Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Langenbecks Arch Surg ; 409(1): 69, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38376630

RESUMO

INTRODUCTION: Inside the operating room, experts use verbal instructions to guide surgical novices through laparoscopic procedures. In this study, we evaluated the use of a crosshair attached to the video monitor, as a hands-free pointing tool to simplify instructions during operation. METHODS: Ten surgical novices performed two elective laparoscopic cholecystectomies within a week of each other, randomized such that one was performed with and the other without using the crosshair. Directly after operation, questionnaires were completed by the novices and the consultant surgeons. Measures including the comprehensibility of instructions, subjective feeling of safety during preparation, time delays due to different instruction options, and disruptive influence while instructors used the crosshair. Differences in operative performance were evaluated based on the global operative assessment of laparoscopic skills (GOALS) scores. RESULTS: When the crosshair was used, surgical novices had a better understanding of which anatomical structure should be shown (p = 0.028). Operating time (p = 0.222) and feeling of confidence during preparation did not differ with versus without crosshair use (p = 0.081). All participants stated that the crosshair did not negatively affect the field of vision. In terms of the median GOALS score, the operative performance was improved when the crosshair was used compared with verbal instructions only (median 15, IQR (11; 21) vs. median 12, IQR (5; 19), p < 0.001). CONCLUSION: The crosshair is a simple, inexpensive, and widely available method to improve communication between instructors and novices in everyday training.


Assuntos
Colecistectomia Laparoscópica , Laparoscopia , Cirurgiões , Humanos , Salas Cirúrgicas
2.
Strahlenther Onkol ; 200(4): 314-319, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37947805

RESUMO

BACKGROUND: The first evaluation of radiotherapy results in patients with breast cancer treated as part of a multimodal oncologic therapy in the Nahe Breast Center is presented. Analysis of the results was performed using an in-practice registry. PATIENTS AND METHODS: From September 2016 to December 2017, 138 patients (median age 62.5 years; range 36-94 years) with breast cancer (right side, n = 67; left side, n = 71) received adjuvant radiation therapy. Of these, 103 patients received gyneco-oncologic care at the Nahe Breast Center, and 35 were referred from outside breast centers. The distribution into stages was as follows: stage I, n = 48; stage II, n = 68; stage III, n = 19; stage IV, n = 3. Neoadjuvant chemotherapy was given to 19 and adjuvant chemotherapy to 50 patients. Endocrine treatment was given to 120 patients. Both 3D conformal (n = 103) and intensity-modulated (n = 35) radiotherapy were performed with a modern linear accelerator. RESULTS: With a median follow-up of 60 months (1-67), local recurrence occurred in 4/138 (2.9%) and distant metastasis in 8/138 (5.8%) patients; 7/138 (5.1%) patients died of their tumors during the follow-up period. The actuarial 5­year local recurrence-free survival of all patients was 97.1%, and the actuarial 5­year overall survival of all patients was 94.9%. We observed no grade 3 or 4 radiogenic side effects. CONCLUSION: The results of radiotherapy for breast carcinoma at the Nahe Breast Center are comparable to published national and international results. In particular, the local recurrence rates in our study, determined absolutely and actuarially, are excellent, and demonstrate the usefulness of radiotherapy.


Assuntos
Neoplasias da Mama , Humanos , Pessoa de Meia-Idade , Feminino , Neoplasias da Mama/patologia , Estadiamento de Neoplasias , Seguimentos , Mama/patologia , Pesquisa sobre Serviços de Saúde , Recidiva Local de Neoplasia/patologia
3.
Integr Cancer Ther ; 20: 15347354211043199, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34581221

RESUMO

BACKGROUND: Increasingly, patients with cancer are asking for additional, complementary therapy options for treating the side effects of oncological therapy. Thus, the members of the Breast and Bowel Center Nahe at the Sankt Marienwörth Hospital Bad Kreuznach decided to define the content of this type of counseling for patients before treatment. METHODS: In 2018, a team of internal oncologists, gynecological oncologists, radio-oncologists, nutritionists, psycho-oncologists, and study nurses met several times to define the content of counseling. To inform the team, an intensive literature review was conducted. RESULTS: Counseling content was determined for complementary treatment options for the most frequent side effects of oncological therapies. Counseling sessions were formulated as frontal lectures (slide presentations), given at regular intervals for patients and relatives. These lectures were highly appreciated by patients. CONCLUSION: These counseling sessions increased patient understanding of both useful complementary measures and harmful measures they should not use.


Assuntos
Terapias Complementares , Oncologistas , Aconselhamento , Hospitais , Humanos , Oncologia
4.
Langenbecks Arch Surg ; 406(3): 911-915, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33710462

RESUMO

PURPOSE: Three-dimensional (3D) surgical planning is widely accepted in liver surgery. Currently, the 3D reconstructions are usually presented as 3D PDF data on regular monitors. 3D-printed liver models are sometimes used for education and planning. METHODS: We developed an immersive virtual reality (VR) application that enables the presentation of preoperative 3D models. The 3D reconstructions are exported as STL files and easily imported into the application, which creates the virtual model automatically. The presentation is possible in "OpenVR"-ready VR headsets. To interact with the 3D liver model, VR controllers are used. Scaling is possible, as well as changing the opacity from invisible over transparent to fully opaque. In addition, the surgeon can draw potential resection lines on the surface of the liver. All these functions can be used in a single or multi-user mode. RESULTS: Five highly experienced HPB surgeons of our department evaluated the VR application after using it for the very first time and considered it helpful according to the "System Usability Scale" (SUS) with a score of 76.6%. Especially with the subitem "necessary learning effort," it was shown that the application is easy to use. CONCLUSION: We introduce an immersive, interactive presentation of medical volume data for preoperative 3D liver surgery planning. The application is easy to use and may have advantages over 3D PDF and 3D print in preoperative liver surgery planning. Prospective trials are needed to evaluate the optimal presentation mode of 3D liver models.


Assuntos
Cirurgiões , Realidade Virtual , Humanos , Imageamento Tridimensional , Fígado/diagnóstico por imagem , Fígado/cirurgia , Estudos Prospectivos , Fluxo de Trabalho
5.
Int J Comput Assist Radiol Surg ; 16(1): 161-168, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33095424

RESUMO

PURPOSE: In laparoscopic surgery training, experts guide novice physicians to desired instrument positions or indicate relevant areas of interest. These instructions are usually given via verbal communication or using physical pointing devices. To facilitate a sterile work flow and to improve training, new guiding methods are needed. This work proposes to use optical see-through augmented reality to visualize an interactive virtual pointer on the laparoscopic. METHODS: After an interdisciplinary development, the pointer's applicability and feasibility for training was evaluated and it was compared to a standard condition based on verbal and gestural communication only. In this study, ten surgical trainees were guided by an experienced trainer during cholecystectomies on a laparoscopic training simulator. All trainees completed a virtual cholecystectomy with and without the interactive virtual pointer in alternating order. Measures included procedure time, economy of movement and error rates. RESULTS: Results of standardized variables revealed significantly improved economy of movement (p = 0.047) and error rates (p = 0.047), as well as an overall improved user performance (Total z-score; p = 0.031) in conditions using the proposed method. CONCLUSION: The proposed HoloPointer is a feasible and applicable tool for laparoscopic surgery training. It improved objective performance metrics without prolongation of the task completion time in this pre-clinical setup.


Assuntos
Realidade Aumentada , Instrução por Computador , Laparoscopia/educação , Treinamento por Simulação , Interface Usuário-Computador , Competência Clínica , Simulação por Computador , Humanos , Laparoscopia/métodos
6.
Dis Esophagus ; 33(11)2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-32476009

RESUMO

Laparoscopic fundoplication is considered the gold standard surgical procedure for the treatment of symptomatic hiatus hernia. Studies on surgical performance in minimally invasive hiatus hernia repair have neglected the role of the camera assistant so far. The current study was designed to assess the applicability of the structured assessment of laparoscopic assistance skills (SALAS) score to laparoscopic fundoplication as an advanced and commonly performed laparoscopic upper GI procedure. Randomly selected laparoscopic fundoplications (n = 20) at a single institute were evaluated. Four trained reviewers independently assigned SALAS scoring based on synchronized video and voice recordings. The SALAS score (5-25 points) consists of five key aspects of laparoscopic camera navigation as previously described. Experience in camera assistance was defined as at least 100 assistances in complex laparoscopic procedures. Nine different surgical teams, consisting of five surgical residents, three fellows, and two attending physicians, were included. Experienced and inexperienced camera assistants were equally distributed (10/10). Construct validity was proven with a significant discrimination between experienced and inexperienced camera assistants for all reviewers (P < 0.05). The intraclass correlation coefficient of 0.897 demonstrates the score's low interrater variability. The total operation time decreases with increasing SALAS score, not reaching statistical significance. The applied SALAS score proves effective by discriminating between experienced and inexperienced camera assistants in an upper GI surgical procedure. This study demonstrates the applicability of the SALAS score to a more advanced laparoscopic procedure such as fundoplication enabling future investigations on the influence of camera navigation on surgical performance and operative outcome.


Assuntos
Esofagoplastia , Hérnia Hiatal , Laparoscopia , Fundoplicatura , Hérnia Hiatal/cirurgia , Humanos , Duração da Cirurgia
7.
Langenbecks Arch Surg ; 405(2): 173-179, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32215728

RESUMO

PURPOSE: In hepatobiliary surgery, preoperative three-dimensional reconstruction based on CT or MRI can be provided externally or by local, semi-automatic software. We analyzed the time expense and quality of external versus local three-dimensional reconstructions. METHODS: Three first-year residents reconstructed data from 20 patients with liver pathologies using a local, semi-automatic, server-based program. Initially, five randomly selected patient datasets were segmented, with the visualization of an established external company available for comparison at all times (learning phase). The other fifteen cases were compared with the external datasets after completing local reconstruction (control phase). Total time expense/case and for specific manual and semi-automated reconstruction steps were recorded. Segmentation quality was analyzed by testing the equivalence for liver and tumor volumes, portal vein sectors, and hepatic vein territories. RESULTS: The median total reconstruction time was reduced from 2.5 h (learning phase) to 1.5 h (control phase) (- 42%; p < 0.001). Comparing the total and detailed liver volumes (sectors and territories) as well as the tumor volumes in the control phase equivalence was proven. In addition, a highly significant correlation between the external and local analysis was obtained over all analyzed segments with a very high ICC (median [IQR]: 0.98 [0.97; 0.99]; p < 0.01). CONCLUSION: Local, semi-automatic reconstruction performed by inexperienced residents was feasible with an expert level time expense and the quality of the three-dimensional images was comparable with those from an external provider.


Assuntos
Imageamento Tridimensional , Neoplasias Hepáticas/diagnóstico por imagem , Adulto , Idoso , Feminino , Hepatectomia , Veias Hepáticas/diagnóstico por imagem , Humanos , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Veia Porta/diagnóstico por imagem , Fatores de Tempo , Tomografia Computadorizada por Raios X , Adulto Jovem
8.
Pathologe ; 41(1): 70-72, 2020 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-31938820

RESUMO

A 37-year-old patient presented with B symptoms. On examination, hypodense liver lesions, multiple enlarged and partly confluent lymph nodes in the upper abdomen and retroperitoneum, as well as disseminated splenic and pulmonary foci were detected. Biopsies of a tumor in the coecum and the liver led to the diagnosis of an adenocarcinoma of the colon. In molecular pathology, microsatellite instability was detected. The post-neoadjuvant surgical specimen showed an unusual morphology and the question arose whether a second tumor should be considered.


Assuntos
Adenocarcinoma/diagnóstico , Neoplasias do Colo/diagnóstico , Neoplasias Hepáticas/diagnóstico , Segunda Neoplasia Primária/diagnóstico , Adenocarcinoma/genética , Adulto , Neoplasias do Colo/genética , Humanos , Neoplasias Hepáticas/genética , Instabilidade de Microssatélites , Terapia Neoadjuvante , Segunda Neoplasia Primária/genética
9.
J Minim Access Surg ; 16(4): 355-359, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31793451

RESUMO

INTRODUCTION: To objectively assess the quality of laparoscopic camera navigation (LCN), the structured assessment of LCN skills (SALAS) score was developed and validated for laparoscopic cholecystectomy. The aim of this pre-clinical study was to investigate the influence of LCN on surgical performance during virtual cholecystectomy (vCHE) using this score. METHODS: A total of 84 medical students were included in this prospective study. Individual characteristics were assessed with questionnaires. Participants completed a structured 2-day training course on a validated virtual reality laparoscopic simulator. At the end of the course, all students took over LCN during vCHE, all performed by the same surgeon. The numbers of errors regarding centering, horizon adjustment and instrument visualisation as well as manual and verbal corrections by the surgeon were recorded to calculate the SALAS score (range 5-25) to investigate the influence of LCN on surgical performance. The study population was divided by the recorded SALAS score into low and medium performers (Group A; 1st-3rd quartile; n = 60) and high performers (Group B, 4th quartile, n = 21). RESULTS: The SALAS score of the camera assistant correlates positively with the surgeon's overall performance in vCHE (P < 0.001), and the surgeon's virtual laparoscopic performance was significantly better in Group B (P < 0.001). Moreover, a significantly shorter operation time during vCHE was shown for Group B (Median (IQR); Group A: 508 s [429 s; 601 s]; Group B: 422 s [365 s; 493 s]; P = 0.001). Frequent gaming and a higher self-confidence to assist during a basic laparoscopic procedure were associated with a higher SALAS score (P = 0.013). CONCLUSION: In this pre-clinical setting, the surgeon's virtual performance is significantly influenced by the LCN quality. LCN by high performers resulted in a shorter operation time and a lower error rate.

10.
Dis Colon Rectum ; 62(2): 258-261, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30640838

RESUMO

INTRODUCTION: Head-mounted mixed-reality technologies may enable advanced intraoperative visualization during visceral surgery. In this technical note, we describe an innovative use of real-time mixed reality during robotic-assisted transanal total mesorectal excision. TECHNIQUE: Video signals from the robotic console and video endoscopic transanal approach were displayed on a virtual monitor using a head-up display. The surgeon, assistant, and a surgical trainee used this technique during abdominal and transanal robotic-assisted total mesorectal excision. We evaluated the feasibility and usability of this approach with the use of validated scales. RESULTS: The technical feasibility of the real-time visualization provided by the current setup was demonstrated for both the robotic and transanal parts of the surgery. The surgeon, assistant, and trainee each used the mixed-reality device for 15, 55, and 35 minutes. All participants handled the device intuitively and reported a high level of comfort during the surgery. The task load was easily manageable (task load index: <4/21), although the surgeon and assistant both noted a short delay in the real-time video. CONCLUSION: The implementation of head-mounted mixed-reality technology during robotic-assisted transanal total mesorectal excision can benefit the operating surgeon, assistant, and surgical trainee. Further improvements in display quality, connectivity, and systems integration are necessary.


Assuntos
Adenocarcinoma/cirurgia , Mesentério/cirurgia , Protectomia/métodos , Neoplasias Retais/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Realidade Virtual , Idoso , Humanos , Masculino , Cirurgia Endoscópica Transanal
11.
World J Surg ; 43(4): 1105-1116, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30523392

RESUMO

BACKGROUND: Although after R0 resection of intrahepatic cholangiocarcinoma (ICC) recurrence is frequent, most guidelines do not address strategies for this. The aim of this study was to analyze the outcome of repeated resection and to determine criteria when repeated resection is reasonable. METHODS: Between 2008 and 2016, we consecutively collected all cases of ICC (n = 176) in a prospective database and further analyzed them with a focus on tumor recurrence, its surgical treatment, overall survival and recurrence-free survival. RESULTS: Overall, a total of 22 explorations were performed for recurrent ICC in 17 patients. Resection rate was 18 repeated resections in 13 patients. Three patients underwent repeated resection twice and one patient three times. Recurrence was solitary in 7 patients and multifocal in 11 re-resected cases. Median overall survival (OS) of patients who underwent repeated resection was 65.2 months (interquartile range 37-126.5) with a 5-year OS rate of 62%, calculated from primary resection. Patients who underwent repeated resections had a significant better OS compared to those receiving chemotherapy, transarterial chemoembolization, selective internal radiotherapy, radiofrequency ablation or best supportive care (p < 0.001). CONCLUSION: Repeated resection of recurrent ICC is reasonable and associated with an improved survival. Re-exploration should be considered as long as resection is technically possible.


Assuntos
Neoplasias dos Ductos Biliares/cirurgia , Ductos Biliares Intra-Hepáticos/cirurgia , Colangiocarcinoma/cirurgia , Recidiva Local de Neoplasia/cirurgia , Idoso , Antineoplásicos/uso terapêutico , Neoplasias dos Ductos Biliares/patologia , Ductos Biliares Intra-Hepáticos/patologia , Ablação por Cateter , Quimioembolização Terapêutica , Colangiocarcinoma/patologia , Feminino , Hepatectomia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Estudos Prospectivos , Taxa de Sobrevida
12.
Surg Innov ; 25(3): 280-285, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29504470

RESUMO

INTRODUCTION: Immersive virtual reality (VR) laparoscopy simulation connects VR simulation with head-mounted displays to increase presence during VR training. The goal of the present study was the comparison of 2 different surroundings according to performance and users' preference. METHODS: With a custom immersive virtual reality laparoscopy simulator, an artificially created VR operating room (AVR) and a highly immersive VR operating room (IVR) were compared. Participants (n = 30) performed 3 tasks (peg transfer, fine dissection, and cholecystectomy) in AVR and IVR in a crossover study design. RESULTS: No overall difference in virtual laparoscopic performance was obtained when comparing results from AVR with IVR. Most participants preferred the IVR surrounding (n = 24). Experienced participants (n = 10) performed significantly better than novices (n = 10) in all tasks regardless of the surrounding ( P < .05). Participants with limited experience (n = 10) showed differing results. Presence, immersion, and exhilaration were significantly higher in IVR. Two thirds assumed that IVR would have a positive influence on their laparoscopic simulator use. CONCLUSION: This first study comparing AVR and IVR did not reveal differences in virtual laparoscopic performance. IVR is considered the more realistic surrounding and is therefore preferred by the participants.


Assuntos
Educação Médica/métodos , Laparoscopia/educação , Cirurgiões/educação , Realidade Virtual , Adulto , Competência Clínica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Adulto Jovem
13.
Int J Comput Assist Radiol Surg ; 13(2): 281-290, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29151194

RESUMO

PURPOSE: Virtual reality (VR) applications with head-mounted displays (HMDs) have had an impact on information and multimedia technologies. The current work aimed to describe the process of developing a highly immersive VR simulation for laparoscopic surgery. METHODS: We combined a VR laparoscopy simulator (LapSim) and a VR-HMD to create a user-friendly VR simulation scenario. Continuous clinical feedback was an essential aspect of the development process. We created an artificial VR (AVR) scenario by integrating the simulator video output with VR game components of figures and equipment in an operating room. We also created a highly immersive VR surrounding (IVR) by integrating the simulator video output with a [Formula: see text] video of a standard laparoscopy scenario in the department's operating room. RESULTS: Clinical feedback led to optimization of the visualization, synchronization, and resolution of the virtual operating rooms (in both the IVR and the AVR). Preliminary testing results revealed that individuals experienced a high degree of exhilaration and presence, with rare events of motion sickness. The technical performance showed no significant difference compared to that achieved with the standard LapSim. CONCLUSION: Our results provided a proof of concept for the technical feasibility of an custom highly immersive VR-HMD setup. Future technical research is needed to improve the visualization, immersion, and capability of interacting within the virtual scenario.


Assuntos
Simulação por Computador , Laparoscopia/educação , Laparoscopia/métodos , Cirurgiões , Realidade Virtual , Competência Clínica , Computadores , Retroalimentação , Feminino , Humanos , Laparoscópios , Masculino , Modelos Teóricos , Salas Cirúrgicas , Processamento de Sinais Assistido por Computador , Interface Usuário-Computador , Jogos de Vídeo , Gravação em Vídeo
14.
Surg Endosc ; 31(11): 4472-4477, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28378077

RESUMO

INTRODUCTION: Virtual reality (VR) and head mount displays (HMDs) have been advanced for multimedia and information technologies but have scarcely been used in surgical training. Motion sickness and individual psychological changes have been associated with VR. The goal was to observe first experiences and performance scores using a new combined highly immersive virtual reality (IVR) laparoscopy setup. METHODS: During the study, 10 members of the surgical department performed three tasks (fine dissection, peg transfer, and cholecystectomy) on a VR simulator. We then combined a VR HMD with the VR laparoscopic simulator and displayed the simulation on a 360° video of a laparoscopic operation to create an IVR laparoscopic simulation. The tasks were then repeated. Validated questionnaires on immersion and motion sickness were used for the study. RESULTS: Participants' times for fine dissection were significantly longer during the IVR session (regular: 86.51 s [62.57 s; 119.62 s] vs. IVR: 112.35 s [82.08 s; 179.40 s]; p = 0.022). The cholecystectomy task had higher error rates during IVR. Motion sickness did not occur at any time for any participant. Participants experienced a high level of exhilaration, rarely thought about others in the room, and had a high impression of presence in the generated IVR world. CONCLUSION: This is the first clinical and technical feasibility study using the full IVR laparoscopy setup combined with the latest laparoscopic simulator in a 360° surrounding. Participants were exhilarated by the high level of immersion. The setup enables a completely new generation of surgical training.


Assuntos
Pessoal de Saúde/educação , Laparoscopia/educação , Treinamento por Simulação/métodos , Realidade Virtual , Competência Clínica/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Humanos , Laparoscopia/métodos , Masculino , Inquéritos e Questionários
15.
J Surg Case Rep ; 2015(7)2015 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-26169531

RESUMO

Primary intestinal lymphangiectasia (PIL) is a rare disorder, especially in adults. It causes a local disruption of chylus transport and is part of the exudative gastroenteropathies. Conservative therapy includes dietary measures or somatostatin medication. Taking the differential diagnosis of PIL into consideration is a major challenge, since patients suffering from PIL may present with diarrhoea and lymphedema or chylous ascites. This can be explained by the chronic lymphedema of the bowel leading to dilation of the vessels (intraluminal loss) and sometimes even to a rupture (peritoneal loss). Push-pull enteroscopy and capsule endoscopy are the proper interventional diagnostic tools to discover PIL. Exploratory laparoscopy may be useful in unclear cases. Surgical resection of the altered intestine has been described with positive results. Exploratory laparoscopy may even be a diagnostic tool in unclear cases. Resection of the altered intestine is a treatment option in symptomatic and treatment-refractory cases.

16.
Surg Endosc ; 27(6): 2169-77, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23355149

RESUMO

BACKGROUND: Frequently medical students have to fulfill the role as the camera operator in laparoscopic procedures. Published work concerning camera navigation skills, especially in medical students, is rare. Therefore, our purpose was to evaluate personal characteristics and abilities that may affect virtual-reality laparoscopic camera navigation (VR-LCN) performance in a large cohort of first-time virtual-reality laparoscopy users. METHODS: First-time virtual-reality laparoscopy users (n = 488) were enrolled prospectively. The tasks included VR-LCN using a 0° and 30° angled laparoscope separately. Scores were correlated with demographics and students' self-assessment in univariate and multivariate analyses. RESULTS: Six variables were associated with better VR-LCN results in the univariate analysis. On multivariate analysis, only male gender (odds ratio 2.3, 95 % confidence interval 1.4-3.9; p = 0.002) and higher self-confidence to assist in a laparoscopic operation (odds ratio 1.7, 95 % confidence interval 1.1-2.6; p = 0.014) were identified as predictive factors for a better 30° angled VR-LCN performance. CONCLUSIONS: Our study indicates that medical students' self-confidence regarding their ability to navigate a camera in a laparoscopic procedure and male gender predict a better first-time VR-LCN performance. These findings may provide a basis for a tailored educational approach.


Assuntos
Educação de Graduação em Medicina/métodos , Laparoscopia/educação , Interface Usuário-Computador , Adulto , Competência Clínica/normas , Desenho de Equipamento , Feminino , Humanos , Laparoscopia/instrumentação , Masculino , Estudos Prospectivos , Desempenho Psicomotor , Autoimagem , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...