Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Case Rep Oncol ; 17(1): 532-536, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38567168

RESUMO

Introduction: Capecitabine has rarely been associated with neurotoxicity. Cerebellar ataxia, multifocal leukoencephalopathy, and sensorimotor peripheral neuropathy have been reported in the literature. A case of 6th nerve palsy associated with capecitabine has also been described. This article reports the first case of capecitabine-related 4th nerve palsy. Case Presentation: A 72-year-old Caucasian woman was referred by the Oncology Department because she had been complaining of binocular diplopia for 6 months. The symptoms started 1 month after the introduction of capecitabine. A diagnosis of right 4th nerve palsy was made using the Parks three-step test and the Hess test. Neuroimaging analysis was negative. A slow but progressive deterioration of function was confirmed during a year of follow-up. On suspicion of a chemotherapy-related palsy, capecitabine was discontinued and switched to vinorelbine. Subsequent improvement of the clinical picture was confirmed within 2 months. Conclusion: The recognition of chemotherapy-related neurotoxicity is of paramount importance in the management of oncology patients. Once secondary invasion of the brain or the orbit by the tumor itself is ruled out, it must be suspected to prevent further deterioration.

2.
Eur J Ophthalmol ; : 11206721241245743, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576315

RESUMO

PURPOSE: To analyse the long anatomical and functional outcome of a subgroup of the DICAT II study cohort, consisting of 26 patients undergoing cataract surgery and withdrawn from the study for a clinically significant worsening of early diabetic macular edema (DME). MATERIALS: Patients who underwent cataract surgery and withdrawn from the DICAT II study for a clinically significant worsening of early DME with at least 12 months follow-up after the dropout. The study population was divided into two groups according to the clinical evaluation at one-year follow-up: ongoing treatment patients for DME (Treatment group, TG) and patients no longer treated (Non Treatment group, NTG). RESULTS: Central foveal thickness (CFT) at baseline and dropout time were higher in TG than in the NTG, with a statistically significant difference (p < 0.05). In addition, TG patients reported a higher levels of glycated hemoglobin at time baseline compared to NTG patients (7.81 ± 1.15 vs 7.02 ± 0.56; p = 0.048). The linear regression analysis demonstrated a statistically significant relationship between the visual acuity and the ongoing treatment group at one-year follow-up (p = 0.042). CONCLUSION: The study provides parameters to be considered when assessing the risk of developing persistent DME after cataract surgery in diabetic patients. In particular, CFT at baseline and dropout time have been reported to be an effective and predictable OCT biomarkers when evaluating DME progression. During the evaluation of the systemic disease, similar results were found for the glycated hemoglobin at baseline.

3.
J Cataract Refract Surg ; 50(6): 605-610, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350232

RESUMO

PURPOSE: To evaluate which secondary intraocular lens (IOL) implantation technique was more successful in achieving the best postoperative results and refractive outcomes between retropupillary iris-claw IOL (ICIOL) and flanged intrascleral IOL (FIIOL) fixation with the Yamane technique. SETTING: Eye Clinic of the University of Trieste, Trieste, Italy. DESIGN: Retrospective observational study. METHODS: 116 eyes of 110 patients who underwent ICIOL or FIIOL were analyzed. Patients with follow-up shorter than 6 months or with incomplete clinical data were excluded. Collected data included demographics, ocular comorbidity, indication of surgery, intraocular pressure, early (≤1 month) and late (>1 month) postoperative complications, corrected distance visual acuity (CDVA), and manifest refraction at the last follow-up visit. RESULTS: 50% (n = 58) of eyes underwent FIIOL and 50% (n = 58) ICIOL implantation for aphakia (n = 44, 38%) and IOL dislocation (n = 72, 62%). No statistically significant differences in demographics, comorbidity, follow-up duration, postoperative complications, and surgical indications were found. The refractive prediction error (RPE) was 0.69 ± 0.94 diopter (D) in the FIIOL group and 0.21 ± 0.75 D in the ICIOL group ( P = .03), indicating residual hyperopia after both techniques. RPE, mean absolute error, and median absolute error were higher in the FIIOL group ( P = .003). ICIOL implantation was more successful in obtaining a RPE between -0.50 D and +0.50 D (52% of ICIOL, n = 30, and 31% of FIIOL, n = 18). CONCLUSIONS: Both techniques were effective in increasing preoperative CDVA with no statistical difference between them. Although complication rates did not significantly differ, the FIIOL group exhibited less predictable refractive outcomes. Adjusting the dioptric power of the 3-piece IOL, as performed in ciliary sulcus implantation, to prevent myopic shift, is not recommended.


Assuntos
Iris , Implante de Lente Intraocular , Lentes Intraoculares , Refração Ocular , Acuidade Visual , Humanos , Estudos Retrospectivos , Acuidade Visual/fisiologia , Implante de Lente Intraocular/métodos , Iris/cirurgia , Masculino , Feminino , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Idoso , Seguimentos , Facoemulsificação , Pseudofacia/fisiopatologia , Complicações Pós-Operatórias , Adulto , Resultado do Tratamento
4.
Sci Rep ; 14(1): 1441, 2024 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-38228633

RESUMO

To report long-term outcomes of brolucizumab in neovascular age-related macular degeneration (nAMD) treatment. Records from 74 patients were retrospectively reviewed. Both naïve eyes and those previously treated with other antiVEGF agents were included. Primary outcomes included variation in best corrected visual acuity (BCVA), central subfield thickness (CST), intraretinal fluid (IRF), subretinal fluid (SRF), and pigment epithelial detachment (PED) dimensions. Outcomes were reviewed after the loading phase, at week 24, and at last follow-up. IOI occurrence represented the secondary outcome. BCVA improved significantly in both groups. In switched eyes, IRF and SRF were significantly reduced at every timepoint, with CST reduction from week 24 (p = 0.005). In naïve group, CST decreased from the loading phase (p = 0.006) and all patients showed dry macula from week 24. A significant reduction in PED maximum high was demonstrated in both groups. In seven naïve eyes, PED completely reabsorbed; a slight increase in PED horizontal maximal diameter was also observed from week 24. IOI occurred in 5.4% of cases. In conclusion, brolucizumab showed a strong drying effect, permitting functional improvement together with fluid reabsorption and an encouraging modification of PED dimension, especially on naïve patients. These results together with the extension of treatment intervals make brolucizumab an efficient therapeutic strategy for nAMD.


Assuntos
Anticorpos Monoclonais Humanizados , Descolamento Retiniano , Degeneração Macular Exsudativa , Humanos , Inibidores da Angiogênese , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Injeções Intravítreas , Descolamento Retiniano/tratamento farmacológico , Degeneração Macular Exsudativa/tratamento farmacológico
5.
J Clin Med ; 11(24)2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36555917

RESUMO

BACKGROUND: To evaluate and compare the visual function and the quality of life (QoL) in glaucomatous patients treated with topical medical therapy (TMT) alone, canaloplasty (CP), or trabeculectomy (TB). METHODS: A total of 291 eyes of 167 patients with primary open-angle glaucoma or secondary pseudoexfoliative glaucoma in TMT or surgically treated with CP or TB were included. Eligibility criteria for surgical patients included not needing TMT after surgery. Each patient underwent a visual field assessment and peripapillary retinal nerve fiber layer (pRNFL) optical coherence tomography and filled out the Glaucoma Symptoms Scale (GSS) questionnaire and the 25-Item National Eye Institute Visual Functioning Questionnaire (25-NEI-VFQ). Comparison between the QoL level of the three groups and its correlation with optic nerve's anatomical and functional status was the primary outcome. RESULTS: CP patients reported the best general vision (p = 0.01), a lower incidence of eye burning (p = 0.03), and the lowest annoyance level of non-visual symptoms (p = 0.006). QoL positively correlated with pRNFL thickness, whereas no correlation was found with visual field damage. CONCLUSION: CP provides a better QoL when compared both to TB and TMT, regardless of glaucoma stage. pRNFL seems to provide additional information for predicting change in QoL.

6.
Diagnostics (Basel) ; 12(8)2022 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-36010258

RESUMO

Purpose: to investigate the reproducibility and reliability of OCT-A vascular measurements using Heidelberg Spectralis II OCT-A. Methods: a prospective study involving a single eye of patients aged 18 or older with no ocular disease. In order to investigate the reliability of the first and second OCT-A scans, the coefficient of variation of the foveal avascular zone (FAZ) and the vessel density (VD) in the superficial (SCP), intermediate (ICP) and deep capillary plexus (DCP) were calculated. Results: A total of 75 eyes were included in the study. The mean FAZ in the first and second scan was 0.36 × 0.13 mm2 and 0.37 × 0.12 mm2, respectively, in the SCP, 0.23 × 0.10 mm2 and 0.23 × 0.09 mm2 in the ICP, and 0.42 × 0.11 mm2 and 0.43 × 0.12 mm2 in the DCP. The overall VD was 36.05 × 9.01 and 35.33 × 9.92 at the first and second scan, respectively, in the SCP, 21.87 × 5.00 and 21.32 × 5.56 in the ICP, and 23.84 × 6.53 and 23.20 × 6.83 in the DCP. No statistically significant differences in FAZ measurements and VD in all sectors of each capillary plexus were observed between the first and second scan (p > 0.05). Conclusion: our study demonstrated the good reproducibility and reliability of OCT-A vascular measurements in the analysis of the FAZ and the quantification of VD in each capillary plexus of the retina.

8.
Graefes Arch Clin Exp Ophthalmol ; 260(1): 289-293, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34427741

RESUMO

PURPOSE: In the era of antibiotic resistance, there is an increased interest in antiseptic solutions that might represent a reliable option for ocular surface disinfection. The objective of this study is to compare for the first time three different antiseptic ophthalmic preparations to assess their in vitro antimicrobial activity. METHODS: The antiseptic activity of three commercial ophthalmic solutions, IODIM (povidone-iodine 0.6% in hyaluronic acid vehicle-Medivis, Catania, Italy), OZODROP (nanoemulsion with ozonated oil-concentration not specified-FBVision, Ophthalmic Pharmaceuticals, Rome, Italy), and DROPSEPT (chlorhexidine 0.02% and vitamin E 0.5% Tocopherol Polyethylene Glycol 1000 Succinate-TPGS, Sooft Italia, Montegiorgio, Italy), was tested in vitro on six reference strains by time-killing assays. Viable cells were evaluated after 1, 15, 30 min; 2, 6, and 24 h exposure by seeding 100 µl of the suspension (or appropriate dilutions) on LB agar or Sabouraud-dextrose agar. All plates were incubated at 37 °C for 24 h and evaluated by manually counting the colonies. RESULTS: IODIM solution showed a very rapid microbicidal activity: the number of viable cells for all the tested strains was under the detection limit (less than 10 CFU/ml) already after 1 min exposure, and this result was maintained at every incubation time. The rapid antimicrobial activity of povidone-iodine was not replicated when testing the other two antiseptics. CONCLUSIONS: The study reports the great efficacy in reducing bacterial load in a very short time of povidone-iodine 0.6% compared with other antiseptic preparations.


Assuntos
Anti-Infecciosos Locais , Anti-Infecciosos Locais/farmacologia , Clorexidina , Desinfecção , Soluções Oftálmicas , Povidona-Iodo/farmacologia
9.
Graefes Arch Clin Exp Ophthalmol ; 260(3): 913-916, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34605952

RESUMO

PURPOSE: To evaluate the surface profile of a new-generation extended range-of-vision intraocular lens (IOL) and to compare it with that obtained for a monofocal IOL based on the same platform. METHODS: Prospective, experimental, laboratory study comparing the surface profile of the DFT015 (AcrySof IQ Vivity; Alcon Laboratories, Inc.), a new-generation presbyopia-correcting IOL, with the profile of the SN60WF (AcrySof IQ; Alcon Laboratories, Inc.), an aspheric monofocal IOL based on the same platform. Raw profiles were obtained using contact profilometry. The best-fit form was then subtracted from each raw profile to highlight potential differences. RESULTS: No significant differences were appreciated in raw profiles. On the contrary, after form removal, the new extended range-of-vision IOL showed a peculiar profile characterized by the presence of two altitudinal symmetrical changes in the order of 1 µm, localized in the central portion of the optic. CONCLUSIONS: The new-generation extended range-of-vision IOL evaluated showed a smooth change of its surface compared to the same platform monofocal IOL. The altitudinal changes blended in the central design of the new presbyopia-correcting IOL, although micrometric, might play a crucial role in creating a continuous focal range while minimizing visual disturbances.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Laboratórios , Implante de Lente Intraocular , Estudos Prospectivos , Desenho de Prótese , Acuidade Visual
10.
Eye (Lond) ; 36(8): 1687-1693, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34345028

RESUMO

BACKGROUND: The prospective DIabetes and CATaract Study II (DICAT II) was performed to characterise the risks of cataract surgery to the retinae of patients with early diabetic macular oedema (E-DMO). METHODS: DICAT II was a prospective, comparative, multicentre, observational study involving six Italian clinics. Patients were aged ≥55 years, had type 1 or 2 diabetes with spectral-domain optical coherence tomography evidence of ESASO classification Early DMO. Group 1 eyes (78 eyes, 78 patients) underwent phacoemulsification-based cataract surgery. Group 2 eyes (65 eyes, 65 patients) had E-DMO and either clear media or had undergone uncomplicated cataract surgery ≥1 year previously. Central subfield thickness (CST) and best-corrected visual acuity (BCVA) were assessed in both groups. RESULTS: The negative impact of surgery on CST was evident after the first postoperative week; CST peaked during the first month, then rapidly decreased. CST worsening ≥10 µm was observed in 63/78 eyes (80.7%) and 29/65 eyes (44.6%) in Groups 1 and 2, respectively (p < 0.0001). CST worsening of ≥50 µm was observed in 51 eyes (65.4%) and 10 eyes (15.4%) in Groups 1 and 2, respectively (p < 0.0001). Mean CST worsening was lower in Group 2 than in Group 1 (38.6 ± 30.4 µm vs 85.5 ± 55.3 µm, p < 0.0001) with a lower BCVA loss (-2.6 ± 3.5 letters vs -8.2 ± 6.2 letters, p < 0.0001). Higher glycaemic levels and HBA1c levels were significantly associated with the risk of >50 µm CST worsening in eyes from both groups. CONCLUSION: Early DMO is associated with poorer outcomes after cataract surgery and requires close pre- and postoperative monitoring.


Assuntos
Catarata , Diabetes Mellitus , Retinopatia Diabética , Edema Macular , Catarata/complicações , Retinopatia Diabética/complicações , Retinopatia Diabética/cirurgia , Humanos , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos , Acuidade Visual
11.
Sci Rep ; 11(1): 23271, 2021 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-34857862

RESUMO

To investigate the antimicrobial activity of a preservative-free 0.6% povidone-iodine eye drop as an antiseptic procedure in decreasing the conjunctival bacterial load in eyes scheduled for intravitreal treatment and to compare its efficacy to the untreated fellow eye used as the control group. Prospective cohort analysis in which 208 patients received preservative-free 0.6% povidone-iodine eye drops three times a day for three days before intravitreal injection. Before and after the prophylactic treatment, a conjunctival swab was collected from both the study eye and the untreated contralateral eye, used as control. The swab was inoculated on different culture media and the colony-forming units were counted. Bacteria and fungi were identified by matrix-assisted laser desorption ionization time-of-flight mass spectrometry. Treatment with 0.6% povidone-iodine eye drops significantly reduced the conjunctival bacterial load from baseline (p < 0.001 for blood agar and p < 0.001 for chocolate agar) with an eradication rate of 80%. The most commonly isolated pathogen at each time-point and in both groups was coagulase-negative Staphylococci, isolated in 84% of the positive cultures. The study provides evidence about the effectiveness of 0.6% povidone-iodine eye drops treatment in reducing the conjunctival bacterial load in eyes scheduled for intravitreal treatment.


Assuntos
Anti-Infecciosos , Antibioticoprofilaxia/métodos , Carga Bacteriana/efeitos dos fármacos , Túnica Conjuntiva/microbiologia , Soluções Oftálmicas/administração & dosagem , Soluções Oftálmicas/farmacologia , Povidona-Iodo/administração & dosagem , Povidona-Iodo/farmacologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Injeções Intravítreas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
12.
Diagnostics (Basel) ; 11(12)2021 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-34943441

RESUMO

BACKGROUND: Retinal nerve fiber layer (RNFL) and ganglion cell layer (GCL) measurements can be influenced by many factors including the presence of concomitant retinal diseases. The aim of this study it to assess the impact of epiretinal membrane (ERM) on RNFL and GCL assessment using optical coherence tomography (OCT). METHODS: GCL, peripapillary RNFL (pRNFL), and Bruch's Membrane Opening Minimum Rim Width (BMO-MRW) thicknesses were analysed using an SD-OCT (Spectralis OCT) in eyes with idiopathic ERM and compared with a control group. RESULTS: 161 eyes were included, 73 eyes in the control group and 88 eyes with idiopathic ERM. The pRNFL analysis revealed a statistically significant difference between the two groups in overall and temporal sector thicknesses. For GCL thickness report, the percentage of scans in which the GCL was erroneously segmented by automatic segmentation was assessed for each eye. A statistically significant difference was found in all sectors (p < 0.001), with the exception of external nasal sector. A statistically significant difference (p < 0.001) in the GCL total volume report was found in ERM group compared to the control group. For MRW at BMO analysis, there was no statistically significant difference in MRW thickness in any sector. CONCLUSION: In eyes with ERM, the GCL and pRNFL analysis seemed affected by the morphological retinal layers' modification. MRW-BMO did not appear to be directly affected by the presence of ERM.

13.
Eur J Ophthalmol ; 31(3): 1313-1319, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32460546

RESUMO

PURPOSE: To test the stiffness and displacement of different vitreous forceps. Physical features and deformation after multiple procedures were also measured. METHODS: Eleven different 23-, 25-, and 27-gauge vitreous forceps were studied. The measurements were repeated loading the probe at different distances from the tip: at the top of the tip and 10 and 20 mm from the tip, respectively. For each probe, 10 successive identical bending tests were performed. The total length and the internal and external diameters of each forceps were also measured. RESULTS: A total of 330 successive identical bending tests were performed. No progression in deformation after the repeated measurements was recorded (p > 0.05). In each gauge group, displacement differences were detected according to the manufacturing metal properties, the total length, and the thickness of the shaft wall. A minimal adequate model to describes forceps displacements in terms of their significant predictors, such as gauge, model, and load distance from the tip, was created. CONCLUSION: We provided a precise assessment of the stiffness and displacement of different vitreous forceps to enable surgeons to select the optimal instrument according to the benefits and limitations of each forceps.


Assuntos
Microcirurgia , Vitrectomia , Humanos , Estudos Retrospectivos , Instrumentos Cirúrgicos
15.
Eur J Ophthalmol ; 30(1): NP29-NP32, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30832497

RESUMO

PURPOSE: To report a 72-year-old man with orbital metastasis as presenting symptoms from a prostatic adenocarcinoma. METHODS: A complete ophthalmological evaluation with ultrasonography examination, kinetic perimetry, fluorescein angiography, and visually evoked potentials were performed. The patient underwent computed tomography, magnetic resonance imaging of the orbit, and blood test for confirmation of the diagnosis. Bone infiltration rate of the cancer was evaluated with bone scintigraphy. Type of the tumor was assessed with orbital incision biopsy and histological analysis. The patient received systemic chemotherapy. Due to poor patient compliance, radiotherapy was not performed. RESULTS: Ultrasonography showed a hypoechoic retrobulbar lesion. At computed tomography examination of the orbit an expansive oval intraconical solid lesion with enhancement after medium contrast was found. Biopsy findings revealed a moderately differentiated adenocarcinoma with immunohistochemical profile supporting prostate as the primary tumor site: negative for cytokeratin-7 and cytokeratin-20 and positive for prostate-specific antigen, prostate-specific acid phosphatase, and alpha-methylacyl-CoA-racemase. CONCLUSIONS: Ocular signs and symptoms as first clinical presentation of a prostate cancer are relatively rare. Despite its very poor prognosis, a correct management and therapy can improve visual acuity, ocular symptoms, and median survival of cancer patients.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/secundário , Neoplasias Orbitárias/diagnóstico por imagem , Neoplasias Orbitárias/secundário , Neoplasias da Próstata/patologia , Adenocarcinoma/metabolismo , Adenocarcinoma/fisiopatologia , Idoso , Biomarcadores Tumorais/metabolismo , Biópsia , Potenciais Evocados Visuais/fisiologia , Angiofluoresceinografia , Humanos , Imageamento por Ressonância Magnética , Masculino , Proteínas de Neoplasias/metabolismo , Neoplasias Orbitárias/metabolismo , Neoplasias Orbitárias/fisiopatologia , Tomografia Computadorizada por Raios X , Acuidade Visual/fisiologia
16.
Retina ; 40(9): 1838-1845, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31800462

RESUMO

PURPOSE: To evaluate the vitreous concentration of different nonsteroidal anti-inflammatory drugs (NSAIDs) after topical administration and the related prostaglandin E2 (PGE2) levels in patients undergoing pars plana vitrectomy. METHODS: A prospective, randomized, investigator-masked study was performed. One hundred four patients scheduled for a pars plana vitrectomy for an epiretinal membrane or a macular hole were randomized to receive topical diclofenac 0.1%, indomethacin 0.5%, nepafenac 0.3%, bromfenac 0.09%, or placebo 3 days before surgery. At the beginning of surgery, a sample of undiluted vitreous was collected in each patient to assess NSAIDs concentration and PGE2 levels. RESULTS: The median vitreous concentrations were 203.35 (interquartile range 146.54-264.18) pg/mL for diclofenac, 243.45 (interquartile range 156.96-365.37) pg/mL for nepafenac, 438.21 pg/mL (interquartile range, 282.52-645.87) for its active metabolite amfenac, 350.14 (interquartile range, 290.88-481.95) pg/mL for indomethacin, and 274.59 (245.43-358.25) pg/mL for bromfenac. Vitreous PGE2 levels were significantly lower for all the NSAIDs groups compared with the control group (P < 0.001). A statistically significant higher vitreous PGE2 level was found in the diclofenac group compared with the other NSAIDs groups (P < 0.05). CONCLUSION: Topical NSAIDs achieve sufficient vitreous concentration to decrease vitreous PGE2 levels compared with the control group. The different efficacy in reducing PGE2 concentration may affect the management of posterior segment inflammation.


Assuntos
Anti-Inflamatórios não Esteroides/administração & dosagem , Dinoprostona/metabolismo , Corpo Vítreo/metabolismo , Administração Oftálmica , Idoso , Idoso de 80 Anos ou mais , Anti-Inflamatórios não Esteroides/farmacocinética , Benzenoacetamidas/administração & dosagem , Benzenoacetamidas/farmacocinética , Benzofenonas/administração & dosagem , Benzofenonas/farmacocinética , Bromobenzenos/administração & dosagem , Bromobenzenos/farmacocinética , Cromatografia Líquida de Alta Pressão , Diclofenaco/administração & dosagem , Diclofenaco/farmacocinética , Método Duplo-Cego , Ensaio de Imunoadsorção Enzimática , Membrana Epirretiniana/metabolismo , Membrana Epirretiniana/cirurgia , Feminino , Humanos , Indometacina/administração & dosagem , Indometacina/farmacocinética , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Fenilacetatos/administração & dosagem , Fenilacetatos/farmacocinética , Estudos Prospectivos , Perfurações Retinianas/metabolismo , Perfurações Retinianas/cirurgia , Vitrectomia
17.
J Cataract Refract Surg ; 45(9): 1330-1334, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31371148

RESUMO

PURPOSE: To analyze and compare the surface properties of commercially available hydrophobic acrylic intraocular lenses (IOLs). SETTING: Eye Clinic, University of Trieste, Italy. DESIGN: Experimental study. METHODS: The following 6 single-piece hydrophobic acrylic IOL models with the same dioptric power were studied and compared: Clareon SY60WF, Tecnis PCB00, enVista MX60, CT Lucia 601P, Vivinex iSert XY1, and iSert 251. Topography of the IOL surface was analyzed using atomic force microscopy (AFM). Surface contact angle measurements using the sessile drop method were performed to assess IOL wettability. RESULTS: The AFM analysis showed that the Vivinex iSert XY1 IOL and Clareon SY60WF IOL had the lowest surface roughness (P < .05); there was no statistically significant difference in surface roughness between the those 2 IOL models (P > .05). Surface contact angle measurements showed that the iSert 251 IOL had the highest hydrophobicity. The CT Lucia 601P IOL had the lowest contact angle of all IOL models. CONCLUSIONS: The AFM analysis and surface contact angle measurements of all IOLs tested showed that the Vivinex iSert XY1 IOL and Clareon SY60WF IOL had the best topographic features. The smoother, more regular surface of these new IOL models might reduce cell adhesion and therefore lower the incidence of posterior capsule opacification.


Assuntos
Resinas Acrílicas , Materiais Biocompatíveis/química , Lentes Intraoculares , Propriedades de Superfície , Opacificação da Cápsula/prevenção & controle , Adesão Celular/fisiologia , Microscopia de Força Atômica , Cápsula Posterior do Cristalino/fisiologia , Desenho de Prótese , Molhabilidade
18.
Sci Rep ; 9(1): 9912, 2019 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-31289313

RESUMO

The aim of this study was to assess the central macular imaging captured with an optical biometer based on full-eye-length Swept-Source OCT (SS-OCT) scan as a screening strategy for identifying macular diseases in patients scheduled for cataract surgery. 1,114 eyes of 749 consecutive patients underwent a biometrical examination with IOLMaster 700 SS-OCT technology (Carl Zeiss) and conventional Spectral-Domain OCT (SD-OCT) (Spectralis OCT, Heidelberg) device analysis on the same day. Seven examiners graded the scans individually in a full-masked mode. Twenty-five eyes were excluded for media opacities. Among the 1,089 included eyes, statistical analysis revealed a mean Kendall's Coefficient of 0.83 (range 0.76-0.89). A logistic regression model demonstrated a highly significant correlation (p < 0.001) between the coefficient of concordance and SD-OCT imaging. Intraobserver reproducibility was 0.89 (range 0.86-0.91). Optical biometer SS-OCT scans showed a mean sensitivity of 0.81 and a mean specificity of 0.84. The positive and negative predictive value detected was 0.78 and 0.86, respectively. In order to predict the risk of reduced visual recovery, especially in cases of retinal pathology, optical biometer with SS-OCT scan has proven to be a useful modality for detecting macular structural abnormalities in patients undergoing cataract surgery. Conventional SD-OCT remains mandatory to confirm the presumed diagnosis.


Assuntos
Extração de Catarata/métodos , Catarata/fisiopatologia , Degeneração Macular/diagnóstico , Programas de Rastreamento/métodos , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Degeneração Macular/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Método Simples-Cego
20.
J Ophthalmol ; 2019: 3230695, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30984418

RESUMO

Macular hole (MH) in myopic eyes is a disease arising from complex tractional forces exerted by vitreomacular interface, epiretinal tissue, and progressive scleral ectasia of the posterior ocular globe wall. This retinal disease requires vitreoretinal treatment for its repair, and the surgical intervention remains a challenge also for experienced surgeons. The aim of this review is to describe the current knowledge regarding the pathogenesis of MH in myopic eyes and to detail novel surgical techniques and technological advancements in its surgical management.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...