Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Oral Rehabil ; 28(9): 849-53, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11580823

RESUMO

This study investigated effects of electromyographic (EMG) biofeedback (BFB) and transcutaneous electrical neuromuscular stimulation (TENS) on the EMG activity of the masticatory muscles and skin conductance level (SCL) of patients, suffering from myofacial pain syndrome. In the course of the investigation, EMG activity as well as the SCL was measured after a 20 min BFB or, respectively, after a myomonitor session in 20 patients and pre- and post-treatment values were compared. Results showed tendencies of decreased mean-EMG levels for both groups after the treatment sessions, with higher EMG values for the myomonitor group. There was no indication of a significant decrease in mean EMG levels over the sessions. Furthermore, an increase of the SCL during the period of treatment was observed for both groups in session I and II, while session III produced nearly stable values. No existing correlations for changes in SCL and EMG-activity could be established.


Assuntos
Biorretroalimentação Psicológica , Bruxismo/terapia , Músculos da Mastigação/fisiopatologia , Relaxamento Muscular , Estimulação Elétrica Nervosa Transcutânea , Adulto , Eletromiografia , Neuralgia Facial/terapia , Feminino , Resposta Galvânica da Pele , Humanos , Masculino , Projetos Piloto , Terapia de Relaxamento , Resultado do Tratamento
2.
J Oral Rehabil ; 27(7): 629-38, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10931257

RESUMO

Transfer of the precise position of implants to a master cast is a prerequisite for accurate and passive fit of the superstructure. Implants lack the mobility of natural teeth and, therefore, inaccurate frameworks result in stress within the mechanical parts and the implant-bone interface. Various impression methods have been described to achieve accurate reproduction of the intra-oral relation of the implants. The aim of this experimental study was to compare three different impression materials (polyether, polyvinyl siloxane, hydrocolloid) with the Frialit(R)-2 system and with the indirect technique. In addition, the use of transfer caps (TCs) to improve transfer precision was tested with all three materials. All measurements were performed using a three-dimensional (3D) co-ordinate measuring machine that is capable of locating points in space and calculating the relative distortions as angles of tilt (rot-XY, rot-XZ, rot-YZ) and 3D displacement. The results suggest that addition-silicone (a-silicone) and polyether are the materials of choice for implant transfer procedures. The use of TCs resulted in a significantly reduced rotation in the XY-plane but did not improve the absolute 3D displacement. A-silicone with the use of TCs proved to be most precise. Comparison between polyether and polyvinyl siloxane showed significant differences in the XY-rotation and the 3D displacement in favour of the silicone. Because the mean distortions between the original model and the master casts were about 100 microm, absolutely precise fit may be unattainable owing to the physical properties of the materials. Further studies will have to evaluate the amount of tolerable stress at the implant-bone interface.


Assuntos
Materiais para Moldagem Odontológica , Técnica de Moldagem Odontológica/instrumentação , Prótese Dentária Fixada por Implante , Modelos Dentários , Alginatos , Óxido de Alumínio , Análise de Variância , Implantes Dentários , Planejamento de Prótese Dentária , Retenção em Prótese Dentária , Humanos , Polivinil , Ajuste de Prótese , Reprodutibilidade dos Testes , Resinas Sintéticas , Siloxanas , Estatísticas não Paramétricas
3.
J Oral Rehabil ; 27(4): 344-8, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10792596

RESUMO

This preliminary study investigated Myrhaug's neuromuscular hypothesis by means of audiological and electromyographic assessment. After a clinical examination of the TMJ system, the activity of the tensor veli palatini muscles in the state of rest and during swallowing was investigated in 16 patients with the help of an EMG recording, and the tube-opening function was evaluated endoscopically. Results showed that 6.25% of the patients suffered from mild joint-dysfunction (group I), 81.25% from a moderate dysfunction (group II), and 12.5% from severe dysfunction (group III). Although five patients suffered from tinnitus and 11 from fullness in the ear, both the audio- and tympanogram performed on 15 patients displayed normal recordings. Only one patient suffered from moderate sensorineural hearing loss. In the EMG recording, 11 of the 16 subjects displayed normal EMG patterns in state of rest and during swallowing contraction. In two cases, abnormal EMG recordings were obtained due to incorrect insertion of the EMG needle. The study's results indicate that spasm in the masticatory muscles of TMJ patients neither seems to cause reflex spasm of the tensor palatini muscles nor to effect significant alterations in Eustachian tube function.


Assuntos
Eletromiografia , Transtornos da Audição/fisiopatologia , Músculos Palatinos/fisiopatologia , Transtornos da Articulação Temporomandibular/fisiopatologia , Adulto , Audiometria de Tons Puros , Deglutição , Eletromiografia/instrumentação , Eletromiografia/métodos , Feminino , Transtornos da Audição/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Inquéritos e Questionários , Transtornos da Articulação Temporomandibular/diagnóstico
4.
Int J Periodontics Restorative Dent ; 20(3): 255-67, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11203567

RESUMO

The aim of the present study was to investigate clinical and radiographic data of patients treated with implants in the posterior maxilla in combination with sinus augmentation. Study parameters included Periotest values, radiographic analysis, and survival/success rates up to 5 years. Clinical and radiographic criteria resulted in a success rate of 92.7% for sinus implants. Radiographically, the sinus implants showed a mean coronal bone loss of 0.5 mm at 6 months and 1.2 mm at 48 months. The results showed stable periimplant parameters for sinus implants during the observation period of 5 years. The success rates showed no significant differences regarding different implant-supported treatment options for the posterior maxillary region.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Seio Maxilar/cirurgia , Procedimentos Cirúrgicos Pré-Protéticos Bucais , Adulto , Substitutos Ósseos , Implantação Dentária Endóssea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Minerais , Dente Molar , Osseointegração , Estudos Retrospectivos , Taxa de Sobrevida
5.
J Prosthet Dent ; 82(4): 482-4, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10512970

RESUMO

This article describes a method for fabricating an auricular prosthesis. This procedure uses the contours of the soft tissue surface from computerized tomography scans to fabricate a computer-generated, side-inverted 3-dimensional soft tissue model from a solid block of polyurethane using an Endoplan milling machine. The resultant 3-dimensional soft tissue model can then be used as the basis for a wax sculpture. This procedure facilitates the planning of the prosthesis; symmetrical modeling, especially for large, hemifacial defects; and the impression, which can be made on the model itself.


Assuntos
Simulação por Computador , Orelha Externa , Modelos Anatômicos , Próteses e Implantes , Resinas Acrílicas , Orelha Externa/diagnóstico por imagem , Humanos , Polivinil , Desenho de Prótese/métodos , Siloxanas , Tomografia Computadorizada por Raios X
6.
Dtsch Z Mund Kiefer Gesichtschir ; 15(4): 285-91, 1991.
Artigo em Alemão | MEDLINE | ID: mdl-1816959

RESUMO

In 105 patients with composite resections of the mandible different reconstructive approaches were studied. In 63% the defect was bridged with metal plates alone, in 15% free grafts, and in 22% microvascular bone grafts were used. The high failure rate of free grafts (48%) was contrasted by the low rate (8%) of vascularized grafts lost. Resorption of vascularized grafts was not observed where the anastomoses remained patent.


Assuntos
Transplante Ósseo/métodos , Mandíbula/cirurgia , Microcirculação/cirurgia , Anastomose Cirúrgica , Placas Ósseas , Reabsorção Óssea/etiologia , Transplante Ósseo/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...