Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Scand J Med Sci Sports ; 27(11): 1356-1363, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27430594

RESUMO

Cold-water immersion (CWI) is one of the recovery techniques commonly used by athletes for post-exercise recovery. Nevertheless, the effects of CWI using different temperatures and the dose-response relationship of this technique have not yet been investigated. The aims of this study were to compare the effects of two strategies of CWI, using different water temperatures with passive recovery post exercise in the management of some markers of muscle damage, and to observe whether any of the techniques used caused deleterious effects on performance. Sixty healthy male participants performed an eccentric protocol to induce muscle damage and were then randomized to one of three groups (CWI1: 15 min at 9 °C; CWI2: 15 min at 14 °C; CG: control group). Levels of creatine kinase, muscle soreness, pain threshold, perception of recovery, and maximal voluntary isometric contraction were monitored up to 96 h post exercise. A large effect for time for all outcomes was observed [P < 0.001; CK (ES = 0.516), muscle soreness (ES = 0.368); pain threshold (ES = 0.184); perception of recovery (ES = 0.565); MVIC (ES = 0.273)]. CWI groups presented an earlier recovery for muscle soreness with lower ratings immediately post recovery. For delayed effects, the application of CWI2 (15 min at 14 °C) presented earlier recovery compared with CWI1 and control condition for maximal voluntary isometric contraction (P < 0.05). There were no significant group and interaction (Group × Time) effects. CWI groups acted more efficiently for muscle soreness and performance considering the time of recovery was observed. No evidence was found to suggest dose-response relationship and deleterious effects.


Assuntos
Temperatura Baixa , Exercício Físico/fisiologia , Músculo Esquelético/fisiologia , Mialgia/terapia , Água , Creatina Quinase/sangue , Humanos , Imersão , Contração Isométrica , Masculino , Limiar da Dor , Recuperação de Função Fisiológica , Adulto Jovem
2.
Eur J Phys Rehabil Med ; 49(6): 793-801, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23698474

RESUMO

BACKGROUND: The chronic obstructive pulmonary disease (COPD) is associated with the strength and resistance decreasing in addition to the dysfunction on autonomic nervous system (ANS). The aerobic training isolated or in association with the resistance training showed evidence of beneficial effects on an autonomic modulation of COPD; however, there are no studies addressing the effect of isolated resistance training. AIMS: This study aims at investigating the influence of resistance training on an autonomic modulation through heart rate variability (HRV), functional capacity and muscle strength in individuals with COPD. DESIGN: Clinical series study. SETTING: Outpatients. POPULATION: The study involved 13 individuals with COPD. METHODS: The experimental protocol was composed by an initial and final evaluation that consisted in autonomic evaluations (HRV), cardiopulmonary functional capacity evaluation (6-minute walk test) and strength evaluation (dynamometry) in addition by the resistance training performed by 24 sessions lasted 60 minutes each one and on a frequency of three times a week. The intensity was determined initially with 60% of one maximum repetition and was progressively increased in each five sessions until 80%. RESULTS: The HRV temporal and spectral indexes analysis demonstrates improvement of autonomic modulation, with significant statistical increases to sympathetic and parasympathetic components of ANS representing by SDNN, LF and HF. In addition, it was observed significant statistical increases to shoulder abduction and knee flexion strength and functional capacity. CONCLUSION: The exclusive resistance training performed was able to positively influence the autonomic modulation; in addition it promoted benefits on cardiorespiratory functional capacity and strength benefits in individuals with COPD. CLINICAL REHABILITATION IMPACT: This study could contribute to clinical and professionals researchers that act with COPD, even though the resistance component of pulmonary rehabilitation presents consensual benefits on several healthy indicators parameters. There is no evidence about the effects on HRV before. Moreover, this study showed, on clinical practice, the HRV uses as an ANS activity on sinus node evaluation and highlights further importance on scientific context.


Assuntos
Sistema Nervoso Autônomo/fisiopatologia , Frequência Cardíaca/fisiologia , Força Muscular/fisiologia , Doença Pulmonar Obstrutiva Crônica/reabilitação , Treinamento Resistido , Idoso , Idoso de 80 Anos ou mais , Brasil , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Centros de Reabilitação
3.
Int J Sports Med ; 33(11): 873-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22722961

RESUMO

The aim of the present study was to investigate the potential benefits of cold water immersion (CWI) and active recovery (AR) on blood lactate concentration ([Lac]) and heart rate variability (HRV) indices following high-intensity exercise. 20 male subjects were recruited. On the first visit, an incremental test was performed to determine maximal oxygen consumption and the associated speed (MAS). The remaining 3 visits for the performance of constant velocity exhaustive tests at MAS and different recovery methods (6 min) were separated by 7-day intervals [randomized: CWI, AR or passive recovery (PR)]. The CWI and AR lowered [Lac] (p<0.05) at 11, 13 and 15 min after exercise cessation in comparison to PR. There was a 'time' and 'recovery mode' interaction for 2 HRV indices: standard deviation of normal R-R intervals (SDNN) (partial eta squared=0.114) and natural log of low-frequency power density (lnLF) (partial eta squared=0.090). CWI presented significantly higher SDNN compared to PR at 15 min of recovery (p<0.05). In addition, greater SDNN values were found in CWI vs. AR during the application of recovery interventions, and at 30 and 75 min post-exercise (p<0.05 for all differences). The lnLF during the recovery interventions and at 75 min post-exercise was greater using CWI compared with AR (p<0.05). For square root of the mean of the sum of the squares of differences between adjacent R-R intervals (RMSSD) and natural log of high-frequency power density (lnHF), a moderate effect size was found between CWI and PR during the recovery interventions and at 15 min post-exercise. Our findings show that AR and CWI offer benefits regarding the removal of [Lac] following high-intensity exercise. While limited, CWI results in some improvement in post-exercise cardiac autonomic regulation compared to AR and PR. Further, AR is not recommended if the aim is to accelerate the parasympathetic reactivation.


Assuntos
Temperatura Baixa , Frequência Cardíaca/fisiologia , Ácido Láctico/sangue , Consumo de Oxigênio/fisiologia , Teste de Esforço , Humanos , Imersão , Masculino , Corrida/fisiologia , Fatores de Tempo , Adulto Jovem
4.
Braz J Med Biol Res ; 41(10): 854-9, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18853042

RESUMO

The aim of the present study was to compare heart rate variability (HRV) at rest and during exercise using a temporal series obtained with the Polar S810i monitor and a signal from a LYNX(R) signal conditioner (BIO EMG 1000 model) with a channel configured for the acquisition of ECG signals. Fifteen healthy subjects aged 20.9 +/- 1.4 years were analyzed. The subjects remained at rest for 20 min and performed exercise for another 20 min with the workload selected to achieve 60% of submaximal heart rate. RR series were obtained for each individual with a Polar S810i instrument and with an ECG analyzed with a biological signal conditioner. The HRV indices (rMSSD, pNN50, LFnu, HFnu, and LF/HF) were calculated after signal processing and analysis. The unpaired Student t-test and intraclass correlation coefficient were used for data analysis. No statistically significant differences were observed when comparing the values analyzed by means of the two devices for HRV at rest and during exercise. The intraclass correlation coefficient demonstrated satisfactory correlation between the values obtained by the devices at rest (pNN50 = 0.994; rMSSD = 0.995; LFnu = 0.978; HFnu = 0.978; LF/HF = 0.982) and during exercise (pNN50 = 0.869; rMSSD = 0.929; LFnu = 0.973; HFnu = 0.973; LF/HF = 0.942). The calculation of HRV values by means of temporal series obtained from the Polar S810i instrument appears to be as reliable as those obtained by processing the ECG signal captured with a signal conditioner.


Assuntos
Eletrocardiografia/instrumentação , Frequência Cardíaca/fisiologia , Monitorização Fisiológica/instrumentação , Teste de Esforço , Humanos , Masculino , Reprodutibilidade dos Testes , Descanso/fisiologia , Adulto Jovem
5.
Braz. j. med. biol. res ; 41(10): 854-859, Oct. 2008. graf, tab
Artigo em Inglês | LILACS | ID: lil-496800

RESUMO

The aim of the present study was to compare heart rate variability (HRV) at rest and during exercise using a temporal series obtained with the Polar S810i monitor and a signal from a LYNX® signal conditioner (BIO EMG 1000 model) with a channel configured for the acquisition of ECG signals. Fifteen healthy subjects aged 20.9 ± 1.4 years were analyzed. The subjects remained at rest for 20 min and performed exercise for another 20 min with the workload selected to achieve 60 percent of submaximal heart rate. RR series were obtained for each individual with a Polar S810i instrument and with an ECG analyzed with a biological signal conditioner. The HRV indices (rMSSD, pNN50, LFnu, HFnu, and LF/HF) were calculated after signal processing and analysis. The unpaired Student t-test and intraclass correlation coefficient were used for data analysis. No statistically significant differences were observed when comparing the values analyzed by means of the two devices for HRV at rest and during exercise. The intraclass correlation coefficient demonstrated satisfactory correlation between the values obtained by the devices at rest (pNN50 = 0.994; rMSSD = 0.995; LFnu = 0.978; HFnu = 0.978; LF/HF = 0.982) and during exercise (pNN50 = 0.869; rMSSD = 0.929; LFnu = 0.973; HFnu = 0.973; LF/HF = 0.942). The calculation of HRV values by means of temporal series obtained from the Polar S810i instrument appears to be as reliable as those obtained by processing the ECG signal captured with a signal conditioner.


Assuntos
Humanos , Masculino , Adulto Jovem , Eletrocardiografia/instrumentação , Frequência Cardíaca/fisiologia , Monitorização Fisiológica/instrumentação , Teste de Esforço , Reprodutibilidade dos Testes , Descanso/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...