Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultrasonics ; 47(1-4): 130-7, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17980896

RESUMO

The large number of degrees of freedom in the design of piezoelectric transducers requires a theoretical model that is computationally efficient so that a large number of iterations can be performed in the design optimisation. The materials used are often lossy, and indeed loss can be used to enhance the operational characteristics of these designs. Motivated by these needs, this paper extends the one-dimensional linear systems model to incorporate frequency dependent elastic loss. The reception sensitivity, electrical impedance and electromechanical coupling coefficient of a 1-3 composite transducer, with frequency dependent loss in the polymer filler, are investigated. By plotting these operating characteristics as a function of the volume fraction of piezoelectric ceramic an optimum design is obtained. A device with a non-standard, high shear attenuation polymer is also simulated and this leads to an increase in the electromechanical coupling coefficient. A comparison with finite element simulations is then performed. This shows that the two methods are in reasonable agreement in their electrical impedance profiles in all the cases considered. The plots are almost identical away from the main resonant peak where the frequency location of the peaks are comparable but there is in some cases a 20% discrepancy in the magnitude of the peak value and in its bandwidth. The finite element model also shows that the use of a high shear attenuation polymer filler damps out the unwanted, low frequency modes whilst maintaining a reasonable impedance magnitude.


Assuntos
Eletroquímica/instrumentação , Modelos Teóricos , Transdutores , Ultrassonografia/instrumentação , Simulação por Computador , Elasticidade , Impedância Elétrica , Eletroquímica/métodos , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento , Manufaturas , Espalhamento de Radiação , Ultrassonografia/métodos
2.
Ultrasonics ; 47(1-4): 102-10, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17892890

RESUMO

This paper investigates the use of magnetically active materials in the matching layer of a piezoelectric transducer. This then allows the performance of the device to be dynamically altered by applying an external field. The effect that this new matching layer has on the performance of a typical device is theoretically investigated here. It transpires that the additional flexibility of an active matching layer can be used to maintain the efficiency of the device as the external load is varied.


Assuntos
Desenho Assistido por Computador , Eletroquímica/instrumentação , Membranas Artificiais , Modelos Teóricos , Transdutores , Ultrassonografia/instrumentação , Simulação por Computador , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Ultrassonografia/métodos
3.
Artigo em Inglês | MEDLINE | ID: mdl-16060502

RESUMO

The effect of temperature on the behavior of 1-3 piezoelectric composites manufactured using various polymeric materials was assessed experimentally through electrical impedance analysis and laser vibrometry. Device behavior varied with temperature irrespective of the polymer filler. Most significant changes in the piezoelectric composites were recorded around the glass transition temperature (Tg) of the polymer; movement to lower fundamental resonant frequencies and higher values of electrical impedance minima were observed at higher temperatures. Decoupling of the pillars from the polymer matrix was observed by laser vibrometry at high temperatures. The use of high Tg polymer extended the operational temperature range of a piezoelectric composite, and a high Tg polymer with improved thermal conductivity also proved beneficial. For all devices, at temperatures very close to room temperature, subtle changes in device performance, linked to polymer softening, were observed. Particulate filled materials have been investigated, and it is recognized that the high viscosities and low mechanical damping of such materials could be problematic for piezoelectric composite manufacture. The thermal solver of the PZFlex finite element code has been used to predict the temporal and spatial temperature response of a selection of the devices presented. The simulated and experimental data compare favorably.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...