Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(1)2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36617138

RESUMO

Time-of-flight cameras are widely adopted in a variety of indoor applications ranging from industrial object measurement to human activity recognition. However, the available products may differ in terms of the quality of the acquired point cloud, and the datasheet provided by the constructors may not be enough to guide researchers in the choice of the perfect device for their application. Hence, this work details the experimental procedure to assess time-of-flight cameras' error sources that should be considered when designing an application involving time-of-flight technology, such as the bias correction and the temperature influence on the point cloud stability. This is the first step towards a standardization of the metrological characterization procedure that could ensure the robustness and comparability of the results among tests and different devices. The procedure was conducted on Kinect Azure, Basler Blaze 101, and Basler ToF 640 cameras. Moreover, we compared the devices in the task of 3D reconstruction following a procedure involving the measure of both an object and a human upper-body-shaped mannequin. The experiment highlighted that, despite the results of the previously conducted metrological characterization, some devices showed evident difficulties in reconstructing the target objects. Thus, we proved that performing a rigorous evaluation procedure similar to the one proposed in this paper is always necessary when choosing the right device.


Assuntos
Corpo Humano , Humanos
2.
Artigo em Inglês | MEDLINE | ID: mdl-34574646

RESUMO

In recent years, the necessity to prevent work-related diseases has led to the use of sensor-based systems to measure important features during working activities. This topic achieved great popularity especially in hazardous and demanding activities such as those required of firefighters. Among feasible sensor systems, wearable sensors revealed their advantages in terms of possibility to conduct measures in real conditions and without influencing the movements of workers. In addition, the advent of robotics can be also exploited in order to reduce work-related disorders. The present literature review aims at providing an overview of sensor-based systems used to monitor physiological and physical parameters in firefighters during real activities, as well as to offer ideas for understanding the potentialities of exoskeletons and assistive devices.


Assuntos
Exoesqueleto Energizado , Bombeiros , Robótica , Humanos , Monitorização Fisiológica , Movimento
3.
Front Neurol ; 12: 700472, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34295303

RESUMO

Background: Crutches are the most common walking aids prescribed to improve mobility in subjects with central nervous system (CNS) lesions. To increase adherence to the appropriate level of crutch usage, providing load-related auditory feedback (aFB) may be a useful approach. We sensorized forearm crutches and developed a custom software to provide aFB information to both user and physical therapist (PhT). Aim: Evaluate aFB effects on load control during gait by a self-controlled case series trial. Methods: A single experimental session was conducted enrolling 12 CNS lesioned participants. Load on crutch was recorded during 10 Meter Walk Test performed with and without aFB. In both cases, crutch load data, and gait speed were recorded. Usability and satisfaction questionnaires were administered to participants and PhTs involved. Results: Reliable data were obtained from eight participants. Results showed that compared to the no FB condition, aFB yielded a significant reduction in the mean load on the crutches during gait (p = 0.001). The FB did not influence gait speed or fatigue (p > 0.05). The experience questionnaire data indicated a positive experience regarding the use of aFB from both participants' and PhTs' perspectives. Conclusion: aFB significantly improves compliance with crutch use and does not affect gait speed or fatigue by improving the load placed on crutches. The FB is perceived by users as helpful, safe, and easy to learn, and does not interfere with attention or concentration while walking. Furthermore, the PhTs consider the system to be useful, easy to learn and reliable.

4.
Data Brief ; 35: 106791, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33604423

RESUMO

The HANDS dataset has been created for human-robot interaction research, and it is composed of spatially and temporally aligned RGB and Depth frames. It contains 12 static single-hand gestures performed with both the right-hand and the left-hand, and 3 static two-hands gestures for a total of 29 unique classes. Five actors (two females and three males) have been acquired performing the gestures, each of them adopting a different background and light conditions. For each actor, 150 RGB frames and their corresponding 150 Depth frames per gesture have been collected, for a total of 2400 RGB frames and 2400 Depth frames per actor. Data has been collected using a Kinect v2 camera intrinsically calibrated to spatially align RGB data to Depth data. The temporal alignment has been performed offline using MATLAB, aligning frames with a maximum temporal distance of 66  ms. This dataset has been used in [1] and it is freely available at http://dx.doi.org/10.17632/ndrczc35bt.1.

5.
Sensors (Basel) ; 20(14)2020 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-32668739

RESUMO

This paper presents the validation of a marker-less motion capture system used to evaluate the upper limb stress of subjects using exoskeletons for locomotion. The system fuses the human skeletonization provided by commercial 3D cameras with forces exchanged by the user to the ground through upper limbs utilizing instrumented crutches. The aim is to provide a low cost, accurate, and reliable technology useful to provide the trainer a quantitative evaluation of the impact of assisted gait on the subject without the need to use an instrumented gait lab. The reaction forces at the upper limbs' joints are measured to provide a validation focused on clinically relevant quantities for this application. The system was used simultaneously with a reference motion capture system inside a clinical gait analysis lab. An expert user performed 20 walking tests using instrumented crutches and force platforms inside the observed volume. The mechanical model was applied to data from the system and the reference motion capture, and numerical simulations were performed to assess the internal joint reaction of the subject's upper limbs. A comparison between the two results shows a root mean square error of less than 2% of the subject's body weight.


Assuntos
Muletas , Exoesqueleto Energizado , Articulações/fisiologia , Extremidade Superior/fisiologia , Fenômenos Biomecânicos , Marcha , Humanos , Caminhada
6.
J Hypertens ; 36(5): 1154-1163, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29578964

RESUMO

BACKGROUND: The evaluation of the morphological characteristics of small resistance arteries in humans is challenging. The gold standard method is generally considered to be the measurement by wire or pressure micromyography of the media-to-lumen ratio of subcutaneous small vessels obtained by local biopsies. However, noninvasive techniques for the evaluation of retinal arterioles were recently proposed; in particular, two approaches, scanning laser Doppler flowmetry (SLDF) and adaptive optics, seem to provide useful information; both of them provide an estimation of the wall-to-lumen ratio (WLR) of retinal arterioles. Moreover, a noninvasive measurement of basal and total capillary density may be obtained by videomicroscopy/capillaroscopy. No direct comparison of these three noninvasive techniques in the same population was previously performed; in particular, adaptive optics was never validated against micromyography. METHODS: In the current study, we enrolled 41 controls and patients: 12 normotensive lean controls, 12 essential hypertensive lean patients, nine normotensive obese patients and eight hypertensive obese patients undergoing elective surgery. All patients underwent a biopsy of subcutaneous fat during surgery. Subcutaneous small resistance artery structure was assessed by wire micromyography and the media-to-lumen ratio was calculated. WLR of retinal arterioles was obtained by SLDF and adaptive optics. Functional (basal) and structural (total) microvascular density was evaluated by capillaroscopy before and after venous congestion. RESULTS AND CONCLUSION: Our data suggest that adaptive optics has a substantial advantage over SLDF in terms of evaluation of microvascular morphology, as WLR measured with adaptive optics is more closely correlated with the M/L of subcutaneous small arteries (r = 0.84, P < 0.001 vs. r = 0.52, P < 0.05, slopes of the relations: P < 0.01 adaptive optics vs. SLDF). In addition, the reproducibility of the evaluation of the WLR with adaptive optics is far better, as compared with SLDF, as intraobserver and interobserver variation coefficients are clearly smaller. This may be important in terms of clinical evaluation of microvascular morphology in a clinical setting, as micromyography has substantial limitations in its clinical application due to the local invasiveness of the procedure.


Assuntos
Arteríolas/diagnóstico por imagem , Hipertensão Essencial/diagnóstico por imagem , Fluxometria por Laser-Doppler/métodos , Angioscopia Microscópica , Imagem Óptica/métodos , Vasos Retinianos/diagnóstico por imagem , Adulto , Idoso , Artérias/fisiopatologia , Arteríolas/patologia , Biópsia , Pressão Sanguínea , Hipertensão Essencial/complicações , Hipertensão Essencial/patologia , Feminino , Humanos , Masculino , Microscopia de Vídeo , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/diagnóstico por imagem , Obesidade/patologia , Reprodutibilidade dos Testes , Gordura Subcutânea/irrigação sanguínea , Gordura Subcutânea/patologia , Magreza/complicações , Magreza/diagnóstico por imagem , Magreza/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...