Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
J Arthroplasty ; 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38462143

RESUMO

BACKGROUND: Intraosseous (IO) administration of vancomycin at the time of total knee arthroplasty (TKA) has been shown to be safer and more effective than intravenous (IV) administration at preventing early periprosthetic joint infection. Previous studies have relied on tourniquet inflation to enhance local tissue concentrations and mitigate systemic release. METHODS: A single-blinded, randomized clinical trial was performed on 20 patients (10 IV, 10 IO) undergoing primary TKA. The control (IV) group received weight-dosed vancomycin approximately 1 hour prior to the incision and weight-dosed cefazolin immediately prior to the incision. The interventional (IO) group received weight-dosed cefazolin immediately prior to the incision and 500 mg of vancomycin delivered via the IO technique at the time of the incision. Systemic samples for vancomycin levels were taken prior to the incision and at closure. During the procedure, tissue samples were taken from the distal femur, proximal tibia, and suprapatellar synovium. There were no differences in patient demographics or changes in serum creatinine from preoperative to postoperatively between groups. RESULTS: Significant differences in systemic vancomycin levels (ug/mL) were found at the start of the case (IV = 27.9 ± 4.9 versus IO = 0 ± 0, P = .0004) and at the end of the case (IV = 19.6 ± 2.6 versus IO = 7.8 ± 1.0, P = .001). No significant differences were seen in the average vancomycin concentration in the distal femur (IV = 61.0 ± 16.0 versus IO = 66.2 ± 12.3, P = .80), proximal tibia (IV = 52.8 ± 13.5 versus IO = 57.1 ± 17.0, P = .84), or suprapatellar synovial tissue (IV = 10.7 ± 5.3 versus IO = 9.0 ± 3.3, P = .80). There were no complications associated with vancomycin administration in either group. CONCLUSIONS: This study demonstrates the utility of IO vancomycin in tourniquetless TKA with similar local tissue and significantly lower systemic concentrations than IV administration. LEVEL OF EVIDENCE: Level 1 therapeutic randomized trial.

2.
HSS J ; 20(1): 96-101, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38356758

RESUMO

Background: In the COVID-19 era, there has been increasing interest in same-day discharge (SDD) after total joint arthroplasty (TJA). However, patient perception of SDD is not well reported. Purpose: We sought to understand patients' perceptions and preferences of postoperative care by surveying patients who have completed both an overnight stay (ONS) and an SDD after TJA. Methods: We emailed survey links to 67 patients who previously underwent either 2 total hip arthroplasties (THAs) or 2 total knee arthroplasties (TKAs). Results: Fifty-two patients (78%) responded to the survey. Thirty-four (65%) patients underwent staged, bilateral TKAs, and 18 (35%) patients underwent staged, bilateral THAs. Overall, 63% of patients preferred their SDD, 12% had no preference, and 25% preferred their ONS, with no difference in preference between TKA and THA groups. Those who preferred their SDD reported being more comfortable at home. Those who preferred their ONS felt their pain and concerns were better addressed. No differences were found in comfort, sleep quality, appetite, burden on family, return to function, feelings of being discharged too soon, overall experience, 30-day emergency department (ED) visits, or readmissions within 30 days between patients' SDD and ONS. There was a small statistically significant difference between patients' perception of safety between SDD and ONS. Conclusion: Our survey found that most patients reported a preference for SDD after TJA over ONS. Although there was a small difference in patient perception of safety, there were no differences in return to the ED or readmissions after SDD and ONS.

3.
Arthroplast Today ; 23: 101196, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37745954

RESUMO

Background: Robotic-assisted total knee arthroplasty (rTKA) has been shown to reduce the number of alignment outliers and to improve component positioning compared to manual TKA (mTKA). The primary purpose of this investigation was to compare the frequency of achieving target postoperative limb alignment and component positioning for rTKA vs mTKA. Methods: A retrospective comparative study was performed on 250 patients undergoing primary TKA by 2 fellowship-trained arthroplasty surgeons. Surgeon A performed predominantly rTKA (103 cases) with the ROSA system (Zimmer Biomet, Warsaw, IN) and less frequently mTKA (44 cases) with conventional instrumentation. Surgeon B performed only mTKA (103 cases). Target limb alignment for surgeon A was 0° for all cases and for surgeon B was 2° varus for varus knees and 0° for valgus knees. Radiographic measurements were determined by 2 reviewers. Target zone was set at ± 2 degrees from the predefined target. Results: When comparing rTKA to mTKA performed by different surgeons, there were no differences in the percentage within the target zone (57.28% vs 53.40%, P = .575), but rTKA did result in a greater percentage for cases with preoperative valgus (71.42% vs 44.12%, P = .031). Patient-reported Outcomes Measurement Information System Global-10 physical scores were statistically higher at both 3 (P = .016) and 6 months (P = .001) postoperatively for rTKA compared to mTKA performed by different surgeons. Conclusions: Although experienced surgeons can achieve target limb alignment correction with similar frequency when comparing rTKA to mTKA for all cases, rTKA may achieve target limb alignment with more accuracy for preoperative valgus deformity. Level of Evidence: Retrospective Cohort Study, Level III.

4.
Arthroplast Today ; 23: 101200, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37745964

RESUMO

Background: Many institutions require the routine collection of pathology samples from every primary total knee arthroplasty (TKA) performed. These policies are controversial, and their cost-effectiveness is difficult to define. We sought to judge the cost-effectiveness of one such policy according to World Health Organization recommendations. Methods: We analyzed 3200 consecutive primary TKAs, comparing our presumed preoperative diagnoses against the diagnoses made by the pathologist. Diagnoses were categorized as concordant (matching), discrepant (not matching but without impact to patient management), or discordant (not matching and resulting in a direct change to patient management). An incremental cost-utility ratio analysis was performed to determine the cost-effectiveness of our institution's policy to routinely collect pathology samples from every primary TKA performed. Cost-effectiveness was defined by World Health Organization guidelines as a cost of less than $228,090 per quality-adjusted life year gained. Results: Twelve pathology samples were lost before reaching a pathologist. From the remaining 3188 samples, we identified 3158 concordant cases, 29 discrepant diagnoses, and 1 discordant diagnosis. It cost an estimated $10,522.60 to identify each discrepant diagnosis and an estimated $305,155.36 to diagnose one discordant case in our cohort. Our incremental cost-utility ratio analysis revealed that we spent $305,155.36 to gain 0 quality-adjusted life years for our patients. Conclusions: Routine histopathologic analysis of TKA samples was cost-ineffective in our patient cohort and may not be necessary during routine TKA.

5.
J Am Acad Orthop Surg ; 31(19): e769-e777, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37647539

RESUMO

Hip abductor tears have recently gained recognition as a more prevalent injury than previously thought. This article will detail the pathophysiology of injury, physical symptoms commonly found at presentation, diagnostic imaging to best diagnose tears and when they should be ordered, and how to properly classify the injury and finally summarize the treatment options available with expert opinions about which are most successful.


Assuntos
Bursite , Lesões do Quadril , Músculo Esquelético , Humanos , Bursite/diagnóstico , Bursite/terapia , Músculo Esquelético/lesões , Lesões do Quadril/terapia
6.
Knee ; 43: 129-135, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37399631

RESUMO

BACKGROUND: Multimodal pain management regimens and intraosseous infusion of morphine are two novel techniques that show promise in decreasing postoperative pain and opioid consumption following total knee arthroplasty. However, no study has analyzed the intraosseous infusion of a multimodal pain management regimen in this patient population. The purpose of our investigation was to examine the intraosseous administration of a multimodal pain regimen comprised of morphine and ketorolac during total knee arthroplasty with regard to immediate and 2-week postoperative pain, opioid pain medication intake, and nausea levels. METHODS: In this prospective cohort study with comparisons to a historical control group, 24 patients were prospectively enrolled to receive an intraosseous infusion of morphine and ketorolac dosed according to age-based protocols while undergoing total knee arthroplasty. Immediate and 2-week postoperative Visual Analog Score (VAS) pain scores, opioid pain medication intake, and nausea levels were recorded and compared against a historical control group that received an intraosseous infusion of morphine alone. RESULTS: During the first four postoperative hours, patients who received the multimodal intraosseous infusion experienced lower VAS pain scores and required less breakthrough intravenous pain medication than those patients in our historical control group. Following this immediate postoperative period, there were no additional differences between groups in terms of pain levels or opioid consumption, and there were no differences in nausea levels between groups at any time. CONCLUSIONS: Our multimodal intraosseous infusion of morphine and ketorolac dosed according to age-based protocols improved immediate postoperative pain levels and reduced opioid consumption in the immediate postoperative period for patients undergoing total knee arthroplasty.


Assuntos
Analgésicos Opioides , Artroplastia do Joelho , Humanos , Analgésicos Opioides/uso terapêutico , Morfina/uso terapêutico , Cetorolaco/uso terapêutico , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Estudos Prospectivos , Infusões Intraósseas , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Náusea/tratamento farmacológico
7.
J Arthroplasty ; 38(7S): S11-S15, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37088221

RESUMO

BACKGROUND: Literature shows that intraosseous (IO) infusions are capable of providing increased local concentrations compared to those administered via intravenous (IV) access. Successes while using the technique for antibiotic prophylaxis administration in total knee arthroplasty (TKA) prompted consideration for use in total hip arthroplasty (THA) however; no study exists for the use of IO vancomycin in THA. METHODS: This single-blinded randomized control trial was performed from December 2020 to May 2022. Twenty patients were randomized into 1 of 2 groups: IV vancomycin (15 mg/kg) given routinely, or IO vancomycin (500 mg/100cc of NS) injected into the greater trochanter during incision. Serum vancomycin levels were collected at incision and closure. Soft tissue vancomycin levels were taken from the gluteus maximus (at start and end of case), and acetabular pulvinar tissue. Bone vancomycin levels were taken from the femoral head, acetabular reamings, and intramedullary bone. Adverse local/systemic reactions, 30-day complications, and 90-day complications were also tracked. RESULTS: A statistically significant reduction in serum vancomycin levels was seen when comparing IO to IV vancomycin at both the start and at the end of the procedure. All local tissue samples had higher concentrations of vancomycin in the IO group. Statistically significant increases were present within the acetabular bone reamings, and approached significance in intramedullary femoral bone. CONCLUSION: This study demonstrates the utility of IO vancomycin in primary THA with increased local tissue and decreased systemic concentrations. With positive findings in an area without tourniquet use, IO may be considered for antibiotic delivery for alternative procedures.


Assuntos
Artroplastia de Quadril , Distinções e Prêmios , Infecções Relacionadas à Prótese , Ferida Cirúrgica , Humanos , Vancomicina , Artroplastia de Quadril/efeitos adversos , Antibacterianos/uso terapêutico , Antibioticoprofilaxia/métodos , Ferida Cirúrgica/complicações , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/tratamento farmacológico
8.
J Arthroplasty ; 38(7): 1342-1348, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36731584

RESUMO

BACKGROUND: Modern fluted titanium-tapered stems (FTTS) have been increasingly utilized to achieve primary stability in conversion and revision total hip arthroplasty with major femoral bone loss. This study sought to determine the radiographic and clinical outcomes of a monoblock FTTS in patients who had major femoral bone loss. METHODS: A multicenter retrospective observational study of all total hip arthroplasty patients who received a monoblock FTTS who had up to 5-year radiographic follow-up was conducted. Only patients with femoral Paprosky classifications of IIIa, IIIb, and IV were included. Eighty-one monoblock FTTS were examined. Median clinical follow-up was 29 months (range, 18 to 58). Stem subsidence and loosening were assessed on most recent radiographs. All-cause revisions and stem survivals were assessed. RESULTS: Median subsidence was 1.4 millimeters (mm) (range, 0 to 15.0). Sixteen (23.9%) and 3 (4.5%) stems had subsidence greater than 5 and 10 mm, respectively. All stems not acutely revised appeared stable, without evidence of loosening, at latest follow-up. Ten hips (12.3%) required reoperations. Of these, only 5 (6.2%) stems were removed; 4 due to periprosthetic joint infection and 1 for surgical exposure during acetabular revision. Kaplan-Meier analyses yielded an all-cause stem survivorship of 95.1% at 2-years and 87.1% at 4-years. Stem survivorships excluding septic causes was 98.8% at both 2 and 4 years. CONCLUSION: Monoblock FTTS in complex femoral reconstruction cases showed encouraging clinical and radiographic results in patients who had severe femoral bone loss at median 29 months follow-up.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Prótese de Quadril/efeitos adversos , Osseointegração , Titânio , Desenho de Prótese , Artroplastia de Quadril/efeitos adversos , Reoperação , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Estudos Retrospectivos , Seguimentos , Falha de Prótese
9.
Front Surg ; 10: 1106608, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36843989

RESUMO

Total knee arthroplasty is one of the most widely performed surgical procedures today. Its widespread popularity has helped drive innovation and improvement in the field. Different schools of thought have developed regarding the best way to perform this operation. Specifically, there are controversaries regarding the best alignment philosophy for the femoral and tibial components to optimize implant stability and longevity. Traditionally, neutral mechanical alignment has been the preferred alignment target. More recently, some surgeons advocate for alignment matching the patient's pre-arthritic anatomic alignment ("physiologic" varus or valgus), which has been described as kinematic alignment. Functional alignment is a hybrid technique that focuses on the coronal plane minimizing soft tissue releases. To date, there is no evidence demonstrating superiority of one method over another. There is growing popularity of robotic surgical techniques to improve accuracy of implant position and alignment. The choice of alignment philosophy is an important aspect of robotic assisted TKA surgery and has the potential to clarify the optimal alignment technique.

10.
Arthroplast Today ; 20: 101103, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36844656

RESUMO

Background: Successful fixation of the greater trochanter (GT) in total hip arthroplasty (THA) is a challenging task. A wide range of clinical results are reported in the literature despite advancements in fixation technology. Previous studies may have lacked adequate sample sizes to detect differences. This study evaluates nonunion and reoperation rates and determines factors influencing successful fixation of the GT using current-generation cable plate devices. Methods: This retrospective cohort study included 76 patients who underwent surgery requiring fixation of their GT and had at least 1-year radiographic follow-up. Indications for a surgery were periprosthetic fracture (n = 25), revision THA requiring an extended trochanteric osteotomy (n = 30), GT fracture (n = 3), GT fracture nonunion (n = 9), and complex primary THA (n = 3). Primary outcomes were radiographic union and reoperation. Secondary objectives were patient and plate factors influencing radiographic union. Results: At a mean radiographic follow-up of 2.5 years, the union rate was 76.3% with a nonunion rate of 23.7%. Twenty-eight patients underwent plate removal, reasons for removal were pain (n = 21), nonunion (n = 5), and hardware failure (n = 2). Seven patients had cable-induced bone loss. Anatomic positioning of the plate (P = .03) and number of cables used (P = .03) were associated with radiographic union. Nonunion was associated with a higher incidence (+30%) of hardware failure due to broken cable(s) (P = .005). Conclusions: Greater trochanteric nonunion remains a problem in THA. Successful fixation using current-generation cable plate devices may be influenced by plate positioning and number of cables used. Plate removal may be required for pain or cable-induced bone loss.

11.
J Arthroplasty ; 37(6S): S139-S146, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35272897

RESUMO

BACKGROUND: Intraosseous (IO) infusion of medication is a novel technique for total knee arthroplasty (TKA) antibiotic prophylaxis. To decrease postoperative pain in TKA patients, we investigated addition of morphine to a standard IO antibiotic injection. METHODS: A double-blind, randomized controlled trial was performed on 48 (24 each) consecutive patients undergoing primary TKA. The control group received an IO injection of antibiotics as per the standard protocol. The experimental group received an IO antibiotic injection with 10 mg of morphine. Pain, nausea, and opioid use were assessed up to 14 days postoperatively. Morphine and interleukin-6 serum levels were obtained 10 hours postoperatively in a subgroup of 20 patients. RESULTS: The experimental group had lower Visual Analog Scale pain score at 1, 2, 3, and 5 hours postoperatively (P = .0032, P = .005, P = .020, P = .010). This trend continued for postoperative day 1, 2, 8, and 9 (40% reduction, P = .001; 49% reduction, P = .036; 38% reduction, P = .025; 33% reduction, P = .041). The experimental group had lower opioid consumption than the control group for the first 48 hours and second week postsurgery (P < .05). Knee Injury and Osteoarthritis Outcome Score for Joint Replacement scores for the experimental group showed significant improvement at 2 and 8 weeks postsurgery (P < .05). Serum morphine levels in the experimental group were significantly less than the control group 10 hours after IO injection (P = .049). CONCLUSION: IO morphine combined with a standard antibiotic solution demonstrates superior postoperative pain relief immediately and up to 2 weeks. IO morphine is a safe and effective method to lessen postoperative pain in TKA patients. LEVEL OF EVIDENCE: Therapeutic, Level 1.


Assuntos
Artroplastia do Joelho , Morfina , Analgésicos Opioides/uso terapêutico , Antibacterianos/uso terapêutico , Artroplastia do Joelho/efeitos adversos , Método Duplo-Cego , Humanos , Morfina/uso terapêutico , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/prevenção & controle
12.
J Arthroplasty ; 37(7S): S444-S448, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35227534

RESUMO

BACKGROUND: Hip abductor complex tears remain an injury without a clear consensus on management. Surgical treatment has been recommended after unsuccessful nonoperative management. This study evaluates both tenodesis and bone trough techniques, with treatment choices guided by previously described tear classification. METHODS: This is a retrospective cohort study of 45 hips in 44 patients who underwent surgical treatment for symptomatic, chronic hip abductor tear unresponsive to nonoperative treatment. Demographics and preoperative and postoperative values (including visual analog scale pain scores, gait assessment, and muscle strength) were evaluated. Type I tears were treated using tendon tenodesis. Type II tears were treated through a bone trough repair. RESULTS: Forty-five hips (44 patients) were operated on with a minimum of 6-month follow-up. There were 27 type I and 18 type II tears. Eighty-seven percent of patients were female. Twenty-eight percent of type II patients (5/18) had a preexisting arthroplasty in place. Significant improvements in pain (P < .001), gait (P < .001), and muscle strength (P < .001) were achieved in both the tear types. Type I repairs showed superior results to type II repairs. However, both showed significant improvements. Postoperative magnetic resonance imaging at 6 months showed healed tenodesis in 81% (17/21) of type I tears and 50% (5/10) of type II tears. CONCLUSION: Our study shows improvement in pain and function after surgical repair of hip abductor tendon injuries in both simple and complex tears. This improvement is seen even during ongoing surgical site healing. Magnetic resonance imaging findings may remain abnormal for more than 1 year after surgery and do not clearly denote repair failure.


Assuntos
Lesões do Quadril , Tenodese , Artrodese , Nádegas/cirurgia , Feminino , Lesões do Quadril/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Músculo Esquelético/cirurgia , Dor/cirurgia , Estudos Retrospectivos , Ruptura/cirurgia
13.
Bone Joint J ; 103-B(6 Supple A): 13-17, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34053300

RESUMO

AIMS: Infection complicating primary total knee arthroplasty (TKA) is a common reason for revision surgery, hospital readmission, patient morbidity, and mortality. Increasing incidence of methicillin-resistant Staphylococcus aureus (MRSA) is a particular concern. The use of vancomycin as prophylactic agent alone or in combination with cephalosporin has not demonstrated lower periprosthetic joint infection (PJI) rates, partly due to timing and dosing of intravenous (IV) vancomycin administration, which have proven important factors in effectiveness. This is a retrospective review of a consecutive series of primary TKAs examining incidence of PJI, adverse reactions, and complications using IV versus intraosseous (IO) vancomycin at 30-day, 90-day, and one-year follow-up. METHODS: A retrospective review of 1,060 patients who underwent TKA between May 2016 to July 2020 was performed. There were 572 patients in the IV group and 488 in the IO group, with minimal 30 days of follow-up. Patients were followed up at regularly scheduled intervals (two, six, and 12 weeks). No differences between groups for age, sex, BMI, or baseline comorbidities existed. The IV group received an IV dose of 15 mg/kg vancomycin given over an hour preceding skin incision. The IO group received a 500 mg dose of vancomycin mixed in 150 ml of normal saline, injected into proximal tibia after tourniquet inflation, before skin incision. All patients received an additional dose of first generation cephalosporin. Evaluation included preoperative and postoperative serum creatinine values, tourniquet time, and adverse reactions attributable to vancomycin. RESULTS: Incidence of PJI with minimum 90-day follow-up was 1.4% (eight knees) in the IV group and 0.22% (one knee) in IO group (p = 0.047). This preliminary report demonstrated an reduction in the incidence of infection in TKA using IO vancomycin combined with a first-generation cephalosporin. While the study suffers from limitations of a retrospective, multi-surgeon investigation, early findings are encouraging. CONCLUSION: IO delivery of vancomycin after tourniquet inflation is a safe and effective alternative to IV administration, eliminating the logistical challenges of timely dosing. Cite this article: Bone Joint J 2021;103-B(6 Supple A):13-17.


Assuntos
Antibacterianos/administração & dosagem , Antibioticoprofilaxia , Artroplastia do Joelho , Infecções Relacionadas à Prótese/prevenção & controle , Vancomicina/administração & dosagem , Idoso , Distinções e Prêmios , Feminino , Seguimentos , Humanos , Masculino , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos
14.
Clin Sports Med ; 40(2): 271-288, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33673886

RESUMO

Acetabular dysplasia represents a structural pathomorphology associated with hip pain, instability, and osteoarthritis. The wide spectrum of dysplasia anatomically refers to a 3-dimensional volumetric- and surface area-based insufficiency in coverage and is classified based on the magnitude and location of undercoverage. Borderline dysplasia has been variably defined and leads to management challenges. In symptomatic dysplasia, treatment addresses coverage with periacetabular osteotomy. Concomitant simultaneous or staged hip arthroscopy has significant advantages to address intra-articular pathology. In nonarthritic individuals, there is evidence PAO alters the natural history of dysplasia and decreases the risk of hip arthritis and total hip arthroplasty.


Assuntos
Luxação do Quadril/cirurgia , Acetábulo/cirurgia , Adulto , Artralgia , Artroscopia , Feminino , Humanos , Masculino , Osteotomia , Resultado do Tratamento
15.
JMIR Mhealth Uhealth ; 8(6): e19333, 2020 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-32589161

RESUMO

BACKGROUND: Despite the growth of and media hype about mobile health (mHealth), there is a paucity of literature supporting the effectiveness of widespread implementation of mHealth technologies. OBJECTIVE: This study aimed to assess whether an innovative mHealth technology system with several overlapping purposes can impact (1) clinical outcomes (ie, readmission rates, revisit rates, and length of stay) and (2) patient-centered care outcomes (ie, patient engagement, patient experience, and patient satisfaction). METHODS: We compared all patients (2059 patients) of participating orthopedic surgeons using mHealth technology with all patients of nonparticipating orthopedic surgeons (2554 patients). The analyses included Wilcoxon rank-sum tests, Kruskal-Wallis tests for continuous variables, and chi-square tests for categorical variables. Logistic regression models were performed on categorical outcomes and a gamma-distributed model for continuous variables. All models were adjusted for patient demographics and comorbidities. RESULTS: The inpatient readmission rates for the nonparticipating group when compared with the participating group were higher and demonstrated higher odds ratios (ORs) for 30-day inpatient readmissions (nonparticipating group 106/2636, 4.02% and participating group 54/2048, 2.64%; OR 1.48, 95% CI 1.03 to 2.13; P=.04), 60-day inpatient readmissions (nonparticipating group 194/2636, 7.36% and participating group 85/2048, 4.15%; OR 1.79, 95% CI 1.32 to 2.39; P<.001), and 90-day inpatient readmissions (nonparticipating group 261/2636, 9.90% and participating group 115/2048, 5.62%; OR 1.81, 95% CI 1.40 to 2.34; P<.001). The length of stay for the nonparticipating cohort was longer at 1.90 days, whereas the length of stay for the participating cohort was 1.50 days (mean 1.87, SD 2 vs mean 1.50, SD 1.37; P<.001). Patients treated by participating surgeons received and read text messages using mHealth 83% of the time and read emails 84% of the time. Patients responded to 60% of the text messages and 53% of the email surveys. Patients were least responsive to digital monitoring questions when the hospital asked them to do something, and they were most engaged with emails that did not require action, including informational content. A total of 96% (558/580) of patients indicated high satisfaction with using mHealth technology to support their care. Only 0.40% (75/2059) patients opted-out of the mHealth technology program after enrollment. CONCLUSIONS: A novel, multicomponent, pathway-driven, patient-facing mHealth technology can positively impact patient outcomes and patient-reported experiences. These technologies can empower patients to play a more active and meaningful role in improving their outcomes. There is a deep need, however, for a better understanding of the interactions between patients, technology, and health care providers. Future research is needed to (1) help identify, address, and improve technology usability and effectiveness; (2) understand patient and provider attributes that support adoption, uptake, and sustainability; and (3) understand the factors that contribute to barriers of technology adoption and how best to overcome them.


Assuntos
Telemedicina , Idoso , Tecnologia Biomédica , Feminino , Humanos , Masculino , Estudos Retrospectivos , Tecnologia
16.
J Hip Preserv Surg ; 7(1): 43-48, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32382428

RESUMO

Ischiofemoral impingement (IFI) is a cause of deep gluteal space syndrome. The prevalence of radiographic findings in patients with hip pain is unknown. To assess if there is a correlation between femoral neck-shaft angle (NSA) and the distance of the ischiofemoral space (IFS) and quadratus femoris space (QFS) and to determine the prevalence of quadratus femoris (QF) edema in patients with hip pain. A retrospective case series was conducted involving 100 consecutive hip or pelvis magnetic resonance imaging scans on patients presenting with hip pain. NSA, IFS and QFS distances were measured and presence of QF edema was noted. Analysis of the groups (QF edema vs no edema) was performed using two-tailed t-test and Pearson correlation. There were 18 hips in the edema group (mean age 51.11 years ± 10.5) and 82 hips in the non-edema group (mean age 40.79 years ± 15.9). Within the edema group, there was a moderate positive correlation between NSA and QFS (r = 0.498, P = 0.036) and a weak positive correlation between NSA and IFI (0.312, P = 0.208). The prevalence of QF edema in this study was 18% with only 28% of those subjects having clinical symptoms of IFI. Patients with QF edema had significantly narrower QFS and IFS distances (P < 0.001). The prevalence of QF edema is 18% in a consecutive sample of adults with hip pain. In patients with QF edema, only 28% have symptoms of IFI. In patients with QF edema, there was a moderate positive correlation between NSA and QFS.

17.
Bone Joint J ; 102-B(2): 191-197, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32009430

RESUMO

AIMS: Although good clinical outcomes have been reported for monolithic tapered, fluted, titanium stems (TFTS), early results showed high rates of subsidence. Advances in stem design may mitigate these concerns. This study reports on the use of a current monolithic TFTS for a variety of indications. METHODS: A multi-institutional retrospective study of all consecutive total hip arthroplasty (THA) and revision total hip arthroplasty (rTHA) patients who received the monolithic TFTS was conducted. Surgery was performed by eight fellowship-trained arthroplasty surgeons at four institutions. A total of 157 hips in 153 patients at a mean follow-up of 11.6 months (SD7.8) were included. Mean patient age at the time of surgery was 67.4 years (SD 13.3) and mean body mass index (BMI) was 28.9 kg/m2 (SD 6.5). Outcomes included intraoperative complications, one-year all-cause re-revisions, and subsidence at postoperative time intervals (two weeks, six weeks, six months, nine months, and one year). RESULTS: There were eight intraoperative complications (4.9%), six of which were intraoperative fractures; none occurred during stem insertion. Six hips (3.7%) underwent re-revision within one year; only one procedure involved removal of the prosthesis due to infection. Mean total subsidence at latest follow-up was 1.64 mm (SD 2.47). Overall, 17 of 144 stems (11.8%) on which measurements could be performed had >5 mm of subsidence, and 3/144 (2.1%) had >10 mm of subsidence within one year. A univariate regression analysis found that additional subsidence after three months was minimal. A multivariate regression analysis found that subsidence was not significantly associated with periprosthetic fracture as an indication for surgery, the presence of an extended trochanteric osteotomy (ETO), Paprosky classification of femoral bone loss, stem length, or type of procedure performed (i.e. full revision vs conversion/primary). CONCLUSION: Advances in implant design, improved trials, a range of stem lengths and diameters, and high offset options mitigate concerns of early subsidence and dislocation with monolithic TFTS, making them a valuable option for femoral revision. Cite this article: Bone Joint J 2020;102-B(2):191-197.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Materiais Biocompatíveis , Fêmur/fisiopatologia , Fêmur/cirurgia , Articulação do Quadril/fisiopatologia , Prótese de Quadril/efeitos adversos , Humanos , Pessoa de Meia-Idade , Osseointegração , Desenho de Prótese , Reoperação/instrumentação , Estudos Retrospectivos , Titânio , Resultado do Tratamento
19.
J Bone Joint Surg Am ; 101(23): 2082-2090, 2019 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-31800421

RESUMO

BACKGROUND: Comprehensive systematic reviews of results from homogenous or heterogeneous clinical trials, meta-analyses are used to summarize and to interpret studies. Proponents believe that their use can increase study power and improve precision results. Critics emphasize that heterogeneity between studies and bias of individual studies compromise the value of results. The methodology of meta-analyses has improved over time, utilizing statistical analysis to reduce bias and examining heterogeneity. With an increasing trend of meta-analyses in orthopaedic literature, this study aimed to investigate quality and clinical utility of meta-analyses for total knee arthroplasty and total hip arthroplasty. METHODS: A systematic review of total knee arthroplasty and total hip arthroplasty meta-analyses in 3 major orthopaedic journals from January 2000 to August 2017 was performed. Three authors independently reviewed eligible meta-analyses. A quality assessment was conducted using the Oxman-Guyatt Index. Reporting quality was assessed using PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses). Two high-volume, fellowship-trained, attending surgeons specializing in total hip arthroplasty and total knee arthroplasty independently, in a blinded fashion, reviewed 24 of the highest-scored meta-analyses. RESULTS: There were 114 studies meeting eligibility criteria, 25 published from 2000 to 2009 and 89 published from 2010 to 2017, a 3.6-fold increase. The mean Oxman-Guyatt Index score was 3.89 points, with 12 high-quality studies, 87 moderate-quality studies, and 15 low-quality studies. The mean PRISMA score for all meta-analyses was 22.2 points, with 79% classified as low to moderate. Only 23 studies listed the Level of Evidence, and 8 were Level-I studies and 9 were Level-II studies. Studies with >15 randomized controlled trials were associated with higher PRISMA and Oxman-Guyatt Index scores. In 12 articles, we were unable to decipher the types of studies included. Only 39.4% of studies showed the risk of bias. Of the 24 studies identified as high quality per the PRISMA statement, 71% were determined to be either clinically unimportant or inconclusive. CONCLUSIONS: The number of total hip arthroplasty and total knee arthroplasty meta-analyses has markedly increased over the past decades. The majority of published meta-analyses from 3 major orthopaedic journals were not performed in accordance with established PRISMA guidelines. CLINICAL RELEVANCE: Many published meta-analyses are low to moderate quality, and clinicians should cautiously draw conclusions from poorly executed meta-analyses.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Artroplastia do Joelho/estatística & dados numéricos , Cirurgiões Ortopédicos/estatística & dados numéricos , Melhoria de Qualidade , Artroplastia de Quadril/métodos , Artroplastia do Joelho/métodos , Feminino , Humanos , Masculino , Análise e Desempenho de Tarefas , Estados Unidos
20.
Artigo em Inglês | MEDLINE | ID: mdl-31875200

RESUMO

Patient-specific design (PSD) total knee arthroplasty implants are marketed to restore neutral mechanical-axis alignment (MAA) and provide better anatomic fit compared with standard off-the-shelf (OTS) total knee arthroplasty designs. The purpose was to compare the Knee Society scores, radiographic outcomes, and complications of PSD and OTS implants. METHODS: Retrospective study analyzing PSD and OTS by a single surgeon. Implant design change in PSD occurred during the period of data collection leading to PSD-1 and PSD-2 subgroups. Radiographic data including MAA, femorotibial angle, coronal-tibial angle, tibial slope and patella-sulcus angle, and complications were analyzed. Minimum follow-up was 2 years or until revision, and patients completed Knee Society scores preoperatively and postoperatively at 3, 6, 12, 24 weeks, and final follow-up. RESULTS: There were 136 patients (154 knees), average age (62.76 +/- 8.4 years), and follow-up (3.1 +/- 1.5 years). The groups included PSD-1 (77 knees), PSD-2 (36 knees), and OTS (41 knees). The PSD-2 group had better Knee Society function scores compared with PSD-1 and OTS at all timepoints except final follow-up. PSD-2 had significantly shorter hospital stay (P = 0.000012) and less hemoglobin drop (P = 0.032) compared with PSD-1 and OTS. No differences were observed in MAA (P = 0.349) or final range of motion (P = 0.629) between the 3 groups. PSD-2 had more normal femorotibial angle, coronal-tibial angle, and tibial slope compared with PSD-1 and OTS. Failures requiring revision were 23% (18/77) PSD-1, 0% PSD-2, and 3% (1/35) OTS. Most common modes of failure were tibial subsidence (56%) and polyethylene locking mechanism failure (22%) in PSD-1. CONCLUSION: Catastrophic failure was seen in the PSD-1 group with tibial subsidence and polyethylene locking mechanism failure. PSD-2 had better early Knee Society function scores, shorter hospital stay, lower hemoglobin drop, radiographic alignment, and no failures compared with PSD-1 and OTS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...