Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Water Sci Technol ; 64(9): 1906-12, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22020486

RESUMO

Granular sludge formation was performed in a laboratory scale Sequencing Batch Reactor (SBR) fed with supernatant of anaerobic digestion of sewage sludge. This effluent was concentrated progressively in order to enhance biomass capacity without inhibiting it. During the first part of the study, ammonium nitrogen was converted to nitrate, so conventional nitrification took place. When a nitrogen load of 0.8 g N L(-1) d(-1) was treated, the effluent concentration of nitrite started to increase while the nitrate concentration decreased until it disappeared. So, partial nitrification was achieved. At the end of this study, a nitrogen load of 1.1 g N L(-1) d(-1) was treated obtaining an effluent with 50% ammonium and 50% nitrite. The volatile suspended solids concentration in the reactor reached 10 g VSS L(-1). At this point the granule morphology was quite round and no filamentous bacteria was observed. The Feret's diameter was in the range between 1 and 6 mm with an average value of 4.5 mm. Roundness value was all the time higher than 0.7. Granule density increased during the experimental period, obtaining a final value of 7.0 g L(-1).


Assuntos
Nitrificação , Esgotos/química , Água/química , Aerobiose , Anaerobiose , Biomassa , Reatores Biológicos/microbiologia , Nitratos/análise , Nitritos/análise , Nitrogênio/análise , Compostos de Amônio Quaternário/análise , Eliminação de Resíduos Líquidos
2.
Eur J Med Res ; 5(1): 19-22, 2000 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-10657284

RESUMO

Sudden Infant Death Syndrome (SIDS) is the most frequent cause of infant death within the period of 2 to 12 months in western countries. It has been found that a suit similar to that worn by the astronauts during the execution of experiments on the Spacelab Mission D-2 is a very simple and useful means to carry the sensors required to monitor vital signs of babies at risk. A small baby-suit has been developed with the same technology used for the Spacelab Mission. The baby s suit is equipped with similar sensors to record thoracic and abdominal respiratory movements as its big -space travel brother-. This is a typical example of a successful technology transfer from medical aerospace activities into fields of daily clinical routine. In addition to the above described sensors, ECG-electrodes were integrated, as well as sensors to record vascular oxygen saturation and the corresponding pulse curve, and the baby s movements. All these vital signs are registered by a medical monitor, and permanently stored and automatically analysed online. In case of a life-threatening situation the system alerts simultaneously the personal at hospital and the parents at home. The requisite software algorithms have been developed by DLR in Cooperation with the pediatricians of the Pediatric Hospital in Köln-Porz, Cologne. When the system registers an alteration of the parameters above described -as a signal of a change in the baby s health condition- all vital signs are transfered in real-time to the supervising hospital via radio data transmission devices, mobile phone or a fixed network phone. The parents are also alerted by the device, and they can carry out the necessary reanimation procedures in case of an emergency. Parents will be trained in such actions when newborns must to be monitored. But nevertheless, they are guided and tele-assisted by an expert via telephone during the action. A clinical field trial, that will start in December 1999 at the Pediatric Hospital in Köln-Porz, Cologne, will evaluate the benefits of teleprotection by home monitoring of SIDS risk-babies.


Assuntos
Morte Súbita do Lactente/diagnóstico , Telemetria , Humanos , Lactente , Recém-Nascido , Monitorização Fisiológica , Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...