Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Food Res Int ; 158: 111549, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35840243

RESUMO

This work proposes an innovative approach to valorise swine blood based on enzymatic hydrolysis and membrane fractionations. Hydrolysis with Cynara cardunculus enzymes, followed by microfiltration and double nanofiltration generated three high protein fractions, retentate of microfiltration (RMF; >0.5 µm) and retentate of nanofiltration (RNF; >3 kDa) with approximately 90% of protein on a dry basis and filtrate of nanofiltrate (FNF; <3 kDa) with 65%. FNF, rich in low molecular weight peptides, showed excellent antioxidants (ABTS and ORAC of 911.81 and 532.82 µmol TE g-1 DB, respectively) and antihypertensive (IC50 of 28.51 µg mL-1) potential. By peptidomics and in silico analysis, 43 unique sequences of interest were found, among which LVV-Hemorphin-7 was identified. This hemorphin was demonstrated as the main responsible for the observed bioactivity. Complementary results showed a prebiotic effect mainly for the growth of Bifidobacterium animalis Bo, as well as interesting free amino acids (mainly glutamic acid, leucine, alanine, phenylalanine and aspartic acid) and mineral (e.g., Ca, Mg, P, K and Na) profiles. No antibacterial effect was verified for the seven pathogenic bacteria tested. This study allowed obtaining new ingredient of high nutritional and nutraceutical value for human consumption, with a perspective of sustainability and industrial viability.


Assuntos
Cynara , Animais , Antioxidantes/química , Suplementos Nutricionais , Humanos , Peptídeos/química , Hidrolisados de Proteína/química , Suínos
2.
J Appl Clin Med Phys ; 19(1): 250-258, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29193644

RESUMO

PURPOSE: The purpose of this study was to evaluate the efficacy of needle holders in reducing staff hand exposure during biopsies guided by computed tomography fluoroscopy (CTF), through the analysis of data acquired during a detailed monitoring study, undertaken in parallel with an ongoing optimization process to reduce hand irradiation. METHODS: Hand monitoring was performed with 11 extremity detectors, two per finger (base and tip) and one on the back of the wrist, for the left (dominant) hand, during two series of biopsies with comparable characteristics. The first series (47 biopsies) were performed with only quick-check method (QC) and occasional side-handle (SH) manipulation of the needle. The second series (63 biopsies) were performed after introducing needle holders (NH) in the course of an optimization process. RESULTS: Choice of technique (QC, QC + NH, QC + SH) by the interventional radiologist (IR) was related to biopsy difficulty. Measured hand exposure was low (< 1 mSv) for all QC-only procedures, and for most of the QC + NH procedures. Occasional side-handle manipulation still occurred during challenging biopsies, so that 8% of biopsies in the second series accounted for ~70% of total fingertip dose (~90 mSv). The methodology used allowed a detailed insight into the dose reduction achievable with needle holders during real procedures, without the limitations of phantom measurements. CONCLUSIONS: Needle holders proved effective in reducing mean hand exposure during clinical procedures where real-time manipulation was necessary. Occasional side-handle manipulation was found to contribute disproportionately to hand exposure. This highlights the importance of individual hand monitoring during CTF guided procedures.


Assuntos
Fluoroscopia/instrumentação , Mãos/efeitos da radiação , Exposição Ocupacional/análise , Imagens de Fantasmas , Proteção Radiológica/métodos , Radiografia Intervencionista/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Biópsia por Agulha , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
3.
J Appl Clin Med Phys ; 17(1): 316-327, 2016 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-26894341

RESUMO

Computed tomography fluoroscopy (CTF) is a useful imaging technique to guide biopsies, particularly lung biopsies, but it also has the potential for very high hand exposures, despite use of quick-check method and needle holders whenever feasible. Therefore, reliable monitoring is crucial to ensure the safe use of CTF. This is a challenge, because ring dosimeters monitor exposure only at the base of one finger, while the fingertips may be exposed to the highly collimated CT beam. In this work we have explored the possibility of using Gafchromic XR-QA2 self-developing film as a complementary dosimeter to quantify hand exposure during CTF-guided biopsies. A glove used in a previous study and designed to contain 11 TLDs was adapted to include Gafchromic strips 7 mm wide, covering the fingers. A total of 22 biopsies were successfully performed wearing this GafTLD glove under sterile gloves, and the IR reported no difficulty or reduction of dexterity while wearing it. Comparison of dose distributions obtained from digitization of the Gafchromic film strips and absolute Hp(0.07) readings from TLDs showed good agreement, despite some positional uncertainty due to relative movement. Per procedure, doses at the base of the ring finger can be as low as 3%-8% of hand dose maximum. Accumulated dose at the base of the ring finger was four times lower than the dose maximum.


Assuntos
Dosimetria Fotográfica/métodos , Fluoroscopia/métodos , Mãos/efeitos da radiação , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Biópsia , Calibragem , Dosimetria Fotográfica/instrumentação , Mãos/diagnóstico por imagem , Humanos , Doses de Radiação , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...