Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Med Imaging ; 41(11): 2980-2990, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35584078

RESUMO

Breast microcalcifications are an important primary radiological indicator of breast cancer. However, microcalcification classification and diagnosis may be still challenging for radiologists due to limitations of the standard 2D mammography technique, including spatial and contrast resolution. In this study, we propose an approach to improve the detection of microcalcifications in propagation-based phase-contrast X-ray computed tomography of breast tissues. Five fresh mastectomies containing microcalcifications were scanned at different X-ray energies and radiation doses using synchrotron radiation. Both bright-field (i.e. conventional phase-retrieved images) and dark-field images were extracted from the same data sets using different image processing methods. A quantitative analysis was performed in terms of visibility and contrast-to-noise ratio of microcalcifications. The results show that while the signal-to-noise and the contrast-to-noise ratios are lower, the visibility of the microcalcifications is more than two times higher in the dark-field images compared to the bright-field images. Dark-field images have also provided more accurate information about the size and shape of the microcalcifications.


Assuntos
Doenças Mamárias , Neoplasias da Mama , Calcinose , Humanos , Feminino , Mamografia/métodos , Calcinose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem
2.
Opt Lett ; 47(8): 1945-1948, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35427307

RESUMO

Propagation-based phase-contrast x-ray imaging (PB-PCXI) generates image contrast by utilizing sample-imposed phase-shifts. This has proven useful when imaging weakly attenuating samples, as conventional attenuation-based imaging does not always provide adequate contrast. We present a PB-PCXI algorithm capable of extracting the x-ray attenuation  ß and refraction  δ, components of the complex refractive index of distinct materials within an unknown sample. The method involves curve fitting an error-function-based model to a phase-retrieved interface in a PB-PCXI tomographic reconstruction, which is obtained when Paganin-type phase retrieval is applied with incorrect values of δ and ß. The fit parameters can then be used to calculate true δ and ß values for composite materials. This approach requires no a priori sample information, making it broadly applicable. Our PB-PCXI reconstruction is single-distance, requiring only one exposure per tomographic angle, which is important for radiosensitive samples. We apply this approach to a breast-tissue sample, recovering the refraction component  Î´, with 0.6-2.4% accuracy compared with theoretical values.


Assuntos
Tomografia Computadorizada por Raios X , Tomografia , Algoritmos , Imageamento Tridimensional , Tomografia Computadorizada por Raios X/métodos , Raios X
3.
J Synchrotron Radiat ; 28(Pt 1): 283-291, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33399579

RESUMO

Analyser-based phase-contrast imaging (ABPCI) is a highly sensitive phase-contrast imaging method that produces high-contrast images of weakly absorbing materials. However, it is only sensitive to phase gradient components lying in the diffraction plane of the analyser crystal [i.e. in one dimension (1-D)]. In order to accurately account for and measure phase effects produced by the wavefield-sample interaction, ABPCI and other 1-D phase-sensitive methods must achieve 2-D phase gradient sensitivity. An inclined geometry method was applied to a Laue geometry setup for X-ray ABPCI through rotation of the detector and object about the optical axis. This allowed this traditionally 1-D phase-sensitive phase-contrast method to possess 2-D phase gradient sensitivity. Tomographic datasets were acquired over 360° of a multi-material phantom with the detector and sample tilted by 8°. The real and imaginary parts of the refractive index were reconstructed for the phantom.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Óptica e Fotônica , Imagens de Fantasmas , Síncrotrons
4.
Med Phys ; 46(12): 5478-5487, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31574166

RESUMO

PURPOSE: Propagation-based phase-contrast computed tomography (PB-CT) is a method for three-dimensional x-ray imaging that utilizes refraction, as well as absorption, of x rays in the tissues to increase the signal-to-noise ratio (SNR) in the resultant images, in comparison with equivalent conventional absorption-only x-ray tomography (CT). Importantly, the higher SNR is achieved without sacrificing spatial resolution or increasing the radiation dose delivered to the imaged tissues. The present work has been carried out in the context of the current development of a breast CT imaging facility at the Australian Synchrotron. METHODS: Seven unfixed complete mastectomy samples with and without breast cancer lesions have been imaged using absorption-only CT and PB-CT techniques under controlled experimental conditions. The radiation doses delivered to the mastectomy samples during the scans were comparable to those approved for mammographic screening. Physical characteristics of the reconstructed images, such as spatial resolution and SNR, have been measured and compared with the results of the radiological quality assessment of the complete absorption CT and PB-CT image stacks. RESULTS: Despite the presence of some image artefacts, the PB-CT images have outperformed comparable absorption CT images collected at the same radiation dose, in terms of both the measured objective image characteristics and the radiological image scores. The outcomes of these experiments are shown to be consistent with predictions of the theory of PB-CT imaging and previous reported experimental studies of this imaging modality. CONCLUSIONS: The results presented in this paper demonstrate that PB-CT holds a high potential for improving on the quality and diagnostic value of images obtained using existing medical x-ray technologies, such as mammography and digital breast tomosynthesis (DBT). If implemented at suitable synchrotron imaging facilities, PB-CT can be used to complement existing imaging modalities, leading to more accurate breast cancer diagnosis.


Assuntos
Mastectomia , Síncrotrons , Tomografia Computadorizada por Raios X/instrumentação , Mama/diagnóstico por imagem , Mama/cirurgia , Feminino , Humanos , Processamento de Imagem Assistida por Computador
5.
Opt Express ; 22(18): 21508-20, 2014 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-25321529

RESUMO

We present the theoretical description of the image formation with the in-line germanium Bragg Magnifier Microscope (BMM) and the first successful phase retrieval of X-ray holograms recorded with this imaging system. The conditions under which the BMM acts as a linear shift invariant system are theoretically explained and supported by the experiment. Such an approach simplifies the mathematical treatment of the image formation and reconstruction as complicated propagation of the wavefront onto inclined planes can be avoided. Quantitative phase retrieval is demonstrated using a test sample and a proof of concept phase imaging of a spider leg is also presented.

6.
Phys Rev Lett ; 102(4): 043901, 2009 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-19257417

RESUMO

A massively parallel deterministic method is described for reconstructing shift-invariant complex Green's functions. As a first experimental implementation, we use a single phase contrast x-ray image to reconstruct the complex Green's function associated with Bragg reflection from a thick perfect crystal. The reconstruction is in excellent agreement with a classic prediction of dynamical diffraction theory.

7.
J Phys Condens Matter ; 21(31): 314022, 2009 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-21828583

RESUMO

We apply Lloyd's mirror photoemission electron microscopy (PEEM) to study the surface shape of Ga droplets on GaAs(001). An unusual rectangular-based droplet shape is identified and the contact angle is determined in situ. It is shown that quenching does not appreciably affect droplet shape and ex situ measurements of the contact angle by atomic force microscopy are in good agreement with Lloyd's mirror PEEM. Extension of Lloyd's mirror technique to reconstruct general three-dimensional (3D) surface shapes and the potential use of synchrotron radiation to improve vertical resolution is discussed.

8.
Phys Med Biol ; 52(14): 4171-87, 2007 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-17664601

RESUMO

Analyser-based phase contrast imaging can provide radiographs of exceptional contrast at high resolution (<100 microm), whilst quantitative phase and attenuation information can be extracted using just two images when the approximations of geometrical optics are satisfied. Analytical phase retrieval can be performed by fitting the analyser rocking curve with a symmetric Pearson type VII function. The Pearson VII function provided at least a 10% better fit to experimentally measured rocking curves than linear or Gaussian functions. A test phantom, a hollow nylon cylinder, was imaged at 20 keV using a Si(1 1 1) analyser at the ELETTRA synchrotron radiation facility. Our phase retrieval method yielded a more accurate object reconstruction than methods based on a linear fit to the rocking curve. Where reconstructions failed to map expected values, calculations of the Takagi number permitted distinction between the violation of the geometrical optics conditions and the failure of curve fitting procedures. The need for synchronized object/detector translation stages was removed by using a large, divergent beam and imaging the object in segments. Our image acquisition and reconstruction procedure enables quantitative phase retrieval for systems with a divergent source and accounts for imperfections in the analyser.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Óptica e Fotônica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Phys Rev Lett ; 99(1): 016103, 2007 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-17678166

RESUMO

We use Lloyd's mirror to modulate electron photoemission in photoemission electron microscopy. This results in the projection of Lloyd's fringes on to three-dimensional (3D) surface objects. An iterative reconstruction method is used to correct for distortions in the fringe pattern due to the cathode immersion lens, thereby providing a quantitative interpretation of surface shape. It is therefore possible to extract 3D height information directly from a two-dimensional, plan-view image. The technique is of sufficient intensity and contrast to study real-time changes in surface topography and we apply the method to study unusual contact-line dynamics during the reactive wetting of metal droplets.

10.
Opt Express ; 15(16): 9954-62, 2007 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-19547345

RESUMO

We develop a deterministic algorithm for coherent diffractive imaging (CDI) that employs a modified Fourier transform of a Fraunhofer diffraction pattern to quantitatively reconstruct the complex scalar wavefield at the exit surface of a sample of interest. The sample is placed in a uniformly-illuminated rectangular hole with dimensions at least two times larger than the sample. For this particular scenario, and in the far-field diffraction case, our non-iterative reconstruction algorithm is rapid, exact and gives a unique analytical solution to the inverse problem. The efficacy and stability of the algorithm, which may achieve resolutions in the nanoscale range, is demonstrated using simulated X-ray data.

11.
Br J Radiol ; 78(935): 1018-27, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16249603

RESUMO

The significant degree of X-ray phase contrast created by air-tissue interfaces, coupled with the poor radiographic contrast of conventional chest radiographs, makes the inflated lung an ideal candidate for investigating the potential diagnostic improvement afforded by phase contrast X-ray imaging. In small animals these methods highlight the lung airways and lobe boundaries and reveal the lung tissue as a speckled intensity pattern not seen in other soft tissues. We have compared analyser-based and propagation-based phase contrast imaging modalities, together with conventional radiographic imaging, to ascertain which technique shows the greatest image enhancement for various lung sizes. The conventional radiographic image of a mouse was obtained on a Siemens Nova 3000 mammography system, whilst phase contrast images of mice and rabbit chests were acquired at the medical imaging beamline (20B2) at the SPring-8 synchrotron radiation research facility in Japan. For mice aged 1 day, 1 week and 1 month old it was determined that analyser-based imaging showed the greatest overall image contrast, however, for an adult rabbit both techniques yielded excellent contrast. The success of these methods in creating high quality images for rabbit lungs raises the possibility of improving human lung imaging using phase contrast techniques.


Assuntos
Pulmão/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Animais , Feminino , Mamografia/instrumentação , Camundongos , Coelhos , Interpretação de Imagem Radiográfica Assistida por Computador , Especificidade da Espécie
12.
J Synchrotron Radiat ; 11(Pt 5): 406-13, 2004 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-15310957

RESUMO

Weissenberg screens and a translating cassette have been employed to allow an imaging plate to collect 30 scans per readout. In this configuration the imaging plate functions as a curved one-dimensional position-sensitive detector and, by changing the sample angle for each of the scans, two-dimensional images were produced in reciprocal space. This method of data collection leads to a reduction in scan time compared with methods based on a scintillation detector, particularly for asymmetric reflections. The data-collection method was tested using InGaN/GaN/AlN multilayers on sapphire substrates, since these exhibit broad features in reciprocal space. The geometry of the scans in reciprocal space required the data to be interpolated onto a Cartesian grid. Several interpolation schemes were investigated, with the results compared with the reciprocal space maps collected using a triple-axis scheme with a point detector. The quality of the interpolated reciprocal space maps depends upon the size and shape of the feature in reciprocal space, the interpolation method used, and the step size of the sample rotation. The method can be extended to three dimensions without an increase in data-collection time.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...