Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Zhonghua Nan Ke Xue ; 22(7): 621-625, 2016 Jul.
Artigo em Chinês | MEDLINE | ID: mdl-28965380

RESUMO

OBJECTIVE: To compare the effect of inlaid labial mucosal graft repair (LMGR) with that of bladder mucosal graft repair (BMGR) in the treatment of complex urethral skin fistula after hypospadias repair. METHODS: This study included 55 cases of complex urethral skin fistula following hypospadias repair. We randomly assigned them to receive inlaid LMGR (n=36) or BMGR (n=19). After surgery, we compared the incidence of complications and recurrence rate of urinary fistula between the two groups of patients. RESULTS: The success rates of operation were 91.7% and 84.2% in the LMGR and BMGR groups, respectively, and the penile appearance was desirable in both groups. Postoperative complications included 2 cases of urinary fistula and 1 case of urethral stricture in each group. There were no statistically significant differences between the two groups in the success rate of operation (P>0.05) or the incidence rate of postoperative complications (P>0.05). CONCLUSIONS: Both inlaid LMGR and BMGR yield satisfactory results in the treatment of complex urethral skin fistula. However, LMGR involves less injury in mucosa collection and is easier to perform and therefore deserves more clinical attention.


Assuntos
Fístula Cutânea/cirurgia , Procedimentos de Cirurgia Plástica , Bexiga Urinária/cirurgia , Fístula Urinária/cirurgia , Procedimentos Cirúrgicos Urológicos Masculinos , Humanos , Hipospadia/cirurgia , Incidência , Masculino , Complicações Pós-Operatórias , Recidiva , Uretra/cirurgia
2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 36(2): 133-5, 2012 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-22737896

RESUMO

The potential problems of QA (quality assurance) and safety control of medical equipment in hospital were analyzed. On this base, this paper developed the testing system for the performance tests and the safety inspections of medical equipment in hospital, and discusses the results and the problems existing in the running systems.


Assuntos
Equipamentos e Provisões , Segurança de Equipamentos , Controle de Qualidade
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 32(3): 198-202, 2008 May.
Artigo em Chinês | MEDLINE | ID: mdl-18754423

RESUMO

According to the patient examination criterion and the demands of all related departments, the DSA digital subtraction workstation has been successfully designed and is introduced in this paper by analyzing the characteristic of video source of DSA which was manufactured by GE Company and has no DICOM standard interface. The workstation includes images-capturing gateway and post-processing software. With the developed workstation, all images from this early DSA equipment are transformed into DICOM format and then are shared in different machines.


Assuntos
Angiografia Digital/métodos , Design de Software , Interface Usuário-Computador , Angiografia Digital/instrumentação , Processamento de Imagem Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...