six patients. Technical success was achieved in 14 of 15 (93%) of EMRs with clinical success (desired clinical outcome) in all 13 procedures with clinical follow-up. There were no adverse events. CONCLUSIONS: This study identifies a case series of pediatric patients who underwent EMR at two tertiary care centers. This series demonstrates successful EMR in children and shows a high technical and clinical success rate with a low complication rate. More investigation into EMR in pediatric patients is necessary, and its use should be isolated to centers with endoscopists with specific experience in EMR techniques.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Adulto , Criança , Pólipos do Colo/patologia , Pólipos do Colo/cirurgia , Colonoscopia/métodos , Ressecção Endoscópica de Mucosa/efeitos adversos , Ressecção Endoscópica de Mucosa/métodos , Feminino , Humanos , Mucosa Intestinal/patologia , Mucosa Intestinal/cirurgia , Pólipos Intestinais/etiologia , Masculino , Estudos Retrospectivos , Resultado do Tratamento
9.
Surg Obes Relat Dis ; 15(6): 850-855, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31122826

RESUMO

BACKGROUND: Sleeve gastrectomy is the most commonly performed bariatric surgery in the United States. Leaks after sleeve gastrectomy (SGL) occur in 1% to 3% of patients. Endoscopic therapies are increasingly used for treatment of SGLs, but few data exist on their outcomes. OBJECTIVES: The aim of this study was to assess technical success, leak resolution, and reoperation rates of patients undergoing endoscopic therapy for repair SGLs. SETTING: Eight high-volume academic endoscopy centers. METHODS: Patients undergoing endoscopic therapy for SGLs from 2007 to 2017 were identified. Patients were excluded if the index endoscopic therapy for SGL was performed elsewhere or if no follow-up data were available. Leaks were classified as acute (≤7 d of SG), early (1-6 wk), late (7-12 wk), and chronic (>12 wk). Leak resolution was defined as lack of extraluminal air, extravasation on oral contrast radiography, cross-sectional imaging, or resolution of percutaneous drain output. Demographic and procedural data were recorded as rates of additional therapy, adverse events, and surgical revision. RESULTS: A total of 85 patients met criteria for analysis (70 women, age 42.6 ± 10.8 yr). A total of 295 endoscopic sessions (median 3, range 1-14) were performed across the cohort. SGLs resolved after index endoscopic therapy in 43 (50.1%) patients. The primary outcome of endoscopic resolution of SGL was observed in 62 patients (72.9%). There were 34 (11.5%) PRAE (the majority occurring with self-expandable metal stents), all but 1 of which were managed endoscopically. Surgical revision was required in 23 (21.7%) patients. On univariate analyses independent variables associated with the need for surgical revision included both acute and chronic SGLs (P = .028), loculated subphrenic collections/abscesses (P = .03), and intraabdominal sepsis (P = .03). On multivariable logistic regression using statistically significant predictors from the univariate analyses, acute SGLs were significantly associated with a need for surgical revision (odds ratio 4.8, 95% confidence interval 1.2-18.9, P = .025). CONCLUSION: Endoscopic therapy for SGLs is associated with good clinical success, avoiding the need for surgical revision in 73% of patients, with an acceptable adverse event profile. Patients with acute or chronic SGLs and those with loculated abscesses or intraabdominal sepsis are more likely to undergo surgical revision. Endoscopic therapy is an appropriate first-line modality for the management of SGLs, especially those not classified as acute or chronic.


Assuntos
Fístula Anastomótica/cirurgia , Cirurgia Bariátrica/efeitos adversos , Endoscopia Gastrointestinal , Gastrectomia/efeitos adversos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Estados Unidos , Adulto Jovem
10.
J Clin Anesth ; 20(8): 580-8, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19100930

RESUMO

STUDY OBJECTIVE: To study the development and implementation of a hospital-wide protocol regarding preoperative beta-blocker therapy. DESIGN: Prospective, observational clinical study. SETTING: Preoperative test center at a university hospital. PATIENTS: 1,000 consecutive patients presenting for a preoperative visit and scheduled for same-day admit surgery. INTERVENTIONS: An algorithm of indications and contraindications for beta-blocker therapy was designed. Data were collected prospectively on 1,000 consecutive patients between June 1, 2004 and August 31, 2004. MEASUREMENTS: Data collected included patient demographics, medication history, risk factors, indications and contraindications to beta-blocker therapy, as well as surgical risk stratification and postoperative complications. MAIN RESULTS: 960 of the 1,000 patients underwent surgery and had complete information for the study collected. 169 patients (17.6%) were receiving beta blockers prior to evaluation. Of the patients having high-risk surgery, 72% had a major or minor indication for beta-blocker therapy without contraindication. Of the patients having intermediate or low-risk surgery, 10% had a major indication for beta blockers without contraindication. Overall, 52% (409/791) of the patients who were candidates for perioperative beta blockers were not receiving them. Some type of complication was experienced by 59 (6.1%) patients. CONCLUSIONS: Development, implementation, and monitoring of perioperative beta-blocker therapy protocols is necessary, as a significant number of appropriate patients do not receive this therapy.


Assuntos
Antagonistas Adrenérgicos beta/administração & dosagem , Protocolos Clínicos , Assistência Perioperatória/normas , Guias de Prática Clínica como Assunto , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Algoritmos , Contraindicações , Feminino , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Complicações Pós-Operatórias/prevenção & controle , Cuidados Pré-Operatórios/normas , Estudos Prospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...