Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pharmacotherapy ; 26(12): 1679-86, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17125431

RESUMO

STUDY OBJECTIVES: To compare the relative bioavailability of enfuvirtide, a human immunodeficiency virus type 1 (HIV-1) fusion inhibitor, injected with the Biojector 2000 (B2000) needle-free device versus a 27-gauge half-inch needle-syringe; and to assess safety, tolerability, and patient preference for the two devices. DESIGN: Open-label, randomized, two-period crossover bioequivalence evaluation. SETTING: Clinical research center. PATIENTS: Twenty-seven adults with HIV-1 viral loads below 1000 copies/ml. INTERVENTION: Each patient received enfuvirtide 90 mg subcutaneously with the B2000 and with the needle-syringe, with a 1-week washout between treatments. MEASUREMENTS AND MAIN RESULTS: Twenty-six and 27 patients were included in the bioequivalence and safety analyses, respectively. Plasma enfuvirtide concentrations were measured at baseline and at several intervals after each injection. The B2000:needle-syringe ratios of maximum concentration (C(max)), area under the concentration-time curve from time zero extrapolated to infinity (AUC(0-infinity)), and AUC from time zero to tau (dosing interval) (AUC(0-tau)) served as criteria for bioequivalence determination. The two drug delivery systems were considered bioequivalent if the 90% confidence intervals (CIs) for the ratios were within 0.8-1.25. Safety and tolerability were evaluated based on documentation of adverse events, graded laboratory toxicities, and local injection-site reactions. Patient surveys provided feedback on device preference. Ratios of C(max), AUC(0-infinity), and AUC(0-tau) were 0.95 (90% CI 0.84-1.09), 0.99 (90% CI 0.93-1.05), and 0.99 (90% CI 0.93-1.05), respectively. The frequency of injection-site reactions was low, and severity was generally mild for both devices. Survey results showed 18 patients (69%) had a positive overall impression of the B2000 and 14 (54%) felt safer injecting with this device. Overall, 17 patients (65%) preferred the B2000 over the needle-syringe. CONCLUSION: Bioavailability of enfuvirtide with the B2000 and needle-syringe was equivalent based on C(max), AUC(0-tau), and AUC(0-infinity). Safety profiles and injection-site reactions were comparable between the devices, but patients preferred the B2000. Delivery of enfuvirtide with the B2000 is a feasible alternative to standard needle administration and warrants further evaluation.


Assuntos
Proteína gp41 do Envelope de HIV/uso terapêutico , Inibidores da Fusão de HIV/farmacocinética , Inibidores da Fusão de HIV/uso terapêutico , Infecções por HIV/tratamento farmacológico , Fragmentos de Peptídeos/farmacocinética , Fragmentos de Peptídeos/uso terapêutico , Área Sob a Curva , Estudos Cross-Over , Enfuvirtida , Feminino , Proteína gp41 do Envelope de HIV/administração & dosagem , Inibidores da Fusão de HIV/administração & dosagem , Humanos , Injeções a Jato , Injeções Subcutâneas , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Fragmentos de Peptídeos/administração & dosagem , Equivalência Terapêutica
2.
Clin Cancer Res ; 10(7): 2327-35, 2004 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-15073108

RESUMO

PURPOSE: Ro 09-4889 was designed to enhance the anticancer efficacy of capecitabine (Xeloda) by generating a dihydropyrimidine dehydrogenase inhibitor (DPDi) 5-vinyluracil (5-VU) preferentially in tumor tissues. This study assessed the tolerance to Ro 09-4889 treatment, and related pharmacokinetic and pharmacodynamic data such as inhibition of DPD activity in peripheral blood mononuclear cells (PBMCs) and plasma uracil levels. EXPERIMENTAL DESIGN: This was a single-center, double-blind, placebo-controlled, single-dose escalation study in 64 healthy male volunteers at 1-, 5-, 20-, 50-, 75-, 100-, and 200-mg oral dose of Ro 09-4889. Also, food effect was assessed separately in a group dosed with 20 mg of the compound. RESULTS: No serious adverse effects or significant laboratory and electrocardiogram abnormalities were observed during the study. Ro 09-4889 has a short elimination half-life (t(1/2)) of 0.5 h, followed by metabolites 5'-deoxy-5-vinyluridine (5'-DVUR), 5'-deoxy-5-vinylcytidine (5'-DVCR), and 5-VU with t(1/2) of 1.3, 1.2, and 2 h, respectively. The major metabolite excreted in urine was 5-DVCR (45% of dose). The inhibition of PBMC DPD activity and the increase in plasma uracil were related to Ro 09-4889 dose. DPD inhibition versus dose and uracil AUC (area under the curve) versus dose were modeled using the E(max) model with a baseline effect. The model-predicted ED(50) value was 100 mg. CONCLUSION: Single oral doses of Ro 09-4889 ranging from 1 to 200 mg were well tolerated. On the basis of these findings, a 10-to-30-mg dose range of Ro 09-4889 combined with capecitabine could be appropriate for further evaluation in cancer patients.


Assuntos
Desoxicitidina/análogos & derivados , Desoxicitidina/farmacologia , Desoxicitidina/farmacocinética , Desoxiuridina/análogos & derivados , Di-Hidrouracila Desidrogenase (NADP)/antagonistas & inibidores , Inibidores Enzimáticos/farmacologia , Inibidores Enzimáticos/farmacocinética , Administração Oral , Antimetabólitos Antineoplásicos/administração & dosagem , Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Área Sob a Curva , Capecitabina , Desoxicitidina/administração & dosagem , Desoxiuridina/farmacologia , Relação Dose-Resposta a Droga , Método Duplo-Cego , Sinergismo Farmacológico , Fluoruracila/análogos & derivados , Humanos , Leucócitos Mononucleares/metabolismo , Masculino , Modelos Químicos , Placebos , Fatores de Tempo , Uracila/sangue , Uracila/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...