Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Talanta ; 179: 207-212, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29310223

RESUMO

Isolation of specific cells from whole blood is important to monitor disease prognosis and diagnosis. In this study, a vibration-assisted filtration (VF) device has been developed for isolation and recovery of specific cells such as leukocytes and pathogenic bacteria from human whole blood. The VF device is composed of three layers which was fabricated using injection molding with cyclic olefin copolymer (COC) pellets consisting of: a top layer with coin-type vibration motor (Ф = 10mm), a middle plate with a 1µm or 3µm-pore filter membrane to separate of Staphylococcus aureus (S. aureus) cells or leukocytes (i.e. white blood cells) respectively, and a bottom chamber with conical-shaped microstructure. One milliliter of human whole blood was injected into a sample loading chamber using a 3µm-pore filter equipped in the VF device and the coin-type vibration motor applied external vibration force by generating a rotational fluid which enhances the filtration velocity due to the prevention of the cell clogging on the filter membrane. The effluent blood such as erythrocytes, platelet, and plasma was collected at the bottom chamber while the leukocytes were sieved by the filter membrane. The vibration-assisted leukocyte separation was able to finish within 200s while leukocyte separation took 1200s without vibration. Moreover, we successfully separated S. aureus from human whole blood using a 1µm-pore filter equipped VF device and it was further confirmed by genetic analysis. The proposed VF device provides an advanced cell separation platform in terms of simplicity, fast separation, and portability in the fields of point-of-care diagnostics.


Assuntos
Separação Celular/instrumentação , Desenho de Equipamento , Filtração/métodos , Leucócitos/citologia , Staphylococcus aureus/isolamento & purificação , Plaquetas/citologia , Separação Celular/métodos , Eritrócitos/citologia , Filtração/instrumentação , Humanos , Leucócitos/fisiologia , Sistemas Automatizados de Assistência Junto ao Leito , Vibração
3.
Ultrason Sonochem ; 28: 178-184, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26384897

RESUMO

A sonochemical method has been employed for the synthesis of palladium oxide (PdO) nanoparticles deposited on silica nanoparticle. By sonochemical process, the PdO nanoparticles were doped on the surface of silica at room temperature and atmospheric pressure with short reaction time. Silica nanoparticles were used as a supporting material to suppress aggregation and thereby to increase surface area of PdO nanoparticles. Fabricated PdO-doped silica nanoparticle (PdO@SNP) was applied as a nanocatalyst for selective alcohol oxidation reaction in the presence of molecular oxygen. The PdO@SNP composite showed higher catalytic activity and selectivity than unsupported PdO nanoparticle for aerobic alcohol oxidation reaction.

4.
ACS Appl Mater Interfaces ; 7(32): 17904-9, 2015 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-26192469

RESUMO

A dye-doped polymer-dispersed liquid crystal (PDLC) is an attractive material for application in smart windows. Smart windows using a PDLC can be operated simply and have a high contrast ratio compared to those of other devices that employed photochromic or thermochromic material. However, in conventional dye-doped PDLC methods, dye contamination can cause problems and has a limited degree of commercialization of electric smart windows. Here, we report on an approach to resolve dye-related problems by encapsulating the dye in monodispersed capsules. By encapsulation, a fabricated dye-doped PDLC had a contrast ratio of >120 at 600 nm. This fabrication method of encapsulating the dye in a core-shell structured microcapsule in a dye-doped PDLC device provides a practical platform for dye-doped PDLC-based smart windows.

5.
Artigo em Inglês | MEDLINE | ID: mdl-25974673

RESUMO

In this work, (1)H NMR is utilized for the quantitative analysis of a specific cyclic dimer fatty acid in a dimer acid mixture using the pseudo-standard material of mesitylene on the basis of its structural similarity. Mesitylene and cyclic dimer acid levels were determined using the signal of the proton on the cyclic ring (δ=6.8) referenced to the signal of maleic acid (δ=6.2). The content of the cyclic dimer fatty acid was successfully determined through the standard curve of mesitylene and the reported equation. Using the linearity of the mesitylene curve, the cyclic dimer fatty acid in the oil mixture was quantified. The results suggest that the proposed method can be used to quantify cyclic compounds in mixtures to optimize the dimerization process.


Assuntos
Ácidos Graxos/química , Ciclização , Dimerização , Modelos Moleculares , Óleos de Plantas/química , Espectroscopia de Prótons por Ressonância Magnética
6.
Lab Chip ; 14(11): 1873-9, 2014 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-24706072

RESUMO

Single microbial cell encapsulation in hydrogels is an important task to find valuable biological resources for human welfare. The conventional microfluidic designs are mainly targeted only for highly dispersed spherical bioparticles. Advanced structures should be taken into consideration for handling such aggregated and non-spherical microorganisms. Here, to address the challenge, we propose a new type of cylindrical-shaped micropillar array in a microfluidic device for enhancing the dispersion of cell clusters and the isolation of individual cells into individual micro-hydrogels for potential practical applications. The incorporated micropillars act as a sieve for the breaking of Escherichia coli (E. coli) clusters into single cells in a polymer mixture. Furthermore, the combination of hydrodynamic forces and a flow-focusing technique will improve the probability of encapsulation of a single cell into each hydrogel with a broad range of cell concentrations. This proposed strategy and device would be a useful platform for genetically modified microorganisms for practical applications.


Assuntos
Escherichia coli/citologia , Hidrogéis/química , Técnicas Analíticas Microfluídicas , Análise Serial de Tecidos , Células Imobilizadas/citologia , Células Imobilizadas/metabolismo , Escherichia coli/genética , Escherichia coli/metabolismo , Humanos , Hidrodinâmica , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Análise Serial de Tecidos/instrumentação , Análise Serial de Tecidos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...