Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Lab Med ; 2(5): 725-736, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33636867

RESUMO

BACKGROUND: Monitoring infliximab (IFX) concentrations and the presence of antidrug antibodies (ADA) is important for patient management. We developed a method to measure IFX and ADA in serum in a single injection using surface plasmon resonance (SPR). METHODS: Using the Bio-Rad ProteOn XPR36, tumor necrosis factor-α and IFX were covalently immobilized onto separate lanes of a chip surface. Diluted serum was injected over both lanes, followed by an injection of goat antihuman antibody. The binding response was used to quantify IFX or detect ADA. The analytical performance of the assay was determined. Using 50 patient samples, SPR results were compared with results from a reporter gene assay (RGA). RESULTS: For the quantification of IFX, the functional sensitivity was 0.5 µg/mL. The total precision was <10% for all concentrations tested. IFX concentrations measured by SPR correlated well with RGA (R = 0.862), but a bias was observed (slope = 0.61). SPR detected 14 ADA-positive samples. Compared with RGA for ADA detection, there were 6 true-positive, 8 false-positive, 5 false-negative, and 31 true-negative findings. CONCLUSION: SPR can be used to measure biological drug concentrations and detect ADA in serum. This technique may provide complementary information to current methods used to detect ADA.

3.
J Mol Diagn ; 12(3): 368-76, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20228266

RESUMO

High-resolution melting analysis was applied to X-linked chronic granulomatous disease, a rare disorder resulting from mutations in CYBB. Melting curves of the 13 PCR products bracketing CYBB exons were predicted by Poland's algorithm and compared with observed curves from 96 normal individuals. Primer plates were prepared robotically in batches and dried, greatly simplifying the 3- to 6-hour workflow that included DNA isolation, PCR, melting, and cycle sequencing of any positive products. Small point mutations or insertions/deletions were detected by mixing the hemizygous male DNA with normal male DNA to produce artificial heterozygotes, whereas detection of gross deletions was performed on unmixed samples. Eighteen validation samples and 22 clinical kindreds were analyzed for CYBB mutations. All blinded validation samples were correctly identified. The clinical probands were identified after screening for neutrophil oxidase activity. Nineteen different mutations were found, including seven near intron-exon boundaries predicting splicing defects, five substitutions within exons, three small deletions predicting premature termination, and four gross deletions of multiple exons. Ten novel mutations were found, including (c.) two missense (730T>A, 134T>G), one nonsense (90C>A), four splice site defects (45 + 1G>T, 674 + 4A>G, 1461 + 2delT, and 1462-2A>C), two small deletions (636delT, 1661_1662delCT), and one gross deletion of exons 6 to 8. High-resolution melting can provide timely diagnosis at low cost for effective clinical management of rare, genetic primary immunodeficiency disorders.


Assuntos
Genes Ligados ao Cromossomo X/genética , Doença Granulomatosa Crônica/genética , Reação em Cadeia da Polimerase/métodos , Feminino , Humanos , Masculino , Glicoproteínas de Membrana/genética , NADPH Oxidase 2 , NADPH Oxidases/genética , Análise de Sequência de DNA
4.
Pediatr Infect Dis J ; 28(6): 529-33, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19483518

RESUMO

Chronic granulomatous disease (CGD) is a rare inherited immunodeficiency disorder. The clinical presentation is varied depending on the degree of involvement of the NADPH oxidase system responsible for the oxidative burst of neutrophils. We present 3 cases of variant X-linked CGD in an effort to introduce the disease and highlight the importance and limitations of CGD screening. The variant X-linked form of CGD results in a less severe phenotype and frequently presents later in life. Variant X-linked CGD is difficult to diagnose, but is becoming more readily recognized based on improved testing methods. A high index of suspicion in the setting of unusual infections such as Burkholderia cepacia pneumonia is essential to make the diagnosis. Family screening can lead to early intervention, prophylaxis, and appropriate genetic counseling.


Assuntos
Doença Granulomatosa Crônica , Adolescente , Adulto , Líquido da Lavagem Broncoalveolar/microbiologia , Infecções por Burkholderia/microbiologia , Burkholderia cepacia/isolamento & purificação , Criança , Pré-Escolar , Família , Feminino , Triagem de Portadores Genéticos , Variação Genética , Doença Granulomatosa Crônica/diagnóstico , Doença Granulomatosa Crônica/genética , Humanos , Masculino , Glicoproteínas de Membrana/genética , NADPH Oxidase 2 , NADPH Oxidases/genética , Neutrófilos/metabolismo , Linhagem , Rodaminas/metabolismo
6.
J Clin Lab Anal ; 21(5): 265-70, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17847108

RESUMO

Lymphocyte proliferation in response to mitogens, phytohemagglutinin (PHA), concanavalin A, pokeweed, and/or specific antigens has been the method of choice for in vitro diagnosis of cell-mediated immune dysfunction. Recently, an assay to measure intracellular adenosine triphosphate (ATP) production in response to PHA has been developed that requires a shorter, overnight incubation. We compared a standard 5- to 7-day lymphocyte mitogen stimulation assay utilizing tritiated thymidine (3H-thy) incorporation to one in which ATP production in response to PHA by CD4-positive cells is measured in a luminometer that requires only 18-24 hr. A total of 20 patient samples suspected of having decreased cell-mediated immunity submitted for mitogen induced lymphocyte proliferation and 21 normal controls were tested in both assays. A comparison of these two methods has demonstrated that the screening ATP assay has a sensitivity at 24 hr of 100% in detecting decreased PHA induced lymphocyte proliferation at 5 days and a specificity of 85% in the samples obtained from normal controls. The data indicate that the ATP assay may be a useful screening tool for more rapid detection of blood samples with decreased cell-mediated immune responses. However, a positive screen should always be confirmed by 3H-thy uptake using mitogens and recall antigens like candida and tetanus.


Assuntos
Trifosfato de Adenosina/sangue , Síndromes de Imunodeficiência/diagnóstico , Ativação Linfocitária , Mitógenos/farmacologia , Fito-Hemaglutininas/farmacologia , Adolescente , Adulto , Proliferação de Células/efeitos dos fármacos , Criança , Pré-Escolar , Feminino , Humanos , Imunidade Celular/fisiologia , Síndromes de Imunodeficiência/imunologia , Testes Imunológicos/métodos , Lactente , Ativação Linfocitária/efeitos dos fármacos , Linfócitos/citologia , Linfócitos/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
7.
Clin Diagn Lab Immunol ; 11(2): 325-9, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15013983

RESUMO

While modern immunoassays provide sensitive and specific means for the quantitation of cytokines in biological fluids, heterophile antibodies are still a well-recognized cause of interference in the measurement of cytokines in these assays. We have developed a multiplexed fluorescent microsphere immunoassay for the simultaneous quantification of 10 cytokines in only 75 microl of serum. During the development of this multiplexed assay, the amount of assay interference due to heterophile antibodies was also determined, and methods for detecting heterophile interference and minimizing its effect were incorporated into the assay. Heterophile antibodies resulted in significantly elevated cytokine values compared to those of normal blood bank samples. These falsely elevated values, and thus the components of the assay the heterophile antibodies were binding to, were identified through the use of internal controls. This information was then used to design assay-specific blockers and absorbents that were shown to significantly reduce falsely elevated cytokine values while not affecting the standard and control values. The fluorescent multiplexed microsphere-based immunoassay can be used to quantitate multiple cytokines from a single sample and should be a useful tool in furthering our understanding of the role of cytokines in disease processes.


Assuntos
Anticorpos Heterófilos , Citocinas/análise , Citocinas/imunologia , Imunoensaio/métodos , Reações Falso-Positivas , Humanos , Microscopia de Fluorescência , Microesferas , Sensibilidade e Especificidade
8.
Am J Clin Pathol ; 118(3): 346-53, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12219776

RESUMO

We used a multiplexedfluorescent microsphere immunoassay to develop a sandwich capture assay to assess simultaneously the production of thymus helper (TH) 1- and TH2-type cytokines in tissue culture supernatant obtained from stimulated peripheral blood mononuclear cells. The assay then was used to assess the cytokine production of patients with hyperimmunoglobulinemia E syndrome and in cord blood from neonates. The multiplexed assay has a reportable range of less than 10 to 50,000 pg/mL. For linearity and recovery studies, R2 values for the 6 cytokines ranged from 0.988 to 0.999 for samples spiked with known concentrations of recombinant cytokine standards and for patient samples. The assay showed good specificity, with little cross-reactivity between cytokines. Results from supernatants of Staphylococcus aureus-stimulated peripheral blood mononuclear cells obtainedfrom 6 patients with hyperimmunoglobulinemia E syndrome showed significantly less interferon (IFN)-gamma production than cells from healthy control subjects. Cord blood cells from neonates produced significantly less interleukin 12 and IFN-gamma than cells from adults in group B streptococci-stimulated mononuclear cells. The fluorescent multiplexed microsphere immunoassay can be used to quantitate multiple cytokines from 1 sample and should be useful for further understanding of the cytokine role in disease.


Assuntos
Citocinas/biossíntese , Imunoensaio/métodos , Síndromes de Imunodeficiência/imunologia , Células Th1/imunologia , Células Th2/imunologia , Células Cultivadas , Sangue Fetal/imunologia , Fluorescência , Humanos , Hipergamaglobulinemia/imunologia , Imunoensaio/instrumentação , Imunoglobulina E , Recém-Nascido , Leucócitos Mononucleares/imunologia , Ativação Linfocitária/fisiologia , Microesferas , Sensibilidade e Especificidade , Staphylococcus aureus/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...