Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Oral Maxillofac Surg ; 19(1): 65-70, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25015878

RESUMO

OBJECTIVE: The purpose of this study was to compare, by mechanical in vitro testing, a regular 5-hole plate and a long 4-hole plate with a regular 4-hole plate, applied to stabilize a simulated mandibular angle fracture. STUDY DESIGN: The plates from the 2.0-mm titanium-based system were adapted and stabilized passively in the same site in both groups using four screws, 6 mm long. During the resistance-to-load test, the force was applied perpendicular to the occlusal plane at three different points: first molar at the plated side, first molar at the contralateral side, and between the central incisors. RESULTS: The regular 5-hole plates and longer 4-hole plates were superior to the regular 4-hole plates. Furthermore, no statistically significant difference was found between the regular 5-hole plates and long 4-hole plate. CONCLUSIONS: The length and shape of plates did not interfere with the effectiveness to stabilize the fragments. OBJECTIVE: The purpose of this study was to compare, by mechanical in vitro testing, a regular 5-hole plate and a long 4-hole plate with a regular 4-hole plate, applied to stabilize a simulated mandibular angle fracture.Study design The plates from the 2.0-mm titanium-based system were adapted and stabilized passively in the same site in both groups using four screws, 6 mm long. During the resistance-to-load test, the force was applied perpendicular to the occlusal plane at three different points: first molar at the plated side, first molar at the contralateral side, and between the central incisors. RESULTS: The regular 5-hole plates and longer 4-hole plates were superior to the regular 4-hole plates. Furthermore, no statistically significant difference was found between the regular 5-hole plates and long 4-hole plate.Conclusions The length and shape of plates did not interfere with the effectiveness to stabilize the fragments.


Assuntos
Fenômenos Biomecânicos , Placas Ósseas , Fraturas Mandibulares/cirurgia , Titânio , Parafusos Ósseos , Desenho de Equipamento , Humanos , Técnicas In Vitro
4.
Rev. bras. odontol ; 64(3/4): 152-154, 2007. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-541869

RESUMO

O lábio duplo é uma alteração da mucosa labial presente com maior frequência no lábio superior, podendo ser de origem congênita ou traumática. O tratamento de escolha deve ser o cirúrgico, com finalidade estética e funcional. Neste trabalho é apresentado um caso de lábio duplo em um paciente de 35 anos de idade onde a exérese do tecido hiperplásico foi realizada com total satisfação do paciente no pós-operatório.


Assuntos
Humanos , Masculino , Adulto , Anormalidades Congênitas/cirurgia , Hiperplasia , Lábio/anormalidades , Lábio/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA