Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Injury ; 43(7): 1041-51, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22284334

RESUMO

BACKGROUND: Locking compression plates are used in various configurations with lack of detailed information on consequent bone healing. STUDY DESIGN: In this in vivo study in sheep 5 different applications of locking compression plate (LCP) were tested using a 45° oblique osteotomy simulating simple fracture pattern. 60 Swiss Alpine sheep where assigned to 5 different groups with 12 sheep each (Group 1: interfragmentary lag screw and an LCP fixed with standard cortex screws as neutralisation plate; Group 2: interfragmentary lag screw and LCP with locking head screws; Group 3: compression plate technique (hybrid construct); Group 4: internal fixator without fracture gap; Group 5: internal fixator with 3mm gap at the osteotomy site). One half of each group (6 sheep) was monitored for 6 weeks, and the other half (6 sheep) where followed for 12 weeks. METHODS: X-rays at 3, 6, 9 and 12 weeks were performed to monitor the healing process. After sacrifice operated tibiae were tested biomechanically for nondestructive torsion and compared to the tibia of the healthy opposite side. After testing specimens were processed for microradiography, histology, histomorphometry and assessment of calcium deposition by fluorescence microscopy. RESULTS: In all groups bone healing occurred without complications. Stiffness in biomechanical testing showed a tendency for higher values in G2 but results were not statistically significant. Values for G5 were significantly lower after 6 weeks, but after 12 weeks values had improved to comparable results. For all groups, except G3, stiffness values improved between 6 and 12 weeks. Histomorphometrical data demonstrate endosteal callus to be more marked in G2 at 6 weeks. DISCUSSION AND CONCLUSION: All five configurations resulted in undisturbed bone healing and are considered safe for clinical application.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Osteotomia/métodos , Fraturas da Tíbia/cirurgia , Animais , Fenômenos Biomecânicos , Parafusos Ósseos , Desenho de Equipamento , Feminino , Fixação Interna de Fraturas/instrumentação , Ovinos , Fraturas da Tíbia/fisiopatologia , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...