Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
J Transl Med ; 17(1): 60, 2019 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-30819197

RESUMO

BACKGROUND: Glycolysis is altered in various kidney diseases, but little is known about glycolysis in pre-eclampsia, a multi-system disorder with major pathological effects on the kidney. Urinary exosomes provide a non-invasive alternative for studying changes in kidney metabolism. This study aims to characterise the expression and phosphorylation of isozymes of the key glycolytic regulatory protein, 6-phosphofructokinase-2-kinase/fructose-2,6-bisphosphatase (PFK-2/FBPase-2), in urinary exosomes of subjects with pre-eclampsia (PE), compared to normotensive non-pregnant (NC) and normotensive pregnant (NP) controls. METHODS: A cross-sectional study of NC (n = 19), NP (n = 23) and PE (n = 29) subjects was performed. Exosomes were isolated from urine samples by differential ultracentrifugation, and then analyzed by Western blot and densitometry for expression of PFK-2/FBPase-2 isozymes (PFKFB2, PFKFB3 and PFKFB4) and phosphorylation of PFKFB2 at residues Ser483 and Ser466 and PFKFB3 at Ser461. RESULTS: PFKFB2 expression was increased 4.7-fold in PE compared to NP (p < 0.001). PFKFB2 phosphorylation at Ser483 was increased 2.6-fold in PE compared to NP (p = 0.002). Expression of phosphorylated PFKFB2/PFKFB3 at Ser466/Ser461 was increased in PE, being present in 77.4% (95% CI 59.9-88.9%) of PE and 8.3% (95% CI 1.2-27.0%) of NP samples (p < 0.001). PFKFB3 was more commonly expressed in PE, detected in 90.3% (95% CI 74.3-97.4%) of PE and 8.3% (95% CI 1.2-27.0%) of NP samples (p < 0.001). PFKFB4 had a 7.2-fold increase in expression in PE compared to NP (p < 0.001). No significant differences between NP and NC groups were observed. CONCLUSION: Regulatory proteins that increase glycolysis are increased in the urinary exosomes of subjects with pre-eclampsia, suggesting that renal glycolysis may be increased in this condition.


Assuntos
Exossomos/metabolismo , Fosfofrutoquinase-2/metabolismo , Pré-Eclâmpsia/enzimologia , Pré-Eclâmpsia/urina , Adulto , Feminino , Glicólise , Humanos , Isoenzimas/metabolismo , Fosforilação , Fosfosserina/metabolismo , Gravidez , Adulto Jovem
2.
Med Teach ; 34(12): 1033-46, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22917268

RESUMO

BACKGROUND: Medical education faces challenges posed by widening access to training, a demand for globally competent healthcare workers and progress towards harmonisation of standards. AIM: To explore potential challenges arising from variation in diversity and educational background of medical school entrants. METHOD: This study investigated the reported experience and confidence, in a range of 31 generic skills underpinning learning, of 2606 medical undergraduates entering 14 medical schools in England and South Africa, using a validated questionnaire. RESULTS: Responses suggest that there is considerable similarity in prior educational experience and confidence skills profiles on entry to South African and English medical schools. South African entrants reported significantly more experience in 'Technical skills', 'Managing their own Learning', and 'Presentation', while English students reported increased experience in 'IT' skills. South African undergraduates reported more confidence in 'Information Handling', while English students were more confident in 'IT' skills. The most noticeable difference, in 'IT' skills, is probably due to documented differences in access to computer facilities at high school level. Differences between individual schools within each country are noticeable. CONCLUSIONS: Educators need to acquire a good understanding of their incoming cohorts, and ensure necessary tailored support for skills development.


Assuntos
Aprendizagem , Faculdades de Medicina , Estudantes de Medicina/psicologia , Intervalos de Confiança , Educação de Graduação em Medicina , Inglaterra , Humanos , Autoeficácia , África do Sul , Inquéritos e Questionários
3.
Med Teach ; 34(2): 146-50, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22288992

RESUMO

BACKGROUND: Significant improvements in the delivery of criterion-based assessment techniques have improved confidence in standard setting and assessment quality. However, for underperforming students, a lack of evidence about longitudinal performance of this group poses dilemmas to educators when making decisions about the timing and nature of remediation. AIM: To investigate the longitudinal performance of the UK undergraduate medical degree students, with a particular focus on comparing the poorly performing students (i.e. those with borderline or failing grades) with the main cohort of students. METHOD: Over a 5-year period, 3200-student objective structured clinical examination (OSCE) assessments from a single medical school were investigated. A poorly performing subgroup of 125 students was identified and their longitudinal performance in the final 3 years of the undergraduate medical degree analysed. RESULT: The relative performance of this student group declines across serial OSCEs, despite current methods of 'remediation and retest'. CONCLUSIONS: This analysis demonstrates that typically students in the poorly performing subgroup achieve only short-term success with traditional remediation and retest models, and critically show an absence of longitudinal improvement. There is a clear need for institutions to develop profiling models that can help identify this student group and develop effective, research led models of remediation.


Assuntos
Competência Clínica/normas , Educação de Graduação em Medicina/normas , Avaliação Educacional/normas , Ensino de Recuperação/normas , Estudantes de Medicina , Análise de Variância , Avaliação Educacional/métodos , Humanos , Estudos Longitudinais , Avaliação de Programas e Projetos de Saúde , Ensino de Recuperação/métodos , Estudos Retrospectivos , Faculdades de Medicina , Reino Unido
4.
Thorax ; 65(10): 908-14, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20861295

RESUMO

BACKGROUND: Obstructive sleep apnoea (OSA) is a common disease that leads to daytime sleepiness and cognitive impairment. Attempts to investigate changes in brain morphology that may underlie these impairments have led to conflicting conclusions. This study was undertaken to aim to resolve this confusion, and determine whether OSA is associated with changes in brain morphology in a large group of patients with OSA, using improved voxel-based morphometry analysis, an automated unbiased method of detecting local changes in brain structure. METHODS: 60 patients with OSA (mean apnoea hypopnoea index 55 (95% CI 48 to 62) events/h, 3 women) and 60 non-apnoeic controls (mean apnoea hypopnoea index 4 (95% CI 3 to 5) events/h, 5 women) were studied. Subjects were imaged using T1-weighted 3-D structural MRI (69 subjects at 1.5 T, 51 subjects at 3 T). Differences in grey matter were investigated in the two groups, controlling for age, sex, site and intracranial volume. Dedicated cerebellar analysis was performed on a subset of 108 scans using a spatially unbiased infratentorial template. RESULTS: Patients with OSA had a reduction in grey matter volume in the right middle temporal gyrus compared with non-apnoeic controls (p<0.05, corrected for topological false discovery rate across the entire brain). A reduction in grey matter was also seen within the cerebellum, maximal in the left lobe VIIIb close to XI, extending across the midline into the right lobe. CONCLUSION: These data show that OSA is associated with focal loss of grey matter that could contribute to cognitive decline. Specifically, lesions in the cerebellum may result in both motor dysfunction and working memory deficits, with downstream negative consequences on tasks such as driving.


Assuntos
Encéfalo/patologia , Apneia Obstrutiva do Sono/patologia , Adulto , Mapeamento Encefálico/métodos , Estudos de Casos e Controles , Cerebelo/patologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Lobo Temporal/patologia
6.
Int J Artif Organs ; 28(1): 16-21, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15742305

RESUMO

BACKGROUND: The mechanisms responsible for acute renal failure in sepsis are not understood. Measurement of tissue ATP might help to understand this process but, in the large animal, it is hampered by major technical difficulties. OBJECTIVE: To develop a technique to monitor ATP in the kidney of a large mammal during the induction of septic shock and then circulatory arrest. METHODS: Implantation of a custom-made phosphorus coil around the left kidney. Induction of septic shock by intravenous E. coli administration. Acquisition of 31 P magnetic resonance (MR) spectroscopic data at 3-tesla before and during septic shock over several hours. Induction of euthanasia and measurement of the same 31 P signal immediately and thirty minutes after circulatory arrest. RESULTS: Clear reproducible 31 P MR spectra were obtained before and after the induction of septic shock and euthanasia. They indicated limited changes in ATP during septic shock. An expected rapid and dramatic decrease in ATP occurred with euthanasia. CONCLUSIONS: It is possible to sequentially monitor renal bioenergetics in a large mammal during septic shock using an implanted custom-made phosphorus coil and 3-tesla MR technology. This technique offers a novel approach to the investigation of septic renal failure.


Assuntos
Trifosfato de Adenosina/análogos & derivados , Trifosfato de Adenosina/análise , Rim/metabolismo , Choque Séptico/metabolismo , Injúria Renal Aguda/metabolismo , Animais , Bacteriemia/microbiologia , Modelos Animais de Doenças , Infecções por Escherichia coli/metabolismo , Feminino , Espectroscopia de Ressonância Magnética/instrumentação , Fosfocreatina/análise , Isótopos de Fósforo , Ovinos , Choque/metabolismo , Choque Séptico/microbiologia , Tionucleotídeos/análise
7.
Neurology ; 63(12): 2303-8, 2004 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-15623691

RESUMO

OBJECTIVE: To determine the extent and severity of mesial temporal and subcortical signal abnormalities in patients with partial epilepsy. METHODS: T2 relaxation time maps were acquired in 50 consecutive patients and 55 control subjects on a 3 T MRI scanner. Twenty-two patients had hippocampal sclerosis (HS), 16 had malformations of cortical development (MCD), and 12 had no obvious MR abnormalities (normal MR). The following eight regions were measured bilaterally: hippocampus, anterior temporal lobe (ATL) white matter, amygdala, frontal lobe white matter, caudate, putamen, pallidum, and thalamus. RESULTS: In patients with HS, increased T2 relaxation times were found in the ipsilateral hippocampus and ATL but not in subcortical nuclei. In patients with MCD, increased T2 relaxation times were found in the temporal lobe (hippocampus, ATL) and in subcortical areas (caudate, putamen, and pallidum); in patients with normal MR, increased T2 relaxation times were found in the hippocampus and putamen. The degree of abnormality did not correlate with the duration of epilepsy or the estimated seizure load. CONCLUSIONS: Mesial temporal structures show increased T2 relaxation times not only in patients with hippocampal sclerosis but also in patients with a seizure focus remote from the hippocampus. Patients with normal MR and focal malformations of cortical development have increased T2 relaxation times in subcortical structures. Therefore, abnormalities in T2 relaxation time can be found remote from the seizure focus. They cannot be simply attributed to secondary seizure effects.


Assuntos
Encéfalo/patologia , Epilepsias Parciais/patologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Gânglios da Base/patologia , Encéfalo/anormalidades , Feminino , Hipocampo/patologia , Humanos , Masculino , Especificidade de Órgãos , Cuidados Pré-Operatórios , Esclerose , Método Simples-Cego , Lobo Temporal/patologia
8.
Biochem J ; 358(Pt 3): 599-605, 2001 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-11535121

RESUMO

In the accompanying paper [Beylot, McKie, Voragen, Doeswijk-Voragen and Gilbert (2001) Biochem. J. 358, 607-614] the chromosome of Pseudomonas cellulosa was shown to contain two genes, abf51A and abf62A, that encode arabinofuranosidases belonging to glycoside hydrolase families 51 and 62, respectively. In this report we show that expression of Abf51A is induced by arabinose and arabinose-containing polysaccharides. Northern-blot analysis showed that abf51A was efficiently transcribed, whereas no transcript derived from abf62A was detected in the presence of arabinose-containing polysaccharides. Zymogram and Western-blot analyses revealed that Abf51A was located on the outer membrane of P. cellulosa. To investigate the importance of Abf51A in the release of arabinose from poly- and oligosaccharides, transposon mutagenesis was used to construct an abf51A-inactive mutant of P. cellulosa (Deltaabf51A). The mutant did not grow on linear arabinan or sugar beet arabinan, and utilized arabinoxylan much more slowly than the wild-type bacterium. Arabinofuranosidase activity in Deltaabf51A against aryl-alpha-arabinofuranosides, arabinan and alpha1,5-linked arabino-oligosaccharides was approx. 1% of the wild-type bacterium. The mutant bacterium did not exhibit arabinofuranosidase activity against arabinoxylan, supporting the view that abf62A is not expressed in P. cellulosa. These data indicate that P. cellulosa expresses a membrane-bound glycoside hydrolase family 51 arabinofuranosidase that plays a pivotal role in releasing arabinose from polysaccharides and arabino-oligosaccharides.


Assuntos
Membrana Celular/enzimologia , Regulação Bacteriana da Expressão Gênica , Regulação Enzimológica da Expressão Gênica , Glicosídeo Hidrolases/genética , Pseudomonas/enzimologia , Pseudomonas/genética , Southern Blotting , Metabolismo dos Carboidratos , Clonagem Molecular , Meios de Cultura , Escherichia coli , Pseudomonas/crescimento & desenvolvimento , Proteínas Recombinantes/metabolismo , Mapeamento por Restrição
9.
Cleft Palate Craniofac J ; 38(1): 11-4, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11204675

RESUMO

OBJECTIVE: To evaluate changes in the optical density of secondary alveolar cleft bone grafts obtained from two different donor sites over time and to determine whether one donor site gives a higher recipient bone density than the other. METHODS: A prospective study was performed evaluating 40 healthy patients with congenital cleft lip and palate undergoing secondary alveolar bone grafting, 20 (14 boys and 6 girls) having iliac crest and 20 (12 boys and 8 girls) receiving tibial bone grafts. Bone harvest and grafting was carried out by one operator (G.P.). Optical density of iliac and tibial grafts measured using a computerized densitometer, was compared at 6 days, 6 weeks, and 3 months. Due to interference from orthodontic appliances, optical density measurements for 16 subjects were not possible, and these patients were excluded from the study. The length of hospital stay postoperatively for both grafting procedures were recorded. RESULTS: A significant decrease in relative bone density was demonstrated during the 3-month postoperative period in both iliac and tibial bone graft groups (p < .05). The difference in densities between iliac crest and tibial groups were not significantly different at any of the time points (paired t test, p > .05). Subjects undergoing iliac crest grafts stayed an average of 5 days in the hospital postoperatively, compared with subjects with tibial grafts who stayed an average of 3 days postoperatively. CONCLUSION: Optical density measurements of bone grafted into alveolar clefts, reported here for the first time, provide a valuable objective assessment of graft progress. Tibial and iliac crest grafts gave similar optical densities at recipient sites over the first 3 months. Iliac crest grafts required significantly longer postoperative stay; an important consideration in selecting donor sites for secondary bone grafting.


Assuntos
Processo Alveolar/anormalidades , Alveoloplastia/métodos , Densidade Óssea/fisiologia , Transplante Ósseo/métodos , Absorciometria de Fóton/instrumentação , Absorciometria de Fóton/métodos , Adolescente , Transplante Ósseo/classificação , Transplante Ósseo/patologia , Criança , Fenda Labial/cirurgia , Fissura Palatina/cirurgia , Feminino , Seguimentos , Hospitalização , Humanos , Ílio , Processamento de Imagem Assistida por Computador/métodos , Tempo de Internação , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Estatística como Assunto , Tíbia
10.
Magn Reson Med ; 44(5): 706-12, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11064405

RESUMO

Oligemic regions, in which the cerebral blood flow is reduced without impaired energy metabolism, have the potential to evolve toward infarction and remain a target for therapy. The aim of this study was to investigate this oligemic region using various MRI parameters in a rat model of focal oligemia. This model has been designed specifically for remote-controlled occlusion from outside an MRI scanner. Wistar rats underwent remote partial MCAO using an undersize 0.2 mm nylon monofilament with a bullet-shaped tip. Cerebral blood flow (CBF(ASL)), using an arterial spin labeling technique, the apparent diffusion coefficient of water (ADC), and the relaxation times T(1) and T(2) were acquired using an 8.5 T vertical magnet. Following occlusion there was a decrease in CBF(ASL) to 35 +/- 5% of baseline throughout the middle cerebral artery territory. During the entire period of the study there were no observed changes in the ADC. On occlusion, T(2) rapidly decreased in both cortex and basal ganglia and then normalized to the preocclusion values. T(1) values rapidly increased (within approximately 7 min) on occlusion. In conclusion, this study demonstrates the feasibility of partially occluding the middle cerebral artery to produce a large area of oligemia within the MRI scanner. In this region of oligemic flow we detect a rapid increase in T(1) and decrease in T(2). These changes occur before the onset of vasogenic edema. We attribute the acute change in T(2) to increased amounts of deoxyhemoglobin; the mechanisms underlying the change in T(1) require further investigation.


Assuntos
Isquemia Encefálica/patologia , Infarto da Artéria Cerebral Média/patologia , Imageamento por Ressonância Magnética/métodos , Animais , Modelos Animais de Doenças , Masculino , Ratos , Ratos Wistar , Água/química
11.
Phys Med Biol ; 45(8): R97-138, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10958179

RESUMO

The aim of this review is to describe two recent developments in the use of magnetic resonance imaging (MRI) in the study of biological systems: diffusion and perfusion MRI. Diffusion MRI measures the molecular mobility of water in tissue, while perfusion MRI measures the rate at which blood is delivered to tissue. Therefore, both these techniques measure quantities which have direct physiological relevance. It is shown that diffusion in biological systems is a complex phenomenon, influenced directly by tissue microstructure, and that its measurement can provide a large amount of information about the organization of this structure in normal and diseased tissue. Perfusion reflects the delivery of essential nutrients to tissue, and so is directly related to its status. The concepts behind the techniques are explained, and the theoretical models that are used to convert MRI data to quantitative physical parameters are outlined. Examples of current applications of diffusion and perfusion MRI are given. In particular, the use of the techniques to study the pathophysiology of cerebral ischaemia/stroke is described. It is hoped that the biophysical insights provided by this approach will help to define the mechanisms of cell damage and allow evaluation of therapies aimed at reducing this damage.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Animais , Encéfalo/patologia , Pré-Escolar , Difusão , Humanos , Isquemia/patologia , Modelos Estatísticos , Perfusão , Ratos , Detecção de Spin/métodos
12.
J Cereb Blood Flow Metab ; 19(7): 701-35, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10413026

RESUMO

Magnetic resonance imaging techniques measuring CBF have developed rapidly in the last decade, resulting in a wide range of available methods. The most successful approaches are based either on dynamic tracking of a bolus of a paramagnetic contrast agent (dynamic susceptibility contrast) or on arterial spin labeling. This review discusses their principles, possible pitfalls, and potential for absolute quantification and outlines clinical and neuroscientific applications.


Assuntos
Circulação Cerebrovascular , Imageamento por Ressonância Magnética , Animais , Humanos , Imageamento por Ressonância Magnética/métodos
13.
Stroke ; 30(6): 1263-70, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10356110

RESUMO

BACKGROUND AND PURPOSE: Existing methods for the quantitative measurement of the changing cerebral blood flow (CBF) during reperfusion suffer from poor spatial or temporal resolution. The aim of this study was to implement a recently developed MRI technique for quantitative perfusion imaging in a gerbil model of reperfusion. Flow-sensitive alternating inversion recovery (FAIR) is a noninvasive procedure that uses blood water as an endogenous tracer. METHODS: Bilateral forebrain ischemia of 4 minutes' duration was induced in gerbils (n=8). A modified version of FAIR with improved time efficiency was used to provide CBF maps with a time resolution of 2.8 minutes after recirculation had been initiated. Quantitative diffusion imaging was also performed at intervals during the reperfusion period. RESULTS: On initiating recirculation after the transient period of ischemia, the FAIR measurements demonstrated either a symmetrical, bilateral pattern of flow impairment (n=4) or an immediate side-to-side difference that became apparent with respect to the cerebral hemispheres in the imaged slice (n=4). The flow in each hemisphere displayed a pattern of recovery close to the preocclusion level or, alternatively, returned to a lower level before displaying a delayed hypoperfusion and a subsequent slow recovery. The diffusion measurements during this latter response suggested the development of cell swelling during the reperfusion phase in the striatum. CONCLUSIONS: The CBF during the reperfusion period was monitored with a high time resolution, noninvasive method. This study demonstrates the utility of MRI techniques in following blood flow changes and their pathophysiological consequences.


Assuntos
Ataque Isquêmico Transitório/diagnóstico , Imageamento por Ressonância Magnética/métodos , Prosencéfalo/irrigação sanguínea , Traumatismo por Reperfusão/diagnóstico , Animais , Sangue/metabolismo , Água Corporal/metabolismo , Circulação Cerebrovascular/fisiologia , Gerbillinae , Ataque Isquêmico Transitório/sangue , Ataque Isquêmico Transitório/fisiopatologia , Traumatismo por Reperfusão/sangue , Traumatismo por Reperfusão/fisiopatologia , Fatores de Tempo
14.
Magn Reson Med ; 41(4): 829-40, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10332861

RESUMO

Flow-sensitive alternating inversion recovery (FAIR) is a pulsed arterial spin labeling magnetic resonance imaging method for perfusion quantification. In its standard implementation for quantification with full longitudinal relaxation between acquisitions, its use in time-course investigations of rapidly changing flow values is limited. The time efficiency can be improved by decreasing the repetition time but quantification becomes problematic. This situation is further complicated if a whole-body radiofrequency transmit coil is not used since fresh blood spins will flow in from outside the coil. To alleviate these problems, the use of global pre-saturation is proposed. The resulting expression for the flow signal depends on the relationship between the imaging parameters and the coil inflow time and can be significantly simplified under certain combinations of these parameters. With this implementation of FAIR, quantitative flow maps of gerbil brains were obtained with a 3 minute time resolution in a study of the effects of reperfusion. The pre-occlusion flow measurements were in good agreement with values obtained by the standard FAIR implementation and by other techniques, but the low values following occlusion were underestimated due to the increased transit times.


Assuntos
Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética/métodos , Animais , Simulação por Computador , Gerbillinae , Masculino , Modelos Teóricos
15.
Magn Reson Med ; 41(3): 479-85, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10204870

RESUMO

The time evolution of water diffusion, perfusion, T1, and T2 is investigated at high magnetic field (8.5 T) following permanent middle cerebral artery occlusion in the rat. Cerebral blood flow maps were obtained using arterial spin tagging. Although the quantitative perfusion measurements in ischemic tissue still pose difficulties, the combined perfusion and diffusion data nevertheless distinguish between a "moderately affected area," with reduced perfusion but normal diffusion; and a "severely affected area," in which both perfusion and diffusion are significantly reduced. Two novel magnetic resonance imaging observations are reported, namely, a decrease in T2 and an increase in T1, both within the first few minutes of ischemia. The rapid initial decrease in T2 is believed to be associated with an increase in deoxyhemoglobin levels, while the initial increase in T1 may be related to several factors, such as flow effects, an alteration in tissue oxygenation, and changes in water environment.


Assuntos
Mapeamento Encefálico/métodos , Circulação Cerebrovascular , Ataque Isquêmico Transitório/patologia , Imageamento por Ressonância Magnética/métodos , Animais , Transporte Biológico/fisiologia , Água Corporal/fisiologia , Circulação Cerebrovascular/fisiologia , Modelos Animais de Doenças , Campos Eletromagnéticos , Ataque Isquêmico Transitório/fisiopatologia , Masculino , Ratos , Ratos Wistar , Valores de Referência , Sensibilidade e Especificidade , Detecção de Spin , Fatores de Tempo
16.
Magn Reson Med ; 41(2): 368-74, 1999 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10080286

RESUMO

Magnetic resonance imaging methods that are sensitive to T2* are widely used in the study of blood oxygenation changes, most notably in functional studies of the brain. In these studies the signal intensity change in T2*-weighted imaging is related to the coupling of cerebral blood flow and metabolism. Rapid measurement of T2* itself would offer a valuable method to quantify blood oxygenation changes indirectly and monitor their time course. An interleaved echoplanar imaging (EPI) sequence is presented here that allows maps of T2* to be generated in a few seconds. The sequence benefits from reduced geometric distortion and an improved point spread function compared with single-shot EPI. A comparison among a set of T2*-weighted interleaved EPI images, single-shot EPI, and conventional gradient-echo and spin-echo methods is made using a compartmentalized doped water phantom. The interleaved sequence yields accurate T2* values when compared with reference measurements made using the slower gradient-echo technique. Data acquired from the rat brain at 2.35 T prior to and during an anoxic challenge show, with high temporal resolution, the reduction in T2* associated with increased levels of deoxyhemoglobin.


Assuntos
Circulação Cerebrovascular , Imagem Ecoplanar/métodos , Oxigênio/sangue , Animais , Feminino , Hipóxia/fisiopatologia , Imagens de Fantasmas , Ratos , Ratos Wistar
17.
Magn Reson Med ; 39(6): 950-60, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9621919

RESUMO

For the in vivo measurement of the apparent diffusion coefficient (ADC), it is desirable for the total imaging time to be as short as possible. One technique is based on a TurboFLASH acquisition in which the diffusion gradients are inserted into a driven equilibrium Fourier transform (DEFT) combination of hard pulses. However, this sequence has the disadvantage that eddy current-induced inhomogeneities lead to incomplete refocusing of the magnetization during the diffusion preparation and to incorrect ADC values. A modification to the sequence is suggested that eliminates this error by phase-cycling the second 90 degrees pulse of the preparation. This study also investigates the effect of a reduced delay time between acquisitions on the accuracy of the measurement. The quality of the TurboFLASH sequence is demonstrated by experimental validation on an agar phantom and in vivo on the rat brain using a high-field (8.5 T) system. Reduction of the interexperiment delay time is shown to be achievable to a certain degree without compromising the measurement accuracy.


Assuntos
Água Corporal/metabolismo , Encéfalo/anatomia & histologia , Aumento da Imagem/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Animais , Artefatos , Difusão , Imagem Ecoplanar/instrumentação , Humanos , Masculino , Ratos , Ratos Wistar , Valores de Referência
18.
Br J Oral Maxillofac Surg ; 33(6): 370-4, 1995 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8838952

RESUMO

Surgical access to the clivus and upper cervical spine may be facilitated by a number of approaches. The Le Fort I maxillary osteotomy has been described to give improved access to the skull base for removal of tumours and treating vertebrobasilar aneurysms. We describe a case in which the combination of a particularly high translocation of the body of C2 and poor mouth opening had precluded a standard transoral approach by restricting access to the operative field. Anterior decompression of the body of C2 was therefore performed via a maxillary down-fracture with the aid of an interactive image guidance system, the ISG Viewing Wand. The ISG Viewing Wand is a new intra-operative 3 dimensional (3D) image guidance system which has now been used in over three hundred neurosurgical cases at Frenchay Hospital, Bristol. We briefly discuss the principles of the viewing wand and describe its unique application providing anatomical navigation in upper cervical spine surgery.


Assuntos
Vértebra Cervical Áxis/cirurgia , Atlas Cervical/cirurgia , Diagnóstico por Imagem/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Maxila/cirurgia , Osteotomia/métodos , Idoso , Vértebra Cervical Áxis/diagnóstico por imagem , Vértebra Cervical Áxis/patologia , Encefalopatias/etiologia , Tronco Encefálico/patologia , Atlas Cervical/diagnóstico por imagem , Feminino , Forame Magno/cirurgia , Humanos , Imageamento por Ressonância Magnética , Processo Odontoide/diagnóstico por imagem , Processo Odontoide/patologia , Processo Odontoide/cirurgia , Parestesia/etiologia , Radiografia , Compressão da Medula Espinal/etiologia , Doenças da Coluna Vertebral/complicações , Doenças da Coluna Vertebral/diagnóstico por imagem , Doenças da Coluna Vertebral/cirurgia
19.
Dent Update ; 22(9): 380-2, 1995 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8948228

RESUMO

Obstructive sleep apnoea is a well recognized clinical problem. This paper presents a case in which a joint orthodontic and surgical approach was used to diagnose and treat a patient suffering from this condition. Initially these cases could be treated with a conservative approach, which has a potential role in establishing a diagnosis.


Assuntos
Má Oclusão Classe II de Angle/terapia , Obstrução Nasal/complicações , Retrognatismo/complicações , Síndromes da Apneia do Sono/terapia , Adulto , Feminino , Humanos , Má Oclusão Classe II de Angle/complicações , Má Oclusão Classe II de Angle/cirurgia , Avanço Mandibular , Obstrução Nasal/cirurgia , Aparelhos Ortodônticos Funcionais , Osteotomia , Equipe de Assistência ao Paciente , Retrognatismo/cirurgia , Síndromes da Apneia do Sono/etiologia , Síndromes da Apneia do Sono/cirurgia , Conchas Nasais/anormalidades , Conchas Nasais/cirurgia
20.
Br J Oral Maxillofac Surg ; 28(5): 340-3, 1990 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-2248944

RESUMO

Cysts of the mandibular condyle are rare and their diagnosis and treatment can be difficult. A case in a young girl is described where the histology was that of a solitary bone cyst but the presentation and behaviour more closely resembled an aneurysmal bone cyst.


Assuntos
Cistos Ósseos/diagnóstico , Côndilo Mandibular , Doenças Mandibulares/diagnóstico , Cistos Ósseos/diagnóstico por imagem , Cistos Ósseos/patologia , Criança , Feminino , Hemorragia/patologia , Humanos , Côndilo Mandibular/diagnóstico por imagem , Côndilo Mandibular/patologia , Doenças Mandibulares/diagnóstico por imagem , Doenças Mandibulares/patologia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...