Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
1.
Eur J Heart Fail ; 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014551

RESUMO

AIMS: Lung ultrasound (LUS) is a sensitive tool to assess pulmonary congestion (PC). Few data are available on LUS-PC evaluation in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). The aim of this study was to assess the prevalence and prognostic impact of LUS-PC in patients with severe AS before and after TAVI. METHODS AND RESULTS: We designed a single-centre prospective study in patients referred for TAVI for severe AS (ClinicalTrials.gov identification number: NCT05024942). All patients underwent echocardiography and LUS (according to a simplified 8-zone scanning protocol) the day before and within 72 h after the procedure. The primary endpoint was the composite of all-cause mortality, hospitalization for heart failure and urgent medical visits for worsening dyspnoea at 12-month follow-up. A total of 127 patients were enrolled (mean age 81.1 ± 5.8 years; 54.3% female). Pre-TAVI LUS-PC was documented in 65 patients (51%). After TAVI, the prevalence of LUS-PC significantly decreased as compared to pre-TAVI evaluation, being documented in only 28 patients (22% vs. 51%, p < 0.001) with a median B-lines score of 4 (interquartile range [IQR] 0-11) versus 11 (IQR 6-19) pre-TAVI (p < 0.001). During a median follow-up of 12 (12-17) months, 25 patients (19.6%) met the composite endpoint. On multivariable Cox regression analysis, pre-TAVI LUS-PC was independently associated with cardiovascular events (hazard ratio 2.764, 95% confidence interval 1.114-6.857; p = 0.028). CONCLUSIONS: Lung ultrasonography reveals a high prevalence of PC in patients with severe AS undergoing TAVI, which is significantly reduced by the procedure. Pre-TAVI PC, measured by LUS, is an independent predictor of 1-year clinical outcome.

8.
Catheter Cardiovasc Interv ; 103(7): 1138-1144, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38695165

RESUMO

Following the introduction in the latest European and American guidelines, transcatheter edge-to-edge repair has become a valid alternative to surgery for ineligible patients. Among the available technologies, MitraClip (Abbott) was the first to be introduced for the percutaneous treatment of mitral regurgitation with the edge-to-edge technique. Although its safety and effectiveness has been widely demonstrated, the optimal procedural results are highly dependent from operators' experience. In this manuscript, we provide a full guide of advanced steering maneuvers of MitraClip in different scenarios of transseptal puncture.


Assuntos
Cateterismo Cardíaco , Cateteres Cardíacos , Insuficiência da Valva Mitral , Valva Mitral , Punções , Humanos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Desenho de Equipamento , Septos Cardíacos/cirurgia , Septos Cardíacos/diagnóstico por imagem , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Resultado do Tratamento
9.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599688

RESUMO

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Estudos Multicêntricos como Assunto , Sistema de Registros
12.
Int J Cardiol ; 405: 131934, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38437953

RESUMO

AIMS: T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. METHODS AND RESULTS: The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. CONCLUSIONS: In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. CONDENSED ABSTRACT: The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.


Assuntos
Cateterismo Cardíaco , Sistema de Registros , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Masculino , Feminino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Idoso , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Pessoa de Meia-Idade , Ecocardiografia/métodos
14.
Transplant Rev (Orlando) ; 38(2): 100838, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38417399

RESUMO

BACKGROUND & AIMS: Echocardiographic findings may provide valuable information about the cardiac conditions in cirrhotic patients waiting for liver transplantation (LT). However, data on the ability of the different echocardiographic parameters to predict post-transplant risk of mortality are scarce and heterogeneous. This systematic review evaluates the role of different echocardiographic features as predictors of post-LT mortality. A meta-analysis was also performed according to the observed results. METHODS: A systematic review was conducted according to PRISMA guidelines. Medline (PubMed) database was searched through February 2023 for relevant published original articles reporting the prognostic value of echocardiographic findings associated with outcomes of adult LT recipients. The risk of bias in included articles was assessed using ROBINS-E tool. Methodological quality varied from low to high across the risk of bias domains. RESULTS: Twenty-three studies were identified after the selection process; ten were enrollable for the meta-analyses. According to the results observed, the E/A ratio fashioned as a continuous value (HR = 0.43, 95%CI = 0.25-0.76; P = 0.003), and tricuspid regurgitation (HR = 2.36, 95%CI = 1.05-5.31; P = 0.04) were relevant predicting variables for post-LT death. Other echocardiographic findings failed to merge with statistical relevance. CONCLUSION: Tricuspid regurgitation and left ventricular diastolic dysfunction play a role in the prediction of post-LT death. More studies are needed to clarify further the impact of these echocardiographic features in the transplantation setting.


Assuntos
Cardiopatias , Transplante de Fígado , Insuficiência da Valva Tricúspide , Adulto , Humanos , Transplante de Fígado/efeitos adversos , Ecocardiografia , Prognóstico
17.
Minerva Cardiol Angiol ; 72(2): 172-181, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38088090

RESUMO

BACKGROUND: Paravalvular leakage (PVL) is a common finding after transcatheter aortic valve replacement (TAVR) and affects late clinical outcome. It is more frequent with self-expandable (SE) transcatheter-heart-valve (THV). Few is known about SE-THV expansion after implantation. The purpose is to assess SE-THV frame expansion and its possible influence on PVL. METHODS: We designed a prospective pilot study to assess the time-course of SE-THV frame dimensions and PVL after TAVR. Consecutive patients undergoing TAVR with SE-THV were enrolled. Prosthesis fluoroscopy and echocardiography were prospectively performed immediately after TAVR (T0) and before discharge (T1) to grade PVL. Prosthesis diameters were assessed in 2 fluoroscopic orthogonal views. PVL reduction ≥1+ from T0 to T1 at echocardiography was the primary study endpoint. RESULTS: Twenty-five patients were enrolled. Mean interval between T0 and T1 evaluations was 5 days. Grade 1 or 2 was present in 76% of patients at T0 and in 68% at T1 (P=0.034). A total of 7 patients (28%) improved PVL ≥1 grade from T0 to T1. Differences between T0 and T1 fluoroscopic diameters were not statistically significant. When comparing the diameter changes according to PVL evolution, patients with PVL improvement (as compared with those without) had significantly larger minimum diameter increase at both annulus/inflow (P=0.016) and outflow/distal edge (P=0.027). CONCLUSIONS: PVL may improve in the early days after SE-THV and those patients with PVL improvement may have THV frame expansion. Further studies are needed to confirm such preliminary observations and to establish the clinical relevance of this phenomenon.


Assuntos
Insuficiência da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estudos Prospectivos , Projetos Piloto , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...