Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
Adv Sci (Weinh) ; : e2405251, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38958496

RESUMO

The pursuit of advanced brain-inspired electronic devices and memory technologies has led to explore novel materials by processing multimodal and multilevel tailored conductive properties as the next generation of semiconductor platforms, due to von Neumann architecture limits. Among such materials, antimony sulfide (Sb2S3) thin films exhibit outstanding optical and electronic properties, and therefore, they are ideal for applications such as thin-film solar cells and nonvolatile memory systems. This study investigates the conduction modulation and memory functionalities of Sb2S3 thin films deposited via the vapor transport deposition technique. Experimental results indicate that the Ag/Sb2S3/Pt device possesses properties suitable for memory applications, including low operational voltages, robust endurance, and reliable switching behavior. Further, the reproducibility and stability of these properties across different device batches validate the reliability of these devices for practical implementation. Moreover, Sb2S3-based memristors exhibit artificial neuroplasticity with prolonged stability, promising considerable advancements in neuromorphic computing. Leveraging the photosensitivity of Sb2S3 enables the Ag/Sb2S3/Pt device to exhibit significant low operating potential and conductivity modulation under optical stimulation for memory applications. This research highlights the potential applications of Sb2S3 in future memory devices and optoelectronics and in shaping electronics with versatility.

2.
Cureus ; 16(6): e62869, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39040771

RESUMO

Background The spleen, a key immunological organ, plays a crucial role in filtering aged or damaged red blood cells. Splenomegaly, an enlargement of the spleen, can arise from a variety of physiological and pathological conditions, including hematological disorders, hepatic diseases, and infections. Accurate diagnosis and evaluation of splenomegaly are essential for effective treatment. Objectives The objective of this study was to evaluate splenic stiffness in patients with splenomegaly using point shear wave elastography (pSWE) and compare the findings with those of individuals with normal spleen. Materials and methods This hospital-based observational study was conducted at Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pune, India, from October 2022 to December 2023. The study included 56 participants, divided into two groups: 28 patients with splenomegaly and 28 healthy controls. Spleen stiffness was measured using a Samsung HS70A ultrasound machine (Samsung Electronics Pvt. Ltd., Seoul, South Korea), and pSWE was performed with a curvilinear probe. Data were analyzed using IBM SPSS Statistics for Windows, Version 26.0 (Released 2019; IBM Corp., Armonk, New York, United States), and the significance of differences was assessed using an independent t-test with a p-value of <0.05, considered statistically significant. Results The mean spleen stiffness, measured in kilopascals (kPa), was significantly higher in individuals with splenomegaly (32.05 ± 12.54 kPa) compared to controls (22.9 ± 9.49 kPa) (p = 0.003). A positive correlation (rho = 0.482, p < 0.001) was observed between spleen diameter and spleen stiffness. Conclusion This study demonstrates that pSWE is an effective, non-invasive tool for assessing spleen stiffness. The higher spleen stiffness in splenomegaly patients underscores pSWE's diagnostic utility, with a positive correlation between spleen diameter and stiffness. Further multi-center studies are recommended to validate these findings, highlighting pSWE's promise in evaluating and monitoring splenic disorders.

3.
J Pain Res ; 17: 1773-1784, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38784716

RESUMO

Purpose: Chronic, non-cancer pain significantly and negatively impacts patient quality of life. Neuromodulation is a major component of multi-modal interdisciplinary approaches to chronic pain management, which includes opioid and nonopioid medications. In randomized controlled trials, spinal cord stimulation (SCS) has been shown to reduce pain and decrease short-term opioid use for patients. This study sought to evaluate the effect of SCS on longer term opioid and non-opioid pain medication usage among patients over ≥3 years of follow-up. Patients and Methods: Claims analysis was conducted using the Merative™ MarketScan® Commercial Database. Patients aged ≥18 who initiated SCS between 1/1/2010 and 3/31/2021 with ≥1 year of baseline data and ≥3 years of follow-up data were included. Opioid discontinuation, daily dose (DD) reduction, proportion of days covered (PDC), concomitant co-medication with benzodiazepines and/or gabapentinoids, and polypharmacy were evaluated during the baseline and follow-up periods. Adjusted logistic regression was used to evaluate the impact of baseline dosages on discontinuation and dose reduction. Results: During follow-up, 60% of 2,669 SCS patients either discontinued opioid use or reduced opioid DD by at least 20% from baseline; another 15% reduced DD by 1-19%. Logistic regression showed patients with higher baseline dosages were less likely to discontinue opioids completely (odds ratio[OR] 95% confidence intervals[CI]: 0.31[0.18,0.54]) but more likely to reduce their daily dose (OR[CI]: 7.14[4.00,12.73], p<0.001). Mean PDC with opioids decreased from 0.58 (210 of 365 days) at baseline to 0.51 at year 3 (p<0.001). With SCS, co-medication with benzodiazepines decreased from 47.3% at baseline to 30.3% at year 3, co-medication with gabapentinoids reduced from 58.6% to 42.2%, and polypharmacy dropped from 15.6% to 9.6% (all p<0.001). Conclusion: Approximately three-quarters of patients who received SCS therapy either discontinued or reduced systemic opioid use over the study period. SCS could assist in reducing long-term reliance on opioids and other pain medications to treat chronic non-cancer pain.

4.
J Educ Health Promot ; 13: 137, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38784258

RESUMO

BACKGROUND: Smartphones have become an indispensable part of almost everyone's life. India has now become the leading and second-largest Smartphone market in the world. It has been noted that the purpose of Smartphone usage has exceptionally changed over the past few years, especially among students, professionals, and the common man. Smartphones have now become essential and the need of the hour, and medical students are no exception. Smartphones can make "smart students smarter"! There are now 10,275 unique applications labeled under the "Medical" and "Healthcare and Fitness" categories. The common medical applications used are MedCalc, Drug Infusion, Flashcards, Encyclopedia, Merck Manual, Medscape, PubMed, Epocrates, MedlinePlus, Lab test applications, Medical Dictionary, Eponyms etc. Despite the advantages and needs of smartphones, they have proven to be a source of potential hazard to human health, not only physical but also mental, social, and emotional well-being. There is consistent evidence for co-morbidity (such as obesity, heart diseases, neck and back pain, etc.) between excessive smartphone use and other psychiatric disorders, such as depression, anxiety, obsessive and compulsive disorder (OCD), and attention deficit hyperactivity disorder (ADHD) similar to internet addiction. The significant association of this addiction with poorer sleep quality and higher perceived stress has been a cause for concern. Hence, further investigation to explore the association between smartphone addiction and mental health, this study was undertaken. MATERIALS AND METHODS: Our study was undertaken in Dr VMGMC, Solapur, from June to August 2022, after obtaining approval from the ethical committee, approval number 172/22. Total voluntary participation for the study was 600 (from first to final year), and accordingly convenient sample size was taken. RESULTS: We found that out of the total participants, 42% of the participants had an average screen time of 4-6 h daily. A very small percentage of participants (4%) spent less than two hours in front of a screen. Alarmingly, 65% of the participants had an average screen time of more than 4 hours, which puts them at risk for the negative health impacts of prolonged screen time. Around 12% of them had symptoms of mild stress, 10.3% for mild anxiety, and 15.6% for mild depression. 10.6% had symptoms of moderate stress, 23.3% for moderate anxiety, and 16% for moderate depression. A small proportion of undergraduates, that is, 5%, 16%, and 11.6%, had symptoms of severe and extremely severe stress, anxiety, and depression, respectively. CONCLUSION: The study participants did not feel a lot of stress, anxiety, or depression symptoms when smartphones were used judiciously and mostly for non-social purposes (such as studying, listening to music, or watching videos). This investigation led us to the conclusion that there are some positive effects of smartphones on mental health. However, those who spent an excessive amount of time on their smartphones for social contact, with an average screen time of 5 h, showed signs of mild to moderate sadness, moderate anxiety, and tension, demonstrating that social media had a negative impact on the mental health of medical undergraduates. Therefore, efforts should be made to inform medical students about how using a smartphone is harming their mental health.

5.
bioRxiv ; 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38496403

RESUMO

Brain-machine interfaces (BMI) aim to restore function to persons living with spinal cord injuries by 'decoding' neural signals into behavior. Recently, nonlinear BMI decoders have outperformed previous state-of-the-art linear decoders, but few studies have investigated what specific improvements these nonlinear approaches provide. In this study, we compare how temporally convolved feedforward neural networks (tcFNNs) and linear approaches predict individuated finger movements in open and closed-loop settings. We show that nonlinear decoders generate more naturalistic movements, producing distributions of velocities 85.3% closer to true hand control than linear decoders. Addressing concerns that neural networks may come to inconsistent solutions, we find that regularization techniques improve the consistency of tcFNN convergence by 194.6%, along with improving average performance, and training speed. Finally, we show that tcFNN can leverage training data from multiple task variations to improve generalization. The results of this study show that nonlinear methods produce more naturalistic movements and show potential for generalizing over less constrained tasks. Teaser: A neural network decoder produces consistent naturalistic movements and shows potential for real-world generalization through task variations.

7.
IEEE Trans Biomed Eng ; 71(6): 1993-2000, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38277250

RESUMO

OBJECTIVE: Deep brain stimulation (DBS) modeling can improve surgical targeting by quantifying the spatial extent of stimulation relative to subcortical structures of interest. A certain degree of model complexity is required to obtain accurate predictions, particularly complexity regarding electrical properties of the tissue around DBS electrodes. In this study, the effect of anisotropy on the volume of tissue activation (VTA) was evaluated in an individualized manner. METHODS: Tissue activation models incorporating patient-specific tissue conductivity were built for 40 Parkinson disease patients who had received bilateral subthalamic nucleus (STN) DBS. To assess the impact of local changes in tissue anisotropy, one VTA was computed at each electrode contact using identical stimulation parameters. For comparison, VTAs were also computed assuming isotropic tissue conductivity. Stimulation location was considered by classifying the anisotropic VTAs relative to the STN. VTAs were characterized based on volume, spread in three directions, sphericity, and Dice coefficient. RESULTS: Incorporating anisotropy generated significantly larger and less spherical VTAs overall. However, its effect on VTA size and shape was variable and more nuanced at the individual patient and implantation levels. Dorsal VTAs had significantly higher sphericity than ventral VTAs, suggesting more isotropic behavior. Contrastingly, lateral and posterior VTAs had significantly larger and smaller lateral-medial spreads, respectively. Volume and spread correlated negatively with sphericity. CONCLUSION: The influence of anisotropy on VTA predictions is important to consider, and varies across patients and stimulation location. SIGNIFICANCE: This study highlights the importance of considering individualized factors in DBS modeling to accurately characterize the VTA.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Humanos , Estimulação Encefálica Profunda/métodos , Doença de Parkinson/terapia , Doença de Parkinson/fisiopatologia , Anisotropia , Masculino , Pessoa de Meia-Idade , Feminino , Idoso , Modelos Neurológicos , Núcleo Subtalâmico/fisiopatologia , Encéfalo/diagnóstico por imagem , Encéfalo/fisiopatologia , Condutividade Elétrica
10.
J Neurosurg ; 140(3): 657-664, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37773878

RESUMO

OBJECTIVE: The effect of subthalamic nucleus (STN) deep brain stimulation (DBS) on urinary dysfunction and constipation in Parkinson's disease (PD) is variable. This study aimed to identify potential surgical and nonsurgical variables predictive of these outcomes. METHODS: The authors used the Movement Disorder Society-Unified Parkinson's Disease Rating Scale (MDS-UPDRS) Part I to assess urinary dysfunction (item 10) and constipation (item 11) preoperatively and at 6-12 months postoperatively. A multiple linear regression model was used to investigate the impact of global cerebral atrophy (GCA) and active electrode contact location on the urinary dysfunction and constipation follow-up scores, controlling for age, disease duration, baseline score, motor improvement, and levodopa-equivalent dose changes. An electric field model was applied to localize the maximal-effect sites for constipation and urinary dysfunction compared with those for motor improvement. RESULTS: Among 74 patients, 23 improved, 28 deteriorated, and 23 remained unchanged for urinary dysfunction; 25 improved, 15 deteriorated, and 34 remained unchanged for constipation. GCA score and age significantly predicted urinary dysfunction follow-up score (R2 = 0.36, p < 0.001). Increased GCA and age were independently associated with worsening urinary symptoms. Disease duration, baseline constipation score, and anterior active electrode contacts in both hemispheres were significant predictors of constipation follow-up score (R2 = 0.31, p < 0.001). Higher baseline constipation score and disease duration were associated with worsening constipation; anterior active contact location was associated with improvement in constipation. CONCLUSIONS: Anterior active contact location was associated with improvement in constipation in PD patients after STN DBS. PD patients with greater GCA scores before surgery were more likely to experience urinary deterioration after DBS.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Núcleo Subtalâmico , Humanos , Doença de Parkinson/complicações , Doença de Parkinson/terapia , Resultado do Tratamento , Estimulação Encefálica Profunda/efeitos adversos , Constipação Intestinal/terapia , Constipação Intestinal/complicações
12.
Artigo em Inglês | MEDLINE | ID: mdl-38145529

RESUMO

Individuals with upper limb loss lack sensation of the missing hand, which can negatively impact their daily function. Several groups have attempted to restore this sensation through electrical stimulation of residual nerves. The purpose of this study was to explore the utility of regenerative peripheral nerve interfaces (RPNIs) in eliciting referred sensation. In four participants with upper limb loss, we characterized the quality and location of sensation elicited through electrical stimulation of RPNIs over time. We also measured functional stimulation ranges (sensory perception and discomfort thresholds), sensitivity to changes in stimulation amplitude, and ability to differentiate objects of different stiffness and sizes. Over a period of up to 54 months, stimulation of RPNIs elicited sensations that were consistent in quality (e.g. tingling, kinesthesia) and were perceived in the missing hand and forearm. The location of elicited sensation was partially-stable to stable in 13 of 14 RPNIs. For 5 of 7 RPNIs tested, participants demonstrated a sensitivity to changes in stimulation amplitude, with an average just noticeable difference of 45 nC. In a case study, one participant was provided RPNI stimulation proportional to prosthetic grip force. She identified four objects of different sizes and stiffness with 56% accuracy with stimulation alone and 100% accuracy when stimulation was combined with visual feedback of hand position. Collectively, these experiments suggest that RPNIs have the potential to be used in future bi-directional prosthetic systems.


Assuntos
Membros Artificiais , Nervos Periféricos , Feminino , Humanos , Nervos Periféricos/fisiologia , Extremidade Superior , Sensação , Mãos , Estimulação Elétrica
13.
J Rheum Dis ; 31(1): 15-24, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38130958

RESUMO

Objective: This study was conducted to investigate the immunological and clinical response to COVID-19 vaccination in rheumatoid arthritis (RA) patients receiving disease modifying antirheumatic drugs (DMARDs). Methods: A cross-sectional study was conducted among RA patients who received two doses of COVID-19 vaccine within 6 months to one year. Demographic information, comorbidities, vaccination details, and past COVID-19 infection details were collected. Hemoglobin (Hb), erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and interleukin-6 (IL-6) levels were estimated. Disease Activity Score-28 (DAS-28) was calculated for RA patients. Anti-spike antibody (ASA) concentrations were measured, and compared with a healthy control population. Correlations of ASA with age, sex, disease parameters, medication use, and comorbidities were assessed. Results: A total of 103 RA patients and 185 controls were included in the study. RA patients had higher mean age, lower mean Hb, higher ESR, and elevated IL-6 levels. Both groups showed positive results for anti-spike antibodies, with a higher percentage in controls. Among RA patients majority had low DAS-28 score. The number of DMARDs used showed a negative correlation with antibody levels. There was a slight positive correlation between ASA concentration and DAS-28 score. Comorbidities did not significantly influence antibody concentration. No significant differences were found in antibody levels based on the type of COVID-19 vaccine or previous COVID-19 infection or booster dose vaccination among RA patients. Conclusion: The study revealed that RA patients showed a reduced antibody response following COVID-19 vaccination compared to the control group and potentially influenced by immunosuppressive treatments and disease-related factors.

14.
Nanotechnology ; 35(9)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-37995371

RESUMO

External hemostatic agents play a crucial role in stabilizing an impaired process during pathological conditions. The idea is to stabilize thein vivosystem as soon as possible. This study uses a class I hemostatic drug tranexamic acid as a reducing and capping agent for synthesizing the gold nanoparticles (Tr-AuNPs). Being the synthetic analogue of lysine and a biologically inspired alkylamine molecule, the chemistry can be fine-tuned for stable material that can simultaneously target the intrinsic and extrinsic hemostatic pathway, making it promising for hemostatic applications. The Tr-AuNPs of hydrodynamic diameter ∼46 nm were synthesized and evaluated physio-chemically using various analytical techniques wherein they showed hemocompatibility and increased thrombus weight compared to the native drug. The decrease in prothrombin time (PT) and international normalized ratio supported by the dynamic thromboelastography (TEG) study indicates the prepared nano-conjugate's potential in reducing time for attaining hemostasis as compared to the native tranexamic acid drug. At a 9µg ml-1concentration, Tr-AuNPs had a procoagulant effect, shown by decreased reaction time (R) and coagulation time (K) with improvedαangle and MA. There was a significant increase in the rate of coagulationin vivoby Tr-AuNPs, i.e. (52 s) compared to the native tranexamic acid (360 s). Radiolabelling studies ascertained thein vivobiocompatibility (non-invasive distribution, residence, clearance, and stability) of the Tr-AuNPs. The short-term toxicity studies were conducted to establish a proof of concept for the biomedical application of the material. The results highlighted the use of biologically alkyl amine molecules as capping and reducing agents for the synthesis of nanoparticles, which have shown a synergistic effect on the coagulation cascade while holding the potential for also acting as potential theranostic agents.


Assuntos
Hemostáticos , Nanopartículas Metálicas , Ácido Tranexâmico , Ouro/farmacologia , Ouro/química , Ácido Tranexâmico/farmacologia , Nanopartículas Metálicas/química
15.
Cureus ; 15(8): e43323, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37700974

RESUMO

INTRODUCTION: Phlebotomy, i.e., the collection of blood samples, is one of the most commonly performed procedures in almost all hospital settings. The phlebotomy center is the first point of contact for patient samples with the laboratory services. The patient load visiting the phlebotomy center of a rapidly developing hospital is very variable and unpredictable. This leads to staffing issues related to a number of phlebotomists. The actual phlebotomy procedure requires only a few minutes, but the total time includes the patient's arrival to departure from the phlebotomy center. In this study, we have attempted to assess the adequacy of the number of phlebotomists in our sample collection center and to determine how many patients can be attended to comfortably by each phlebotomist. As the sample load increases, the burden on phlebotomists also increases, and they may or may not express the strain of it. We attempted to determine the cut-off patient numbers above which request for additional personnel has to be put into the hospital administration. MATERIALS AND METHODS: This was a prospective, hospital-based, observational study carried out in the outpatient sample collection center section at the All India Institute of Medical Sciences, Bibinagar, Telangana, over a period of one month, i.e., December 2022. The movement of 1200 patients was observed for the phlebotomy procedure. Patient details, the time taken for registration, waiting time, and phlebotomy time were noted, along with the hindering factors in the phlebotomy center. OBSERVATIONS AND RESULTS: There were 680 males and 520 females. The mean time for patient arrival to departure from the phlebotomy center and the mean waiting time was 9.8 minutes and 6.5 minutes, respectively. Various reasons for increased phlebotomy time were pediatric patients, anxious patients, postprandial sample patients, difficulty in finding veins, etc. Though the estimated capacity of the phlebotomy center is apparently satisfactory with four personnel, many hidden causes for time loss were observed.  Conclusion: An adequate number of trained and effective phlebotomists is the first step in ensuring the success of any laboratory service, and while deciding on this "adequate number," not only the direct effort, but also the indirect effort, operational needs and emergencies have to be kept in mind. Each phlebotomist in a six-hour shift can comfortably attend 30 to 35 outpatients for phlebotomy. When this number exceeds it, additional staff has to be added. Adopting measures to reduce the waiting time for phlebotomy procedures will improve the phlebotomy center's service. The study provides a basis for the modification of a number of phlebotomists in order to ensure optimal patient service.

16.
Front Pain Res (Lausanne) ; 4: 1240379, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37663307

RESUMO

Introduction: Inconsistent effects of subthalamic deep brain stimulation (STN DBS) on pain, a common non-motor symptom of Parkinson's disease (PD), may be due to variations in active contact location relative to some pain-reducing locus of stimulation. This study models and compares the loci of maximal effect for pain reduction and motor improvement in STN DBS. Methods: We measured Movement Disorder Society Unified PD Rating Scale (MDS-UPDRS) Part I pain score (item-9), and MDS-UPDRS Part III motor score, preoperatively and 6-12 months after STN DBS. An ordinary least-squares regression model was used to examine active contact location as a predictor of follow-up pain score while controlling for baseline pain, age, dopaminergic medication, and motor improvement. An atlas-independent isotropic electric field model was applied to distinguish sites of maximally effective stimulation for pain and motor improvement. Results: In 74 PD patients, mean pain score significantly improved after STN DBS (p = 0.01). In a regression model, more dorsal active contact location was the only significant predictor of pain improvement (R2 = 0.17, p = 0.03). The stimulation locus for maximal pain improvement was lateral, anterior, and dorsal to that for maximal motor improvement. Conclusion: STN stimulation, dorsal to the site of optimal motor improvement, improves pain. This region contains the zona incerta, which is known to modulate pain in humans, and may explain this observation.

17.
J Neural Eng ; 20(4)2023 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-37567222

RESUMO

Objective.While brain-machine interfaces (BMIs) are promising technologies that could provide direct pathways for controlling the external world and thus regaining motor capabilities, their effectiveness is hampered by decoding errors. Previous research has demonstrated the detection and correction of BMI outcome errors, which occur at the end of trials. Here we focus on continuous detection and correction of BMI execution errors, which occur during real-time movements.Approach.Two adult male rhesus macaques were implanted with Utah arrays in the motor cortex. The monkeys performed single or two-finger group BMI tasks where a Kalman filter decoded binned spiking-band power into intended finger kinematics. Neural activity was analyzed to determine how it depends not only on the kinematics of the fingers, but also on the distance of each finger-group to its target. We developed a method to detect erroneous movements, i.e. consistent movements away from the target, from the same neural activity used by the Kalman filter. Detected errors were corrected by a simple stopping strategy, and the effect on performance was evaluated.Mainresults.First we show that including distance to target explains significantly more variance of the recorded neural activity. Then, for the first time, we demonstrate that neural activity in motor cortex can be used to detect execution errors during BMI controlled movements. Keeping false positive rate below5%, it was possible to achieve mean true positive rate of28.1%online. Despite requiring 200 ms to detect and react to suspected errors, we were able to achieve a significant improvement in task performance via reduced orbiting time of one finger group.Significance.Neural activity recorded in motor cortex for BMI control can be used to detect and correct BMI errors and thus to improve performance. Further improvements may be obtained by enhancing classification and correction strategies.


Assuntos
Interfaces Cérebro-Computador , Animais , Masculino , Macaca mulatta , Eletrodos Implantados , Dedos , Movimento
18.
Cureus ; 15(6): e40023, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37425605

RESUMO

OBJECTIVE: We aim to find the time in which a thawed citrate plasma sample that was preserved can be analyzed for routine coagulation testing without losing precision. METHODS: Whole blood samples from 30 healthy volunteers were collected in 3.2% sodium citrate vacutainer and centrifuged to separate platelet-poor plasma. Each sample was then aliquoted, one aliquot was used immediately for prothrombin time (PT)-international normalized ratio (INR) and activated partial thromboplastin time (APTT), four were stored at -20°C, and four were stored at -80°C for 24 hours. After 24 hours, the aliquots were taken out and thawed at 37°C in water bath and analyzed after 15, 30, 60, and 120 minutes. STATISTICAL ANALYSIS: Data were presented as mean with standard deviation (SD). Repeated measures ANOVA with Tukey post-hoc test was performed for multiple comparisons. All analysis was done using GraphPAD Prism 8.0 software (GraphPad Software, San Diego, California, USA).  Results: In the case of PT and INR, no statistically significant difference was found between the mean values after thawing for 120 minutes when compared with the mean baseline value. However, the APTT showed a statistically significant difference (p = 0.0232) after 30 minutes of thawing when the sample was stored at -20°C. Furthermore, a statistically significance difference (p = 0.0001) was found after 60 minutes of thawing when the samples were stored at -80°C. CONCLUSION: Plasma samples for the PT and INR may be accepted for assessment up to 120 minutes, when stored at -20°C and -80°C for 24 hours. In the case of APTT, the plasma sample can be used for assessment up to 30 minutes after thawing when stored at -20°C and up to 60 minutes when stored at -80°C.

19.
Elife ; 122023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37284744

RESUMO

A key factor in the clinical translation of brain-machine interfaces (BMIs) for restoring hand motor function will be their robustness to changes in a task. With functional electrical stimulation (FES) for example, the patient's own hand will be used to produce a wide range of forces in otherwise similar movements. To investigate the impact of task changes on BMI performance, we trained two rhesus macaques to control a virtual hand with their physical hand while we added springs to each finger group (index or middle-ring-small) or altered their wrist posture. Using simultaneously recorded intracortical neural activity, finger positions, and electromyography, we found that decoders trained in one context did not generalize well to other contexts, leading to significant increases in prediction error, especially for muscle activations. However, with respect to online BMI control of the virtual hand, changing either the decoder training task context or the hand's physical context during online control had little effect on online performance. We explain this dichotomy by showing that the structure of neural population activity remained similar in new contexts, which could allow for fast adjustment online. Additionally, we found that neural activity shifted trajectories proportional to the required muscle activation in new contexts. This shift in neural activity possibly explains biases to off-context kinematic predictions and suggests a feature that could help predict different magnitude muscle activations while producing similar kinematics.


Assuntos
Interfaces Cérebro-Computador , Animais , Macaca mulatta , Dedos/fisiologia , Movimento/fisiologia , Mãos/fisiologia , Eletromiografia/métodos
20.
bioRxiv ; 2023 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-37292755

RESUMO

Brain-machine interfaces (BMIs) can restore motor function to people with paralysis but are currently limited by the accuracy of real-time decoding algorithms. Recurrent neural networks (RNNs) using modern training techniques have shown promise in accurately predicting movements from neural signals but have yet to be rigorously evaluated against other decoding algorithms in a closed-loop setting. Here we compared RNNs to other neural network architectures in real-time, continuous decoding of finger movements using intracortical signals from nonhuman primates. Across one and two finger online tasks, LSTMs (a type of RNN) outperformed convolutional and transformer-based neural networks, averaging 18% higher throughput than the convolution network. On simplified tasks with a reduced movement set, RNN decoders were allowed to memorize movement patterns and matched able-bodied control. Performance gradually dropped as the number of distinct movements increased but did not go below fully continuous decoder performance. Finally, in a two-finger task where one degree-of-freedom had poor input signals, we recovered functional control using RNNs trained to act both like a movement classifier and continuous decoder. Our results suggest that RNNs can enable functional real-time BMI control by learning and generating accurate movement patterns.

SELEÇÃO DE REFERÊNCIAS