Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Eur Heart J Digit Health ; 4(6): 433-443, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38045434

RESUMO

Aims: Central to the practice of precision medicine in percutaneous coronary intervention (PCI) is a risk-stratification tool to predict outcomes following the procedure. This study is intended to assess machine learning (ML)-based risk models to predict clinically relevant outcomes in PCI and to support individualized clinical decision-making in this setting. Methods and results: Five different ML models [gradient boosting classifier (GBC), linear discrimination analysis, Naïve Bayes, logistic regression, and K-nearest neighbours algorithm) for the prediction of 1-year target lesion failure (TLF) were trained on an extensive data set of 35 389 patients undergoing PCI and enrolled in the global, all-comers e-ULTIMASTER registry. The data set was split into a training (80%) and a test set (20%). Twenty-three patient and procedural characteristics were used as predictive variables. The models were compared for discrimination according to the area under the receiver operating characteristic curve (AUC) and for calibration. The GBC model showed the best discriminative ability with an AUC of 0.72 (95% confidence interval 0.69-0.75) for 1-year TLF on the test set. The discriminative ability of the GBC model for the components of TLF was highest for cardiac death with an AUC of 0.82, followed by target vessel myocardial infarction with an AUC of 0.75 and clinically driven target lesion revascularization with an AUC of 0.68. The calibration was fair until the highest risk deciles showed an underestimation of the risk. Conclusion: Machine learning-derived predictive models provide a reasonably accurate prediction of 1-year TLF in patients undergoing PCI. A prospective evaluation of the predictive score is warranted. Registration: Clinicaltrial.gov identifier is NCT02188355.

2.
Drug Deliv Transl Res ; 11(5): 2144-2150, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33432522

RESUMO

Hepatic arterial infusion (HAI) of oxaliplatin allows greater liver tumour drug exposure compared to systemic infusion. However, the therapeutic index of HAI oxaliplatin remains poor. Using Pickering emulsion technology, we developed a platform able to provide sustained releases of oxaliplatin. The goal of this study was to evaluate the pharmacokinetic advantages of sustained-HAI oxaliplatin over HAI using a preclinical animal tumour model. Injections of 0.6 mg oxaliplatin in 20 min were selectively done in left hepatic arteries of 20 rabbits bearing a VX2 liver tumour in the middle left-lobe, using HAI (n = 10) or sustained-HAI (n = 10). In each group, half of the rabbits were sacrificed at 24 h and half at 72 h. Mass spectrometry was used to quantify drug pharmacokinetics in blood and oxaliplatin concentrations in tumour tissues, right- and middle left-liver lobes, spleen and lung. Compared to HAI, sustained-HAI of oxaliplatin resulted in lower plasmatic peak (Cmax: 275 ± 41 vs. 416 ± 133 ng/mL, p = 0.02) and higher concentration in the tumour at 24 h (2118 ± 2107 vs. 210 ± 93 ng/g, p = 0.008). After HAI, oxaliplatin concentration in tumours was significantly higher than in lung at 24 h (p = 0.03) but no other difference was found between oxaliplatin concentrations in tumours and in liver lobes, spleen or lung, neither at 24 h nor at 72 h. On the opposite, sustained-HAI resulted in higher concentrations of oxaliplatin in tumour compared to oxaliplatin concentrations in the middle left lobe (163 ± 86 ng/g at 24 h, p = 0.01, and 90 ± 15 ng/g at 72 h, p = 0.04), right lobe (174 ± 112 ng/g at 24 h, p = 0.01, and 112 ± 35 ng/g, p = 0.04 at 72 h), spleen (142 ± 21 ng/g at 24 h, p = 0.01, and 98 ± 12 ng/g at 72 h, p = 0.04), and lung (85 ± 11 ng/g at 24 h, p = 0.01, and 52 ± 4 ng/g at 72 h, p = 0.03). Sustained-HAI improves the therapeutic index of HAI oxaliplatin and offers a great potential for patients suffering from unresectable colorectal liver metastases or hepatocellular carcinoma.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Animais , Protocolos de Quimioterapia Combinada Antineoplásica , Neoplasias Colorretais/tratamento farmacológico , Artéria Hepática/patologia , Humanos , Infusões Intra-Arteriais/métodos , Neoplasias Hepáticas/tratamento farmacológico , Oxaliplatina/uso terapêutico , Coelhos
3.
Am J Cardiol ; 116(3): 364-71, 2015 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-26037294

RESUMO

Co-morbidities have typically been considered as prevalent cardiovascular risk factors and cardiovascular diseases rather than systematic measures of general co-morbidity burden in patients who underwent percutaneous coronary intervention (PCI). Charlson co-morbidity index (CCI) is a measure of co-morbidity burden providing a means of quantifying the prognostic impact of 22 co-morbid conditions on the basis of their number and prognostic impact. The study evaluated the impact of the CCI on cardiac mortality and major adverse cardiovascular events (MACE) after PCI through analysis of the Nobori-2 study. The prognostic impact of CCI was studied in 3,067 patients who underwent PCI in 4,479 lesions across 125 centers worldwide on 30-day and 1- and 5-year cardiac mortality and MACE. Data were adjusted for potential confounders using stepwise logistic regression; 2,280 of 3,067 patients (74.4%) had ≥1 co-morbid conditions. CCI (per unit increase) was independently associated with an increase in both cardiac death (odds ratio [OR] 1.47 95% confidence interval [CI] 1.20 to 1.80, p = 0.0002) and MACE (OR 1.29 95% CI 1.14 to 1.47, p ≤0.0011) at 30 days, with similar observations recorded at 1 and 5 years. CCI score ≥2 was independently associated with increased 30-day cardiac death (OR 4.25, 95% CI 1.24 to 14.56, p = 0.02) at 1 month, and this increased risk was also observed at 1 and 5 years. In conclusion, co-morbid burden, as measured using CCI, is an independent predictor of adverse outcomes in the short, medium, and long term. Co-morbidity should be considered in the decision-making process when counseling patients regarding the periprocedural risks associated with PCI, in conjunction with traditional risk factors.


Assuntos
Transtornos Cerebrovasculares/epidemiologia , Doença da Artéria Coronariana/epidemiologia , Stents Farmacológicos , Intervenção Coronária Percutânea , Medição de Risco , Idoso , Ásia/epidemiologia , Comorbidade/tendências , Angiografia Coronária , Doença da Artéria Coronariana/cirurgia , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Estudos Prospectivos , Fatores de Risco , Taxa de Sobrevida , Fatores de Tempo
4.
EuroIntervention ; 11(5): 549-54, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25539418

RESUMO

AIMS: To assess the safety and performance of the Nobori drug-eluting stent with biodegradable polymer versus the TAXUS drug-eluting stent with permanent polymer, in the treatment of patients with de novo coronary artery lesions. METHODS AND RESULTS: NOBORI 1 was a multicentre, randomised (2:1), prospective, controlled, clinical trial which enrolled 363 patients (238 Nobori and 125 TAXUS) with up to two de novo lesions in two epicardial vessels. The primary endpoint was in-stent late loss at nine months, while secondary endpoints included safety and efficacy up to five years. At five years, clinical data were available for 350 patients (96%). There were no differences in the composite of death and myocardial infarction (10.9% vs. 11.2%) and target lesion failure (9.2% and 10.4%), while ischaemia- and non-ischaemia-driven target lesion revascularisations were less frequent in the Nobori (6.3%) than in the TAXUS arm (16.0%). The rates of stent thrombosis (definite and probable according to the ARC definitions) were 0.0% and 3.2%, in the Nobori and TAXUS stents, respectively (p=0.014). CONCLUSIONS: Five years after implantation, the Nobori DES resulted in durable treatment effects with very low TLR and no stent thrombosis. The study was not powered to assess the differences in clinical endpoints. These data are hypothesis-generating.


Assuntos
Doença da Artéria Coronariana/terapia , Trombose Coronária/epidemiologia , Stents Farmacológicos , Oclusão de Enxerto Vascular/epidemiologia , Infarto do Miocárdio/epidemiologia , Intervenção Coronária Percutânea , Sirolimo/análogos & derivados , Implantes Absorvíveis , Idoso , Ponte de Artéria Coronária/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade , Revascularização Miocárdica/estatística & dados numéricos , Desenho de Prótese , Sirolimo/uso terapêutico , Resultado do Tratamento
5.
Eur Heart J Cardiovasc Imaging ; 15(9): 987-95, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24662443

RESUMO

AIMS: To investigate the incidence of incomplete stent apposition and to explore the impact of the presence of thrombus and protruding plaque after stent implantation on neointima formation at follow-up in ST-segment elevation myocardial infarction (STEMI) patients with serial optical frequency domain imaging (OFDI) investigations. METHODS AND RESULTS: In a multi-centre study, 141 patients with ST elevation myocardial infarction <12 h from onset were randomized to either PPCI with thrombectomy (TB) using an Eliminate catheter (TB: n = 71) or without TB (non-TB: n = 70). OFDI after drug-eluting stenting was performed using TERUMO OFDI system. Per protocol, at follow-up 49 patients segments were reimaged. At post-procedure and follow-up, there were no differences in stent and lumen areas between the two groups. At follow-up, per strut-level analysis, percentage of incompletely apposed struts was 0.42 ± 0.94 vs. 0.38 ± 0.77% (P = 0.76), and percentage of covered struts was 92.7 ± 7.2 vs. 94.4 ± 9.2% (P = 0.47) in the TB and non-TB groups, respectively. There was a positive correlation between intra-stent structure (ISS) volume at post-procedure and the neointima volume at 6-month follow-up (Pearson's r = 0.409, P = 0.04). Up to 12 months, there have been two and four patients having target vessel failure in the TB and in the non-TB groups, respectively. CONCLUSIONS: In patients with STEMI, there were no significant differences in OFDI parameters between TB and non-TB groups at both post-procedure and 6-month follow-up. However, ISS volume at post-procedure was positively associated with neointimal volume at 6-month follow-up.


Assuntos
Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Tomografia de Coerência Óptica , Cateterismo Cardíaco , Meios de Contraste , Angiografia Coronária/métodos , Stents Farmacológicos , Europa (Continente) , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Método Simples-Cego , Trombectomia , Resultado do Tratamento
6.
PLoS One ; 9(2): e88577, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24551120

RESUMO

BACKGROUND: Contemporary data remains limited regarding mortality and major adverse cardiac events (MACE) outcomes in patients undergoing PCI for different manifestations of coronary artery disease. OBJECTIVES: We evaluated mortality and MACE outcomes in patients treated with PCI for STEMI (ST-elevation myocardial infarction), NSTEMI (non ST-elevation myocardial infarction) and stable angina through analysis of data derived from the Nobori-2 study. METHODS: Clinical endpoints were cardiac mortality and MACE (a composite of cardiac death, myocardial infarction and target vessel revascularization). RESULTS: 1909 patients who underwent PCI were studied; 1332 with stable angina, 248 with STEMI and 329 with NSTEMI. Age-adjusted Charlson co-morbidity index was greatest in the NSTEMI cohort (3.78±1.91) and lowest in the stable angina cohort (3.00±1.69); P<0.0001. Following Cox multivariate analysis cardiac mortality was independently worse in the NSTEMI vs the stable angina cohort (HR 2.31 (1.10-4.87), p = 0.028) but not significantly different for STEMI vs stable angina cohort (HR 0.72 (0.16-3.19), p = 0.67). Similar observations were recorded for MACE (<180 days) (NSTEMI vs stable angina: HR 2.34 (1.21-4.55), p = 0.012; STEMI vs stable angina: HR 2.19 (0.97-4.98), p = 0.061. CONCLUSIONS: The longer-term Cardiac mortality and MACE were significantly worse for patients following PCI for NSTEMI even after adjustment of clinical demographics and Charlson co-morbidity index whilst the longer-term prognosis of patients following PCI STEMI was favorable, with similar outcomes as those patients with stable angina following PCI.


Assuntos
Síndrome Coronariana Aguda/terapia , Angina Estável/terapia , Idoso , Morte , Demografia , Stents Farmacológicos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Modelos de Riscos Proporcionais , Estudos Prospectivos , Resultado do Tratamento
7.
Cardiovasc Revasc Med ; 14(6): 325-32, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24070549

RESUMO

BACKGROUND: The current revascularization treatment recommendation is different according to lesion location and a higher recommendation is given to surgery for proximal LAD (pLAD) lesions over PCI. This is based on previous studies and expert opinion. We aimed to investigate whether indeed there is a difference in outcome with respect to LAD lesion location while using a drug eluting stent (DES). METHODS: The NOBORI-2 trial, enrolled 3067 consecutive patients in 125 centers who were treated with DES for single and multivessel disease. We compared 834 [27.2%] patients who underwent PCI of the pLAD as part of their revascularization, to 2203 [71.8%] patients in which stenting to other lesion(s) but not the pLAD was performed. RESULTS: The pLAD group had lower incidence of hypertension, peripheral vascular disease, prior PCI and CABG, but had more lesions treated [1.55 ± 0.8 vs. 1.35 ± 0.6], more stents implanted [1.98 ± 1.2 vs. 1.66 ± 1.0] and longer overall stent length [31.8 ± 20.2 vs. 28.2 ± 17.8 mm]. There was no difference in the occurrence of the primary endpoint [cardiac death, myocardial infarction and target lesion revascularization] at 1 or 2 years of follow up between the pLAD and non pLAD [6.0% vs. 4.6%, p=0.14 and 7.7% vs. 6.6%; p=0.22, respectively]. The relief from anginal symptoms was similar. Multivariate analysis showed that pLAD location was not a variable that predicted MACE or TLF. Stent thrombosis rate was similar. CONCLUSION: When considering PCI with DES, there is no difference in outcome between patients with and without proximal LAD lesions.


Assuntos
Trombose Coronária/terapia , Stents Farmacológicos , Infarto do Miocárdio/terapia , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Resultado do Tratamento
8.
Eur Heart J ; 34(14): 1050-60, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23396493

RESUMO

AIMS: Primary percutaneous coronary intervention (PPCI) with thrombectomy (TB) seems to reduce the thrombus burden, resulting in a larger flow area as measured with optical frequency domain imaging (OFDI). METHODS AND RESULTS: In a multi-centre study, 141 patients with ST elevation myocardial infarction <12 h from onset were randomized to either PPCI with TB using an Eliminate catheter (TB: n = 71) or without TB (non-TB: n = 70), having operators blinded for the OFDI results. The primary endpoint was minimum flow area (MinFA) post-procedure assessed by OFDI, defined as: [stent area + incomplete stent apposition (ISA) area] - (intraluminal defect + tissue prolapse area). Sample size was based on the expected difference of 0.72 mm(2) in MinFA. Baseline demographics, pre-procedural quantitative coronary angiography (QCA), and procedural characteristics were well matched between the two groups. On OFDI, the stent area (TB: 7.62 ± 2.23 mm(2), non-TB: 7.05 ± 2.12 mm(2), P = 0.14) and MinFA (TB: 7.08 ± 2.14 mm(2) vs. non-TB: 6.51 ± 1.99 mm(2), Δ0.57 mm(2), P = 0.12) were not different. In addition, the amount of protrusion, intraluminal defect, and ISA area were similar in the both groups. CONCLUSION: PPCI with TB was associated with a similar flow area as well as stent area to PPCI without TB.


Assuntos
Trombose Coronária/terapia , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/métodos , Trombectomia/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Técnicas de Imagem Cardíaca/métodos , Circulação Coronária/fisiologia , Trombose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Estudos Prospectivos , Resultado do Tratamento
9.
EuroIntervention ; 8(1): 109-16, 2012 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-22278136

RESUMO

AIMS: Previous studies for approved indications (on-label) have shown the good safety and efficacy profiles of the Nobori DES. We conducted a prospective, multicentre study to validate the clinical performance of this stent in a real-world setting. METHODS AND RESULTS: A total of 3,067 consecutive patients undergoing a percutaneous coronary intervention with the Nobori DES were enrolled in the NOBORI 2 registry. At one and two years, 97% and 95% of patients, respectively, were available for follow-up. The rates of target lesion failure (TLF), cardiac death, myocardial infarction and target lesion revascularisations were: 3.9%, 1.2%, 1.9% and 2.2% at one year and 5.1%, 1.6%, 2.4% and 3.0% at two years. Overall, 2,242 patients (73%) were treated for at least one off-label indication. When comparing off-label and on-label groups, the results were: TLF 4.5% vs. 2.2%, p=0.003 at one year and 5.9% vs. 2.8%, p=0.001 at two years. The rate of stent thrombosis was 0.68%, and 0.80% at one and two years, respectively with no difference between the off-label and on-label groups (0.76% vs. 0.48%, p=0.6 and 0.89% vs. 0.61%, p=0.5). CONCLUSIONS: The promising results previously observed in lower risk patients can be replicated in daily practice. As expected, in off-label indications, rates of adverse events were higher. Nevertheless, our results suggest the good and sustained performance of this stent system in high-risk patients with significant comorbidities and/or complex lesions.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Polímeros , Idoso , Análise de Variância , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Ásia , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/mortalidade , Europa (Continente) , Feminino , Fidelidade a Diretrizes , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Guias de Prática Clínica como Assunto , Rotulagem de Produtos , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
10.
Eur Heart J ; 31(14): 1792-801, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20525979

RESUMO

AIMS: Coronary late stent thrombosis, a rare but devastating complication, remains an important concern in particular with the increasing use of drug-eluting stents. Notably, pathological studies have indicated that the proportion of uncovered coronary stent struts represents the best morphometric predictor of late stent thrombosis. Intracoronary optical frequency domain imaging (OFDI), a novel second-generation optical coherence tomography (OCT)-derived imaging method, may allow rapid imaging for the detection of coronary stent strut coverage with a markedly higher precision when compared with intravascular ultrasound, due to a microscopic resolution (axial approximately 10-20 microm), and at a substantially increased speed of image acquisition when compared with first-generation time-domain OCT. However, a histological validation of coronary OFDI for the evaluation of stent strut coverage in vivo is urgently needed. Hence, the present study was designed to evaluate the capacity of coronary OFDI by electron (SEM) and light microscopy (LM) analysis to detect and evaluate stent strut coverage in a porcine model. METHODS AND RESULTS: Twenty stents were implanted into 10 pigs and coronary OFDI was performed after 1, 3, 10, 14, and 28 days. Neointimal thickness as detected by OFDI correlated closely with neointimal thickness as measured by LM (r = 0.90, P < 0.01). The comparison of stent strut coverage as detected by OFDI and SEM analysis revealed an excellent agreement (r = 0.96, P < 0.01). In particular, stents completely covered by OFDI analysis were also completely covered by SEM analysis. All incompletely covered stents by OFDI were also incompletely covered by SEM. Analyses of fibrin-covered stent struts suggested that these may rarely be detected as uncovered stent struts by OFDI. Importantly, optical density measurements revealed a significant difference between fibrin- and neointima-covered coronary stent struts [0.395 (0.35-0.43) vs. 0.53 (0.47-0.57); P < 0.001], suggesting that differences in optical density provide information on the type of stent strut coverage. The sensitivity and specificity for detection of fibrin vs. neointimal coverage was evaluated using receiver-operating characteristic analysis. CONCLUSION: The present study demonstrates that OFDI is a highly promising tool for accurate evaluation of coronary stent strut coverage, as supported by a high agreement between OFDI and light and electron microscopic analysis. Furthermore, our data indicate that optical density measurements can provide additional information with respect to the type of stent strut coverage, i.e. fibrin vs. neointimal coverage. Therefore, coronary OFDI analysis will provide important information on the biocompatibility of coronary stents.


Assuntos
Stents , Tomografia de Coerência Óptica/métodos , Cicatrização/fisiologia , Animais , Vasos Coronários/anatomia & histologia , Fibrina/análise , Oclusão de Enxerto Vascular/etiologia , Microscopia , Microscopia Eletrônica de Varredura , Falha de Prótese/etiologia , Curva ROC , Suínos
11.
EuroIntervention ; 5(6): 687-91, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20142219

RESUMO

AIMS: To evaluate a newly developed self-expanding Misago (Terumo Corp., Tokyo, Japan) nitinol stent with rapid exchange delivery catheter for the treatment of stenotic or occluded superficial femoral (SF) or popliteal arteries. METHODS AND RESULTS: MISAGO 1 clinical trial enrolled 55 patients undergoing percutaneous intervention of totally occluded or stenotic lesions in SF or popliteal arteries treated with the implantation of 81 stents in five centres across Europe. Primary endpoint was restenosis rate at six months assessed by duplex sonography. Patients (67% male) were 68+/-9 years old, 60% were smokers and 31% had diabetes. Clinical symptoms of ischaemia were present in all patients. Average lesion length was 85+/-50 mm, 64% were totally occluded and 38% classified as TASC C or D. The technical success rate was 100% while the procedural success rate was 98.2% without death, MI, stroke, or major bleeding. At six months follow-up the restenosis rate was 8.5%. One patient (1.8%) died of bronchial carcinoma and two (3.6%) underwent target vessel revascularisation. Mean ankle brachial index improved from 0.70 at baseline to 0.95 at six months while walking capacity on treadmill test improved with an average of 147 m. Rutherford index at six months demonstrated improvement of 72%, without any patients having symptom deterioration. One case of stent fracture was observed. CONCLUSIONS: The results from this first-in-man study indicate good safety and short to medium term efficacy profile of the Misago nitinol stent.


Assuntos
Ligas , Arteriopatias Oclusivas/cirurgia , Prótese Vascular , Artéria Femoral , Oclusão de Enxerto Vascular/prevenção & controle , Artéria Poplítea , Stents , Idoso , Arteriopatias Oclusivas/diagnóstico por imagem , Europa (Continente) , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/epidemiologia , Humanos , Incidência , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla
12.
Circ Cardiovasc Interv ; 2(3): 188-95, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20031715

RESUMO

BACKGROUND: The newly developed Nobori coronary stent coated with a bioresorbable polymer, polylactic acid, and the antiproliferative agent Biolimus A9 has the potential to reduce restenosis by suppressing neointima formation. METHODS AND RESULTS: We conducted a randomized (2:1), controlled trial comparing the Biolimus A9-eluting stent Nobori and the paclitaxel-eluting stent Taxus Liberté, in 243 patients (153 Nobori and 90 Taxus) at 29 centers in Europe, Asia, and Australia. Patients with previously untreated lesions in up to 2 native coronary arteries were considered for enrollment. The primary end point was in-stent late loss at 9 months, whereas secondary end points included other quantitative coronary angiography parameters, such as in-segment late loss and the rate of restenosis as well as key intravascular ultrasound parameters. Clinical secondary end points were stent thrombosis and composite of major adverse cardiac events comprising death, myocardial infarction, and target vessel revascularization. At 9 months, the in-stent late loss was significantly lower in the Nobori group compared with the Taxus group (0.11+/-0.30 mm versus 0.32+/-0.50 mm) reaching both the primary hypothesis of noninferiority of Nobori stent versus Taxus Liberté stent (P<0.001) and the secondary hypothesis of superiority (P=0.001). This finding was confirmed by a significant reduction in binary restenosis from 6.2% in Taxus to 0.7% in Nobori (P=0.02) and neointimal volume obstruction, detected by intravascular ultrasound, from 5.5+/-7.2% in Taxus to 1.8+/-5.2% in Nobori (P=0.01). The major adverse cardiac events rate was 4.6% in the Nobori and 5.6% in the Taxus cohort of patients. The stent thrombosis rate was 0% in the Nobori arm and 4.4% in the Taxus arm. CONCLUSIONS: The NOBORI 1 clinical trial confirmed its primary hypothesis--noninferiority of the Nobori Biolimus A9-eluting stent versus the Taxus Liberté stent in reducing neointimal proliferation. Both stents showed a low major adverse cardiac events rate in the studied population.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Reestenose Coronária/prevenção & controle , Estenose Coronária/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Paclitaxel/administração & dosagem , Sirolimo/análogos & derivados , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Ásia , Austrália , Proliferação de Células/efeitos dos fármacos , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Europa (Continente) , Feminino , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/prevenção & controle , Estudos Prospectivos , Medição de Risco , Sirolimo/administração & dosagem , Trombose/etiologia , Trombose/prevenção & controle , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
13.
Catheter Cardiovasc Interv ; 72(7): 901-8, 2008 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-19016466

RESUMO

OBJECTIVES: The aim of this study was to assess the pharmacokinetics and tolerability of Biolimus A9 eluted from Nobori coronary stents. BACKGROUND: : The release kinetics and pharmacokinetics of drugs delivered via coronary stents have been shown to play an essential role in the efficacy and safety of drug eluting stents. METHODS: Twenty patients with coronary artery disease were treated with single 14-mm (10 patients) or 28-mm long stent (10 patients). Blood samples were drawn at 16 time points to determine the pharmacokinetics of Biolimus A9. At seven time points, complete laboratory and toxicology panels were assessed to screen for potential Biolimus A9 toxicity. The primary endpoint of the study was the systemic blood concentrations of Biolimus A9 after 28 days and 6 months as measured using highly specific and sensitive liquid chromatography- tandem mass spectrometry assay. RESULTS: At 28 days, 6 patients (30%) had quantifiable Biolimus A9 concentrations in blood. The highest Biolimus A9 blood concentration measured in any sample was 32.2 pg/mL. The median time to maximum concentration was 2 hr, ranging from 0.05 hr to 3 months. Six months after stent implantation, only 1 of 20 patients had measurable Biolimus A9 concentrations at the lowest level of quantification, while at 9 months no sample had quantifiable Biolimus A9 concentrations. Laboratory and toxicology assessments did not indicate any impact of Biolimus A9 on the evaluated parameters. CONCLUSION: Results of this study suggest that systemic exposure to Biolimus A9 was very low and that Biolimus A9 was well tolerated.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/farmacocinética , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Fármacos Cardiovasculares/sangue , Cromatografia Líquida , Colorado , Doença da Artéria Coronariana/tratamento farmacológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Sérvia , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Sirolimo/sangue , Sirolimo/farmacocinética , Espectrometria de Massas em Tandem , Resultado do Tratamento
14.
EuroIntervention ; 3(5): 574-9, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19608483

RESUMO

AIM: To compare clinical efficacy and safety of stents eluting limus drugs from biodegradable polymer - Nobori, or durable polymer - Cypher. METHODS AND RESULTS: From May to August 2006, 107 patients with 142 coronary artery lesions were treated with either Nobori, Biolimus A9 eluting stent (54) or Cypher, Sirolimus eluting stent (53) in five centres. The two groups were well matched for baseline clinical and angiographic characteristics. The in-stent late loss at nine months, the primary endpoint of the study, was 0.10+/-0.26 mm in Nobori, and 0.13+/-0.44 mm in Cypher arm (p=0.660) confirming the hypothesis of the similarity between the two stents. In-stent diameter stenosis of 13+/-10% with Nobori was significantly lower than 20+/-12% with Cypher stent (p=0.002) without significant difference in binary restenosis (1.7% in Nobori and 6.3% in Cypher arm; p=0.32). The rate of major adverse cardiac events at 12 months was 1.9% with Nobori and 4.1% with Cypher stent. CONCLUSIONS: The nine months angiographic data from Nobori Core study demonstrate that Biolimus A9 has similar anti-proliferative efficacy to Sirolimus as judged by in-stent late loss and restenosis rate. Low frequency of adverse cardiac events at 12 months indicates that both stents are safe and effective in the studied population.

15.
EuroIntervention ; 2(4): 426-34, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19755281

RESUMO

BACKGROUND: We studied the Nobori coronary stent coated with a bioabsorbable polymer and the anti-proliferative agent Biolimus A9 which may reduce neointimal formation. METHODS AND RESULTS: Patients undergoing percutaneous coronary intervention for de novo lesions in up to two native coronary arteries, in 29 centres across Europe, Asia and Australia were randomly (2:1) assigned to receive the Biolimus A9 eluting stent Nobori (85 patients) or paclitaxel eluting stent Taxus(R) (35 patients). The two groups were well matched in baseline characteristics. The primary end point of non-inferiority for in-stent late loss of Nobori stent versus Taxus(R) stent, at 9 months, was reached with the values of 0.15+/-0.27 mm with Nobori stent and 0.32+/-0.33 mm with Taxus(R) stent (p=0.006). Neointimal volume obstruction was 2.2+/-6.0% and 8.9+/-9.2% for Nobori and Taxus(R) stent respectively (p=0.017). The rates of death, myocardial infarction and any target vessel revascularisation at 9 months were 0%, 4.7%, and 7.1% respectively for Nobori stent, and 0%, 8.6% and 14.3% respectively for Taxus(R) stent. Clinically-driven target lesion revascularisation rate was 0% for Nobori stent and 2.9% for Taxus(R) stent. Stent thrombosis rates at 9 months were 0% in both groups. CONCLUSIONS: In this trial the Nobori Biolimus A9 eluting stent proved to be safe and effective in reducing neointimal proliferation. The long term safety remains to be confirmed during the extended follow-up period of 5 years.

16.
EuroIntervention ; 3(2): 249-55, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19758946

RESUMO

AIMS: To evaluate a new generation, thin strut, stainless steel Tsunami coronary stent in a contemporary percutaneous coronary intervention (PCI) practice across a wide geographical area. METHODS AND RESULTS: Patients (n=1,437) with single or multiple vessel coronary artery disease undergoing PCI in 82 sites in Europe, Asia, and Australia were enrolled in the MATSURI registry. Clinical follow-ups were scheduled at 1, 6 and 18 months. Primary endpoint was major adverse cardiac events (MACE) rate at 6 months. Diabetes was present in 25% of patients, 40% had unstable angina, 54% multivessel disease and 31% previously underwent PCI/CABG. Procedural success was achieved in 98.1% of patients. MACE rate was 1.8%, 7.3%, and 12.6% for 1, 6 and 18 month follow-up, respectively. At 6 months, the incidence of cardiac death, MI and TLR were 1%, 1.9% and 4.5% respectively, and confirmed stent thrombosis occurred in 0.2% of patients. Lower risk patients (43% of registry population) had six months MACE free survival of 96.7%. CONCLUSIONS: Based on the results of this large registry we can conclude that the Tsunami BMS combines excellent deliverability and safety for all, together with very low MACE rates for lower risk patients. Long term follow-up confirmed sustained clinical benefit.

17.
Transfusion ; 46(2): 230-5, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16441600

RESUMO

BACKGROUND: Cryobiologic variables responsible for cell injuries and freezing techniques applicable in medical cryopractice should be revised and/or reengineered for minimizing cryoinjuries and maximizing cell recovery. In this study, the efficacy of different cryopreservation protocols based on platelet (PLT) recovery was evaluated. STUDY DESIGN AND METHODS: PLTs (n = 33) were prepared from whole-blood units. Cell count and viability, PLT morphologic score (PMS), and hypotonic shock response were determined. PLT surface antigens were measured by flow cytometry. Controlled-rate (with compensated fusion heat) and uncontrolled-rate freezing methods combined with 6 percent dimethyl sulfoxide were used. RESULTS: PLT recovery was superior in the controlled-rate setting (91.0 +/- 5.5 vs. 86.0 +/- 6.5; p < 0.05). PMS was significantly better in controlled-rate freezing (p < 0.01). GPIb/CD42b expression was reduced in both freezing groups versus control. GP140/CD62p expression was significantly (p < 0.05) lower in the controlled-rate group and in both frozen groups was significantly higher than in the control groups. CONCLUSION: The use of strictly equalized (1 degrees C/min) controlled-rate freezing, combined with an intensified cooling rate (2 degrees C/min) during the liquid-to-solid-phase transition period, allows advanced quantitative and qualitative PLT recovery, even though the minor intergroup differences for some variables were observed.


Assuntos
Plaquetas/citologia , Preservação de Sangue/métodos , Criopreservação/métodos , Adulto , Antígenos de Plaquetas Humanas/metabolismo , Plaquetas/metabolismo , Forma Celular , Sobrevivência Celular , Citometria de Fluxo , Congelamento , Humanos , Masculino
18.
Transfusion ; 44(8): 1197-203, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15265124

RESUMO

BACKGROUND: Whole-blood (WB) leukoreduction filters in current use retain the majority of PLTs. A new whole-blood filter, which retains significantly fewer of the PLTs (or saves PLTs [WB-SP]), has been developed. The performance characteristics of the WB-SP filter have been evaluated in a multicenter study. STUDY DESIGN AND METHODS: A total of 617 units of WB was collected into quadruple bag sets with an integrated WB-SP filter, leukoreduced, and processed into leukoreduced RBCs (LR-RBC), plasma (LR-PL), and buffy coats (LR-BC) from which, pooled, leukoreduced, PLT concentrates (LR-PCs) were produced. Recovery, yield, and residual WBCs were assessed in prepared blood components. RESULTS: The median residual WBC number in the LR-RBCs was 0.05 x 10(6) (range, <0.05-3.8), exceeding 1 x 10(6) in 0.6 percent of the units. Median Hb content in LR-RBC was 50 g (range, 34-72), reflecting a final RBC recovery of 81 +/- 6 percent. The median WBC content of the LR-PC was 0.05 x 10(6) (range, <0.05-0.28), with none exceeding 1 x 10(6). The median PLT content of the LR-PC, per individual donation, was 6.4 x 10(10) (range, 4.1-10.7), representing a final recovery of 62 +/- 10 percent. The mean FVIII activity was 104 +/- 25 percent and 83 +/- 11 percent in plasma separated from fresh or overnight stored WB, respectively. CONCLUSION: Use of the WB-SP filter makes it possible to obtain three leukoreduced blood components with only one filtration step. The WB-SP filter showed good leukoreduction performance and recovery of all blood components including PLTs.


Assuntos
Remoção de Componentes Sanguíneos/instrumentação , Plaquetas , Filtração/métodos , Leucócitos , Humanos
19.
Transfusion ; 43(12): 1723-8, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14641870

RESUMO

BACKGROUND: A novel WBC-reduction in-line whole-blood (WB) filter that does not retain platelets was evaluated to assess the filtration performance and, after processing WB by the platelet-rich plasma (PRP) method, to analyze the storage quality of filtered platelet concentrate (PC) units. STUDY DESIGN AND METHODS: To analyze the filter retention, blood was collected from random donors into quadruple blood packs with an integral in-line filter (Imuflex WB-SP, Terumo; n = 25) or in standard triple bag systems (n = 30). To assess the in vitro storage characteristics of platelets, 26 WB units were pooled in pairs and redistributed into 13 units that underwent WBC reduction and 13 units that were not WBC reduced. In all cases, WB was separated into RBCs, PCs, and plasma by the PRP method and platelet function was compared. RESULTS: The filtration procedure led to RBC and PC WBC-reduced products that met the AABB and European requirements. The average filtration time was 30 minutes, the filter retained about 45 mL of WB, and there was no further loss of RBCs during the fractionation procedure. In vitro PC storage characteristics of the filtered units were similar to those of the nonfiltered units. CONCLUSION: A 4- and 3-log WBC reduction was observed in RBC and PC units that were produced by the PRP method, with a mean residual WBC content of 0.24 +/- 0.38 x 106 and 0.02 +/- 0.03 x 106 per unit, respectively. The procedure, performed under relatively simple logistics, results in good-quality, standard components that may reduce costs and ease the process of WBC reduction in transfusion services.


Assuntos
Remoção de Componentes Sanguíneos/instrumentação , Remoção de Componentes Sanguíneos/métodos , Plaquetas , Transfusão de Plaquetas , Preservação de Sangue , Estudos de Avaliação como Assunto , Filtração/instrumentação , Humanos , Técnicas In Vitro , Leucócitos , Ativação Plaquetária , Distribuição Aleatória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...