Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Invest Radiol ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38709665

RESUMO

RATIONALE AND OBJECTIVES: This study investigates the performance of tomosynthesis in the presence of osteosynthetic implants, aiming to overcome superimposition-induced limitations in conventional radiograms. MATERIALS AND METHODS: After surgical fracture induction and subsequent osteosynthesis, 8 cadaveric fracture models (wrist, metacarpus, ankle, metatarsus) were scanned with the prototypical tomosynthesis mode of a multiuse x-ray system. Tomosynthesis protocols at 60, 80, and 116 kV (sweep angle 10°, 13 FPS) were compared with standard radiograms. Five radiologists independently rated diagnostic assessability based on an equidistant 7-point scale focusing on fracture delineation, intra-articular screw placement, and implant positioning. The intraclass correlation coefficient (ICC) was calculated to analyze interrater agreement. RESULTS: Radiation dose in radiography was 0.48 ± 0.26 dGy·cm2 versus 0.12 ± 0.01, 0.36 ± 0.02, and 1.95 ± 0.11 dGy·cm2 for tomosynthesis scans at 60, 80, and 116 kV. Delineation of fracture lines was superior for 80/116 kV tomosynthesis compared with radiograms (P ≤ 0.003). Assessability of intra-articular screw placement was deemed favorable for all tomosynthesis protocols (P ≤ 0.004), whereas superiority for evaluation of implant positioning could not be ascertained (all P's ≥ 0.599). Diagnostic confidence was higher for 80/116 kV tomosynthesis versus radiograms and 60 kV tomosynthesis (P ≤ 0.002). Interrater agreement was good for fracture delineation (ICC, 0.803; 95% confidence interval [CI], 0.598-0.904), intra-articular screw placement (ICC, 0.802; 95% CI, 0.599-0.903), implant positioning (ICC, 0.855; 95% CI, 0.729-0.926), and diagnostic confidence (ICC, 0.842; 95% CI, 0.556-0.934). CONCLUSIONS: In the postoperative workup of extremity fractures, tomosynthesis allows for superior assessment of fracture lines and intra-articular screw positioning with greater diagnostic confidence at radiation doses comparable to conventional radiograms.

2.
Arch Orthop Trauma Surg ; 143(10): 6251-6259, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37460845

RESUMO

INTRODUCTION: Proximal ulna fractures with a large zone of comminution, such as in the context of Monteggia injuries, require mechanically strong osteosyntheses as they occur in regions with high physiological joint load. Consequently, implant failure and pseudarthrosis are critical and devastating complications, especially with the background of mainly young patients being affected. An effective solution could be provided by adding a small second plate 90° angulated to the standard dorsal plate in the area of non-union. Thus, this study investigates whether, from a biomechanical point of view, the use of such a mini or baby plate is worthwhile. MATERIALS AND METHODS: Comminuted fractures distal to the coronoid process, equivalent to Jupiter type IIb fractures, are generated on artificial Sawbones® of the ulna and stabilized using two different plate osteosyntheses: in the first group, a dorsal locking compression olecranon plate is used (LCP group). In the second group, a small, ulnar 5-hole olecranon plate is added as a baby plate in addition to the mother plate at the level of the fracture zone (MBP group). Dynamic biomechanical loading in degrees of flexion from 0° to 90° is carried out to determine yield load, stiffness, displacement, and changes in fracture gap width as well as bending of the dorsal plate. RESULTS: The "mother-baby-plate" osteosynthesis had a significantly higher yield load (p < 0.01) and stiffness (p = 0.01) than the LCP group. This correlates with the increased movement of the proximal fracture element during cyclic testing for the LCP group compared to the MBP group as measured by an optical metrology system. CONCLUSIONS: Here, we show evidence that the addition of a small plate to the standard plate is highly effective in increasing the biomechanical stability in severe fractures equivalent to Jupiter type IIb. As it hopefully minimizes complications like pseudarthrosis and implant failure and as the additional preparatory effort leading to compromised blood supply is regarded to be negligible, this justifies and highly advises the use of a mother-baby-plate system.


Assuntos
Fraturas Cominutivas , Pseudoartrose , Fraturas da Ulna , Feminino , Humanos , Mães , Fraturas da Ulna/cirurgia , Ulna , Placas Ósseas , Fixação Interna de Fraturas , Fraturas Cominutivas/cirurgia , Fenômenos Biomecânicos
3.
Diagnostics (Basel) ; 13(10)2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37238160

RESUMO

In this study, the impact of reconstruction sharpness on the visualization of the appendicular skeleton in ultrahigh-resolution (UHR) photon-counting detector (PCD) CT was investigated. Sixteen cadaveric extremities (eight fractured) were examined with a standardized 120 kVp scan protocol (CTDIvol 10 mGy). Images were reconstructed with the sharpest non-UHR kernel (Br76) and all available UHR kernels (Br80 to Br96). Seven radiologists evaluated image quality and fracture assessability. Interrater agreement was assessed with the intraclass correlation coefficient. For quantitative comparisons, signal-to-noise-ratios (SNRs) were calculated. Subjective image quality was best for Br84 (median 1, interquartile range 1-3; p ≤ 0.003). Regarding fracture assessability, no significant difference was ascertained between Br76, Br80 and Br84 (p > 0.999), with inferior ratings for all sharper kernels (p < 0.001). Interrater agreement for image quality (0.795, 0.732-0.848; p < 0.001) and fracture assessability (0.880; 0.842-0.911; p < 0.001) was good. SNR was highest for Br76 (3.4, 3.0-3.9) with no significant difference to Br80 and Br84 (p > 0.999). Br76 and Br80 produced higher SNRs than all kernels sharper than Br84 (p ≤ 0.026). In conclusion, PCD-CT reconstructions with a moderate UHR kernel offer superior image quality for visualizing the appendicular skeleton. Fracture assessability benefits from sharp non-UHR and moderate UHR kernels, while ultra-sharp reconstructions incur augmented image noise.

4.
Cell Rep ; 40(12): 111382, 2022 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-36130490

RESUMO

Rab3A-interacting molecule (RIM) is crucial for fast Ca2+-triggered synaptic vesicle (SV) release in presynaptic active zones (AZs). We investigated hippocampal giant mossy fiber bouton (MFB) AZ architecture in 3D using electron tomography of rapid cryo-immobilized acute brain slices in RIM1α-/- and wild-type mice. In RIM1α-/-, AZs are larger with increased synaptic cleft widths and a 3-fold reduced number of tightly docked SVs (0-2 nm). The distance of tightly docked SVs to the AZ center is increased from 110 to 195 nm, and the width of their electron-dense material between outer SV membrane and AZ membrane is reduced. Furthermore, the SV pool in RIM1α-/- is more heterogeneous. Thus, RIM1α, besides its role in tight SV docking, is crucial for synaptic architecture and vesicle pool organization in MFBs.


Assuntos
Sinapses , Vesículas Sinápticas , Animais , Camundongos , Fibras Musgosas Hipocampais/ultraestrutura , Terminações Pré-Sinápticas/ultraestrutura , Sinapses/ultraestrutura , Transmissão Sináptica , Vesículas Sinápticas/ultraestrutura
5.
Sci Rep ; 12(1): 14422, 2022 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-36002544

RESUMO

Modern cone-beam CT systems are capable of ultra-high-resolution 3D imaging in addition to conventional radiography and fluoroscopy. The combination of various imaging functions in a multi-use setup is particularly appealing for musculoskeletal interventions, such as CBCT arthrography (CBCTA). With this study, we aimed to investigate the feasibility of CBCTA of the wrist in a "one-stop-shop" approach with a gantry-free twin robotic scanner that does not require repositioning of subjects. Additionally, the image quality of CBCTA was compared to subsequent arthrograms on a high-end multidetector CT (MDCTA). Fourteen cadaveric wrists received CBCTA with four acquisition protocols. Specimens were then transferred to the CT suite for additional MDCTA. Dose indices ranged between 14.3 mGy (120 kVp/100 effective mAs; full-dose) and 1.0 mGy (70 kVp/41 effective mAs; ultra-low-dose) for MDCTA and between 17.4 mGy (80 kVp/2.5 mAs per pulse; full-dose) and 1.2 mGy (60 kVp/0.5 mAs per pulse; ultra-low-dose) for CBCTA. Subjective image quality assessment for bone, cartilage and ligamentous tissue was performed by seven radiologists. The interrater reliability was assessed by calculation of the intraclass correlation coefficient (ICC) based on a two-way random effects model. Overall image quality of most CBCTA was deemed suitable for diagnostic use in contrast to a considerable amount of non-diagnostic MDCTA examinations (38.8%). The depiction of bone, cartilage and ligaments in MDCTA with any form of dose reduction was inferior to any CBCTA scan with at least 0.6 mAs per pulse (all p < 0.001). Full-dose MDCTA and low-dose CBCTA were of equal quality for bone tissue visualization (p = 0.326), whereas CBCTA allowed for better depiction of ligaments and cartilage (both p < 0.001), despite merely one third of radiation exposure (MDCTA-14.3 mGy vs. CBCTA-4.5 mGy). Moderate to good interrater reliability was ascertained for the assessment all tissues (ICC 0.689-0.756). Overall median examination time for CBCTA was 5.4 min (4.8-7.2 min). This work demonstrates that substantial dose reduction can be achieved in CT arthrography of the wrist while maintaining diagnostic image quality by employing the cone-beam CT mode of a twin robotic X-ray system. The ability of the multi-use X-ray system to switch between fluoroscopy mode and 3D imaging allows for "one-stop-shop" CBCTA in minimal examination time without the need for repositioning.


Assuntos
Artrografia , Punho , Tomografia Computadorizada de Feixe Cônico/métodos , Reposicionamento de Medicamentos , Humanos , Tomografia Computadorizada Multidetectores , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes , Punho/diagnóstico por imagem
6.
J Mech Behav Biomed Mater ; 128: 105096, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35124352

RESUMO

BACKGROUND: Suture anchors have a large field of application in orthopedic trauma surgery like the refixation of patellar, quadriceps and Achilles tendon or the treatment of rotator cuff tears. The fixation of suture anchors in osteoporotic bone is difficult, a problem that becomes increasingly relevant in the elderly. METHODS: Two types of suture anchors: 1.) Titanium CorkScrew Fast Track II with a knotted eyelet and 2.) polyether ether ketone (PEEK) SwiveLock C with a knotless eyelet were chosen for evaluation in open cell bone blocks with densities of 5-20 pcf supplied by Sawbones AB. A pilot hole of 7 mm diameter and 20 mm depth was drilled in the bone blocks and filled with an experimental drillable magnesium phosphate cement (powder: 92.5 wt% Mg3(PO4)2, 7.5 wt% MgO, liquid: 25 wt% phytic acid (C6H18O24P6)). Anchors were then inserted into the cement and allowed to cure for 24 h (37 °C, 100% humidity) before pullout testing was conducted with a material testing machine. Suture anchors inserted in the blocks after predrilling and tapping served as control. RESULTS: Through augmentation with magnesium phosphate cement pullout strength and stiffness of the suture anchors could be significantly increased in all bone blocks up to 22-fold. CorkScrew anchors failed by rupture of the eyelet with higher pullout strengths, whereas no failure of SwiveLock C anchors could be observed when reinforced with additional FibreWire at the tip. CONCLUSIONS: We present a simple technique, whereby pullout strength of suture anchors can be significantly increased in bone with compromised density. The experimental resorbable and drillable magnesium phosphate cement proved to be effective in resisting tensile load, dispersing in the adjacent bone, and thus increasing the bone-anchor contact surface. Therefore, the experimental magnesium phosphate cement is a promising candidate for clinical application in the numerous scenarios mentioned.


Assuntos
Manguito Rotador , Âncoras de Sutura , Idoso , Fenômenos Biomecânicos , Humanos , Compostos de Magnésio , Fosfatos , Manguito Rotador/cirurgia , Técnicas de Sutura
7.
Materials (Basel) ; 12(9)2019 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-31035473

RESUMO

(1) Background: Bone substitutes are essential in orthopaedic surgery to fill up large bone defects. Thus, the aim of the study was to compare diverse bone fillers biomechanically to each other in a clinical-relevant test set-up and to detect differences in stability and handling for clinical use. (2) Methods: This study combined compressive strength tests and screw pullout-tests with dynamic tests of bone substitutes in a clinical-relevant biomechanical fracture model. Beyond well-established bone fillers (ChronOSTM Inject and Graftys® Quickset), two newly designed bone substitutes, a magnesium phosphate cement (MPC) and a drillable hydrogel reinforced calcium phosphate cement (CPC), were investigated. (3) Results: The drillable CPC revealed a comparable displacement of the fracture and maximum load to its commercial counterpart (Graftys® Quickset) in the clinically relevant biomechanical model, even though compressive strength and screw pullout force were higher using Graftys®. (4) Conclusions: The in-house-prepared cement allowed unproblematic drilling after replenishment without a negative influence on the stability. A new, promising bone substitute is the MPC, which showed the best overall results of all four cement types in the pure material tests (highest compressive strength and screw pullout force) as well as in the clinically relevant fracture model (lowest displacement and highest maximum load). The low viscosity enabled a very effective interdigitation to the spongiosa and a complete filling up of the defect, resulting in this demonstrated high stability. In conclusion, the two in-house-developed bone fillers revealed overall good results and are budding new developments for clinical use.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...