Resultados 1 - 20 de 29
Filtrar
1.
MAGMA ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38743376

RESUMO

PURPOSE: To investigate the effect of respiratory motion in terms of signal loss in prostate diffusion-weighted imaging (DWI), and to evaluate the usage of partial Fourier in a free-breathing protocol in a clinically relevant b-value range using both single-shot and multi-shot acquisitions. METHODS: A controlled breathing DWI acquisition was first employed at 3 T to measure signal loss from deep breathing patterns. Single-shot and multi-shot (2-shot) acquisitions without partial Fourier (no pF) and with partial Fourier (pF) factors of 0.75 and 0.65 were employed in a free-breathing protocol. The apparent SNR and ADC values were evaluated in 10 healthy subjects to measure if low pF factors caused low apparent SNR or overestimated ADC. RESULTS: Controlled breathing experiments showed a difference in signal coefficient of variation between shallow and deep breathing. In free-breathing single-shot acquisitions, the pF 0.65 scan showed a significantly (p < 0.05) higher apparent SNR than pF 0.75 and no pF in the peripheral zone (PZ) of the prostate. In the multi-shot acquisitions in the PZ, pF 0.75 had a significantly higher apparent SNR than 0.65 pF and no pF. The single-shot pF 0.65 scan had a significantly lower ADC than single-shot no pF. CONCLUSION: Deep breathing patterns can cause intravoxel dephasing in prostate DWI. For single-shot acquisitions at a b-value of 800 s/mm2, any potential risks of motion-related artefacts at low pF factors (pF 0.65) were outweighed by the increase in signal from a lower TE, as shown by the increase in apparent SNR. In multi-shot acquisitions however, the minimum pF factor should be larger, as shown by the lower apparent SNR at low pF factors.

2.
Magn Reson Imaging ; 110: 96-103, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38631532

RESUMO

PURPOSE: Further acceleration of DWI in diagnostic radiology is desired but challenging mainly due to low SNR in high b-value images and associated bias in quantitative ADC values. Deep learning-based reconstruction and denoising may provide a solution to address this challenge. METHODS: The effects of SNR reduction on ADC bias and variability were investigated using a commercial diffusion phantom and numerical simulations. In the phantom, performance of different reconstruction methods, including conventional parallel (SENSE) imaging, compressed sensing (C-SENSE), and compressed SENSE acceleration with an artificial intelligence deep learning-based technique (C-SENSE AI), was compared at different acceleration factors and flip angles using ROI-based analysis. ADC bias was assessed by Lin's Concordance correlation coefficient (CCC) followed by bootstrapping to calculate confidence intervals (CI). ADC random measurement error (RME) was assessed by the mean coefficient of variation (CV¯) and non-parametric statistical tests. RESULTS: The simulations predicted increasingly negative bias and loss of precision towards lower SNR. These effects were confirmed in phantom measurements of increasing acceleration, for which CCC decreased from 0.947 to 0.279 and CV¯ increased from 0.043 to 0.439, and of decreasing flip angle, for which CCC decreased from 0.990 to 0.063 and CV¯ increased from 0.037 to 0.508. At high acceleration and low flip angle, C-SENSE AI reconstruction yielded best denoised ADC maps. For the lowest investigated flip angle, CCC = {0.630, 0.771 and 0.987} and CV¯={0.508, 0.426 and 0.254} were obtained for {SENSE, C-SENSE, C-SENSE AI}, the improvement by C-SENSE AI being significant as compared to the other methods (CV: p = 0.033 for C-SENSE AI vs. C-SENSE and p < 0.001 for C-SENSE AI vs. SENSE; CCC: non-overlapping CI between reconstruction methods). For the highest investigated acceleration factor, CCC = {0.479,0.926,0.960} and CV¯={0.519,0.119,0.118} were found, confirming the reduction of bias and RME by C-SENSE AI as compared to C-SENSE (by trend) and to SENSE (CV: p < 0.001; CCC: non-overlapping CI). CONCLUSION: ADC bias and random measurement error in DWI at low SNR, typically associated with scan acceleration, can be effectively reduced by deep-learning based C-SENSE AI reconstruction.


Assuntos
Aprendizado Profundo , Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Razão Sinal-Ruído , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Humanos , Reprodutibilidade dos Testes , Algoritmos , Simulação por Computador
3.
NMR Biomed ; : e5147, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561247

RESUMO

Partial Fourier encoding is popular in single-shot (ss) diffusion-weighted (DW) echo planar imaging (EPI) because it enables a shorter echo time (TE) and, hence, improves the signal-to-noise-ratio. Motion during diffusion encoding causes k-space shifting and dispersion, which compromises the quality of the homodyne reconstruction. This work provides a comprehensive understanding of the artifacts in homodyne reconstruction of partial Fourier ss-DW-EPI data in the presence of motion-induced phase and proposes the motion-induced phase-corrected homodyne (mpc-hdyne) reconstruction method to ameliorate these artifacts. Simulations with different types of motion-induced phase were performed to provide an understanding of the potential artifacts that occur in the homodyne reconstruction of partial Fourier ss-DW-EPI data. To correct for the artifacts, the mpc-hdyne reconstruction is proposed. The algorithm recenters k-space, updates the partial Fourier factor according to detected global k-space shifts, and removes low-resolution nonlinear phase before the conventional homodyne reconstruction. The mpc-hdyne reconstruction is tested on both simulation and in vivo data. Motion-induced phase can cause signal overestimation, worm artifacts, and signal loss in partial Fourier ss-DW-EPI data with the conventional homodyne reconstruction. Simulation and in vivo data showed that the proposed mpc-hdyne reconstruction ameliorated artifacts, yielding higher quality DW images compared with conventional homodyne reconstruction. Based on the understanding of the artifacts in homodyne reconstruction of partial Fourier ss-DW-EPI data, the mpc-hdyne reconstruction was proposed and showed superior performance compared with the conventional homodyne reconstruction on both simulation and in vivo data.

4.
Eur J Radiol ; 175: 111445, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38537605

RESUMO

PURPOSE: To evaluate the feasibility of a free-breathing sequence (4D FreeBreathing) combined with Compressed SENSE in dynamic contrast-enhanced pancreatic MRI and compare it with a breath-holding sequence (eTHRIVE). METHOD: Patients who underwent pancreatic MRI, either eTHRIVE or 4D FreeBreathing, from April 2022 to November 2023 were included in this retrospective study. Two radiologists, who were unaware of the scan sequence, independently and randomly reviewed the images at the precontrast, pancreatic, portal venous, and equilibrium phases and assigned confidence scores for motion and streaking artifacts, pancreatic sharpness, and overall image quality using a 5-point scale. Furthermore, the radiologists assessed the appropriateness of the scan timing of the pancreatic phase. Mann-Whitney U and Fisher's exact tests were conducted to compare the confidence scores and adequacy of the pancreatic phase scan timing between eTHRIVE and 4D FreeBreathing. RESULTS: Overall, 48 patients (median age, 71 years; interquartile range, 64-77 years; 24 women) were included. Among them, 20 patients (42%) were scanned using 4D FreeBreathing. The 4D FreeBreathing showed moderate streaking artifact but improved motion artifact (P <.001-.17) at all phases. Pancreatic sharpness and overall image quality were almost comparable between two sequences (P = .17-.96). All 20 examinations in 4D FreeBreathing showed appropriate pancreatic phase images, but only 16 (57%; P <.001 for reviewer 1) and 18 (64%; P = .003 for reviewer 2) examinations showed it in eTHRIVE. CONCLUSION: The use of 4D FreeBreathing combined with Compressed SENSE was feasible in pancreatic MRI and provided appropriate pancreatic phase images in all examinations.


Assuntos
Meios de Contraste , Estudos de Viabilidade , Imageamento por Ressonância Magnética , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Artefatos , Respiração , Aumento da Imagem/métodos , Suspensão da Respiração , Compressão de Dados/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Pancreatopatias/diagnóstico por imagem
5.
Tomography ; 9(5): 1839-1856, 2023 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-37888738

RESUMO

Cardiac motion causes unpredictable signal loss in respiratory-triggered diffusion-weighted magnetic resonance imaging (DWI) of the liver, especially inside the left lobe. The left liver lobe may thus be frequently neglected in the clinical evaluation of liver DWI. In this work, a data-driven algorithm that relies on the statistics of the signal in the left liver lobe to mitigate the motion-induced signal loss is presented. The proposed data-driven algorithm utilizes the exclusion of severely corrupted images with subsequent spatially dependent image scaling based on a signal-loss model to correctly combine the multi-average diffusion-weighted images. The signal in the left liver lobe is restored and the liver signal is more homogeneous after applying the proposed algorithm. Furthermore, overestimation of the apparent diffusion coefficient (ADC) in the left liver lobe is reduced. The proposed algorithm can therefore contribute to reduce the motion-induced bias in DWI of the liver and help to increase the diagnostic value of DWI in the left liver lobe.


Assuntos
Artefatos , Fígado , Estudos Retrospectivos , Reprodutibilidade dos Testes , Fígado/diagnóstico por imagem , Movimento (Física) , Imagem de Difusão por Ressonância Magnética/métodos
6.
Radiology ; 308(3): e230427, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37750774

RESUMO

Background Deep learning (DL) reconstructions can enhance image quality while decreasing MRI acquisition time. However, DL reconstruction methods combined with compressed sensing for prostate MRI have not been well studied. Purpose To use an industry-developed DL algorithm to reconstruct low-resolution T2-weighted turbo spin-echo (TSE) prostate MRI scans and compare these with standard sequences. Materials and Methods In this prospective study, participants with suspected prostate cancer underwent prostate MRI with a Cartesian standard-resolution T2-weighted TSE sequence (T2C) and non-Cartesian standard-resolution T2-weighted TSE sequence (T2NC) between August and November 2022. Additionally, a low-resolution Cartesian DL-reconstructed T2-weighted TSE sequence (T2DL) with compressed sensing DL denoising and resolution upscaling reconstruction was acquired. Image sharpness was assessed qualitatively by two readers using a five-point Likert scale (from 1 = nondiagnostic to 5 = excellent) and quantitatively by calculating edge rise distance. The Friedman test and one-way analysis of variance with post hoc Bonferroni and Tukey tests, respectively, were used for group comparisons. Prostate Imaging Reporting and Data System (PI-RADS) score agreement between sequences was compared by using Cohen κ. Results This study included 109 male participants (mean age, 68 years ± 8 [SD]). Acquisition time of T2DL was 36% and 29% lower compared with that of T2C and T2NC (mean duration, 164 seconds ± 20 vs 257 seconds ± 32 and 230 seconds ± 28; P < .001 for both). T2DL showed improved image sharpness compared with standard sequences using both qualitative (median score, 5 [IQR, 4-5] vs 4 [IQR, 3-4] for T2C and 4 [IQR, 3-4] for T2NC; P < .001 for both) and quantitative (mean edge rise distance, 0.75 mm ± 0.39 vs 1.15 mm ± 0.68 for T2C and 0.98 mm ± 0.65 for T2NC; P < .001 and P = .01) methods. PI-RADS score agreement between T2NC and T2DL was excellent (κ range, 0.92-0.94 [95% CI: 0.87, 0.98]). Conclusion DL reconstruction of low-resolution T2-weighted TSE sequences enabled accelerated acquisition times and improved image quality compared with standard acquisitions while showing excellent agreement with conventional sequences for PI-RADS ratings. Clinical trial registration no. NCT05820113 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Turkbey in this issue.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Humanos , Masculino , Idoso , Imageamento por Ressonância Magnética , Estudos Prospectivos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia
7.
Pediatr Radiol ; 53(7): 1285-1299, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36255456

RESUMO

Longer examination time, need for anesthesia in smaller children and the inability of most children to hold their breath are major limitations of MRI in pediatric body imaging. Fortunately, with technical advances, many new and upcoming MRI sequences are overcoming these limitations. Advances in data acquisition and k-space sampling methods have enabled sequences with improved temporal and spatial resolution, and minimal artifacts. Sequences to minimize movement artifacts mainly utilize radial k-space filling, and examples include the stack-of-stars method for T1-weighted imaging and the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER)/BLADE method for T2-weighted imaging. Similarly, the sequences with improved temporal resolution and the ability to obtain multiple phases in a single breath-hold in dynamic imaging mainly use some form of partial k-space filling method. New sequences use a variable combination of data sampling methods like compressed sensing, golden-angle radial k-space filling, parallel imaging and partial k-space filling to achieve free-breathing, faster sequences that could be useful for pediatric abdominal and thoracic imaging. Simultaneous multi-slice method has improved diffusion-weighted imaging (DWI) with reduction in scan time and artifacts. In this review, we provide an overview of data sampling methods like parallel imaging, compressed sensing, radial k-space sampling, partial k-space sampling and simultaneous multi-slice. This is followed by newer available and upcoming sequences for T1-, T2- and DWI based on these other advances. We also discuss the Dixon method and newer approaches to reducing metal artifacts.


Assuntos
Meios de Contraste , Processamento de Imagem Assistida por Computador , Humanos , Criança , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Respiração , Artefatos , Imageamento Tridimensional , Aumento da Imagem/métodos
8.
Magn Reson Med ; 89(1): 144-160, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36098347

RESUMO

PURPOSE: To assess the effect of respiratory motion and cardiac driven pulsation in renal DWI and to examine asymmetrical velocity-compensated diffusion encoding waveforms for robust ADC mapping in the kidneys. METHODS: The standard monopolar Stejskal-Tanner pulsed gradient spin echo (pgse) and the asymmetric bipolar velocity-compensated (asym-vc) diffusion encoding waveforms were used for coronal renal DWI at 3T. The robustness of the ADC quantification in the kidneys was tested with the aforementioned waveforms in respiratory-triggered and breath-held cardiac-triggered scans at different trigger delays in 10 healthy subjects. RESULTS: The pgse waveform showed higher ADC values in the right kidney at short trigger delays in comparison to longer trigger delays in the respiratory triggered scans when the diffusion gradient was applied in the feet-head (FH) direction. The coefficient of variation over all respiratory trigger delays, averaged over all subjects was 0.15 for the pgse waveform in the right kidney when diffusion was measured in the FH direction; the corresponding coefficient of variation for the asym-vc waveform was 0.06. The effect of cardiac driven pulsation was found to be small in comparison to the effect of respiratory motion. CONCLUSION: Short trigger delays in respiratory-triggered scans can cause higher ADC values in comparison to longer trigger delays in renal DWI, especially in the right kidney when diffusion is measured in the FH direction. The asym-vc waveform can reduce ADC variation due to respiratory motion in respiratory-triggered scans at the cost of reduced SNR compared to the pgse waveform.


Assuntos
Imagem de Difusão por Ressonância Magnética , Rim , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Movimento (Física) , Rim/diagnóstico por imagem , Coração/diagnóstico por imagem , Difusão , Reprodutibilidade dos Testes
9.
Cancers (Basel) ; 14(23)2022 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-36497223

RESUMO

BACKGROUND: To assess the performance of prospectively accelerated and deep learning (DL) reconstructed T2-weighted (T2w) imaging in volunteers and patients with histologically proven prostate cancer (PCa). METHODS: Prospectively undersampled T2w datasets were acquired with acceleration factors of 1.7 (reference), 3.4 and 4.8 in 10 healthy volunteers and 23 patients with histologically proven PCa. Image reconstructions using compressed SENSE (C-SENSE) and a combination of C-SENSE and DL-based artificial intelligence (C-SENSE AI) were analyzed. Qualitative image comparison was performed using a 6-point Likert scale (overall image quality, noise, motion artifacts, lesion detection, diagnostic certainty); the T2 and PI-RADS scores were compared between the two reconstructions. Additionally, quantitative image parameters were assessed (apparent SNR, apparent CNR, lesion size, line profiles). RESULTS: All C-SENSE AI-reconstructed images received a significantly higher qualitative rating compared to the C-SENSE standard images. Analysis of the quantitative parameters supported this finding, with significantly higher aSNR and aCNR. The line profiles demonstrated a significantly steeper signal change at the border of the prostatic lesion and the adjacent normal tissue in the C-SENSE AI-reconstructed images, whereas the T2 and PI-RADS scores as well as the lesion size did not differ. CONCLUSION: In this prospective study, we demonstrated the clinical feasibility of a novel C-SENSE AI reconstruction enabling a 58% acceleration in T2w imaging of the prostate while obtaining significantly better image quality.

10.
Eur Radiol ; 32(12): 8376-8385, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35751695

RESUMO

OBJECTIVES: To evaluate a compressed sensing artificial intelligence framework (CSAI) to accelerate MRI acquisition of the ankle. METHODS: Thirty patients were scanned at 3T. Axial T2-w, coronal T1-w, and coronal/sagittal intermediate-w scans with fat saturation were acquired using compressed sensing only (12:44 min, CS), CSAI with an acceleration factor of 4.6-5.3 (6:45 min, CSAI2x), and CSAI with an acceleration factor of 6.9-7.7 (4:46 min, CSAI3x). Moreover, a high-resolution axial T2-w scan was obtained using CSAI with a similar scan duration compared to CS. Depiction and presence of abnormalities were graded. Signal-to-noise and contrast-to-noise were calculated. Wilcoxon signed-rank test and Cohen's kappa were used to compare CSAI with CS sequences. RESULTS: The correlation was perfect between CS and CSAI2x (κ = 1.0) and excellent for CS and CSAI3x (κ = 0.86-1.0). No significant differences were found for the depiction of structures between CS and CSAI2x and the same abnormalities were detected in both protocols. For CSAI3x the depiction was graded lower (p ≤ 0.001), though most abnormalities were also detected. For CSAI2x contrast-to-noise fluid/muscle was higher compared to CS (p ≤ 0.05), while no differences were found for other tissues. Signal-to-noise and contrast-to-noise were higher for CSAI3x compared to CS (p ≤ 0.05). The high - resolution axial T2-w sequence specifically improved the depiction of tendons and the tibial nerve (p ≤ 0.005). CONCLUSIONS: Acquisition times can be reduced by 47% using CSAI compared to CS without decreasing diagnostic image quality. Reducing acquisition times by 63% is feasible but should be reserved for specific patients. The depiction of specific structures is improved using a high-resolution axial T2-w CSAI scan. KEY POINTS: • Prospective study showed that CSAI enables reduction in acquisition times by 47% without decreasing diagnostic image quality. • Reducing acquisition times by 63% still produces images with an acceptable diagnostic accuracy but should be reserved for specific patients. • CSAI may be implemented to scan at a higher resolution compared to standard CS images without increasing acquisition times.


Assuntos
Artefatos , Aprendizado Profundo , Humanos , Razão Sinal-Ruído , Tornozelo/diagnóstico por imagem , Estudos Prospectivos , Inteligência Artificial , Imageamento por Ressonância Magnética/métodos , Aceleração , Imageamento Tridimensional/métodos
11.
Invest Radiol ; 57(7): 470-477, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35136004

RESUMO

OBJECTIVE: Robust dynamic contrast-enhanced T1-weighted images are crucial for accurate detection and categorization of focal liver lesions in liver/abdominal magnetic resonance imaging (MRI). As optimal dynamic imaging usually requires multiple breath-holds, its inherent susceptibility to motion artifacts frequently results in degraded image quality in incompliant patients. Because free-breathing imaging may overcome this drawback, the intention of this study was to evaluate a dynamic MRI sequence acquired during free breathing using the variable density, elliptical centric golden angle radial stack-of-stars radial sampling scheme, which so far has not been implemented in 4-dimensional applications. MATERIALS AND METHODS: In a prospective pilot study, 27 patients received a routine abdominal MRI protocol including the prototype free-breathing sequence (4DFreeBreathing) for dynamic imaging. This enables more convenient and faster reconstruction through variable density, elliptical centric golden angle radial stack-of-stars without the use of additional reconstruction hardware, and even higher motion robustness through soft-gating. A standard breath-hold sequence performed subsequently served as reference standard. Of the continuous dynamic data sets, each dynamic phase was analyzed regarding image quality, motion artifacts and vessel conspicuity using 5-point Likert scales. Furthermore, correct timing of the late arterial phase was compared with the preexaminations. RESULTS: 4DFreeBreathing delivered motion-free dynamic images with high temporal resolution in each subject. Overall image quality scores were rated good or excellent for 4DFreeBreathing and the gold standard without significant differences (P = 0.34). There were significantly less motion artifacts in the 4DFreeBreathing sequence (P < 0.0001), whereas vessel conspicuity in each dynamic phase was comparable for both groups (P = 0.45, P > 0.99, P = 0.22, respectively). Correct timing of the late arterial phase could be achieved in 27 of 27 (100%) examinations using 4DFreeBreathing versus 35 of 53 (66%) preexaminations using gold standard (P < 0.001). CONCLUSION: The benefit of convenient and fast image reconstruction combined with the superiority in motion robustness and timing compared with standard breath hold sequences renders 4DFreeBreathing an attractive alternative to existing free-breathing techniques in dynamic liver MRI.


Assuntos
Meios de Contraste , Aumento da Imagem , Artefatos , Estudos de Viabilidade , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Projetos Piloto , Estudos Prospectivos , Respiração
12.
Magn Reson Imaging ; 87: 1-6, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34808306

RESUMO

OBJECTIVES: To prospectively evaluate an L1 regularized iterative SENSE reconstruction (L1-R SENSE) to eliminate band-like artifacts frequently seen with parallel imaging (SENSE) at high acceleration factors in high resolution diffusion weighted magnetic resonance imaging of the pancreas. METHODS: Fourteen patients with pancreatic ductal adenocarcinoma (PDAC) underwent respiratory triggered DWI ss-EPI at a resolution of 2.5 × 2.5 × 3 mm3 with uniform undersampling in the phase encoding direction (AP axis) with an acceleration factor of 4. Data were reconstructed using the standard SENSE reconstruction routine of the vendor and an iterative SENSE reconstruction employing L1 regularization after a wavelet sparsifying transformation (L1-R SENSE). Retrospective reconstruction of the data with a lower number of averages was performed using both reconstruction methods. Two radiologists independently assessed noise artifacts, anatomical details and image quality (IQ) subjectively with a 4-point scale. Apparent diffusion coefficient (ADC) and covariance (CV) of ADC estimated from images reconstructed at a different number of averages for PDAC and the normal pancreas were assessed. RESULTS: L1-R SENSE resulted in higher IQ and less noise artifacts than SENSE. Anatomical details were significantly higher for SENSE in one reader. Mean ADC of PDAC and normal pancreas were significantly higher for L1-R SENSE than SENSE. L1-R SENSE revealed lower CV of ADC for normal pancreas compared to SENSE, whereas no difference was noted for PDAC. CONCLUSION: Compared with traditional SENSE reconstruction, L1-R SENSE effectively reduces band-like noise and improves the robustness of the ADC estimation from acquisitions using single-shot DW-EPI of the pancreas.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Artefatos , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Humanos , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
MAGMA ; 35(5): 827-841, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34894335

RESUMO

OBJECTIVE : To experimentally characterize the effectiveness of a gradient nonlinearity correction method in removing ADC bias for different motion-compensated diffusion encoding waveforms. METHODS: The diffusion encoding waveforms used were the standard monopolar Stejskal-Tanner pulsed gradient spin echo (pgse) waveform, the symmetric bipolar velocity-compensated waveform (sym-vc), the asymmetric bipolar velocity-compensated waveform (asym-vc) and the asymmetric bipolar partial velocity-compensated waveform (asym-pvc). The effectiveness of the gradient nonlinearity correction method using the spherical harmonic expansion of the gradient coil field was tested with the aforementioned waveforms in a phantom and in four healthy subjects. RESULTS: The gradient nonlinearity correction method reduced the ADC bias in the phantom experiments for all used waveforms. The range of the ADC values over a distance of ± 67.2 mm from isocenter reduced from 1.29 × 10-4 to 0.32 × 10-4 mm2/s for pgse, 1.04 × 10-4 to 0.22 × 10-4 mm2/s for sym-vc, 1.22 × 10-4 to 0.24 × 10-4 mm2/s for asym-vc and 1.07 × 10-4 to 0.11 × 10-4 mm2/s for asym-pvc. The in vivo results showed that ADC overestimation due to motion or bright vessels can be increased even further by the gradient nonlinearity correction. CONCLUSION: The investigated gradient nonlinearity correction method can be used effectively with various motion-compensated diffusion encoding waveforms. In coronal liver DWI, ADC errors caused by motion and residual vessel signal can be increased even further by the gradient nonlinearity correction.


Assuntos
Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Movimento (Física)
14.
Eur Radiol ; 31(11): 8399-8407, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33884471

RESUMO

OBJECTIVES: To compare the image quality and diagnostic performance of 2D MRCP to those of breath-hold 3D MRCP using compressed sensing (CS-MRCP) and gradient and spin-echo (GRASE-MRCP) at 3T. METHODS: From January to November 2018, patients who underwent pancreatobiliary MRI including 2D MRCP and two breath-hold 3D MRCP using CS and GRASE at 3T were included. Three radiologists independently evaluated image quality, motion artifact, and pancreatic cyst conspicuity. Diagnostic performance was assessed for bile duct anatomic variation, bile duct, and pancreatic diseases using a composite algorithm as reference standards. Pancreatic lesion detectability and conspicuity were evaluated using JAFROC and generalized estimating equation analysis. RESULTS: One hundred patients (male = 50) were included. Bile duct anatomic variation, bile duct and pancreatic diseases were present in respectively 31, 15, and 79 patients. Breath-hold 3D MRCP provided better image quality than 2D MRCP (3.5 ± 0.6 in 2D MRCP; 4.0 ± 0.7 in GRASE-MRCP and 3.9 ± 0.8 in CS-MRCP, p < 0.001 for both). There was no difference in motion artifact between 2D and breath-hold 3D MRCP (p = 0.1). Breath-hold 3D CS-MRCP provided better pancreatic cyst conspicuity than 2D MRCP (2.7 [95% CI: 2.5-3.0] vs. 2.3 [95% CI: 2.1-2.5], p = 0.001). There were no significant differences between the diagnostic performance of the three sequences in the detection of bile duct anatomic variation or pancreatic lesions (p > 0.05). CONCLUSION: Breath-hold 3D MRCP with GRASE or CS can provide better image quality than 2D MRCP in a comparable scan time. KEY POINTS: • Breath-hold 3D MRCP using compressed sensing (CS) or gradient and spin-echo (GRASE) provided a better image quality with less image blurring than 2D MRCP. • There were no significant differences between 2D MRCP and breath-hold 3D MRCP in either motion artifact or the number of non-diagnostic exams. • There were no significant differences between 2D MRCP and either type of breath-hold 3D MRCP in the diagnosis of bile duct anatomic variation or detection of pancreatic lesions.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Pancreatopatias , Artefatos , Suspensão da Respiração , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Masculino , Pancreatopatias/diagnóstico por imagem
15.
Acad Radiol ; 28 Suppl 1: S234-S243, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33390324

RESUMO

RATIONALE AND OBJECTIVES: To investigate the effects of a reduced field-of-view (rFOV) acquisition in diffusion-weighted magnetic resonance imaging of the pancreas. MATERIALS AND METHODS: We enrolled 153 patients who underwent routine clinical MRI work-up including respiratory-triggered diffusion-weighted single-shot echo-planar imaging (DWI) with full field-of-view (fFOV, 3 × 3 × 4 mm3 voxel size) and reduced field-of-view (rFOV, 2.5 × 2.5 × 3 mm3 voxel size) for suspected pancreatic pathology. Two experienced radiologists were asked to subjectively rate (Likert Scale 1-4) image quality (overall image quality, lesion conspicuity, anatomical detail, artifacts). In addition, quantitative image parameters were assessed (apparent diffusion coefficient, apparent signal to noise ratio, apparent contrast to noise ratio [CNR]). RESULTS: All subjective metrics of image quality were rated in favor of rFOV DWI images compared to fFOV DWI images with substantial-to-high inter-rater reliability. Calculated ADC values of normal pancreas, pancreatic pathologies and reference tissues revealed no differences between both sequences. Whereas the apparent signal to noise ratio was higher in fFOV images, apparent CNR was higher in rFOV images. CONCLUSION: rFOV DWI provides higher image quality and apparent CNR values, favorable in the analysis of pancreatic pathologies.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Artefatos , Humanos , Pâncreas/diagnóstico por imagem , Reprodutibilidade dos Testes
16.
Dysphagia ; 36(1): 41-53, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32200444

RESUMO

Swallowing muscle strength exercises are effective in restoring swallowing function. In order to perform the exercises with progressive load, the swallow exercise aid (SEA) was developed. Precise knowledge on which muscles are activated with swallowing exercises, especially with the SEA, is lacking. This knowledge would aid in optimizing the training program to target the relevant swallowing muscles, if necessary. Three healthy volunteers performed the three SEA exercises (chin tuck against resistance, jaw opening against resistance and effortful swallow) and three conventional exercises [conventional effortful swallow (cES), Shaker and Masako] in supine position inside an MRI scanner. Fast muscle functional MRI scans (generating quantitative T2-maps) were made immediately before and after the exercises. Median T2 values at rest and after exercise were compared to identify activated muscles. After the three SEA exercises, the suprahyoid, infrahyoid, sternocleidomastoid, and lateral pterygoid muscles showed significant T2 value increase. After the Shaker, the lateral pterygoid muscles did not show such an increase, but the three other muscle groups did. The cES and Masako caused no significant increase in any of these muscle groups. During conventional (Shaker) exercises, the suprahyoid, infrahyoid, and sternocleidomastoid muscles are activated. During the SEA exercises, the suprahyoid, infrahyoid, sternocleidomastoid, and lateral pterygoid muscles are activated. The findings of this explorative study further support the potential of the SEA to improve swallowing rehabilitation.


Assuntos
Transtornos de Deglutição , Deglutição , Eletromiografia , Terapia por Exercício , Humanos , Imageamento por Ressonância Magnética , Músculos do Pescoço
17.
Eur J Radiol ; 129: 109110, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32559592

RESUMO

PURPOSE: To evaluate the diagnostic value of fiber tractography and diffusivity analysis generated from 3D diffusion-weighted (DW) sequences for preoperative assessment of benign peripheral nerve sheath tumors. METHOD: MR imaging at 3 T was performed in 22 patients (mean age 41.9 ±â€¯17.1y, 13 women) with histologically confirmed schwannomas (N = 18) and histologically confirmed neurofibromas (N = 11), including a 3D DW turbo spin echo sequence with fat suppression. Diffusion tensor parameters were computed and fiber tracks were determined. Evaluation was performed by two radiologists and one orthopedic surgeon blinded for final diagnosis. Mean diffusivity was computed to allow further assessment of tumor microstructure. Preoperative fascicle visualization was graded, fascicles were categorized regarding anatomical location and amount of fascicles surrounding the tumor. The agreement of imaging findings with intraoperative findings was assessed. RESULTS: On 78.3 % of the DTI images, the fascicle visualization was rated as good or very good. Tractography differences were observed in schwannomas and neurofibromas, showing schwannomas to be significantly more often located eccentrically to the nerve (94.8 %) than neurofibromas (0 %, P < 0.01). Fascicles were significantly more often continuous (87.5 %) in schwannomas, while in neurofibromas, none of the tracks was graded to be continuous (0 %, P = 0.014). A substantial agreement between fiber tracking and surgical anatomy was found regarding the fascicle courses surrounding the tumor (κ = 0.78). Mean diffusivity of schwannomas (1.5 ±â€¯0.2 × 10-3 mm2/s) was significantly lower than in neurofibromas (1.8 ±â€¯0.2 × 10-3 mm2/s; P < 0.001). The Youden index showed an optimal cutoff at 1.7 × 10-3 mm2/s (sensitivity, 0.91; specificity, 0.78; J = 0.69). CONCLUSIONS: Preoperative diffusion tensor imaging allowed to accurately differentiate between schwannomas and neurofibromas and to describe their location in relation to the nerve fascicles for preoperative planning.


Assuntos
Imagem de Tensor de Difusão/métodos , Neoplasias de Bainha Neural/diagnóstico por imagem , Neurilemoma/diagnóstico por imagem , Neurofibroma/diagnóstico por imagem , Cuidados Pré-Operatórios/métodos , Adulto , Diagnóstico Diferencial , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade
18.
Tomography ; 6(2): 86-92, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32548284

RESUMO

The presented analysis of multisite, multiplatform clinical oncology trial data sought to enhance quantitative utility of the apparent diffusion coefficient (ADC) metric, derived from diffusion-weighted magnetic resonance imaging, by reducing technical interplatform variability owing to systematic gradient nonlinearity (GNL). This study tested the feasibility and effectiveness of a retrospective GNL correction (GNC) implementation for quantitative quality control phantom data, as well as in a representative subset of 60 subjects from the ACRIN 6698 breast cancer therapy response trial who were scanned on 6 different gradient systems. The GNL ADC correction based on a previously developed formalism was applied to trace-DWI using system-specific gradient-channel fields derived from vendor-provided spherical harmonic tables. For quantitative DWI phantom images acquired in typical breast imaging positions, the GNC improved interplatform accuracy from a median of 6% down to 0.5% and reproducibility of 11% down to 2.5%. Across studied trial subjects, GNC increased low ADC (<1 µm2/ms) tumor volume by 16% and histogram percentiles by 5%-8%, uniformly shifting percentile-dependent ADC thresholds by ∼0.06 µm2/ms. This feasibility study lays the grounds for retrospective GNC implementation in multiplatform clinical imaging trials to improve accuracy and reproducibility of ADC metrics used for breast cancer treatment response prediction.


Assuntos
Neoplasias da Mama , Mama , Imagem de Difusão por Ressonância Magnética , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Dinâmica não Linear , Reprodutibilidade dos Testes , Estudos Retrospectivos
19.
Korean J Radiol ; 20(12): 1597-1615, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31854148

RESUMO

Magnetic resonance imaging (MRI) plays an important role in abdominal imaging. The high contrast resolution offered by MRI provides better lesion detection and its capacity to provide multiparametric images facilitates lesion characterization more effectively than computed tomography. However, the relatively long acquisition time of MRI often detrimentally affects the image quality and limits its accessibility. Recent developments have addressed these drawbacks. Specifically, multiphasic acquisition of contrast-enhanced MRI, free-breathing dynamic MRI using compressed sensing technique, simultaneous multi-slice acquisition for diffusion-weighted imaging, and breath-hold three-dimensional magnetic resonance cholangiopancreatography are recent notable advances in this field. This review explores the aforementioned state-of-the-art techniques by focusing on their clinical applications and potential benefits, as well as their likely future direction.


Assuntos
Abdome/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Artefatos , Meios de Contraste/química , Gadolínio DTPA/química , Humanos , Imageamento Tridimensional , Respiração
20.
PLoS One ; 14(11): e0224988, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31730658

RESUMO

OBJECTIVES: To evaluate proton density fat fraction (PDFF) and T2* measurements of the liver with combined parallel imaging (sensitivity encoding, SENSE) and compressed sensing (CS) accelerated chemical shift encoding-based water-fat separation. METHODS: Six-echo Dixon imaging was performed in the liver of 89 subjects. The first acquisition variant used acceleration based on SENSE with a total acceleration factor equal to 2.64 (acquisition labeled as SENSE). The second acquisition variant used acceleration based on a combination of CS with SENSE with a total acceleration factor equal to 4 (acquisition labeled as CS+SENSE). Acquisition times were compared between acquisitions and proton density fat fraction (PDFF) and T2*-values were measured and compared separately for each liver segment. RESULTS: Total scan duration was 14.5 sec for the SENSE accelerated image acquisition and 9.3 sec for the CS+SENSE accelerated image acquisition. PDFF and T2* values did not differ significantly between the two acquisitions (paired Mann-Whitney and paired t-test P>0.05 in all cases). CS+SENSE accelerated acquisition showed reduced motion artifacts (1.1%) compared to SENSE acquisition (12.3%). CONCLUSION: CS+SENSE accelerates liver PDFF and T2*mapping while retaining the same quantitative values as an acquisition using only SENSE and reduces motion artifacts.


Assuntos
Aceleração , Adiposidade , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Prótons , Adulto , Idoso , Idoso de 80 Anos ou mais , Fígado Gorduroso/diagnóstico por imagem , Fígado Gorduroso/patologia , Feminino , Hemossiderose/diagnóstico por imagem , Hemossiderose/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...