Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Physiol ; 14: 1172688, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37334047

RESUMO

Blood pressure (BP) surrogates, such as pulse transit time (PTT) or pulse arrival time (PAT), have been intensively explored with the goal of achieving cuffless, continuous, and accurate BP inference. In order to estimate BP, a one-point calibration strategy between PAT and BP is typically used. Recent research focuses on advanced calibration procedures exploiting the cuff inflation process to improve calibration robustness by active and controlled modulation of peripheral PAT, as measured via plethysmograph (PPG) and electrocardiogram (ECG) combination. Such methods require a detailed understanding of the mechanisms behind the vasculature's response to cuff inflation; for this, a model has recently been developed to infer the PAT-BP calibration from measured cuff-induced vasculature changes. The model, while promising, is still preliminary and only partially validated; in-depth analysis and further developments are still needed. Therefore, this work aims to improve our understanding of the cuff-vasculature interaction in this model; we seek to define potential opportunities and to highlight which aspects may require further study. We compare model behaviors with clinical data samples based on a set of observable characteristics relevant for BP inference and calibration. It is found that the observed behaviors are qualitatively well represented with the current simulation model and complexity, with limitations regarding the prediction of the onset of the distal arm dynamics and behavior changes at high cuff pressures. Additionally, a sensitivity analysis of the model's parameter space is conducted to show the factors that influence the characteristics of its observable outputs. It was revealed that easily controllable experimental variables, such as lateral cuff length and inflation rate, have a significant impact on cuff-induced vasculature changes. An interesting dependency between systemic BP and cuff-induced distal PTT change is also found, revealing opportunities for improved methods for BP surrogate calibration. However, validation via patient data shows that this relation does not hold for all patients, indicating required model improvements to be validated in follow up studies. These results provide promising directions to improve the calibration process featuring cuff inflation towards accurate and robust non-invasive blood pressure estimation.

2.
Artigo em Inglês | MEDLINE | ID: mdl-34891230

RESUMO

The blood pressure (BP) cuff can be used to modulate blood flow and propagation of pressure pulse along the artery. In our previous work, we researched methods to adapt cuff modulation techniques for pulse transit time vs. BP calibration and for measurement of other hemodynamic indices of potential interest to critical care, such as arterial compliance. A model characterized the response of the vasculature located directly under the cuff, but assumed that no significant changes occur in the distal vasculature.This study has been tailored to gain insights into the response of distal BP and pulse transit time to cuff inflation. Invasive BP data collected downstream from the cuff demonstrates that highly dynamic processes occur in the distal arm during cuff inflation. Mean arterial pressure increases in the distal artery by up to 20 mmHg, leading to a decrease in pulse transit time of up to 20 ms. Clinical Relevance: Such significant changes need to be taken into account in order to improve non-invasive BP estimations and to enable inference of other hemodynamic parameters from vasculature response to cuff inflation. A simple model is developed in order to reproduce the observed behaviors. The lumped-parameter model demonstrates opportunities for cuff modulation measurements which can reveal information on parameters such as systemic resistance, distal arterial, venous compliances and artery-vein interaction.


Assuntos
Determinação da Pressão Arterial , Análise de Onda de Pulso , Pressão Sanguínea , Frequência Cardíaca , Hemodinâmica
3.
Sensors (Basel) ; 21(16)2021 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-34451035

RESUMO

In standard critical care practice, cuff sphygmomanometry is widely used for intermittent blood pressure (BP) measurements. However, cuff devices offer ample possibility of modulating blood flow and pulse propagation along the artery. We explore underutilized arrangements of sensors involving cuff devices which could be of use in critical care to reveal additional information on compensatory mechanisms. In our previous work, we analyzed the response of the vasculature to occlusion perturbations by means of observations obtained non-invasively. In this study, our aim is to (1) acquire additional insights by means of invasive measurements and (2) based on these insights, further develop cuff-based measurement strategies. Invasive BP experimental data is collected downstream from the cuff in two patients monitored in the OR. It is found that highly dynamic processes occur in the distal arm during cuff inflation. Mean arterial pressure increases in the distal artery by 20 mmHg, leading to a decrease in pulse transit time by 20 ms. Previous characterizations neglected such distal vasculature effects. A model is developed to reproduce the observed behaviors and to provide a possible explanation of the factors that influence the distal arm mechanisms. We apply the new findings to further develop measurement strategies aimed at acquiring information on pulse arrival time vs. BP calibration, artery compliance, peripheral resistance, artery-vein interaction.


Assuntos
Determinação da Pressão Arterial , Análise de Onda de Pulso , Artérias , Pressão Sanguínea , Frequência Cardíaca , Humanos
4.
J Clin Monit Comput ; 34(6): 1351-1359, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31902094

RESUMO

Clinicians strive to maintain normothermia, which requires measurement of core-body temperature and may necessitate active warming of patients. Monitoring temperature currently requires invasive probes. This work investigates a novel foam-based flexible sensor worn behind the ear for the measurement of core body temperature. This observational study uses the device prototype and clinical data to compare three methods for calculating the temperature from this sensor: a basic heat-flow model, a new dynamic model that addresses changing surrounding temperatures and one that combines the dynamic model with a correction for adhesive quality. Clinical validation was performed with 21 surgical patients (average length of surgery 4.4 h) using an esophageal temperature probe as reference. The operative period was divided into four segments: normal periods (with stable surrounding temperatures), surrounding temperatures increasing due to the use of the Bair Hugger™, stable periods during Bair Hugger™ use and surrounding temperatures decreasing due to its removal. The error bias and limits of agreement over these segments were on average of - 0.05 ± 0.28 °C (95% limits of agreement) overall. The dynamic model outperformed the simple heat-flow model for periods of surrounding temperature changes (12.7% of total time) while it had a similar, high, performance for the temperature-stable periods. The results suggest that our proposed topical sensor can replace invasive core temp sensors and provide a means of consistently measuring core body temperature despite surrounding temperature shifts.


Assuntos
Temperatura Corporal , Temperatura Alta , Esôfago , Humanos , Temperatura
5.
J Clin Monit Comput ; 33(1): 65-75, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29644558

RESUMO

To non-invasively predict fluid responsiveness, respiration-induced pulse amplitude variation (PAV) in the photoplethysmographic (PPG) signal has been proposed as an alternative to pulse pressure variation (PPV) in the arterial blood pressure (ABP) signal. However, it is still unclear how the performance of the PPG-derived PAV is site-dependent during surgery. The aim of this study is to compare finger- and forehead-PPG derived PAV in their ability to approach the value and trend of ABP-derived PPV. Furthermore, this study investigates four potential confounding factors, (1) baseline variation, (2) PPV, (3) ratio of respiration and heart rate, and (4) perfusion index, which might affect the agreement between PPV and PAV. In this work, ABP, finger PPG, and forehead PPG were continuously recorded in 29 patients undergoing major surgery in the operating room. A total of 91.2 h data were used for analysis, from which PAV and PPV were calculated and compared. We analyzed the impact of the four factors using a multiple linear regression (MLR) analysis. The results show that compared with the ABP-derived PPV, finger-derived PAV had an agreement of 3.2 ± 5.1%, whereas forehead-PAV had an agreement of 12.0 ± 9.1%. From the MLR analysis, we found that baseline variation was a factor significantly affecting the agreement between PPV and PAV. After correcting for respiration-induced baseline variation, the agreements for finger- and forehead-derived PAV were improved to reach an agreement of - 1.2 ± 3.8% and 3.3 ± 4.8%, respectively. To conclude, finger-derived PAV showed better agreement with ABP-derived PPV compared to forehead-derived PAV. Baseline variation was a factor that significantly affected the agreement between PPV and PAV. By correcting for the baseline variation, improved agreements were obtained for both the finger and forehead, and the difference between these two agreements was diminished. The tracking abilities for both finger- and forehead-derived PAV still warrant improvement for wide use in clinical practice. Overall, our results show that baseline-corrected finger- and forehead-derived PAV may provide a non-invasive alternative for PPV.


Assuntos
Pressão Sanguínea , Salas Cirúrgicas , Fotopletismografia/métodos , Processamento de Sinais Assistido por Computador , Idoso , Pressão Arterial , Feminino , Dedos , Testa , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Respiração , Fatores de Tempo
6.
Physiol Meas ; 38(12): 2101-2121, 2017 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-29064375

RESUMO

OBJECTIVE: Arterial pulse pressure variation (PPV) is widely used for predicting fluid responsiveness and supporting fluid management in the operating room and intensive care unit. Available PPV algorithms have been typically validated for fluid responsiveness during episodes of hemodynamic stability. Yet, little is known about the performance of PPV algorithms during surgery, where fast changes of the blood pressure may affect the robustness of the presented PPV value. This work provides a comprehensive understanding of how various existing algorithmic designs affect the robustness of the presented PPV value during surgery, and proposes additional processing for the pulse pressure signal before calculating PPV. APPROACH: We recorded arterial blood pressure waveforms from 23 patients undergoing major abdominal surgery. To evaluate the performance, we designed three clinically relevant metrics. Main results and Significance: The results show that all algorithms performed well during episodes of hemodynamic stability. Moreover, it is demonstrated that the proposed processing helps improve the robustness of PPV during the entire course of surgery.


Assuntos
Algoritmos , Determinação da Pressão Arterial/métodos , Pressão Sanguínea , Monitorização Fisiológica/métodos , Abdome/cirurgia , Eletrocardiografia , Humanos , Respiração Artificial
7.
Resuscitation ; 84(11): 1625-32, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23907100

RESUMO

INTRODUCTION: Reliable, non-invasive detection of return of spontaneous circulation (ROSC) with minimal interruptions to chest compressions would be valuable for high-quality cardiopulmonary resuscitation (CPR). We investigated the potential of photoplethysmography (PPG) to detect the presence of a spontaneous pulse during automated CPR in an animal study. METHODS: Twelve anesthetized pigs were instrumented to monitor circulatory and respiratory parameters. Here we present the simultaneously recorded PPG and arterial blood pressure (ABP) signals. Ventricular fibrillation was induced, followed by 20 min of automated CPR and subsequent defibrillation. After defibrillation, pediatric-guidelines-style life support was given in cycles of 2 min. PPG and ABP waveforms were recorded during all stages of the protocol. Raw PPG waveforms were acquired with a custom-built photoplethysmograph controlling a commercial reflectance pulse oximetry probe attached to the nose. ABP was measured in the aorta. RESULTS: In nine animals ROSC was achieved. Throughout the protocol, PPG and ABP frequency content showed strong resemblance. We demonstrate that (1) the PPG waveform allows for the detection of a spontaneous pulse during ventilation pauses, and that (2) frequency analysis of the PPG waveform allows for the detection of a spontaneous pulse and the determination of the pulse rate, even during ongoing chest compressions, if the pulse and compression rates are sufficiently distinct. CONCLUSIONS: These results demonstrate the potential of PPG as a non-invasive means to detect pulse presence or absence, as well as pulse rate during CPR.


Assuntos
Reanimação Cardiopulmonar/métodos , Fotopletismografia , Pulso Arterial , Fibrilação Ventricular/terapia , Animais , Reanimação Cardiopulmonar/instrumentação , Modelos Animais de Doenças , Feminino , Suínos , Fibrilação Ventricular/fisiopatologia
8.
Resuscitation ; 82(5): 538-44, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21324578

RESUMO

Clinical observations suggest that the assumption of a linear relationship between chest compression pressure and cardiac output may be oversimplified. More complex behaviour may occur when the transmural pressure is large, changing the compliances and resistances in the intra-thoracic vasculature. A fundamental understanding of these compression induced phenomena is required for improving CPR. An extensively used, lumped element computer model (model I) of the circulation was upgraded and refined to include the intrathoracic vasculature (model II). After validation, model II was extended by adding variable compliances and resistances (model III) to the vascular structures. Successively, ranges of compression pressures, frequencies, duty cycles and compression pulse shapes were applied while controlling all other parameters. Cardiac output was then compared. The nonlinearities in compliance and resistance become important, limiting factors in cardiac output, starting in our experimental series at 70 mmHg peak compression pressure, and increasing with higher pressures. This effect is reproducible for sinusoidal and trapezoidal compression forms, resulting in lower cardiac output in all experiments at high compression pressures. Duty cycle and wait time are key parameters for cardiac output. Our data strongly indicate that vascular compliance, especially the ability of vessels to collapse (and potentially the cardiac chambers), can be a central factor in the limited output generated by chest compressions. Just pushing 'harder' or 'faster' is not always better, as an 'optimal' force and frequency may exist. Overly forceful compression can limit blood flow by restricting filling or depleting volume in the cardiac chambers and central great vessels.


Assuntos
Débito Cardíaco/fisiologia , Reanimação Cardiopulmonar , Massagem Cardíaca/métodos , Tórax/irrigação sanguínea , Resistência Vascular/fisiologia , Força Compressiva , Humanos
9.
Resuscitation ; 80(5): 546-52, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19409300

RESUMO

PURPOSE: To evaluate, in a hospital setting, the influence of different, common mattresses, with and without a backboard, on chest movement during CPR. DESIGN AND SETTING: Sixty CPR sessions (140s each, 30:2, C:R ratio 1:1) were performed using a manikin on standard hospital mattresses, with or without a backboard in combination with variable weights. Sternum-to-spine compression distance was controlled (range 30-60mm) allowing evaluation of the underlying compliant surface on total hand travel. RESULTS: Movement of the caregiver's hands was significantly larger (up to 111mm at 50mm compression depth, p<0.0001) when sternum-to-spine compressions were performed without a backboard than with one. The extent of this variable extra travel effect depended on the type of mattress as well as the force of compression. Foam mattresses and air chamber systems act as springs and follow hand movement, while 'slow foam' mattresses incorporate time delays, making depth and force sensing harder. A backboard decreases the extra hand movement due to mattress effects by more than 50%, strongly reducing caregiver work. CONCLUSIONS: Total vertical hand movement is significantly, and clinically relevantly much, larger than sternum-to-spine compression depth when CPR is performed on a mattress. Additional movement depends on the type of mattress and can be strongly reduced, but not eliminated, when a backboard is applied. The additional motion and increased work load adds extra complexity to in-hospital CPR. We propose that this should be taken into account during training by in-hospital caregivers.


Assuntos
Leitos , Reanimação Cardiopulmonar/métodos , Força Compressiva , Massagem Cardíaca/métodos , Reanimação Cardiopulmonar/instrumentação , Reanimação Cardiopulmonar/normas , Complacência (Medida de Distensibilidade) , Desenho de Equipamento , Massagem Cardíaca/instrumentação , Massagem Cardíaca/normas , Humanos , Manequins , Modelos Teóricos , Avaliação de Processos em Cuidados de Saúde , Parede Torácica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...