Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
Radiother Oncol ; 190: 110048, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38070686

RESUMO

AIM: The current work aimed to investigate the clinical benefit of radiotherapy in patients with metastatic non-small cell lung cancer (NSCLC) developing acquired resistance to immune checkpoint inhibitors. METHOD: We report on a pooled, two-institution, phase II single-arm prospective cohort study. The study included patients with stage IV NSCLC who showed progression of one or more measurable lesions under anti-PD-(L)1 inhibition alone, after initially having achieved at least stable disease. Hypofractionated radiotherapy (hRT) of one to four metastases was performed, while one or more lesions were kept untreated. Following hRT, treatment with immune checkpoint inhibitors was continued unchanged until further evidence of tumor progression or unacceptable toxicity. Primary endpoint of the pooled analysis was progression-free survival (PFS), secondary endpoints included overall survival (OS) and toxicity. RESULTS: A total of 48 patients were enrolled: mean age was 67.1 ± 9.3 years, 50 % were male and 72.9 % were PD-L1 positive. Immunotherapy was in 95.8 % of patients the first or second line therapy at time of enrollment. hRT was performed to one (93.8 % of cases) or more lesions (median total dose: 27.5 Gy, median 6.5 Gy/fraction). Forty-five patients (93.8 %) were able to continue immunotherapy for a median of 6.2 months following hRT. Median PFS was 4.4 months, with 62.5 % disease control at three months and 37.5 % at six months. Median OS was 14.9 months. Severe adverse events (grade ≥ 2) were reported in 12 cases (25 %), of which none were radiotherapy-related and four were immunotherapy-related. Salvage therapy consisted of chemotherapy (48.8 %) or repeated irradiation (21.9 %). No further tumor treatment was performed in 29.3 % of patients. CONCLUSIONS: The current pooled analysis is a prospective evaluation of the role of radiation therapy for metastatic NSCLC in the setting of newly acquired immunotherapy resistance. Hypofractionated radiotherapy can support the outcome of immune checkpoint inhibitors and thus allow continuation of treatment for a relevant amount of time despite initial tumor progression.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/tratamento farmacológico , Inibidores de Checkpoint Imunológico/efeitos adversos , Estudos Prospectivos , Imunoterapia/efeitos adversos , Antígeno B7-H1/metabolismo , Ensaios Clínicos Fase II como Assunto
2.
Artigo em Inglês | MEDLINE | ID: mdl-38039597

RESUMO

Cardiovascular diseases have cast a significant negative impact on the lives of millions worldwide. Over the years, extensive efforts have been dedicated to enhancing diagnostic and prognostic tools for these diseases. A growing body of evidence indicates that the angiotensin convertase enzyme (ACE) and the angiotensin convertase enzyme 2 (ACE2), and angiotensin peptide levels could hold a pivotal role in assisting clinicians with the management of cardiovascular conditions, notably hypertension and heart failure. However, despite the considerable body of knowledge in this domain, a void remains in the field of analytical methodologies for these molecules. In this study, we present a fully validated LC-MS/MS method for the precise quantitation of plasma angiotensin (1-7), (1-8), (1-9), and (1-10), following the guidelines set by the Clinical and Laboratory Standards Institute (CLSI). Our method not only enables the accurate quantification of angiotensin peptides but also provides a means to assess ACE and ACE2 activity. Remarkably, our method achieved a Lower Limit of Measurement Interval (LLMI) as low as 5 pg/mL. This has enabled the detection of angiotensin (1-7), (1-8), (1-9) and (1-10) and the accurate quantitation of angiotensin (1-7), (1-8) and (1-10) in all analyzed groups, including healthy controls, patients with high blood pressure, and patients with chronic kidney disease. To our knowledge, our method represents the most sensitive approach allowing for simultaneous quantitation of these four angiotensin peptides. A distinct advantage of our method, when compared to immunoassays, is its high sensitivity combined with comprehensive chromatographic separation of all currently known angiotensin peptides. This combination translates to an exceptional level of selectivity, underscoring the value and potential of our methodology in advancing cardiovascular disease research.


Assuntos
Doenças Cardiovasculares , Espectrometria de Massa com Cromatografia Líquida , Fragmentos de Peptídeos , Humanos , Cromatografia Líquida/métodos , Enzima de Conversão de Angiotensina 2 , Espectrometria de Massas em Tandem/métodos , Angiotensina I , Peptídeos , Angiotensina II
3.
Kidney Int ; 105(2): 338-346, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37918791

RESUMO

Precise determination of circulating parathyroid hormone (PTH) concentration is crucial to diagnose and manage various disease conditions, including the chronic kidney disease-mineral and bone disorder. However, the lack of standardization in PTH assays is challenging for clinicians, potentially leading to medical errors because the different assays do not provide equivalent results and use different reference ranges. Here, we aimed to evaluate the impact of recalibrating PTH immunoassays by means of a recently developed LC-MS/MS method as the reference. Utilizing a large panel of pooled plasma samples with PTH concentrations determined by the LC-MS/MS method calibrated with the World Health Organization (WHO) 95/646 International Standard, five PTH immunoassays were recalibrated. The robustness of this standardization was evaluated over time using different sets of samples. The recalibration successfully reduced inter-assay variability with harmonization of PTH measurements across different assays. By recalibrating the assays based on the WHO 95/646 International Standard, we demonstrated the feasibility for standardizing PTH measurement results and adopting common reference ranges for PTH assays, facilitating a more consistent interpretation of PTH values. The recalibration process aligns PTH results obtained from various immunoassays with the LC-MS/MS method, providing more consistent and reliable measurements. Thus, establishing true standardization across all PTH assays is crucial to ensure consistent interpretation and clinical decision-making.


Assuntos
Distúrbio Mineral e Ósseo na Doença Renal Crônica , Insuficiência Renal Crônica , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem , Hormônio Paratireóideo , Insuficiência Renal Crônica/diagnóstico
4.
Artigo em Inglês | MEDLINE | ID: mdl-37634391

RESUMO

Since the late 1990s, cathepsin K cleavage sites in type I collagen have been extensively studied due to its ability to release bone resorption biomarkers such as CTX and NTX. However, gel-based methods and N-sequencing used in these studies lack sensitivity, especially for small to medium peptides. In this work, we propose a degradomics mass spectrometry-based workflow that combines protein digestion, Nano-LC-UDMSE, and several software tools to identify cathepsin K cleavage sites. This workflow not only identified previously known cleavage sites, but also discovered new ones. Multiple cleavage hotspots were found and described in type I α1 and type I α2 collagen, many of which coincided with pyridinoline crosslinks, known to stabilize the triple helix. Our results allowed us to establish a chronology of digestion and conclude that cathepsin K preferentially cleaves the extremities of type I collagen before the helical part. We also found that cathepsin K preferentially cleaves amino acid residues with long and hydrophobic lateral chains at the beginning of digestion, whereas no preferred amino acid residues were identified later in the digestion. In conclusion, our workflow successfully identified new cleavage sites and can be easily applied to other proteins or proteases.


Assuntos
Aminoácidos , Colágeno Tipo I , Catepsina K , Fluxo de Trabalho , Espectrometria de Massas
5.
Phys Imaging Radiat Oncol ; 27: 100459, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37397874

RESUMO

Background and purpose: Efficient workflows for adaptive proton therapy are of high importance. This study evaluated the possibility to replace repeat-CTs (reCTs) with synthetic CTs (sCTs), created based on cone-beam CTs (CBCTs), for flagging the need of plan adaptations in intensity-modulated proton therapy (IMPT) treatment of lung cancer patients. Materials and methods: Forty-two IMPT patients were retrospectively included. For each patient, one CBCT and a same-day reCT were included. Two commercial sCT methods were applied; one based on CBCT number correction (Cor-sCT), and one based on deformable image registration (DIR-sCT). The clinical reCT workflow (deformable contour propagation and robust dose re-computation) was performed on the reCT as well as the two sCTs. The deformed target contours on the reCT/sCTs were checked by radiation oncologists and edited if needed. A dose-volume-histogram triggered plan adaptation method was compared between the reCT and the sCTs; patients needing a plan adaptation on the reCT but not on the sCT were denoted false negatives. As secondary evaluation, dose-volume-histogram comparison and gamma analysis (2%/2mm) were performed between the reCT and sCTs. Results: There were five false negatives, two for Cor-sCT and three for DIR-sCT. However, three of these were only minor, and one was caused by tumour position differences between the reCT and CBCT and not by sCT quality issues. An average gamma pass rate of 93% was obtained for both sCT methods. Conclusion: Both sCT methods were judged to be of clinical quality and valuable for reducing the amount of reCT acquisitions.

6.
Clin Chem Lab Med ; 61(10): 1700-1707, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37128992

RESUMO

Immunocapture is now a well-established method for sample preparation prior to quantitation of peptides and proteins in complex matrices. This short review will give an overview of some clinical applications of immunocapture methods, as well as protocols with and without enzymatic digestion in a clinical context. The advantages and limitations of both approaches are discussed in detail. Challenges related to the choice of mass spectrometer are also discussed. Top-down, middle-down, and bottom-up approaches are discussed. Even though immunocapture has its limitations, its main advantage is that it provides an additional dimension of separation and/or isolation when working with peptides and proteins. Overall, this short review demonstrates the potential of such techniques in the field of proteomics-based clinical medicine and paves the way for better personalized medicine.


Assuntos
Peptídeos , Proteínas , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas , Proteínas/análise
7.
J Am Soc Mass Spectrom ; 34(6): 1056-1064, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37130062

RESUMO

A growing body of literature describes the potential effects of circadian disruption on human health. Indeed, psychiatric diseases, metabolic syndrome, and cancers may be linked to disturbance of the circadian rhythm. Currently, the best practice to assess circadian rhythm is the measurement of melatonin levels. Our goal was thus to develop and validate a highly sensitive LC-MS/MS method to follow salivary melatonin levels throughout the day and night. Our method reached a lower limit of the measuring interval (LLMI) of 0.8 pg/mL. To our knowledge, it is the most sensitive method allowing quantitation of melatonin in saliva. Saliva, obtained from passive drooling or salivette, was extracted by an efficient and quick liquid-liquid extraction with no further cleanup needed. The method was validated according to the European Medicines Agency (EMA) guidelines and provided excellent results regarding accuracy, precision, linearity, selectivity, and specificity. Comparison between radioimmunoassay and our method was performed and showed differences at low levels, most likely due to cross-reactivity with other indols. To assess daytime melatonin levels in humans, salivary melatonin levels of ten volunteers were monitored throughout the day and showed lower daytime levels than reported in previous studies.


Assuntos
Melatonina , Saliva , Humanos , Cromatografia Líquida/métodos , Saliva/metabolismo , Melatonina/metabolismo , Espectrometria de Massas em Tandem/métodos , Ritmo Circadiano
8.
Radiother Oncol ; 183: 109594, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36870610

RESUMO

PURPOSE: In this study we describe the clinical introduction and evaluation of radiotherapy in mediastinal lymphoma in breath hold using surface monitoring combined with nasal high flow therapy (NHFT) to prolong breath hold duration. MATERIALS AND METHODS: 11 Patients with mediastinal lymphoma were evaluated. 6 Patients received NHFT, 5 patients were treated in breath hold without NHFT. Breath hold stability as measured by a surface scanning system was evaluated, as well as internal movement based on cone beam computed tomography (CBCT) before and after treatment. Based on internal movement, margins were determined. In a parallel planning study we compared free breathing plans with breath hold plans using the determined margins. RESULTS: Average inter breath hold stability was 0.6 mm for NHFT treatments, and 0.5 mm for non-NHFT treatments (p > 0.1). Intra breath hold stability was 0.8 vs. 0.6 mm (p > 0.1) on average. Using NHFT, average breath hold duration increased from 34 s to 60 s (p < 0.01). Residual CTV motion derived from CBCTs before and after each fraction was 2.0 mm for NHFT vs 2.2 mm for non-NHFT (p > 0.1). Combined with inter-fraction motion, a uniform mediastinal margin of 5 mm appears to be sufficient. In breath hold, mean lung dose is reduced by 2.6 Gy (p < 0.001), while mean heart dose is reduced by 2.0 Gy (p < 0.001). CONCLUSION: Treatment of mediastinal lymphoma in breath hold is feasible and safe. The addition of NHFT approximately increases breath hold durations with a factor two while stability is maintained. By reducing breathing motion, margins can be decreased to 5 mm. A considerable dose reduction in heart, lungs, esophagus, and breasts can be achieved with this method.


Assuntos
Linfoma , Neoplasias do Mediastino , Humanos , Suspensão da Respiração , Planejamento da Radioterapia Assistida por Computador/métodos , Respiração , Pulmão , Neoplasias do Mediastino/diagnóstico por imagem , Neoplasias do Mediastino/radioterapia , Dosagem Radioterapêutica , Linfoma/diagnóstico por imagem , Linfoma/radioterapia
9.
Clin Lab ; 69(3)2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36912296

RESUMO

BACKGROUND: D4-androstenedione (D4ASD) is an intermediate hormone of androgen biosynthesis by the gonads and the adrenal glands. The interest in D4ASD concentration assessment resides in diagnostics of androgenic hyperproduction pathologies. Currently, many D4ASD quantification methods are available on the market including immunological methods that remain problematic due to the possible cross-reactivity with endogenous or exogenous steroids. METHODS: Recently Roche® launched a new fully automated instrument for the measurement of D4ASD concentration. In this paper, the criteria of analytical performance (repeatability and intermediate precision) of the D4ASD Roche® assay were assessed and compared with 2 different methods including a radioimmunoassay (RIA) as well as a liquid chromatography tandem mass spectrometry (LC-MS/MS) method. RESULTS: Repeatability and intermediate precision of the D4ASD Roche® were acceptable according to the prede-fined RICOS standard (CV ≤ 7.9%) and the assay showed a good correlation with other assays considering the 95% CI obtained for the slope and the y-intercept. CONCLUSIONS: This method demonstrates acceptable criteria of analytical performance with an intermediate imprecision and a trueness within the fixed acceptance limits.


Assuntos
Androstenodiona , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Radioimunoensaio/métodos , Esteroides
10.
Clin Chem Lab Med ; 61(9): 1561-1566, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-36995129

RESUMO

OBJECTIVES: The exploration of the metabolites in the degradation pathways of vitamin D (VTD) has gained importance in recent years and simultaneous quantitation of twenty-five-hydroxy vitamin D (25(OH)D) mass concentration together with 24,25-dihydroxyvitamin D (24,25(OH)2D) has been proposed as a newer approach to define VTD deficiency. Yet, no data are available on 24,25(OH)2D biological variation (BV). In this study, we evaluated 24,25(OH)2D's BV on the European Biological Variation Study (EuBIVAS) cohort samples to determine if analytical performance specifications (APS) for 24,25(OH)2D could be generated. METHODS: Six European laboratories recruited 91 healthy participants. 25(OH)D and 24,25(OH)2D concentrations in K3-EDTA plasma were examined weekly for up to 10 weeks in duplicate with a validated LC-MS/MS method. The Vitamin D Metabolite Ratio (24,25(OH)2D divided by 25(OH)D × 100) was also calculated at each time point. RESULTS: Linear regression of the mean 24,25(OH)2D concentrations at each blood collection showed participants were not in steady state. Variations of 24,25(OH)2D over time were significantly positively associated with the slopes of 25(OH)D concentrations over time and the concentration of 25(OH)D of the participant at inclusion, and negatively associated with body mass index (BMI), but not with age, gender, or location of the participant. The variation of the 24,25(OH)2D concentration in participants over a 10 weeks period was 34.6%. Methods that would detect a significant change linked to the natural production of 24,25(OH)2D over this period at p<0.05 would need a relative measurement uncertainty (u%)<14.9% while at p<0.01, relative measurement uncertainty should be <10.5%. CONCLUSIONS: We have defined for the first time APS for 24,25(OH)2D examinations. According to the growing interest in this metabolite, several laboratories and manufacturers might aim to develop specific methods for its determination. The results presented in this paper are thus necessary prerequisites for the validation of such methods.


Assuntos
Espectrometria de Massas em Tandem , Deficiência de Vitamina D , Humanos , Cromatografia Líquida/métodos , Incerteza , Espectrometria de Massas em Tandem/métodos , Vitamina D , Deficiência de Vitamina D/diagnóstico , Vitaminas
12.
Steroids ; 187: 109096, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35931233

RESUMO

In contrast to a recent study reporting an unexpected significant difference for total 25-hydroxyvitamin D (25(OH)D) between serum and EDTA plasma, we demonstrate that concentrations of total 25(OH)D, 25(OH)D2, 25(OH)D3 and 24,25(OH)2D3 do not differ between matched serum and EDTA plasma samples, using two well-characterized LC-MS/MS methods.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , Calcifediol , Cromatografia Líquida/métodos , Ácido Edético , Espectrometria de Massas em Tandem/métodos
13.
Theriogenology ; 189: 86-91, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35738034

RESUMO

This study describes 17-ß-estradiol (E2), estrone (E1) and estrone-sulfate (E1S) concentrations between 4 and 11 months in healthy equine pregnancies of two different breeds using Liquid Chromatography coupled to Mass-Spectrometry (LC-MS). In 2 stud-farms including 15 Spanish PureBred (SPB) and 11 Showjumping (SJ) types mares, combined thickness of the uterus and the placenta (CTUP) was measured and blood was sampled monthly between 4 and 11 months of gestation. Concentrations of E2, E1 and E1S were assayed with LC-MS in mares with normal CTUP. Effects of breed, day of pregnancy and mare's parity and age on estrogens concentrations were investigated. Peak of E2 was observed at 5 months (median: 46.4 pg/mL; maximum: 201.5 pg/mL). A strong correlation was observed between E1 and E1S (p < 0.0001, r = 0.85). Peak of E1 (median: 571.0 pg/mL; maximum: 1641.9 pg/mL) and E1S (median: 573.6 ng/mL; maximum: 997.6 ng/mL) concentrations was observed at the 5th month and then E1S decreased quicker than E1 until the end of pregnancy. Higher E2 and E1 concentrations were observed in SJ than in SPB mares between the 6th and the 8th months. No difference between breeds was observed for E1S monthly evolution. Estrogen peak values were all observed at 5 months. Unlike recent LC-MS studies, E1S values observed here were in the same range than those previously established using immuno-assays. After the 6th month, E1S decreased quicker than E1. Effect of breed only observed on non-sulfonated estrogens should be further confirmed. These findings confirm that sulfonation activity of the allantochorion may be limited after the 6th month.


Assuntos
Estradiol , Estrona , Animais , Cromatografia Líquida/veterinária , Estrogênios , Feminino , Cavalos , Espectrometria de Massas/veterinária , Gravidez , Sulfatos
14.
Phys Imaging Radiat Oncol ; 22: 104-110, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35602549

RESUMO

Background and purpose: User-adjustments after deep-learning (DL) contouring in radiotherapy were evaluated to get insight in real-world editing during clinical practice. This study assessed the amount, type and spatial regions of editing of auto-contouring for organs-at-risk (OARs) in routine clinical workflow for patients in the thorax region. Materials and methods: A total of 350 lung cancer and 362 breast cancer patients, contoured between March 2020 and March 2021 using a commercial DL-contouring method followed by manual adjustments were retrospectively analyzed. Subsampling was performed for some OARs, using an inter-slice gap of 1-3 slices. Commonly-used whole-organ contouring assessment measures were calculated, and all cases were registered to a common reference shape per OAR to identify regions of manual adjustment. Results were expressed as the median, 10th-90th percentile of adjustment and visualized using 3D renderings. Results: Per OAR, the median amount of editing was below 1 mm. However, large adjustments were found in some locations for most OARs. In general, enlarging of the auto-contours was needed. Subsampling DL-contours showed less adjustments were made in the interpolated slices compared to simulated no-subsampling for these OARs. Conclusion: The real-world performance of automatic DL-contouring software was evaluated and proven useful in clinical practice. Specific regions-of-adjustment were identified per OAR in the thorax region, and separate models were found to be necessary for specific clinical indications different from training data. This analysis showed the need to perform routine clinical analysis especially when procedures or acquisition protocols change to have the best configuration of the workflow.

15.
Clin Chem Lab Med ; 60(1): 74-81, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-34727586

RESUMO

OBJECTIVES: In-house developed liquid-chromatography mass spectrometry (LC-MS/MS) methods are used more and more frequently for the simultaneous quantification of vitamin D metabolites. Among these, 24,25-dihydroxyvitamin D3 (24,25(OH)2D3) is of clinical interest. This study assessed the agreement of this metabolite in two validated in-house LC-MS/MS methods. METHODS: 24,25(OH)2D3 was measured in 20 samples from the vitamin D external quality assurance (DEQAS) program and in a mixed cohort of hospital patients samples (n=195) with the LC-MS/MS method at the Medical University of Graz (LC-MS/MS 1) and at the University of Liège (LC-MS/MS 2). RESULTS: In DEQAS samples, 24,25(OH)2D3 results with LC-MS/MS 1 had a proportional bias of 1.0% and a negative systemic difference of -0.05%. LC-MS/MS 2 also showed a proportional bias of 1.0% and the negative systemic bias was -0.22%. Comparing the EQA samples with both methods, no systemic bias was found (0.0%) and the slope was 1%. The mean difference of 195 serum sample measurements between the two LC-MS/MS methods was minimal (-0.2%). Both LC-MS/MS methods showed a constant bias of 0.31 nmol/L and a positive proportional bias of 0.90%, respectively. CONCLUSIONS: This study is the first to assess the comparability of 24,25(OH)2D3 concentrations in a mixed cohort of hospitalized patients with two fully validated in-house LC-MS/MS methods. Despite different sample preparation, chromatographic separation and ionization, both methods showed high precision measurements of 24,25(OH)2D3. Furthermore, we demonstrate the improvement of accuracy and precision measurements of 24,25(OH)2D3 in serum samples and in the DEQAS program.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , 24,25-Di-Hidroxivitamina D 3 , Cromatografia Líquida/métodos , Humanos , Manejo de Espécimes , Espectrometria de Massas em Tandem/métodos
16.
Radiother Oncol ; 165: 8-13, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34673091

RESUMO

BACKGROUND: The definition of the clinical target volume (CTV) for post-operative radiotherapy (PORT) for thymoma is largely unexplored. The aim of this study was to analyze the difference in CTV delineation between radiation oncologists (RTO) and surgeons. METHODS: This retrospective multi-center study enrolled 31 patients who underwent PORT for a thymoma from five hospitals. Three CTVs were delineated per patient: one CTV by the RTO, one CTV by the surgeon (blinded to the results of the RTO) and a joint CTV after collaboration. Volumes (cm3), Hausdorff distances (HD) and Dice similarity coefficients (DSC) were analyzed. RESULTS: RTO delineated significantly bigger CTVs than surgeons (mean: 93.9 ± 63.1, versus 57.9 ± 61.3 cm3, p = 0.003). Agreement was poor between RO and surgeons, with a low mean DSC (0.34 ± 0.21) and high mean HD of 4.5 (±2.2) cm. Collaborative delineation resulted in significantly smaller volumes compared to RTO (mean 57.1 ± 58.6 cm3, p < 0.001). A mean volume of 18.9 (±38.1) cm3 was included in joint contours, but missed by RTO. Conversely, a mean volume of 55.7 (±39.9) cm3 was included in RTO's delineations, but not in the joint delineations. CONCLUSIONS: To the best of our knowledge, this is the first study investigating CTV definition in thymoma. We demonstrated a significant variability between RTO and surgeons. Joint delineation prompted revisions in smaller CTV as well as favoring the surgeons' judgement, suggesting that surgeons provided relevant insight into other risk areas than RTO. We recommend a multidisciplinary approach to PORT for thymomas in clinical practice.


Assuntos
Timoma , Neoplasias do Timo , Humanos , Variações Dependentes do Observador , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Timoma/diagnóstico por imagem , Timoma/radioterapia , Timoma/cirurgia , Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/radioterapia , Neoplasias do Timo/cirurgia
17.
Clin Lung Cancer ; 22(6): 579-586, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34538585

RESUMO

BACKGROUND: The role of postoperative radiation therapy (PORT) in stage III N2 NSCLC is controversial. We analyzed decision-making for PORT among European radiation oncology experts in lung cancer. METHODS: Twenty-two experts were asked before and after presentation of the results of the LungART trial to describe their decision criteria for PORT in the management of pN+ NSCLC patients. Treatment strategies were subsequently converted into decision trees and analyzed. RESULTS: Following decision criteria were identified: extracapsular nodal extension, incomplete lymph node resection, multistation lymph nodes, high nodal tumor load, poor response to induction chemotherapy, ineligibility to receive adjuvant chemotherapy, performance status, resection margin, lung function and cardiopulmonary comorbidities. The LungART results had impact on decision-making and reduced the number of recommendations for PORT. The only clear indication for PORT was a R1/2 resection. Six experts out of ten who initially recommended PORT for all R0 resected pN2 patients no longer used PORT routinely for these patients, while four still recommended PORT for all patients with pN2. Fourteen experts used PORT only for patients with risk factors, compared to eleven before the presentation of the LungART trial. Four experts stated that PORT was never recommended in R0 resected pN2 patients regardless of risk factors. CONCLUSION: After presentation of the LungART trial results at ESMO 2020, 82% of our experts still used PORT for stage III pN2 NSCLC patients with risk factors. The recommendation for PORT decreased, especially for patients without risk factors. Cardiopulmonary comorbidities became more relevant in the decision-making for PORT.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Técnicas de Apoio para a Decisão , Neoplasias Pulmonares/radioterapia , Radioterapia Adjuvante , Humanos , Quimioterapia de Indução , Entrevistas como Assunto , Oncologistas/psicologia , Pesquisa Qualitativa
18.
Radiother Oncol ; 163: 136-142, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34461185

RESUMO

BACKGROUND AND PURPOSE: Quality of automatic contouring is generally assessed by comparison with manual delineations, but the effect of contour differences on the resulting dose distribution remains unknown. This study evaluated dosimetric differences between treatment plans optimized using various organ-at-risk (OAR) contouring methods. MATERIALS AND METHODS: OARs of twenty lung cancer patients were manually and automatically contoured, after which user-adjustments were made. For each contour set, an automated treatment plan was generated. The dosimetric effect of intra-observer contour variation and the influence of contour variations on treatment plan evaluation and generation were studied using dose-volume histogram (DVH)-parameters for thoracic OARs. RESULTS: Dosimetric effect of intra-observer contour variability was highest for Heart Dmax (3.4 ± 6.8 Gy) and lowest for Lungs-GTV Dmean (0.3 ± 0.4 Gy). The effect of contour variation on treatment plan evaluation was highest for Heart Dmax (6.0 ± 13.4 Gy) and Esophagus Dmax (8.7 ± 17.2 Gy). Dose differences for the various treatment plans, evaluated on the reference (manual) contour, were on average below 1 Gy/1%. For Heart Dmean, higher dose differences were found for overlap with PTV (median 0.2 Gy, 95% 1.7 Gy) vs. no PTV overlap (median 0 Gy, 95% 0.5 Gy). For Dmax-parameters, largest dose difference was found between 0-1 cm distance to PTV (median 1.5 Gy, 95% 4.7 Gy). CONCLUSION: Dose differences arising from automatic contour variations were of the same magnitude or lower than intra-observer contour variability. For Heart Dmean, we recommend delineation errors to be corrected when the heart overlaps with the PTV. For Dmax-parameters, we recommend checking contours if the distance is close to PTV (<5 cm). For the lungs, only obvious large errors need to be adjusted.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radioterapia de Intensidade Modulada , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Humanos , Neoplasias Pulmonares/radioterapia , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
19.
NPJ Breast Cancer ; 7(1): 98, 2021 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-34312396

RESUMO

Male breast cancer (BCa) is a rare disease accounting for less than 1% of all breast cancers and 1% of all cancers in males. The clinical management is largely extrapolated from female BCa. Several multigene assays are increasingly used to guide clinical treatment decisions in female BCa, however, there are limited data on the utility of these tests in male BCa. Here we present the gene expression results of 381 M0, ER+ve, HER2-ve male BCa patients enrolled in the Part 1 (retrospective analysis) of the International Male Breast Cancer Program. Using a custom NanoString™ panel comprised of the genes from the commercial risk tests Prosigna®, OncotypeDX®, and MammaPrint®, risk scores and intrinsic subtyping data were generated to recapitulate the commercial tests as described by us previously. We also examined the prognostic value of other risk scores such as the Genomic Grade Index (GGI), IHC4-mRNA and our prognostic 95-gene signature. In this sample set of male BCa, we demonstrated prognostic utility on univariate analysis. Across all signatures, patients whose samples were identified as low-risk experienced better outcomes than intermediate-risk, with those classed as high risk experiencing the poorest outcomes. As seen with female BCa, the concordance between tests was poor, with C-index values ranging from 40.3% to 78.2% and Kappa values ranging from 0.17 to 0.58. To our knowledge, this is the largest study of male breast cancers assayed to generate risk scores of the current commercial and academic risk tests demonstrating comparable clinical utility to female BCa.

20.
J Steroid Biochem Mol Biol ; 212: 105917, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34010687

RESUMO

An intralaboratory study assessing assay variability and bias for determination of serum total 25-hydroxyvitamin D [25(OH)D] was conducted by the Vitamin D Standardization Program (VDSP). Thirteen assays for serum total 25(OH)D were evaluated in a single laboratory including 11 unique immunoassays and one liquid chromatography - tandem mass spectrometry (LC-MS/MS) assay. Fifty single-donor serum samples, including eight samples with high concentrations of 25(OH)D2 (> 30 nmol/L), were assigned target values for 25(OH)D2 and 25(OH)D3 using reference measurement procedures (RMP). Using four replicate measurements for each sample, the mean total percent coefficient of variation (%CV) and mean % bias from the target values were determined for each assay using the 50 single-donor samples and a 42-sample subset, which excluded 8 high 25(OH)D2 concentration samples, and compared with VDSP performance criteria of ≤ 10 % CV and ≤ ±5 % mean bias. All 12 assays achieved the performance criterion for % CV, and 9 of the 12 assays were within ≤ ±5 % mean bias. The Fujirebio Inc. assay exhibited the lowest %CV and highest percentage of individual measurements within ≤ ±5 % mean bias. Ten immunoassays exhibited changes in response due to the high 25(OH)D2 samples with Abbott, Biomérieux, DiaSorin, DIAsource, and IDS-iSYS assays having the largest deviations. The Fujirebio Inc. and Beckman Coulter assays were only minimally affected by the presence of the high 25(OH)D2 samples. Samples with high concentrations of 25(OH)D2 provided a critical performance test for immunoassays indicating that some assays may not have equal response or recovery for 25(OH)D2 and 25(OH)D3.


Assuntos
Bioensaio/normas , Imunoensaio/normas , Vitamina D/análogos & derivados , Vitaminas/sangue , Viés , Cromatografia Líquida , Humanos , Laboratórios , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Vitamina D/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...