Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Image Anal ; 88: 102865, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37331241

RESUMO

Cranial implants are commonly used for surgical repair of craniectomy-induced skull defects. These implants are usually generated offline and may require days to weeks to be available. An automated implant design process combined with onsite manufacturing facilities can guarantee immediate implant availability and avoid secondary intervention. To address this need, the AutoImplant II challenge was organized in conjunction with MICCAI 2021, catering for the unmet clinical and computational requirements of automatic cranial implant design. The first edition of AutoImplant (AutoImplant I, 2020) demonstrated the general capabilities and effectiveness of data-driven approaches, including deep learning, for a skull shape completion task on synthetic defects. The second AutoImplant challenge (i.e., AutoImplant II, 2021) built upon the first by adding real clinical craniectomy cases as well as additional synthetic imaging data. The AutoImplant II challenge consisted of three tracks. Tracks 1 and 3 used skull images with synthetic defects to evaluate the ability of submitted approaches to generate implants that recreate the original skull shape. Track 3 consisted of the data from the first challenge (i.e., 100 cases for training, and 110 for evaluation), and Track 1 provided 570 training and 100 validation cases aimed at evaluating skull shape completion algorithms at diverse defect patterns. Track 2 also made progress over the first challenge by providing 11 clinically defective skulls and evaluating the submitted implant designs on these clinical cases. The submitted designs were evaluated quantitatively against imaging data from post-craniectomy as well as by an experienced neurosurgeon. Submissions to these challenge tasks made substantial progress in addressing issues such as generalizability, computational efficiency, data augmentation, and implant refinement. This paper serves as a comprehensive summary and comparison of the submissions to the AutoImplant II challenge. Codes and models are available at https://github.com/Jianningli/Autoimplant_II.


Assuntos
Próteses e Implantes , Crânio , Humanos , Crânio/diagnóstico por imagem , Crânio/cirurgia , Craniotomia/métodos , Cabeça
2.
J Supercomput ; 79(4): 3643-3665, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36093387

RESUMO

This paper presents a prototype filter design using the orthant optimization technique to assist a filter bank multicarrier (FBMC) modulation scheme of a NextG smart e-healthcare network framework. Low latency and very high reliability are one of the main requirements of a real-time e-healthcare system. In recent times, FBMC modulation has gotten more attention due to its spectral efficiency. The characteristics of a filter bank are determined by t's, prototype filter. A prototype filter cannot be designed to achieve an arbitrary time localization (for low latency) and frequency localization (spectral efficiency), as time and frequency spreading are conflicting goals. Hence, an optimum design needed to be achieved. In this paper, a constraint for perfect or nearly perfect reconstruction is formulated for prototype filter design and an orthant-based enriched sparse ℓ1-optimization method is applied to achieve the optimum performance in terms of higher availability of subcarrier spacing for the given requirement of signal-to-interference ratio. Larger subcarrier spacing ensures lower latency and better performance in real-time applications. The proposed FBMC system, based on an optimum design of the prototype filter, also supports a higher data rate as compared to traditional FBMC and OFDM systems, which is another requirement of real-time communication. In this paper, the solution for the different technical issues of physical layer design is provided. The presented modulation scheme through the proposed prototype filter-based FBMC can suppress the side lobe energy of the constituted filters up to large extent without compromising the recovery of the signal at the receiver end. The proposed system provides very high spectral efficiency; it can sacrifice large guard band frequencies to increase the subcarrier spacing to provide low-latency communication to support the real-time e-healthcare network.

3.
Multimed Tools Appl ; 81(16): 23355-23371, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35317470

RESUMO

This paper presents a low cost, robust, portable and automated cataract detection system which can detect the presence of cataract from the colored digital eye images and grade their severity. Ophthalmologists detect cataract through visual screening using ophthalmoscope and slit lamps. Conventionally a patient has to visit an ophthalmologist for eye screening and treatment follows the course. Developing countries lack the proper health infrastructure and face huge scarcity of trained medical professionals as well as technicians. The condition is not very satisfactory with the rural and remote areas of developed nations. To bridge this barrier between the patient and the availability of resources, current work focuses on the development of portable low-cost, robust cataract screening and grading system. Similar works use fundus and retinal images which use costly imaging modules and image based detection algorithms which use much complex neural network models. Current work derives its benefit from the advancements in digital image processing techniques. A set of preprocessing has been done on the colored eye image and later texture information in form of mean intensity, uniformity, standard deviation and randomness has been calculated and mapped with the diagnostic opinion of doctor for cataract screening of over 200 patients. For different grades of cataract severity edge pixel count was calculated as per doctor's opinion and later these data are used for calculating the thresholds using hybrid k-means algorithm, for giving a decision on the presence of cataract and grade its severity. Low value of uniformity and high value of other texture parameters confirm the presence of cataract as clouding in eye lens causes the uniformity function to take lower value due to presence of coarse texture. Higher the edge pixel count value, this confirms the presence of starting of cataract as solidified regions in lens are nonuniform. Lower value corresponds to fully solidified region or matured cataract. Proposed algorithm was initially developed on MATLAB, and tested on over 300 patients in an eye camp. The system has shown more than 98% accuracy in detection and grading of cataract. Later a cloud based system was developed with 3D printed image acquisition module to manifest an automated, portable and efficient cataract detection system for Tele-Ophthalmology. The proposed system uses a very simple and efficient technique by mapping the diagnostic opinion of the doctor as well, giving very promising results which suggest its potential use in teleophthalmology applications to reduce the cost of delivering eye care services and increasing its reach effectively. Developed system is simple in design and easy to operate and suitable for mass screening of cataracts. Due to non-invasive and non-mydriatic and mountable nature of device, in person screening is not required. Hence, social distancing norms are easy to follow and device is very useful in COVID-19 like situation.

4.
Telemed J E Health ; 23(9): 753-762, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28304241

RESUMO

INTRODUCTION: This article proposes a novel, cost-effective, flexible, and easy-to-deploy wireless teleophthalmology network architecture and performance evaluation for its potential use in remote areas. This study has used practical telecommunication standards, which is widely deployed throughout India. METHODS: In the proposed scenario, patient's eye images are obtained using a specified imaging modality, and then sent to a server at the primary eye care centre (PECC) using ZigBee a short-range wireless network. It is linked to the main server at the base eye hospital (BEH) through a GSM/UMTS (3G)/WiMAX (Worldwide Interoperability for Microwave Access) network. After diagnostic evaluation of the eye image using various automated diagnostic software, data are sent to a physician in an urban center for further validation, which is connected through GSM/UMTS (3G)/WiMAX network. Performance evaluation of these wireless networks is carried out for their use in teleophthalmology application based on network parameters, namely throughput, average end-to-end delay, and average jitter. It is found that end-to-end delay is the most critical network parameter affecting overall quality of service (QoS) of the proposed teleophthalmology network. RESULTS AND CONCLUSIONS: The results demonstrate that WiMAX is the most suitable network among the considered networks for connecting PECC nodes with BEH main server, and further connecting main server with a doctor on the move. It is also deduced that for a given set of QoS parameters, WiMAX supports a load capacity of 22,000 packets at center nodes and the main server and it performs well even when the mobility speed of doctor exceeds 200 KPH.


Assuntos
Oftalmologia/organização & administração , Serviços de Saúde Rural/organização & administração , Telemedicina/organização & administração , Tecnologia sem Fio/organização & administração , Análise Custo-Benefício , Humanos , Índia , Oftalmologia/economia , Serviços de Saúde Rural/economia , Telemedicina/economia , Tecnologia sem Fio/economia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...